Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-04-2025 | Corrigendum No. 3 Date Extension | Date | 25-04-2025 |
| Sl. No. | Item Description |
| 1 | CIVIL WORK -1.1-Dismantling stone masonry in lime or cement mortar including stacking the materilsas directed with all leads, lifts etc.( Ground Level ) |
| 2 | 1.2-Dismantlingbrickmasonryinlimeorcementmortarandstackingthematerilsas directed with all leads, lifts etc.( Ground Level ) |
| 3 | 1.3-DismantlingtheR.C.C.Work1:2:4andsortingoutthematerialssuchassteeletc.as directed and stacking them within the specified lead as directed etc. complete. ( Ground Level ) |
| 4 | 1.4-Removingdoorsandwindowswithframesandstackingthematerialsasdirected withall leads, lifts etc. complete. ( Ground Level ) |
| 5 | 1.5-Removingcementtiles,ormarbleorpolished shahabadfloorordadowithoutbed concrete including stacking the materials as directed with all leads, lifts etc. complete ( Ground Level ) |
| 6 | 1.6-Removing Manglore tiled roof and ridge tiles with battens, ridge and barge boards, eaves 8A boardsetcandsackingthematerialsasdirectedwithall leadsand liftscomplete. Including removing wood work below etc. complete. ( Ground Level ) |
| 7 | 1.7-RemovingG.I.orA.C.sheetroofingincludingpurlins,principalraftersetc.including sortingserviceable and unserviceable materials, stacking the same as and where directedinthe compound including scaffolding etc. complete. ( Ground Level ) |
| 8 | 1.8-Removingandloweringtherooftrusscarefullywithoutdamagingthemembersand stacking as and where directed in the compound including scaffolding etc. complete. ( Ground Level ) |
| 9 | 1.9-Conveyingand disposing off the debrisup to10 Kilometers distance out of PMC limit including loading and unloading etc.complete. ( Ground Level ) |
| 10 | 2.1-Removinggrass,gazergrassanddisposingoffoutofbuildingpremisesincluding making clean the ground by shovel and phavaras etc. complete. ( Ground Level ) |
| 11 | 2.2-Excavationforfoundationinearth,soilofalltypes,sand,gravelandsoftmurum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthe buildingareaand stackingandspreadingasdirected,dewatering,preparingthebed forthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. Including all Leads and Lifts By Mechanical Means ( Ground Level ) |
| 12 | 2.3-Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed,dewatering,preparingthe bed forthe foundationand necessary back filling,ramming, watering including shoring and strutting etc. complete. Including all Leads and Lifts.By Mechanical Means ( Ground Level ) |
| 13 | 2.3A-Excavation for foundation in Hard murumand boulders including removingthe excavatedmaterial upto a distance of 50metres, beyondthe buildingarea andstacking andspreadingasdirected, dewatering, preparing the bed for the foundation and necessarybackfilling, ramming, watering including shoring and strutting etc. complete. Including all Leads and Lifts. By Mechanical Means ( Ground Level ) |
| 14 | 2.4-ExcavationforfoundationinSoftrockandoldcementorlimemasonryfoundations includingremovingtheexcavatedmaterialuptoadistanceof50metresbeyondthe buildingareaandstackingasdirected,includingdewatering,preparingthebedforthe foundationandnecessarybackfillingwith availableearth/murum,ramming,watering including shoring andstrutting etc. complete. Including all Leads and Lifts. By Mechanical Means ( Ground Level ) |
| 15 | 2.4A-Excavation for foundation in Soft rock and old cernent or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with avallable earth/murum, ramming, watering including shoring and strutting etc. complete. Including all Leads and Lifts. By Mechanical Means ( Ground Level ) |
| 16 | 2.5-Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete.Including all Leads and Lifts. By Mechanical Means ( Ground Level ) |
| 17 | 2.5A-Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete.Including all Leads and Lifts. By Mechanical Means ( Ground Level ) |
| 18 | 2.6-Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 3.0BHPpumpetc.complete.(priorapprovalofSuperintendingEngineerwillbe necessary) |
| 19 | 2.7-Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating thebottomsurfaceandsidesofexcavationattherateof5litresofemulsion concentrateof1.0percent of chlorophyrifos per square meter of surface area covering10yearsguaranteeon bond paper. ( Ground Level ) |
| 20 | 2.8-ProvidingpreconstructionalantitermitetreatmentasperI.S.6313(Part-II)treatment bytreatingthebackfillinimmediatecontactwithfoundationattherateof5litresof emulsionconcentrateof1.0percentofclorophyrifosper OneSquareMetreofvertical surface area covering 10 years guarantee on bond paper. ( Ground Level ) |
| 21 | 2.9-Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surfaceofplinthfillingattherateof5litresofemulsionconcentrateat1.0 percent ofclorophyrifos per OneSquareMetreofsurfaceareacoveringtenyears guarantee on bond paper. ( Ground Level ) |
| 22 | 2.10-Fillinginplinthandfloorswith approved excavatedmaterialin15cm.to20cm. Layers including watering and compacting etc. complete. ( Ground Level ) |
| 23 | 2.11-Filling in plinth and floors with contractorsmaterial/brought from outside and approved byEngineer inchargein layers of 15 cmto 20 cm including watering and compactionetc. complete. ( Ground Level ) |
| 24 | 2.12 -Providing dry/trap/granite/quartzite/gneiss rubble stone soling 15cm to 20cm thick including hand packing and compacting etc. complete. (Item No. 21.38) (Labour rate) |
| 25 | 2.13-Providingandfixing20to25mmthickroughshahabadboxtypewaterproofingfor basement orundergroundflooronabaseofCementconcrete1:3:6,includingsub baseof 2.50 centimeterthick Cementmortar 1:3with conceal,secrete (RMW),Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the jointswith 6mmsizecrushedmetal,handgroutingwithcementslurry,curingand cleaning,with7yearsguaranteeoncourtfeestampofRs.100/- withpondingtestetc complete. (excluding Cement concrete 1:3:6 base concrete ) ( Basement 01 ) |
| 26 | 4.8-Stilt Floor |
| 27 | 2.14-Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gapof 25 mm betweenrough shahabadand R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method,brushing the joints horizontally with cement slurry mixed with water proofingliquidfor width 30 to 35 mm and sloping coping over topmost tile with cement mortar1:3,buttingthebottom most with Cement concrete1:2:4 mixed with water proofing liquid,curing,with7 yearsguaranteeoncourtfeestampofRs.100/-with ponding testetccomplete.(excluding Cement concrete 1:3:6 base concrete) ( Basement 01 ) |
| 28 | 4.9-Stilt Floor |
| 29 | 2.15-Providing and laying Cast in situ/ReadyMix cement concrete in M-10 of trap/ granite/quartzite/ gneiss metal for foundation and bedding including bailing out water, Steelcentering,formwork,laying/pumping,compacting,rougheningthemif special finish is to be provided,finishingifrequiredandcuringcomplete,withfully automatic micro processorbasedPLCwithSCADAenabled concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade)( Basement 01 ) |
| 30 | 4.3,6.3-( Ground Level ) |
| 31 | 2.16-Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. workin foundations like raft, strip foundations, grillage andfootings of R.C.C. columns and steel stanchionsetc. columns as per detailed designsanddrawing or as directed including steel centering, formwork, cover blocks, laying/pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimumthicknesstogiveasmoothandevensurfaceor rougheningifspecialfinishistobeprovidedandcuringetc.complete.(Excluding reinforcementandstructuralsteel).withfullyautomaticmicro processor based PLC with SCADAenabledconcreteBatchmixplant(Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( Ground Floor ) |
| 32 | 2.17A-Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to beprovidedandcuringetc.complete,(Excludingreinforcementandstructural steel).withfully automaticmicroprocessorbasedPLCwithSCADA enabledconcreteBatchmixplant(Panmixer)etc.complete.Withfine aggregate (Crushed sand VSI Grade) ( Basement Floor ) |
| 33 | 2.17B-( Stilt floor ) |
| 34 | 2.17C-( Ground Floor ) |
| 35 | 2.17D-( First Floor ) |
| 36 | 2.17E( Second Floor ) |
| 37 | 2.17F-( Third Floor ) |
| 38 | 2.17G-( Fourth Floor ) |
| 39 | 2.17H-( Fifth Floor ) |
| 40 | 2.17I-( Sixth Floor ) |
| 41 | 2.18A-Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/gneissmetal forR.C.C.beamsandlintelsasperdetaileddesignsand drawings or asdirectedincludingsteelcentering,formwork,coverblocks, laying/pumping,compactionand roughening the surface if special finish is to be providedandcuringetc. complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLCwithSCADAenabledconcreteBatchmixplant(Panmixer)etc.complete.Withfine aggregate (Crushed sand VSI Grade) ( Basement Floor ) |
| 42 | 2.18B-( Stilt floor ) |
| 43 | 2.18C-( Ground Floor ) |
| 44 | 2.18D-( First Floor ) |
| 45 | 2.18E-( Second Floor ) |
| 46 | 2.18F-( Third Floor ) |
| 47 | 2.18G-( Fourth Floor ) |
| 48 | 2.18H-( Fifth Floor ) |
| 49 | 2.18I-( Sixth Floor ) |
| 50 | 2.19A-Providing and laying Cast in situ/ReadyMix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintelsas per detailed designs and drawingsorasdirectedincludingsteelcentering,formwork,coverblocks, laying/pumping,compactionand roughening the surface if special finish is to be provided andcuringetc.complete.(Excludingreinforcement and structural steel).with fully automaticmicroprocessorbasedPLCwith SCADAenabled concrete Batch mix plant (Pan mixer) etc.complete.Withfineaggregate (Crushed sand VSI Grade) ( Stilt floor ) |
| 51 | 2.19B-( Ground Floor ) |
| 52 | 2.19C-( First Floor ) |
| 53 | 2.19D-( Second Floor ) |
| 54 | 2.19E-( Third Floor ) |
| 55 | 2.19F-( Fourth Floor ) |
| 56 | 2.19G-( Fifth Floor ) |
| 57 | 2.19H-( Sixth Floor ) |
| 58 | 2.20A-Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ granite/ quartzite/ gneiss metal for R.C.C.slabs andlandingsasper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to beprovidedandcuringetc.complete,(Excludingreinforcementandstructural steel).withfully automaticmicroprocessorbasedPLCwithSCADA enabledconcreteBatchmixplant(Panmixer)etc.complete.Withfine aggregate (Crushed sand VSI Grade) ( Basement Floor ) |
| 59 | 2.20B-( Stilt floor ) |
| 60 | 2.20C-( Ground Floor ) |
| 61 | 2.20D-( First Floor ) |
| 62 | 2.20E-( Second Floor ) |
| 63 | 2.20F-( Third Floor ) |
| 64 | 2.20G-( Fourth Floor ) |
| 65 | 2.20H-( Fifth Floor ) |
| 66 | 2.20I-( Sixth Floor ) |
| 67 | 4.5-Providing and laying Cast in situ/ReadyMix cement concrete in M-25 of trap/ granite/quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering,formwork,coverblocks,laying/pumping, compactingandroughening them if special finish istobeprovidedandcuringcomplete.(Excluding reinforcementandstructuralsteel).with fullyautomaticmicroprocessorbasedPLC withSCADAenabledconcreteBatchmixplant(Pan mixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) ( Stilt floor ) |
| 68 | 2.21-( Ground Floor ) |
| 69 | ( Fourth Floor ) |
| 70 | ( Sixth Floor ) |
| 71 | 2.22A-Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap/ quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel Cantering, plywood/ steel formwork, steel props, laying pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including cover block). (Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) With fully automatic microprocessor based PLC with SCADA enabledconcrete Batch mix plant (Pan Mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc.) ( Basement Floor ) |
| 72 | 2.22B-( Stilt Floor ) |
| 73 | 2.22C-( Ground Floor ) |
| 74 | 2.22D-( First Floor ) |
| 75 | 2.22E-( Second Floor ) |
| 76 | 2.22F-( Third Floor ) |
| 77 | 2.22G-( Forth Floor ) |
| 78 | 2.22H-( Fifth Floor ) |
| 79 | 2.22I-( Sixth Floor ) |
| 80 | 2.23A-Providing and laying Cast in situ/ReadyMix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windowsmouldedasperdetaileddrawingsorchamferedasapprovedby theEngineer includingsteelcentering, formwork, cover blocks, laying/pumping, compacting , curing , finishing androughening them if special finish is to be provided and curingcomplete.(Excluding reinforcementandstructuralsteel).withfullyautomatic micro processor based PLC withSCADA enabledconcrete Batch mix plant (Pan mixer) etc.complete.Withfineaggregate(Crushed sand VSI Grade) ( Stilt floor ) |
| 81 | 2.23B-( Ground Floor ) |
| 82 | 2.23C( First Floor ) |
| 83 | 2.23D-( Second Floor ) |
| 84 | 2.23E-( Third Floor ) |
| 85 | 2.23F-( Fourth Floor ) |
| 86 | 2.23G-( Fifth Floor ) |
| 87 | 2.23H-( Sixth Floor ) |
| 88 | 6.7- Compound Wall ( Ground Floor ) |
| 89 | 2.24A-ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-25oftrap/ granite/gneiss/quartzitemetalforR.C.C.finsofrequiredthicknessinpositionas shown on thedrawings or as directed by Engineer-in-charge including steel centering, plywood / steelformwork, steel props, laying/pumping, compaction, finishing uneven and honeycombedsurfacewithC.M.1:3ofsufficientminimum thickness to give a smooth and even surface or roughening the surface if special finish is tobeprovidedandcuringetc.complete.(Excludingreinforcement, includingcover block)Newlylaidconcrete shallbe coveredby gunnybag, plastic, tarpaulin etc. with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( Stilt floor ) |
| 90 | 2.24B-( Ground Floor ) |
| 91 | 2.24C-( First Floor ) |
| 92 | 2.24D-( Second Floor ) |
| 93 | 2.24E-( Third Floor ) |
| 94 | 2.24F-( Fourth Floor ) |
| 95 | 2.24G-( Fifth Floor ) |
| 96 | 2.24H-( Sixth Floor ) |
| 97 | 2.25A-Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters forR.C.C.pile caps,footings,foundations,slabs,beams columns,canopies, staircase, newels,chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. ( Basement Floor ) |
| 98 | 2.25B-( Stilt floor ) |
| 99 | 2.25C-( Ground Floor ) |
| 100 | 2.25D-( First Floor ) |
| 101 | 2.25E-( Second Floor ) |
| 102 | 2.25F-( Third Floor ) |
| 103 | 2.25G-( Fourth Floor ) |
| 104 | 2.25H-( Fifth Floor ) |
| 105 | 2.25I-( Sixth Floor ) |
| 106 | 6.8-Compound Wall ( Ground Floor ) |
| 107 | 2.26A-Providingandfixinginpositiontotheexactprofileandprestressingthehightensile strandstospecifiedultimatestrength,standardendanchorages,cableducts,grouting ducts after prestressing and bearing plates with wedges as per detailed drawings including necessary plant and machinery for prestressing etc. complete. ( Stilt floor ) |
| 108 | 2.26B-( Ground Floor ) |
| 109 | 2.27-Providing,fabricatinganderecting atsiteofworkthetubularsteelstructure(shed) asper standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundationbolts, base plates,nutsandbolts, welding wherever required etc.as per detailed drawing inclusiveofonecoatof anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. One Number : As directed by Engineer-in-charge. ( Second Floor ) |
| 110 | 2.28-SupplyandInstallationofDpiFluxtranslucentroofwithstandingseammulticell polycarbonatepanelsystem.ThesystemwithcompleteassemblyofcoextrudedUV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min18 mm thick of1200mm (min.)width withangular daylighting concept. Panels shall have minimum seven layers in a truss bridge design for higher flexibility & strength. Panels with opaque and translucent clear combination as per requiredluxlevelanddesignrequirementswithallfixingaccessoriestoensurebest performanceforwinduplift,vibration,oilcanningandvisualappearance.Panelsshall haveanadditionalIRBlockingfeaturesforenhancethermalcomfort.Panelsshallbe manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed onPurlinwithsnaponconnectorswithdouble toothgrip locklocking mechanismand will be secured on MS structure (will be paid Separately) with a continuous aluminium I Beam holding the base of the standing seam along the length of the panel & fixed with purlin with self-drilling hex head screws offering best stability with a pull-out load of min. 21000N(21KN)testedasperISO6892:1998andIS1608:2005.,asperdesign requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.9 W/m2K as per EN ISO 10077-2:2018. Panel shall bewithadditionalEndcap/AluminiumU/Fprofile/GlazingBarforendsasrequired. Panel shall be fixed over MS structural steel/MSpurlin (paid separately) conforming to thedetailtechnicalspecificationsasperapprovedarchitecturaldrawings.Trainedand factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineer in charge. Colour: As per approval. The 18mm thick panels shall be used for a roofing height of upto 25 mtrs ( Second Floor ) |
| 111 | 2.29-Providing and laying damp proof course 50 mm thick in M20 cement concrete layerand bitumen / using cement with waterproofing compoundcuring, formworketc. complete. ( Ground Floor ) |
| 112 | 2.30-Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundationandplinthincluding bailingoutwatermanually strikingjoints,rackingout joints watering and scaffolding etc. complete. ( Ground Level ) |
| 113 | 2.31A-Providing Autoclaved Aerated Concrete Block masonary ofconformingtoIS:2185 (Part3)- 1984inextrafinejointingmortaroffixoblockof UltraTechor equivalentin superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) ( Basement Floor ) |
| 114 | 2.31B-( Stilt floor ) |
| 115 | 2.31C-( Ground Floor ) |
| 116 | 2.31D-( First Floor ) |
| 117 | 2.31E-( Second Floor ) |
| 118 | 2.31F-( Third Floor ) |
| 119 | 2.31G-( Fourth Floor ) |
| 120 | 2.31H-( Fifth Floor ) |
| 121 | 2.31I-( Sixth Floor ) |
| 122 | 2.32A-Providing Autoclaved Aerated Concrete Block masonaryof conformingtoIS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech orequivalentin Halfbrickthickwallincludingstrikingjoints,rakingoutjointsand scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) ( Stilt floor ) |
| 123 | 2.32B-( Ground Floor ) |
| 124 | 2.32C-( First Floor ) |
| 125 | 2.32D-( Second Floor ) |
| 126 | 2.32E-( Third Floor ) |
| 127 | 2.32F-( Fourth Floor ) |
| 128 | 2.32G-( Fifth Floor ) |
| 129 | 2.32H-( Sixth Floor ) |
| 130 | 2.33A-Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C membersandbrickwork,ofapproved qualityincluding fixing mesh in positionby necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. ( Basement Floor ) |
| 131 | 2.33B-( Stilt floor ) |
| 132 | 2.33C-( Ground Floor ) |
| 133 | 2.33D-( First Floor ) |
| 134 | 2.33E-( Second Floor ) |
| 135 | 2.33F-( Third Floor ) |
| 136 | 2.33G-( Fourth Floor ) |
| 137 | 2.33H-( Fifth Floor ) |
| 138 | 2.33I-( Sixth Floor ) |
| 139 | 2.34A-Providingandapplyinggypsumplaster(withGypsummaterial )withfinishingwith gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. ( Basement Floor ) |
| 140 | 2.34B-( Stilt floor ) |
| 141 | 2.34C-( Ground Floor ) |
| 142 | 2.34D-( First Floor ) |
| 143 | 2.34E-( Second Floor ) |
| 144 | 2.34F-( Third Floor ) |
| 145 | 2.34G-( Fourth Floor ) |
| 146 | 2.34H-( Fifth Floor ) |
| 147 | 2.34I-( Sixth Floor ) |
| 148 | 2.35A-Providinginternalcementplaster6mmthickinasinglecoatincementmortar1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.( Basement Floor )( With Sand - Crushed usded. ) |
| 149 | 2.35B-( Stilt floor )( With Sand - Crushed usded. ) |
| 150 | 2.35C-( Ground Floor )( With Sand - Crushed usded. ) |
| 151 | 2.35D-( First Floor )( With Sand - Crushed usded. ) |
| 152 | 2.35E-( Second Floor )( With Sand - Crushed usded. ) |
| 153 | 2.35F-( Third Floor )( With Sand - Crushed usded. ) |
| 154 | 2.35G-( Fourth Floor )( With Sand - Crushed usded. ) |
| 155 | 2.35H-( Fifth Floor )( With Sand - Crushed usded. ) |
| 156 | 2.35I-( Sixth Floor )( With Sand - Crushed usded. ) |
| 157 | 2.36A-Providing sand faced plaster externally in cement mortar using approved screened sand, in allpositions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 daysandkeepingthe surface of the base coat rough to receive the sand faced treatment6to8mm thickin cementmortar1:4finishingthesurfacebytakingout grainsandcuringforfourteendays scaffolding etc.complete. ( Basement Floor )( With Sand - Crushed usded. ) |
| 158 | 2.36B-( Stilt floor )( With Sand - Crushed usded. ) |
| 159 | 2.36C-( Ground Floor )( With Sand - Crushed usded. ) |
| 160 | 2.36D-( First Floor )( With Sand - Crushed usded. ) |
| 161 | 2.36E-( Second Floor )( With Sand - Crushed usded. ) |
| 162 | 2.36F-( Third Floor )( With Sand - Crushed usded. ) |
| 163 | 2.36G-( Fourth Floor )( With Sand - Crushed usded. ) |
| 164 | 2.36H-( Fifth Floor )( With Sand - Crushed usded. ) |
| 165 | 2.36I-( Sixth Floor )( With Sand - Crushed usded. ) |
| 166 | 6.10- Compound Wall ( Ground Floor )( With Sand - Crushed usded. ) |
| 167 | 2.37A-Providing and applying Texture plaster with finishing with texture materialof approved makein 3 to 4 millimeterthickness on previously plastered surface, including PlasterGroove6mm thickness or Tape Grooves 35 to 45 mm thickness or as required,inallposition including preparing the surface, scaffolding etc. complete. ( Basement Floor ) |
| 168 | 2.37B-( Stilt floor ) |
| 169 | 2.37C-( Ground Floor ) |
| 170 | 2.37D-( First Floor ) |
| 171 | 2.37E-( Second Floor ) |
| 172 | 2.37F-( Third Floor ) |
| 173 | 2.37G-( Fourth Floor ) |
| 174 | 2.37H-( Fifth Floor ) |
| 175 | 2.37I-( Sixth Floor ) |
| 176 | 6.12- Compound Wall ( Ground Floor ) |
| 177 | 2.38A-Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:4 withoutneeru finish to concrete or brick surfaces, in all positionsincluding scaffolding and curing etc. complete. ( Stilt floor )( With Sand - Crushed usded. ) |
| 178 | 2.38B-( Ground Floor )( With Sand - Crushed usded. ) |
| 179 | 2.38C-( First Floor )( With Sand - Crushed usded. ) |
| 180 | 2.38D-( Second Floor )( With Sand - Crushed usded. ) |
| 181 | 2.38E-( Third Floor )( With Sand - Crushed usded. ) |
| 182 | 2.38F-( Fourth Floor )( With Sand - Crushed usded. ) |
| 183 | 2.38G-( Fifth Floor )( With Sand - Crushed usded. ) |
| 184 | 2.38H-( Sixth Floor )( With Sand - Crushed usded. ) |
| 185 | 2.39A-ProvidingandapplyingRoyaleLuxuryEmulsionofapprovedmakeoninternalwall surface asdetailedbelowScrappingforsurfacewithemerypaperandwipeclean forarea.wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dryfor 6 to8 hoursAfter applying acrylic wall putty with appropriate prpportion of water of allow to dry for period of4to6hoursofactivity. Scrappingwithemerypaper andwipecleanApplying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45%or 65 to 70 % by roller. (With prior approval of S.E.) ( Basement Floor ) |
| 186 | 2.39B-( Stilt floor ) |
| 187 | 2.39C-( Ground Floor ) |
| 188 | 2.39D-( First Floor ) |
| 189 | 2.39E-( Second Floor ) |
| 190 | 2.39F-( Third Floor ) |
| 191 | 2.39G-( Fourth Floor ) |
| 192 | 2.39H-( Fifth Floor ) |
| 193 | 2.39I-( Sixth Floor ) |
| 194 | 2.40A-Providingandapplyingwhite-washintwocoatsonold/newplasteredormasonry surfacesandasbestoscementsheetsincludingscaffoldingandpreparingthesurfaceby brushing and brooming down etc. complete. ( Basement Floor ) |
| 195 | 2.40B-( Stilt floor ) |
| 196 | 2.40C-( Ground Floor ) |
| 197 | 2.40D-( First Floor ) |
| 198 | 2.40E-( Second Floor ) |
| 199 | 2.40F-( Third Floor ) |
| 200 | 2.40G-( Fourth Floor ) |
| 201 | 2.40H-( Fifth Floor ) |
| 202 | 2.40I-( Sixth Floor ) |
| 203 | 2.41A-Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. ( Ground Floor ) |
| 204 | 2.41B-( First Floor ) |
| 205 | 2.41C-( Second Floor ) |
| 206 | 2.41D-( Third Floor ) |
| 207 | 2.41E-( Fourth Floor ) |
| 208 | 2.41F-( Fifth Floor ) |
| 209 | 2.41G-( Sixth Floor ) |
| 210 | 2.42A-Providing andapplying one coatofsealcementprimerofapprovedmanufacture and shed includingscaffoldingpreparingthesurfacebycleaningdirtandotherforeign matters, scrapping if necessary including scaffolding etc. complete. ( Ground Floor ) |
| 211 | 2.42B-( First Floor ) |
| 212 | 2.42C-( Second Floor ) |
| 213 | 2.42D-( Third Floor ) |
| 214 | 2.42E-( Fourth Floor ) |
| 215 | 2.42F-( Fifth Floor ) |
| 216 | 2.42G-( Sixth Floor ) |
| 217 | 2.43A-Providing and applying two coats of exteriorweather shield paint of approved manufactureand of approved colour to the plastered surfaces including cleaning ,preparing the plastersurface,applyingprimercoat,scaffoldingifnecessary,and watering the surface for two days etccomplete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessary ( Basement Floor ) |
| 218 | 2.43B-( Stilt floor ) |
| 219 | 2.43C-( Ground Floor ) |
| 220 | 2.43D-( First Floor ) |
| 221 | 2.43E-( Second Floor ) |
| 222 | 2.43F-( Third Floor ) |
| 223 | 2.43G-( Fourth Floor ) |
| 224 | 2.43H-( Fifth Floor ) |
| 225 | 2.43I-( Sixth Floor ) |
| 226 | 6.13- Compound Wall ( Ground Floor ) |
| 227 | 2.44A-Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excludingthe primer coat)etc. complete. ( Basement Floor ) |
| 228 | 2.44B-( Stilt floor ) |
| 229 | 2.45A-Providingcementbasedwaterproofingtreatmenttoterraces(Indianwaterproofingor alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved waterproofingcompoundfillinguptohalfdepthofbrickbats,curingthislayerfor3 days,applyingcementslurry overthislayerjointsofbrickbatswithC.M.1:3admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing thesurfacesmoothwith cementslurryadmixed withapproved waterproofing compound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making thejunctionsattheparapetroundedandtaperedtopforrequired height, with drip mould at the junction of plaster and parapet and curing andcovering 10 years Guaranteeagainst leakproofness onCourt feestamp paperof Rs. 500/- including ponding test etc. complete. ( First Floor ) |
| 230 | 2.45B-( Second Floor ) |
| 231 | 2.45C-( Fourth Floor ) |
| 232 | 2.45D-( Fifth Floor ) |
| 233 | 2.45E-( Sixth Floor ) |
| 234 | 2.46A-ProvidingwaterproofinginW.C.andbathincludingbrickbatcobainallposition includingproviding and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab withwaterproofingcompound@1Kilogram/perbagofcementlaying brickbatcobaof requiredthicknessincm1:5 with waterproofingcompound 1 Kilogram/bagof cementgroutingandfinishingthetoplayerwith20mmthickbrick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years\" guarantee on requisite stamp paper including curing etc. complete. ( Ground Floor ) |
| 235 | 2.46B-( First Floor ) |
| 236 | 2.46C-( Second Floor ) |
| 237 | 2.46D-( Third Floor ) |
| 238 | 2.46E-( Fourth Floor ) |
| 239 | 2.46F-( Fifth Floor ) |
| 240 | 2.46G-( Sixth Floor ) |
| 241 | 2.47-ProvidingandfixingheavydutyinterlockingconcreteRubbermouldglossypaving blocksof80mmthicknessofhavingastrengthof400Kilogram/Sq.cm.ofapproved quality and shape on a bedof crushedsand of 25 to 30 mm thick including skirting joints andcleaning etc. complete. (using 100% crushed sand) ( Ground Level ) |
| 242 | 2.48A-Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick andrequiredwidthinplain/diamondpatternonbedof1:6C.M.including cement float, filling joints with neat cement slurry,curing, polishingand cleaning etc. complete. ( Ground Floor ) |
| 243 | 2.48B-( First Floor ) |
| 244 | 2.48C-( Second Floor ) |
| 245 | 2.48D-( Third Floor ) |
| 246 | 2.48E-( Fourth Floor ) |
| 247 | 2.48F-( Fifth Floor ) |
| 248 | 2.49A-Providing and laying vitrified matt fininsh tileshaving size 590 mm to 605 mm x to 605 mmof 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approvedmake, shadeandpatternforflooringinrequiredpositionlaidonabed of1:4cementmorar including neat cement float, filling joints, curing and cleaning etc. complete. ( Ground Floor ) |
| 249 | 2.49B-( First Floor ) |
| 250 | 2.49C-( Second Floor ) |
| 251 | 2.49D-( Third Floor ) |
| 252 | 2.49E-( Fourth Floor ) |
| 253 | 2.49F-( Fifth Floor ) |
| 254 | 2.49G( Sixth Floor ) |
| 255 | 2.50A-Providing and laying vitrified matt finish tileshaving size 590 mm to 605 mm x to 605 mmof 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approvedmake, shadeandpatternfordadoandskirtinginrequiredpositionfixed in1:4cementmortar including neat cement float, filling joints, curing and cleaning etc. complete. ( Ground Floor ) |
| 256 | 2.50B-( First Floor ) |
| 257 | 2.50C-( Second Floor ) |
| 258 | 2.50D-( Third Floor ) |
| 259 | 2.50E-( Fourth Floor ) |
| 260 | 2.50F-( Fifth Floor ) |
| 261 | 2.50G-( Sixth Floor ) |
| 262 | 2.51A-Providing andfixing in required positionskirting or dado of polishedKotahStone slab 25mmto30 mmthick fixed on baseon plaster of cement mortar1:4 including cement float,fillingjointswithcementslurry,curingrubbing,polishingandcleaning complete. ( Ground Floor ) |
| 263 | 2.51B-( First Floor ) |
| 264 | 2.51C-( Second Floor ) |
| 265 | 2.51D-( Third Floor ) |
| 266 | 2.51E-( Fourth Floor ) |
| 267 | 2.51F-( Fifth Floor ) |
| 268 | 2.52A-Providingandlayinginpositionflooringoftelephoneblack/AmbaWhite/Catbary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thickon bed 1:6cement mortarincluding cementfloats strikingjoints, pointingin C.M. 1:3 curing and cleaning etc. complete. ( Ground Floor ) |
| 269 | 2.52B-( First Floor ) |
| 270 | 2.52C-( Second Floor ) |
| 271 | 2.52D-( Third Floor ) |
| 272 | 2.52E-( Fourth Floor ) |
| 273 | 2.52F-( Fifth Floor ) |
| 274 | 2.52G-( Sixth Floor ) |
| 275 | 2.53A-Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to605mm x590mm to605mm of8to10mm thicknessandconfirmingtoIS. 15622-2006(groupBla)ofapprovedmake,shadeandpatternforflooringinrequired positionlaidonabedof 1:4 cement mortar including neat cement float, filling joints,curingandclearing etc. complete. ( Ground Floor ) |
| 276 | 2.53B-( First Floor ) |
| 277 | 2.53C-( Second Floor ) |
| 278 | 2.53D-( Third Floor ) |
| 279 | 2.53E-( Fourth Floor ) |
| 280 | 2.53F-( Fifth Floor ) |
| 281 | 2.54A-Providingandfixingmachinecutmachinepolished18mmto20mmthicktelephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade withfullmoulding and three grooved line forthetreadsonbedof1:4Cementmortarincludingfloatfilling jointswithneatcement slurry curing polishing and cleaningetc. complete. ( Basement Floor ) |
| 282 | 2.54B-( Stilt floor ) |
| 283 | 2.54C-( Ground Floor ) |
| 284 | 2.54D-( First Floor ) |
| 285 | 2.54E-( Second Floor ) |
| 286 | 2.54F-( Third Floor ) |
| 287 | 2.54G-( Fourth Floor ) |
| 288 | 2.54H-( Fifth Floor ) |
| 289 | 2.54I-( Sixth Floor ) |
| 290 | 2.55A-Providingandfixingmachinecutmirrorpolished18mm to20mm thicktelephone blackgranite/AmbaWhite/Catbary brown/RBI red/OceanBrowngranitestone partition with full moulding the edges etc.complete . Both side polish ( Ground Floor ) |
| 291 | 2.55B-( First Floor ) |
| 292 | 2.55C-( Second Floor ) |
| 293 | 2.55D-( Third Floor ) |
| 294 | 2.55E-( Fourth Floor ) |
| 295 | 2.55F-( Fifth Floor ) |
| 296 | 2.55G-( Sixth Floor ) |
| 297 | 2.56A-Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete ( Ground Floor ) |
| 298 | 2.56B-( First Floor ) |
| 299 | 2.56C-( Second Floor ) |
| 300 | 2.56D-( Third Floor ) |
| 301 | 2.56E-( Fourth Floor ) |
| 302 | 2.56F-( Fifth Floor ) |
| 303 | 2.57A-Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc.OnC.M.1:6includingfillingjointswithpolymerbasefillernosing/mouldingthe sharp edges wherever necessary, curing,etc. complete. ( Basement Floor ) |
| 304 | 2.57B-( Stilt floor ) |
| 305 | 2.57C-( Ground Floor ) |
| 306 | 2.57D-( First Floor ) |
| 307 | 2.57E-( Second Floor ) |
| 308 | 2.57F-( Third Floor ) |
| 309 | 2.57G-( Fourth Floor ) |
| 310 | 2.57H-( Fifth Floor ) |
| 311 | 2.57I-( Sixth Floor ) |
| 312 | 2.58A-ProvidingleatherfinishedpolishingtoGraniteStoneslabby continuousgrindingin4 coatsof different bits to receive rough and matt finish including buffing process before laying and fixingofstoneasperdrawinganddesign,includingcleaning,washing andfinishingetc. complete. ( Basement Floor ) |
| 313 | 2.58B-( Stilt floor ) |
| 314 | 2.58C-( Ground Floor ) |
| 315 | 2.58D-( First Floor ) |
| 316 | 2.58E-( Second Floor ) |
| 317 | 2.58F-( Third Floor ) |
| 318 | 2.58G-( Fourth Floor ) |
| 319 | 2.58H-( Fifth Floor ) |
| 320 | 2.58I-( Sixth Floor ) |
| 321 | 2.59A-Providing and laying ceramic tiles ofhaving size 30 cm. x 30 cm. and confirming tocorrespondingI.S.fordadoandskirtinginrequiredpositionwith readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. ( Stilt floor ) |
| 322 | 2.59B-( Ground Floor ) |
| 323 | 2.59C-( First Floor ) |
| 324 | 2.59D-( Second Floor ) |
| 325 | 2.59E-( Third Floor ) |
| 326 | 2.59F-( Fourth Floor ) |
| 327 | 2.59G-( Fifth Floor ) |
| 328 | 2.59H-( Sixth Floor ) |
| 329 | 2.60A-Providing and laying Antiskid Ceramic tiles of approved qualityof size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. ( Stilt floor ) |
| 330 | 2.60B-( Ground Floor ) |
| 331 | 2.60C-( First Floor ) |
| 332 | 2.60D-( Second Floor ) |
| 333 | 2.60E-( Third Floor ) |
| 334 | 2.60F-( Fourth Floor ) |
| 335 | 2.60G-( Fifth Floor ) |
| 336 | 2.60H-( Sixth Floor ) |
| 337 | 2.61A-Providing andconstructing granite kitchenplatform withfixing of stainlesssteelsink 600 mm x 450mm size as per detaileddrawing including vertical bothside polished kadappah stone 25 to 30 mm thick supports with kadappahtop 35 to 40 mm thick and polishedgranite16to20mm topwithsidestripsofgraniteatfrontandbothsidesof platform raised with two verticalgranitesupports15cmheightandtopgraniteof 75x40cmincludingcutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) ( Ground Floor ) |
| 338 | 2.61B-( First Floor ) |
| 339 | 2.61C-( Second Floor ) |
| 340 | 2.61D-( Third Floor ) |
| 341 | 2.61E-( Fourth Floor ) |
| 342 | 2.61F-( Sixth Floor ) |
| 343 | 2.62A-ProvidingandlayinginsitucementconcreteM20withtremixtreatmentfor100 mm thicknessforflooringwithgroovecuttingof4mmwideand20mm deepwith necessary refilling with bitumenetc. complete. ( Basement Floor ) |
| 344 | 2.62B-( Stilt floor ) |
| 345 | 2.63A-Providingandfixingfactorymadedoor/Windowframesofrequiredcolourmadewith wood Polymer composite (WPC) extuded internal ribbed sections conforming to AmericanSocietyfortestingandmaterials(ASTM)inregardwithdensity,tensile strength, flexural strength, Izod impact, water absorption and screw withdrawal strength with wall thickness of 5mm (+/1mm) and with frames having mitred joints at each corner, joinedtogether by two nos. of 10 x 8 mm & 40 mm long PVC dovetail keys including hard wood piece support along the full vertical and horizontal length in rebate portion hole forfixinghinges andfixtures andthe framesfixed toWalls/columns with15 mm long dash fasteners/holdfasts(dash fasteners/holdfaststo be paid separately) etc. complete as perthedirectionofEngineerincharge,withpriorapprovalofconcernedSuperitending Engineer.1.3 For Profile size of 125 x 50 mm with 38 x 12 mm rebate ( Stilt floor ) |
| 346 | 2.63B-( Ground Floor ) |
| 347 | 2.63C-( First Floor ) |
| 348 | 2.63D-( Second Floor ) |
| 349 | 2.63E-( Third Floor ) |
| 350 | 2.63F-( Fourth Floor ) |
| 351 | 2.63G-( Fifth Floor ) |
| 352 | 2.63H-( Sixth Floor ) |
| 353 | 2.64A-Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium platedfixturesandfastenings,withbrassmortiselock,chromiumplated handlesonboth sides, and finishing with French Polish etc. complete. ( Stilt floor ) |
| 354 | 2.64B-( Ground Floor ) |
| 355 | 2.64C-( First Floor ) |
| 356 | 2.64D-( Second Floor ) |
| 357 | 2.64E-( Third Floor ) |
| 358 | 2.64F-( Fourth Floor ) |
| 359 | 2.64G-( Fifth Floor ) |
| 360 | 2.64H-( Sixth Floor ) |
| 361 | 2.65A-Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete ( Ground Floor ) |
| 362 | 2.65B-( First Floor ) |
| 363 | 2.65C-( Second Floor ) |
| 364 | 2.65D-( Third Floor ) |
| 365 | 2.65E-( Fourth Floor ) |
| 366 | 2.65F-( Fifth Floor ) |
| 367 | 2.65G-( Sixth Floor ) |
| 368 | 2.66A-ProvidingandfixingCountry cutteak wooddouble orsingle leafpanelled shutters,35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thickandpanels without ventilator as per detailed drawing excluding the door frame, stainless steelfixturesandfasteningandfinishingthewoodworkwithoil painting 3 coats complete ( Ground Floor ) |
| 369 | 2.66B-( First Floor ) |
| 370 | 2.66C-( Second Floor ) |
| 371 | 2.66D-( Third Floor ) |
| 372 | 2.66E-( Fourth Floor ) |
| 373 | 2.66F-( Fifth Floor ) |
| 374 | 2.66G-( Sixth Floor ) |
| 375 | 2.67A-Providingandfixingfactorymadedoor/Windowframesofrequiredcolourmadewith wood Polymer composite (WPC) extuded internal ribbed sections conforming to AmericanSocietyfortestingandmaterials(ASTM)inregardwithdensity,tensile strength, flexural strength, Izod impact, water absorption and screw withdrawal strength with wall thickness of 5mm (+/1mm) and with frames having mitred joints at each corner, joinedtogether by two nos. of 10 x 8 mm & 40 mm long PVC dovetail keys including hard wood piece support along the full vertical and horizontal length in rebate portion hole forfixinghinges andfixtures andthe framesfixed toWalls/columns with15 mm long dash fasteners/holdfasts(dash fasteners/holdfaststo be paid separately) etc. complete as perthedirectionofEngineerincharge,withpriorapprovalofconcernedSuperitending Engineer.1.2For Profile size of 100 x 50 mm with 32 x 12 mm rebate ( Stilt floor ) |
| 376 | 2.67B-( Ground Floor ) |
| 377 | 2.67C-( First Floor ) |
| 378 | 2.67D-( Second Floor ) |
| 379 | 2.67E-( Third Floor ) |
| 380 | 2.67F-( Fourth Floor ) |
| 381 | 2.67G-( Fifth Floor ) |
| 382 | 2.67H-( Sixth Floor ) |
| 383 | 2.68A-Providingand fixing fiber glass reinforced polyster door shutter 30 mm thickas perIS 14856 (2000) (Reaffirmed 2006)without ventilatorincludingchromium plated fixtures and fastening with chromium plated handles on both sides, etc complete ( Stilt floor ) |
| 384 | 2.68B-( Ground Floor ) |
| 385 | 2.68C-( First Floor ) |
| 386 | 2.68D-( Second Floor ) |
| 387 | 2.68E-( Third Floor ) |
| 388 | 2.68F-( Fourth Floor ) |
| 389 | 2.68G-( Fifth Floor ) |
| 390 | 2.68H-( Sixth Floor ) |
| 391 | 2.69A-Providing & fixing factory-made Single leaf 2 hour fire rated dooras per IS 3614 Part 2 & BS 476 Part 20 & 22, tested to UL 10 C and conforming to NFPA 80 , tested at NTL /CBRI/ARAI of Plain Steel finish type with a.) Frame of size 143x58 mm and thickness of 1.6 mm thick skin pass galvanized iron sheet (Conform to IS 277 ) formed to single or double rebate profile b.) Shutter of 46 mm thickness and constructed from 1.2 mm thick skinpasgalvanizedironsheet(ConformtoIS277)infillRockwool/Mineralwool/ Honeycombcraftpaperc.)Visionglassof5mmthickclear/wiredglassCircularor Rectangulard.)Finish:Primedwithzincphosphatestovingprimerandfinishedwith Polyurethanealiphaticgradeorepoxypaintasrequiredofthickness60microne.) Accessories : Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges, Mortise sash lock with lever handle, Mortise dead bolt , Mortise latch , Door closer , Panic bar and external trim lock and Flush bolts complete. ( Ground Floor ) |
| 392 | 2.69B-( First Floor ) |
| 393 | 2.69C-( Second Floor ) |
| 394 | 2.69D-( Third Floor ) |
| 395 | 2.69E-( Fourth Floor ) |
| 396 | 2.69F-( Fifth Floor ) |
| 397 | 2.69G-( Sixth Floor ) |
| 398 | 2.70-Providing& Fixing in position Acoustical Doors alongwith 150x 150mm teakwood frame, doors made from 50mm Teak wood frame 600 x600 c to c filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides, 12mm waterproof ply & veneer from both sides , including 150mm heavy duty SS hinges (Geze / Dorma or eq.)4 noeachleaf, withDoor-closer(Dorma/Gezeoreq.) includingcostofrequiredCut- Outs,decorativemouldings/finishing-items/melaminepolish&Scaffoldingasper Architectural & Acoustical Design & Instructions & Complete in all aspects .including all materials labour,finishing etc complete ( Ground Floor ) |
| 399 | 2.70A-( First Floor ) |
| 400 | 2.71A-Providing and fixing in position powder coated aluminium louvered windows / ventilator ofvarious sizes with powder coating as per detailed drawing and specifications including aluminiumframes80x38mmx1.22mmboxtype,5mmthicksheet glasslouvers,of approved quality etc. complete. ( Stilt floor ) |
| 401 | 2.71B-( Ground Floor ) |
| 402 | 2.71C-( First Floor ) |
| 403 | 2.71D-( Second Floor ) |
| 404 | 2.71E-( Third Floor ) |
| 405 | 2.71F-( Fourth Floor ) |
| 406 | 2.71G-( Fifth Floor ) |
| 407 | 2.71H-( Sixth Floor ) |
| 408 | 2.72A-Providingand fixinginposition (asper1868/1982)Alluminiumslidingwindowof three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Runningmetre.Theshuttershouldbeof bearingbottom40x18x1.25mmat weight 0.417Kilogram/One Running Metre. Inter locking section 40x 18x 1.10mm atweight 0.469Kilogram/Running metre. andhandleandtopsection40x18x1.25mm atweight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fittedin vertical section of shutter including 5 mmthickplainglassandaluminiummosquitonetshutterwithstainless steeljailwithall required screws and nuts etc, complete. With colour Anodising with box ( Stilt floor ) |
| 409 | 2.72B-( Ground Floor ) |
| 410 | 2.72C-( First Floor ) |
| 411 | 2.72D-( Second Floor ) |
| 412 | 2.72E-( Third Floor ) |
| 413 | 2.72F-( Fourth Floor ) |
| 414 | 2.72G-( Fifth Floor ) |
| 415 | 2.72H-( Sixth Floor ) |
| 416 | 2.73A-Providingand fixing in position aluminium partly openable and partly fixed window of anysize as per detailed drawing and as directed by Engineerincharge with all necessaryalluminiumsectionsincludingnecessaryfixturesand fasteningwith 5mm thick floatglass etc.complete.a)With colour anodizingNoteWhilearrivingatthe rateofitemofitem weight at 6.90 Kilogram/ One Square Metre is considered. ( Stilt floor ) |
| 417 | 2.73B-( Ground Floor ) |
| 418 | 2.73C-( First Floor ) |
| 419 | 2.73D-( Second Floor ) |
| 420 | 2.73E-( Third Floor ) |
| 421 | 2.73F-( Fourth Floor ) |
| 422 | 2.73G-( Fifth Floor ) |
| 423 | 2.73H-( Sixth Floor ) |
| 424 | 2.74A-Providingandfixinginpositionaluminiumfixedwindowfullyglazedofanysize asper detailed drawing and as directed byEngineerincharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 mm thick clear float glass etc. complete. Note While arriving atthe rateofitem ofitem weightat6.90Kilogram/ One Square Metre is considered. a) Colour anodized(Stilt floor ) |
| 425 | 2.74B-( Ground Floor ) |
| 426 | 2.74C-( First Floor ) |
| 427 | 2.74D-( Second Floor ) |
| 428 | 2.74E-( Third Floor ) |
| 429 | 2.74F-( Fourth Floor ) |
| 430 | 2.74G-( Fifth Floor ) |
| 431 | 2.74H-( Sixth Floor ) |
| 432 | 2.75A-Providingandfixing900mmhighS.S.304GradeStainlesssteelrailingwith40mm diameter and1.5mmthickattop, 40mm diameterand1.5mm thickverticalsupports spaced at 1.5mcenter to center and 8mm thicktoughened glassincluding fabricating ,fixtures, errecting ,necessarywelding,grinding,finishing,buffingto stainless steel pipe etc. complete ( Basement Floor ) |
| 433 | 2.75B-( Stilt floor ) |
| 434 | 2.75C-( Ground Floor ) |
| 435 | 2.75D-( First Floor ) |
| 436 | 2.75E-( Second Floor ) |
| 437 | 2.75F-( Third Floor ) |
| 438 | 2.75G-( Fourth Floor ) |
| 439 | 2.75H-( Fifth Floor ) |
| 440 | 2.75I-( Sixth Floor ) |
| 441 | 2.76A-Providing and fixing during laying in RCC Slabrectangular 2 mm thickM.S. sheet fan hookboxof size180x100mmwithrequireddepthwithholesornotchesasrequired, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws togetherwith12mmdia.M.S.barbenttoshapewithhookedendsforfanhookand painting to exposed surface ( Stilt floor ) |
| 442 | 2.76B-( Ground Floor ) |
| 443 | 2.76C-( First Floor ) |
| 444 | 2.76D-( Second Floor ) |
| 445 | 2.76E-( Third Floor ) |
| 446 | 2.76F-( Fourth Floor ) |
| 447 | 2.76G-( Fifth Floor ) |
| 448 | 2.76H-( Sixth Floor ) |
| 449 | 2.77A-Providing andfixinginpositionGypsum boardfalseceilingwith 12.5mm thick Gypsumboards,screwed/fixed to the under structure of suspended G.I. Grid constructedand suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum centertocenterdistanceof600milimetreperimeterchanneland intermediate channels atmaximum center to center distance 1200 milimetre galvanizedgridshouldbefixedto reinforced cement concrete slab. The gypsum board shouldbefixedtogalvanizedirongridwithnecessaryscrews. Theboardsshouldbe taped and filled from underside to give smooth, seamless ceiling.The rateshould include necessary additional ceiling sections and intermediate channels.Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed inall respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. ( Ground Floor ) |
| 450 | 2.77B-( First Floor ) |
| 451 | 2.77C-( Second Floor ) |
| 452 | 2.77D-( Third Floor ) |
| 453 | 2.77E-( Fourth Floor ) |
| 454 | 2.77F-( Fifth Floor ) |
| 455 | 2.77G-( Sixth Floor ) |
| 456 | 2.78-Providing and Fixing ofMineral Fibre Board Acoustical Suspended Ceiling Systemwith ultima(BevelledTegular)Edge Tilesofsize 15mm ExposedGRID.The tilesshouldhave Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, ThermalConductivityk=0.052-0.057w/mK,ColourWhite,FirePerformanceUK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for GreenBuildingapplication,withRecycledcontentof32%.Thetileshallbelaidon precoated G.I.channel onXL2 Clip having a web height of 32 mm with15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200mmand600mmCrossTeeswithawebheightof32mmand aloadcarrying capacity of 7.7 Kilograms/M2 andminimum pull out strength of 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete.( Sixth Floor ) |
| 457 | 2.79A-CHANNELLED WALL PANELLING OF SIZE: 192X2400X15MM -Providing and FixingChannelled perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut,InteriorWhite,AluminaPearl)andamelaminebalancinglayeronthereverse side. The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3mm wide groove followed by 13mm or 21mmofvisiblepane(G-13/G-21).Theedgesofthepanelshallbe“tongue-and- grooved”tofixspecialclipsforinstallationandseamlessvisual.Thebackofthe perforatedpanelshallhavesoundabsorbingnon-wovenSoundtexacousticalfleecehot pressed to achieve NRC of 0.5. for G-21 and 0.6 for G-13. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 andHumidityResistance(RH)of70%withcamberlimitlessthan1mm/1000mmand bowlessthan1mm/300mOneMetricTonnehepanelsshallbemountedonspecial aluminium splines (keel) using inside clips provided by Manufacturer and approved by the Architect/ Engineer-in-Charge.Installation:Anappropriatevapourbarrier(byothers)shallbeapplied/installedonthe verticalsurfacebeforetheinstallationtoproperlysealagainstentryofanymoisture. Vapourbarrier(byothers)shallbeinstalledasperManufacturer’srecommendation. Install wooden batten grid (provided by others) of section 50x50mm or as approved by the Architecton the solid wall/partitionto provide level and plumb surface for fixing Keel. Install Keel vertically using screws and plugs at spacing of not more than 600mm centre- to-centre. The first and last keel should not be more than 150mm from the ends. Trim the tongue of the first bottom panel and install using headless nail with groove side upward. Subsequent panels are installed with tongue side downward by engaging with each other usingtongueandgroovemechanismandsecuredby insideclip.Continuethisprocess until required height is achieved. Shorter butt edges need to be joined using industrial/wood glue. The keel shall also be used for transition of the butt end of adjacent panel at every 7.2m.Install the Skirting (provided by others) of width 50mm or more as requiredbytheArchitect/Engineer-in-Charge. Finishofftheedgesusingwooden mouldingofmatchingcolour(byothers).Installationshouldbecarriedoutasper Manufacturer recommended procedure.( Ground Floor ) |
| 458 | 2.79B-( Sixth Floor ) |
| 459 | 2.80-Providing & Fixing in position, Acoustical Panelling made from Wood-wool board 20mm on, 50 x 50 mm Sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 Gsm synthetic wool 50 mm thick with chicken mesh on wall side,includingcostofrequiredCut-Outs,decorative mouldings/ finishing-items/ paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc complete( Ground Floor ) |
| 460 | 2.81-Providing & fixing in position Stage flooring Made from 18mm plywood 1200 x 2400 & 18mm Teakwood planks 100 x 800 having tongue & grove on Sal-wood frame of 50 x 100at600mmctoconstagesurfaceincludingcostofrequiredCut-Outs,decorative mouldings/finishing-items/polishetc.,asperArchitectural&AcousticalDesign& Instructions&Completeinallaspects. .includingallmaterialslabour,finishingetc complete(Ground Floor ) |
| 461 | 2.82-Providing & Fixing in position, Acoustical Ceiling made from Compressed polyester fibre nonwoven 9mmpanelson approved heavy duty GI frame 300 mm c to c & intermediate channelsat1200mmctoc, suspendedwithHangersfromRoof,includingcostof required Cut-Outs, decorative mouldings / finishing-items & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects including all materials labour,finishing etc complete (Ground Floor ) |
| 462 | 2.83A-ProvidingandFixingVerticalBlindsofapprovedMakeandshadeof100mmregular fabric with powder coated aluminium channel with teltingPVC chain & bottom weight plate with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) ( Ground Floor ) |
| 463 | 2.83B-( First Floor ) |
| 464 | 2.83C-( Second Floor ) |
| 465 | 2.83D-( Third Floor ) |
| 466 | 2.83E-( Fourth Floor ) |
| 467 | 2.83F-( Fifth Floor ) |
| 468 | 2.83G-( Sixth Floor ) |
| 469 | 2.84A-Full Height Partitions in Glass finish -Providing and Fixing 80mm to 85mm thick Full heightDouble Skin partition up to 3 mtr height with All visible sections in Anodized / Powdercoated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post made up of Aluminium Extruded and Tiles in 5mm thk. Non Toughened Glass on both side. With all the Joints in the partitions covered with PVC extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates. as per design and drawing.( Basement Floor ) |
| 470 | 2.84B-( Stilt floor ) |
| 471 | 2.84C-( Ground Floor ) |
| 472 | 2.84D-( First Floor ) |
| 473 | 2.84E-( Second Floor ) |
| 474 | 2.84F-( Third Floor ) |
| 475 | 2.84G-( Fourth Floor ) |
| 476 | 2.84H-( Fifth Floor ) |
| 477 | 2.84I-( Sixth Floor ) |
| 478 | 2.85-Providing & Fixing in position, Carpetmore than 800+ gsm, made with100% stain proof fibresofapprovedmakealongwith5mmunderlayasperArchitectural&Acoustical Design & Instructions & Complete in all aspectsincluding all materials labour,finishing etc complete( Ground Floor ) |
| 479 | 2.86-Providing & Fixing in position, 1000 mm wide Auto-glow Aluminium extruded strips on auditorium steps as per Design & Instructions & Complete in all aspects.Make Piccolo or Nexus( Ground Floor ) |
| 480 | 2.87A-FloorDirectoriesProvidingandfixingacrylicmultilingualBraille(raiseddots)ADA compliant modularfloor directories system on all floors of size1.5\" x 2\" , showing the floor plan and the list of rooms on that floor, to be installed on each floor near the staircase, designed as per standards and having 4mm thick blue acrylic base plate with Upper Case SanSerifwordsandsymbolsmadeofwhiteacrylicnonglarecutoutlettersofheight 20mm raised not less than 0.8mm above base plate and the equivalent word/s written in HindiwithDevnagrinonglareimportedacryliclettersofheight15mmraisednotless than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate.Each directory to be fixed as per manufacturers specifications on the wall at the approved location at a height of 1200mm from FFL and as per the directions by the engineer in charge.( Stilt floor ) |
| 481 | 2.87B-( Ground Floor ) |
| 482 | 2.87C-( First Floor ) |
| 483 | 2.87D-( Second Floor ) |
| 484 | 2.87E-( Third Floor ) |
| 485 | 2.87F-( Fourth Floor ) |
| 486 | 2.87G-( Fifth Floor ) |
| 487 | 2.87H-( Sixth Floor ) |
| 488 | 2.88-Providingstructuralsteelworkinhollowsectionofvariousthicknessandsizesin square, rectanular and round shape from 25mm to 450mmsection as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete.( Ground Floor ) |
| 489 | 6.14-( Ground Floor ) |
| 490 | 2.89A-Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap/ quartzite/granite /gneiss metal for R.C.C pardi of required caness including steel centering, formwork, cover blocks, laying/pumping, compacting and pune. Roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Specifications: Bd. F.11 Page No. 304 and B.7, Page No. 38 ( Basement Floor ) |
| 491 | 2.89B-( Stilt Floor ) |
| 492 | 2.89C-( Ground Floor ) |
| 493 | 2.89D-( First Floor ) |
| 494 | 2.89E-( Second Floor ) |
| 495 | 2.89F-( Third Floor ) |
| 496 | 2.89G-( Forth Floor ) |
| 497 | 2.89H-( Fifth Floor ) |
| 498 | 2.89I-( Sixth Floor ) |
| 499 | 2.91A-Providing and fixing glass door size 1.0m/1.2m x 2.7m single leaf shutter of 12 mm thick toughen glass frosting and edge polish as shown in the drawings or as directed, Including all necessary fittings like hydraulic patch fitting, top patch fittings, Top pivot, door handle, door lock, door stopper, door soft central 180 weather seal for door edges etc, complete as directed by Engineer -IN-Charge( Basement Floor ) |
| 500 | 2.91B-( First Floor ) |
| 501 | 2.91C-( Second Floor ) |
| 502 | 2.91D-( Third Floor ) |
| 503 | 2.91E-( Forth Floor ) |
| 504 | 2.91F-( Fifth Floor ) |
| 505 | 2.91G-( Sixth Floor ) |
| 506 | 2.92A-Providing and fixing double shutter glass door of required size of 12 mm thick toughen glass frosting and edge polish as shown in the drawings or as directed, including all necessary fittings like hydraulic patch fitting top patch finings, Top pivot, door handle, door lock, door stopper, door soft central 180 weather seal for door edges etc. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete.( Stilt Floor ) |
| 507 | 2.92B-( Ground Floor ) |
| 508 | 2.92C-( Second Floor ) |
| 509 | 2.92D-( Forth Floor ) |
| 510 | 2.92E-( Sixth Floor ) |
| 511 | 3.1-Providing and laying in trenches 15 mm dai. CPVC pipe including necessary excavation, fittings.Refillingtrenchesetc.completeIncluding removingexisting pipe line ifnecessary and conveying and stacking the same in PWD chowky or as directed etc. complete. ( Stilt Floor ) |
| 512 | ( Ground Floor ) |
| 513 | ( First Floor ) |
| 514 | ( Second Floor ) |
| 515 | ( Third Floor ) |
| 516 | ( Forth Floor ) |
| 517 | ( Fifth Floor ) |
| 518 | ( Sixth Floor ) |
| 519 | 3.2-Providing and laying in trenches 20 mm dai. CPVC pipe including necessary excavation,fittings.Refillingtrenchesetc.complete.Includingremovingexistingpipe line ifnecessary and conveying and stacking the same in PWD chowky or as directed etc. complete.( Stilt Floor ) |
| 520 | ( Ground Floor ) |
| 521 | ( First Floor ) |
| 522 | ( Second Floor ) |
| 523 | ( Third Floor ) |
| 524 | ( Forth Floor ) |
| 525 | ( Fifth Floor ) |
| 526 | ( Sixth Floor ) |
| 527 | 3.3-Providing and laying in trenches 25 mm dai. CPVC pipe including necessary excavation,fittings.Refillingtrenchesetc.complete.Includingremovingexistingpipe line ifnecessary and conveying and stacking the same in PWD chowky or as directed etc. complete. ( Stilt Floor ) |
| 528 | ( Ground Floor ) |
| 529 | ( First Floor ) |
| 530 | ( Second Floor ) |
| 531 | ( Third Floor ) |
| 532 | ( Forth Floor ) |
| 533 | ( Fifth Floor ) |
| 534 | ( Sixth Floor ) |
| 535 | 3.4-Providing and laying in trenches 32 mm dai. CPVC pipe including necessary excavation,fittings.Refillingtrenchesetc.complete.Includingremovingexistingpipe line ifnecessary and conveying and stacking the same in PWD chowky or as directed etc. complete. ( Stilt Floor ) |
| 536 | ( Ground Floor ) |
| 537 | ( First Floor ) |
| 538 | ( Second Floor ) |
| 539 | ( Third Floor ) |
| 540 | ( Forth Floor ) |
| 541 | ( Fifth Floor ) |
| 542 | ( Sixth Floor ) |
| 543 | 3.5-Providingand fixingon walls/ceiling/floor20 mmdia. CPVCpipewith necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. ( Stilt Floor ) |
| 544 | ( Ground Floor ) |
| 545 | ( First Floor ) |
| 546 | ( Second Floor ) |
| 547 | ( Third Floor ) |
| 548 | ( Forth Floor ) |
| 549 | ( Fifth Floor ) |
| 550 | ( Sixth Floor ) |
| 551 | 3.6-Providingandfixingonwalls/ceiling/floor25mmdia.CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. ( Stilt Floor ) |
| 552 | ( Ground Floor ) |
| 553 | ( First Floor ) |
| 554 | ( Second Floor ) |
| 555 | ( Third Floor ) |
| 556 | ( Forth Floor ) |
| 557 | ( Fifth Floor ) |
| 558 | ( Sixth Floor ) |
| 559 | 3.7-Providingandfixingonwalls/ceiling/floor32mmdia.CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.( Stilt Floor ) |
| 560 | ( Ground Floor ) |
| 561 | ( First Floor ) |
| 562 | ( Second Floor ) |
| 563 | ( Third Floor ) |
| 564 | ( Forth Floor ) |
| 565 | ( Fifth Floor ) |
| 566 | ( Sixth Floor ) |
| 567 | 3.8-Providingandfixingonwalls/ceiling/floor40mmdia.CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. ( Stilt Floor ) |
| 568 | ( Ground Floor ) |
| 569 | ( First Floor ) |
| 570 | ( Second Floor ) |
| 571 | ( Third Floor ) |
| 572 | ( Forth Floor ) |
| 573 | ( Fifth Floor ) |
| 574 | ( Sixth Floor ) |
| 575 | 3.9-Providingandfixingonwalls/ceiling/floor50mmdia.CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete. ( Stilt Floor ) |
| 576 | ( Ground Floor ) |
| 577 | ( First Floor ) |
| 578 | ( Second Floor ) |
| 579 | ( Third Floor ) |
| 580 | ( Forth Floor ) |
| 581 | ( Fifth Floor ) |
| 582 | ( Sixth Floor ) |
| 583 | 3.10-Providingandfixingonwalls/ceiling/floor15mmdia.CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.( Stilt Floor ) |
| 584 | 3.11-Providingandlayingintrenches80mmdia.heavygradehavingembossedasISI Mark galvanised iron pipes of 10.15 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.( Ground Level ) |
| 585 | 3.12-Providingandfixing45cmwidemildsteelladderof40mmx6mmmildsteelflat stringers andstepsof18mmdia.mildsteelbarforwatertankincludingfixingit in (1:2:4) M-15cement concrete block 60cm x 30cm x 30cm and painting the laddercomplete.(Anti Corossive Paint) ( Basement Floor ) |
| 586 | ( Sixth Floor ) |
| 587 | 3.13-Providingand fixing50mmdiameter water meter with non-return valveincluding strainer,sockets/unionnutandincludingwatermeterboxmakinglocking arrangementandlock. [without chamber] ( Stilt Floor ) |
| 588 | 3.14-Providingandfixing75mmdiastabiliserpipe/P.V.C.soilvent/wastepipeand withnecessaryfixturesand fittingsuchasbends,tees,singlejunctions,slottedvent, clamps etc. complete ( Stilt Floor ) |
| 589 | ( Ground Floor ) |
| 590 | ( First Floor ) |
| 591 | ( Second Floor ) |
| 592 | ( Third Floor ) |
| 593 | ( Forth Floor ) |
| 594 | ( Fifth Floor ) |
| 595 | ( Sixth Floor ) |
| 596 | 3.15-Providingandfixing100mmdiastabiliserpipe/P.V.C.soilvent/wastepipeand withnecessaryfixturesand fittingsuchasbends,tees,singlejunctions,slottedvent, clamps etc. complete. ( Stilt Floor ) |
| 597 | ( Ground Floor ) |
| 598 | ( First Floor ) |
| 599 | ( Second Floor ) |
| 600 | ( Third Floor ) |
| 601 | ( Forth Floor ) |
| 602 | ( Fifth Floor ) |
| 603 | ( Sixth Floor ) |
| 604 | 3.16-Providingandfixing8cmrigidPVCNahanitrapincludingPVCgrating,bend, connectingpieceofUPVC pipeuptotheoutsidefaceof wall,makingthegood damagedsurface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) ( Stilt Floor ) |
| 605 | ( Ground Floor ) |
| 606 | ( First Floor ) |
| 607 | ( Second Floor ) |
| 608 | ( Third Floor ) |
| 609 | ( Forth Floor ) |
| 610 | ( Fifth Floor ) |
| 611 | ( Sixth Floor ) |
| 612 | 3.17-Providingandfixing in position UPVC ultra violetstabilized 110mm outerdiameter cowldomeconfirmingtoI.S.-4985includingmakingjointswithsolventcementetc. complete( Sixth Floor ) |
| 613 | 3.18-Providing and constructing Brick MasonryInspection Chamber 90cm x 45cm x 90cmincluding 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half roundG.S.W.pipes,BrickMasonry,plasteringfrominsideandC.I.lidcoverof 75Kilogramwith lid and frame fixed in cement concrete. ( Ground Level ) |
| 614 | 3.19-ProvidingandconstructingDuctileIroncircularmanhole45cmdia.Attop90cmat bottom up to 1.80 meter to 2.70 meter depthincluding excavation,laying 1:4:8cement concrete bedding 15 cm thick burnt brick mansonry with 1:1 cement mortar plaster 25 mm thick inside and outside 20 mm (1:3) ductile iron heavy type cover with ring 125Kilograminweight.Highstrength.MorelifeandDurability,GoodAntiskidGrip, Suitable to heavy theatric loading, Light weight casting after cost benefits for TransportationRefillingetc.asperrequirement.withpriorapprovalofconcerned Superitending Engineer. ( Ground Level ) |
| 615 | 3.20-Providingand fixing15cm x10cm saltglazed stonewaregully trapin cementconcrete 1:4:8outsidethebuildingincludingcastirongratinginthesink,connectingglazed stonewarepipe,brickmasonry chamberwithcastironlidandcastirongratingforthe gully trap. ( Ground Level ) |
| 616 | 3.21-Providing , laying and fixing ,jointingEco- drain 200 mm SN 4 Nu- Drain Upvc pipes or ofequivalentmake,manufactureasperEN13476orequivalentasperI.S.15328with fittings suchabends,teestees,coupleretc,jointingwithrubberlubricantincluding necessary excavation, trench refilling with selective excavated materialetc. complete. ( Stilt Floor ) |
| 617 | 3.22-Providing andlaying castironpipesofBclassof 80mm diameter withsockets and spigotends/ flanges and cast centrifugally / vertically including specials, laying pipesandback filling the trench complete including excavation.( Stilt Floor ) |
| 618 | 3.23-ProvidingandlayingcastironpipesofBclassof100mmdiameterwithsocketsand spigot ends/ flanges and cast centrifugally/vertically including specials, laying pipes and back filling the trench complete including excavation.( Stilt Floor ) |
| 619 | 3.24-Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and havingwall thicknessof2.2to2.7mmconfirmingtoI.S.13592-1992including proper rainwaterreceivingrecesswithP.V.C.plug,bend,necessaryfittings,suchas, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket withsolventcementandproperlyrestingtheshoe ofpipesonC.C.ormasonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. ( Stilt Floor ) |
| 620 | ( Ground Floor ) |
| 621 | ( First Floor ) |
| 622 | ( Second Floor ) |
| 623 | ( Third Floor ) |
| 624 | ( Forth Floor ) |
| 625 | ( Fifth Floor ) |
| 626 | ( Sixth Floor ) |
| 627 | 3.25-ProvidingandfixingOrissatypeIvoryglazedearthenware575mmwatercloset pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside faceofthewall1:2:4brickbatlimeconcretebeddingwithoutflushingtankandits accessories etc. complete. ( Stilt Floor ) |
| 628 | ( Ground Floor ) |
| 629 | ( First Floor ) |
| 630 | ( Second Floor ) |
| 631 | ( Third Floor ) |
| 632 | ( Forth Floor ) |
| 633 | ( Fifth Floor ) |
| 634 | ( Sixth Floor ) |
| 635 | 3.26-Providing and fixing European type wall-hung Ivory water closet of approved make withpushvalveconcealedtypewithcoverplate32mmsizeofapprovedmake includingsoilpipe,vent pipe up to outside face of wall ,100mm dia. G.I. plug bendinletpipeallfittings, cuttingand making good walls, floors etc. complete.( Stilt Floor ) |
| 636 | ( Ground Floor ) |
| 637 | ( First Floor ) |
| 638 | ( Second Floor ) |
| 639 | ( Third Floor ) |
| 640 | ( Forth Floor ) |
| 641 | ( Fifth Floor ) |
| 642 | ( Sixth Floor ) |
| 643 | 3.27-Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete.( Stilt Floor ) |
| 644 | ( Ground Floor ) |
| 645 | ( First Floor ) |
| 646 | ( Second Floor ) |
| 647 | ( Third Floor ) |
| 648 | ( Forth Floor ) |
| 649 | ( Fifth Floor ) |
| 650 | ( Sixth Floor ) |
| 651 | 3.28-Providingand fixingIvoryGlazed EarthenwarefullstalltypeUrinalwith P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall( Stilt Floor ) |
| 652 | ( Ground Floor ) |
| 653 | ( First Floor ) |
| 654 | ( Second Floor ) |
| 655 | ( Third Floor ) |
| 656 | ( Forth Floor ) |
| 657 | ( Fifth Floor ) |
| 658 | ( Sixth Floor ) |
| 659 | 3.29-Providing and fixingwall hung Ivory wash basin of size550 x 400 x 195 mm withpillar cock havingflowrateupto6.0Litr/Minute,C.P.Angularstopcocklongthread of Jaquar/Cera/Hindware/Perrywareorequivalent make,includingSSbottaltrapof approved make etc complete as directed by Engineer in charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) ( Stilt Floor ) |
| 660 | ( Ground Floor ) |
| 661 | ( First Floor ) |
| 662 | ( Second Floor ) |
| 663 | ( Third Floor ) |
| 664 | ( Forth Floor ) |
| 665 | ( Fifth Floor ) |
| 666 | ( Sixth Floor ) |
| 667 | 3.30-Providingandfixingchromiumplatedtowelrod16mmdiaand75cm.inlength including all accessories complete. ( Stilt Floor ) |
| 668 | ( Ground Floor ) |
| 669 | ( First Floor ) |
| 670 | ( Second Floor ) |
| 671 | ( Third Floor ) |
| 672 | ( Forth Floor ) |
| 673 | ( Fifth Floor ) |
| 674 | ( Sixth Floor ) |
| 675 | 3.31-P / F C.P.Soap dish hooker jaquar make continental (Cat. No. AKB 35731 )(Stilt Floor) |
| 676 | 3.32-Providingandfixingstainlesssteelsinkofsize600x510x200mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. ( Ground Floor ) |
| 677 | ( First Floor ) |
| 678 | ( Second Floor ) |
| 679 | ( Sixth Floor ) |
| 680 | 3.33-ProvidingandfixingC.P.sinkcockwithraisedJ\"shapedswingingcastedspout ofapproved make including necessary sockets/ union nut etc. complete.\"( Ground Floor ) |
| 681 | ( First Floor ) |
| 682 | ( Second Floor ) |
| 683 | ( Sixth Floor ) |
| 684 | 3.34-Providing and fixing wall mixer with overhead shower,shower arm,hand shower with wall brackethaving flow rate up to 12 liters/minutesof Jaquar/Cera/Hindware /Perryware or equivalentmakeincluding allnecessarypipes,fittingsetc.completeasdirected by Engineer In Charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.)( Second Floor ) |
| 685 | 3.35-C.P.Toilet paper holder jaquar make continental (Cat. No. AQ 7751 )( Stilt Floor ) |
| 686 | ( Ground Floor ) |
| 687 | ( First Floor ) |
| 688 | ( Second Floor ) |
| 689 | ( Third Floor ) |
| 690 | ( Forth Floor ) |
| 691 | ( Fifth Floor ) |
| 692 | ( Sixth Floor ) |
| 693 | 3.36-ProvidingandFixingtoiletsetfordifferently AbledpersonsconsistofFloorMounted Ivory vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm andonenoSS304hingedrail76cms&threenoSS304of(GrabBar)60cmsall includingcuttingandmakinggoodthewallsandfloorswhereverrequired,seatcover, cistern& wash basin fittings,nuts,bolts and gasket etc complete as per the direction of Engineer-In-charge.( Stilt Floor ) |
| 694 | ( Ground Floor ) |
| 695 | ( First Floor ) |
| 696 | ( Second Floor ) |
| 697 | ( Third Floor ) |
| 698 | ( Forth Floor ) |
| 699 | 3.37-Providing andfixing 450mm x550mm size superiortype Belgium mirrorwith16mm dia. nickel plated towel rod etc. complete.( Stilt Floor ) |
| 700 | ( Ground Floor ) |
| 701 | ( First Floor ) |
| 702 | ( Second Floor ) |
| 703 | ( Third Floor ) |
| 704 | ( Forth Floor ) |
| 705 | ( Fifth Floor ) |
| 706 | ( Sixth Floor ) |
| 707 | 3.38-ProvidingandfixingDuctileironManHole Covers/Strom WaterGrating andGrating with frame of Various sizes, weight and types and load bearing capacity as per EN-124, equivalent NECOwith prior approval of concerned Superitending Engineer.( Stilt Floor ) |
| 708 | 3.39-Providing , constructing and fixing 450 mm dia. Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 mm and height of 388 mm with 160 or 200 mm main inlet (s) outlet and 110 and / or 160 mm branch inlets, with 450 mm dia. Ultra shaft pipe of HDPE material having height of 460 mm, having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick ofsize750mmdia.Includingexcavationandrefillingthesidesofchamberbysand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete. ( Stilt Floor ) |
| 709 | 3.40-Providing , constructing and fixing600 mm dia. Inspection chamber made up of Polypropylene/polyethylenematerialHaving315mmdiameter inlet(s)/outlets andwith eccentric reducers as per requirementto connect160 mm and 200 mm pipes having thickness of5mmand600mminheight,withinbuiltshaft achievetheinvertdepthaspersite condition of wall thickness of 5 mm having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc.complete. ( Stilt Floor ) |
| 710 | 3.41-RWH-ShallowPercolationPitproviding,constructing2.0mdeepshallowdepth percolationpitcomprisingof1.0mdiapre-castRCCrings,300mmthicksidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed riverfineaggregate(naturalsand/crushed sand VSI grade finely washed etc.) includingnetlonmeshbetweeneach gravel/fine aggregate (naturalsand/crushedsand VSIgradefinelywashed etc.)media layerincluding covering with RCC slab, manhole frame & cover, PVC rungs etc. includingarrangementforinlet&outlet pipe, excavation & backfilling as shown in the drawing. The rateshallbeinclusiveof alllabour, material, wastage, scaffolding, transportation, taxes, including allleads, liftsatalllevels.Allmaterialshouldbeofapprovedmake.Allworks complete as per the drawing, technical specification and direction of the Engineer in charge( Stilt Floor ) |
| 711 | 3.42-RWH - Recharge Pit Providing andconstructing rechargepitof2.0m deepand1.0m diaofpre-castRCC ringswith 6.5\"dia x 25m deep borewell at the floor of recharge pit including installation ofcombinationofsolid/perforatedPVCcasingpipewrappedaroundwith netlon mesh including 300mmthicksidefillingaroundoutsideofRCCrings(annular space)with40mmsize bouldersincludingfillingofrechargepitupto0.5mdepth with 25-75mm clean washedgravelsfrombottomupfollowedby0.5mdepthof10- 25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.)includingnetlonmeshbetweeneach gravel/fine aggregate(naturalsand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end- caps, fittings etc. including arrangement for inlet & outlet pipe excavation& backfilling asshown inthedrawing.Therateshallbeinclusiveofall labour,material,wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All materialshould beofapprovedmake.Allworkscompleteasperthe drawing,technical specification and direction of the Engineer in charge.( Stilt Floor ) |
| 712 | 3.43-Providingand laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, levelandslopeincludingnecessarycollars,excavation,laying,fixingwithcollarsin cement mortar 1:1 and refilling the trench complete.( Ground Level ) |
| 713 | 3.44-Providingand laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, levelandslopeincludingnecessarycollars,excavation,laying,fixingwithcollarsin cement mortar 1:1 and refilling the trench complete.( Ground Level ) |
| 714 | 3.45-Providingand fixing40mm.diaBallcockmediumtypewithPVCfloatincluding sockets and necessary fittings and tested as per municipal requirements etc. complete.( Stilt Floor ) |
| 715 | ( Ground Floor ) |
| 716 | ( First Floor ) |
| 717 | ( Second Floor ) |
| 718 | ( Third Floor ) |
| 719 | ( Forth Floor ) |
| 720 | ( Fifth Floor ) |
| 721 | ( Sixth Floor ) |
| 722 | 3.46-Providing , laying and fixing ,jointingEco- drain 110 mm SN 8 Nu- Drain Upvc pipes or ofequivalentmake,manufactureasperEN13476orequivalentasperI.S.15328with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete.( Stilt Floor ) |
| 723 | 3.47-Providing , laying and fixing ,jointingEco- drain 160 mm SN 4 Nu- Drain Upvc pipes or ofequivalentmake,manufactureasperEN13476orequivalentasperI.S.15328with fittings such abends,tees,coupler,etc,jointingwith rubberlubricantincluding necessary excavation, trench refilling with selective excavated materialetc. complete.( Stilt Floor ) |
| 724 | 3.48-Providing and fixing 36\" dia. FRP Cover for Underground Water tank( Ground Floor ) |
| 725 | 3.49-Providing and fixing 24\" dia. FRP Cover for Overhead Water tank( Sixth Floor ) |
| 726 | 3.50-Supplying & fixing in position galvanised iron puddle flanges of 60 cm length with flange on one / both ends and welded to mild steel plate (5mm thick) in the centre etc. complete as directed by engineer-in-charge. Flange on One End 1-50 mm dia puddle( Ground Floor ) |
| 727 | 3.51-C.P. Handshower (health faucet) 1m PVC tube with wall hook jaquar make (Cat. No. ALD 563)( Stilt Floor ) |
| 728 | ( Ground Floor ) |
| 729 | ( First Floor ) |
| 730 | ( Second Floor ) |
| 731 | ( Third Floor ) |
| 732 | ( Forth Floor ) |
| 733 | ( Fifth Floor ) |
| 734 | ( Sixth Floor ) |
| 735 | 3.52-Design, Supply, supervision of Erection & Commissioning of Sewage Treatment Plant-70 KLD-MBBR BASED Supplying, erecting and commissioning Sewage Treatment Plant including following detail with respective Capacity and following electro mechanical specification only. Designing, providing, hydraulic testing, commissioning and giving satisfactorily trials of Sewer Treatment Plant consisting of Inlet Chamber, Screen chamber, BAR SCREEN, SEWAGE WATER TRANSFER PUMP, AIR BLOWER WITH MOTOR & ACOUSTIC HOOD, DIFFUSER MEMBRANE & AIR GRID, AIR GRID WITH AIR BLOWER PIPING, MEDIA FOR BIOREACTOR (MBBR), STEEL MESH FOR AT/PERFORATED PIPE, SLUDGE TRANSFER PUMP, CHLORINE DOSING SYSTEM, FILTER FEED PUMP, PRESSURE |
| 736 | 4.1-Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterial upto distanceof50metresbeyondthebuildingareaandstackingandspreadingas directed,dewatering, preparing the bed for the foundation and necessary back filling,ramming, wateringincludingshoringandstruttingetc.complete. Including all Leads and Lift. ByMechanical Means( Ground Level ) |
| 737 | 4.4-Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations likeraft, strip foundations,grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water,Steel centering,formwork,coverblocks,laying/pumping, compaction and curingrougheningthesurfaceifspecialfinishistobeprovided (Excluding reinforcementand structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( Stilt floor ) |
| 738 | 4.6-Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C.slabs andlandingsasper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to beprovidedandcuringetc.complete,(Excludingreinforcementandstructural steel).withfully automaticmicroprocessorbasedPLCwithSCADA enabled concreteBatchmixplant(Panmixer)etc.complete.Withfine aggregate (Crushed sand VSI Grade) ( Stilt floor ) |
| 739 | ( Fourth Floor ) |
| 740 | ( Sixth Floor ) |
| 741 | 4.10-Providing and applying water proofing treatment using acrylic polymer modified cement basedwaterproofingcoatingwithfibreglassmeshmixingattherateof powdertoliquid (2:1)byweightcovering9to10SquareMetre/Kilogramwith twocoatusingapproved chemicals for masonry andconcrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.( Stilt floor ) |
| 742 | ( Fourth Floor ) |
| 743 | ( Sixth Floor ) |
| 744 | 4.11-Providingfinecement finish 1.5mmthickover greenplaster surfaceincluding scaffolding curing etc. complete.( Stilt floor ) |
| 745 | ( Fourth Floor ) |
| 746 | ( Sixth Floor ) |
| 747 | 5.1A-Executive Table @ 2250Lx2100Dx750HT including Low Height Credestal @ 1200Lx450Dx650HTProviding&FixingofTable @2250Lx2100Dx750HTTOP& GABLE END to be made ofMembrane finish with soft water fall edges & curved panel &DecoratedAnodizedsectionMODESTYPANELtobemadeof18mmthick Prelaminated particle board with PVC edge band. INCLUDING CREDESTAL @ 1200L X 450D X 650H:- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between ) as per drawing. ( Ground Floor ) |
| 748 | 5.1B-( First Floor ) |
| 749 | 5.1C-( Second Floor ) |
| 750 | 5.1D-( Third Floor ) |
| 751 | 5.1E-( Forth Floor ) |
| 752 | 5.1F-( Fifth Floor ) |
| 753 | 5.1G-( Sixth Floor ) |
| 754 | 5.2A-Pedestal Unit @ 420Lx450Dx650HT Providing&FixingofPEDESTAL@420Lx450Dx650HT:-Tobemadeoutof Complete Membrane consist of three Drawers as per drawing. ( Ground Floor ) |
| 755 | 5.2B-( First Floor ) |
| 756 | 5.2C-( Second Floor ) |
| 757 | 5.2D-( Third Floor ) |
| 758 | 5.2E-( Forth Floor ) |
| 759 | 5.2F-( Fifth Floor ) |
| 760 | 5.2G-( Sixth Floor ) |
| 761 | 5.3-Credestal @ 1200Lx450Lx650HT Providing & Fixing of LOW HEIGHT CREDESTAL @ 1200L X 450D X 650H:- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between )as per drawing.( Ground Floor ) |
| 762 | 5.4-Full Height Steel Storage @ 750Lx450Dx2100HT Providingand fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in0.8 mm thick & Topin 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing.( Ground Floor ) |
| 763 | 5.5-Providing and fixing \"Rectangular\" Shaped Full storage cabinate of sizes 1000mm x 370mm as shown in drawing, having height of 1650 mm as shown in drawing made up of 12mm/ 19mm/25mm thick plywood conforming to ISI-303 , The top 19mm thick in ply shall be finished with white uni-core laminate, 12mm/19mm thk. ply for shutter finished with white uni-core laminate, internally finished with white laminate & 50mm thk. skirting finished with powder coating on aluminum skirting matching to white uni-core laminate & veneer, all the support, horizantal members made of plywood,19mm thick finished with veneer/external surfaces with white unicore laminate, internal surfaces finished with 0.8 mm thick internal laminate, including provision for cable manager, raceways for cables and wires, ply foot rest finished with veneer, including shutters and drawers with telescopic slidersof required sizes, handles , hinges, lock, knobs, magnet, cable manager etc as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods and polishing 2 coat to all veneer and wooden surface etc.complete as directed by Engineer -In-Charge.Area using Length and Height of the unit to be measured for the payment/billing. ( Ground Floor ) |
| 764 | 5.6A-( First Floor ) |
| 765 | 5.6B-( Second Floor ) |
| 766 | 5.6C-( Third Floor ) |
| 767 | 5.6D-( Forth Floor ) |
| 768 | 5.6E-( Fifth Floor ) |
| 769 | 5.6F-( Sixth Floor ) |
| 770 | 5.8A-Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING,HIGHDENSITYCUSHIONONSEATCOMPOSITELEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. ( Ground Floor ) |
| 771 | 5.8B-( First Floor ) |
| 772 | 5.8C-( Second Floor ) |
| 773 | 5.8D-( Third Floor ) |
| 774 | 5.8E-( Forth Floor ) |
| 775 | 5.8F-( Fifth Floor ) |
| 776 | 5.8G-( Sixth Floor ) |
| 777 | 5.9A-Providing&ArrangemntofMIdBack,NormalSyncro Mechanism,FixedArmrest, Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery ( Ground Floor ) |
| 778 | 5.9B-( First Floor ) |
| 779 | 5.9C-( Second Floor ) |
| 780 | 5.9D-( Third Floor ) |
| 781 | 5.9E-( Forth Floor ) |
| 782 | 5.9F-( Fifth Floor ) |
| 783 | 5.9G-( Sixth Floor ) |
| 784 | 5.11A-Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.( Ground Floor ) |
| 785 | 5.11B-( First Floor ) |
| 786 | 5.11C-( Second Floor ) |
| 787 | 5.11D-( Third Floor ) |
| 788 | 5.11E-( Forth Floor ) |
| 789 | 5.11F-( Fifth Floor ) |
| 790 | 5.11G-( Sixth Floor ) |
| 791 | 5.12A-Sofa Set 3+1+1 Providing&fixing SofaSet3+1+1BrownandCreamleatherDIMENSIONLength: 182.5 (cms)Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat ( Fifth Floor ) |
| 792 | 5.12B-( Sixth Floor ) |
| 793 | 5.13A-Tea Table 900mm X 750mm X 450mm for m.s. ante chamber ProvidingAndFixingOfTeaTable900mmX750mmX450mmWith12mmThick ColourEitchedTemperedGlassWithBevelledDrawingMadeOut Of18mmThick WaterproofingPly.TheOuterLacesToBeFinishedWithHighQuality4MmThik Veneer Or 1 Mm Thik Mica Etc.( Ground Floor ) |
| 794 | 5.13B-( First Floor ) |
| 795 | 5.13C-( Second Floor ) |
| 796 | 5.13D-( Third Floor ) |
| 797 | 5.13E-( Forth Floor ) |
| 798 | 5.13F-( Fifth Floor ) |
| 799 | 5.13G-( Sixth Floor ) |
| 800 | 5.14-Bed Side Table @ 400LX 400DX 415H Providing and Fixing Bed Side Table of size 400LX 400DX 415H The bed side unit is madeupof18mmthickPrelamParticleBoardwithbothsidedecorativelaminate.All exposed edges are sealed with 2mm thick PVC edge Banding. The bed side table has one drawer and one shelf. The shelf is made of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding ( Second Floor ) |
| 801 | 5.15-Single Bed @ 2025LX 1000DX 650H Providing and fixing Single Bed of Size 2025Lx1000Dx650Hwith matress and pillow. Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS withathicknessof1.2mm.Thelegsshouldhavecornerbracketsweldedtoitattwo levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to jointhesidepanelsandheadboardtotheleg.Threenos.ofHorizontalstiffenersare providedatequal intervals.ThestiffenersaremadeofSquaretubeofsize25 x25mm made out of MS with a thicknessof 1.2mm.The middleHorizontal Stiffenerhas aleg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MSwithathicknessof1.2mm.AllMetalcomponentstoundergo7tanktreatment process and should be powder coated to the thickness of minimum 50 Microns DFT.Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorativelaminate.All exposededgesaresealedwith2mm thickPVCedgeBanding. The overall width of the side panel is 150mm. The side panels have 18mm thick prelam particleboardBatonrunningforrequiredlengthtoaddrigiditytothestructure.Head Board :- The head board is made up of 18mm thick Prelam Particle Board with both side decorativelaminate.All exposededgesaresealedwith2mm thickPVCedgeBanding. The head board size to be considered as 1000 x 650mm. Foot Board :- The foot board is madeupof18mmthickPrelamParticleBoardwithbothsidedecorativelaminate.All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 450mm. Bed Base: - The Bed Base is made up of 12mm thick Prelam Particle Board with both side White laminate. ( Ground Floor ) |
| 802 | 5.16-Dressing Table @400LX 400DX 1800H Providing & Fixing Dressing Table of size 400LX 400DX 1800H.The Dressing table unit is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The unit has one drawer and one shelf. The dressing table has a mirror of 4mm thick pasted on 18mm thick prelm particle board attached to the base unit. The mirror size considered is 1155 x 360 x 4(t). The mirror has been pasted using high quality 3M sticker.( Second Floor ) |
| 803 | 5.17A-Providing & Fixing Curviliner Workstation @ 1500/1500Lx600/600Dx750HT Providing&FixingCurvilinerWorkstation@1500/1500Lx600/600Dx750HT, CurvilinearTableTop@1500/1500Lx600/600D:-TOPtobemadeof25mmthick Prelaminatedparticle board with PVC edge band,GABLE END to be made of 25 mm thick Prelaminated particle board with PVC edge band, KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :-Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, along with 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, ( Fifth Floor ) |
| 804 | 5.17G-( Sixth Floor ) |
| 805 | 5.18-Kitchen Trolley ProvidingandFixingstainlesssteelkitchentrolleyofoverall26\"heightand22\" depth,supported on aluminium pipes ,trolley basket made out of 5 mm stainless steel rod fitted on telescopic channel of size 1.5 \" x 20 \" x 22 \" on both sides of trolley of 12 \" or above size, panel having 40Kilogramload bearing capacity of trolley made out of 20 mm PUCcoatedplywoodandcolourcombinationasdirectedbyE-I-C.Innersideofpanel covered by white mica ,100 mm s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge) ( Sixth Floor ) |
| 806 | 5.19-Providing & fixing in position, heavy duty fully upholstered Auditorium chairs 520 mm c to c tip-up type. Height of back should be less than 1030 mm with plastic protective cover on back and bottom having teak wood handles. Back to back distance is 1000mm. The auditoriumchairs shouldbe offollowing specifications1. PowderCoated Heavy duty MSStand.2.Individuallymoulded,ergonomicallydesigned seatandbackcushions. 3.Moulded Polyurethane Foam cushion. PU foamdensity 48 – 52 Kilograms/cu.mtr4. MouldedPolyurethaneFoammanufacturedincertifiedISO9001 facilityto ensure consistency in density for longevity .5.Upholstered in Foam laminated stretchsandwichFabricforcleanfinishandsoftcomfortablefeelasperthecolour& pattern selected by the client. 6.Seat and Back should have moulded synthetic protective cover.7.WoodenorPUarmrest 65mmx20mm -330mm long.8.Mountedusing Anchor fasteners. ( First Floor ) |
| 807 | 5.20-Executive\"sTable @ 1800Lx900Dx750HT Providing & Fixing of Table @ 1800Lx900Dx750HT - TOP & GABLE END to be made of Membranefinishwithsoftwaterfalledges&curvedpanel& DecoratedAnodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawing( Sixth Floor ) |
| 808 | 5.21-Providing and fixing conference room table top of \"C\" shape of required size having height of 0.75 m with verticle supports, footrest, architectural shape as shown in drawing made up of 12mm and 19mm thick plywood of Century make commercial ply BWR grade Conforming to ISI-303 or equivalent make, The top and facia shall be finished with solid surface 6 mm thick, veneer finish to ply surface as per detailed drawing,inner sides to be finished with 1mm thick laminate , foot rest to be finished with 0.8 mm thick laminate of royal touch or equivalent make confirming to (ISI 2046), , antitermite treatment, melamine polishing two coat to all veneersurface, fevicol, nails, cable manager,labours,materialtesting charges . All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. (NS-15 ( Second Floor ) |
| 809 | 5.22A-( Third Floor ) |
| 810 | 5.22B-( Forth Floor ) |
| 811 | 5.22C-( Sixth Floor ) |
| 812 | 5.23A-Providingand fixing Country cut teak wood partly veneered andpartly glazedpartition with 75mmx50mmframeat60cmcenterand9mmthickcommercialplyon bothsides, decorative veneer of 4 mm thick and plain glass 5 mm thick, including French polishing etc.complete ( First Floor ) |
| 813 | 5.23B-( Second Floor ) |
| 814 | 5.23C-( Third Floor ) |
| 815 | 5.23D-( Forth Floor ) |
| 816 | 5.23E-( Fifth Floor ) |
| 817 | 5.23F-( Sixth Floor ) |
| 818 | 5.24-Providing making and supplying Rostrum speech table of required size made in 19mm ply wood with laminated finish and height of 1.07 m (3\" - 6\" ) complete Including all material ,necessary arrangement , labour, taxes, etc. complete.as per details & directed by Engineer -incharge. Including Labour Cess, & Insurance. (NS-16)( First Floor ) |
| 819 | 5.25A-Providing & Arrangemnt of High Back, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery( First Floor ) |
| 820 | 5.25B-( Second Floor ) |
| 821 | 5.25C-( Third Floor ) |
| 822 | 5.25D-( Forth Floor ) |
| 823 | 5.25E-( Fifth Floor ) |
| 824 | 5.25F-( Sixth Floor ) |
| 825 | 6.4-Providingandlayinginsitu/ReadyMix cementconcrete M-20 oftrap/granite /quartzite/ gneiss metalforR.C.C.work infoundationslikeraft,stripfoundations, grillageand footingsofR.C.C.columnsandsteelstanchions etc.includingbailing outwater, Steel centeringformwork,laying/pumpingcoverblocks,compactionand curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( Ground Floor ) |
| 826 | 6.5-Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to beprovidedandcuringetc.complete.(Excludingreinforcementandstructural steel).withfully automaticmicroprocessorbasedPLCwithSCADA enabledconcreteBatchmixplant(Panmixer)etc.complete.Withfine aggregate (Crushed sand VSI Grade) ( Ground Floor ) |
| 827 | 6.6-Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite/quartzite/gneissmetal forR.C.C.beamsandlintelsasperdetaileddesignsand drawings or asdirectedincludingsteelcentering,formwork,coverblocks, laying/pumping,compactionand roughening the surface if special finish is to be providedandcuringetc. complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLCwithSCADAenabled concreteBatchmixplant(Panmixer)etc.complete.Withfine aggregate (Crushed sand VSI Grade)( Ground Floor ) |
| 828 | 6.11-Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.( Ground Floor )( With Sand - Crushed usded. ) |
| 829 | 6.15-Providingandfixingbituminouspad25mmthickforexpansionjointsinretaining wall, compound wall etc. complete. ( Ground Floor ) |
| 830 | 6.16-Providingandfixing50mm.dia.mediumclassG.I.pipegatewithwicketgateof approved drawing withallfixturesandfittingsintwoleaveswithstrong holdfast embedded inc.c. block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete.( Ground Floor ) |
| 831 | 7.1-Supplyinghardmurum/kankarattheroadsite,includingconveyingandstacking complete. |
| 832 | 7.2-Compactingthehardmurumsidewidthsincludinglayinginlayersoneachsidewith vibratory roller including artificial watering etc. complete. |
| 833 | 7.3-Constructionofgranularsub-basebyprovidingclosegradedMaterial,mixingina mechanicalmixplantatOMC,carriageofmixedMaterialtoworksite,spreadingin uniformlayerswithmotorgrader/Paveronpreparedsurfaceandcompactingwith vibratory rollertoachievethedesireddensity,completeasperclause 401-- PlantMix Method and Grading - I Material |
| 834 | 7.4-ConstructionofdryleancementconcreteSub-baseovera preparedsub-grade with coarseandfineaggregate(naturalsand/VSIgradefinelywashedcrushedsand) conformingtoIS:383,thesizeofcoarseaggregatenotexceeding25mm,,cement contentnottobelessthan150kg/cum,optimummoisturecontenttobedetermined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved byEngineer-in- charge , compacting withvibratory roller, finishing,curing andincluding preparation of sub-grade surface if required etc. complete.with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. |
| 835 | 7.5-ProvidingandfixinginpositionTMTFE500,25mmdiadowelbarsprecoatedwith anticorrosiveepoxypaintofrequiredDia.60cms.Longandat30.00cm.C/Cand wherever directedincluding handling, straightening, necessary cutting supported by TMT FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete. |
| 836 | 7.6-Providingandlayinginsitucementconcrete M-30 withtremix treatmentfor 200mm thicknessforConcreteRoadisincludinglayingplasticsheetfor125micronthickness withgroovecuttingof4mmwideand20mmdeepwithnecessaryrefillingwith polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter( excluding reinforcement)withcoarsenandfineaggregateUsingV.S.I.QualityArtifitialSandetc. complete withfullyautomaticmicroprocessorbasedPLCwithSCADAenabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. |
| 837 | 8.1-Excavation pit size 1.00 x1.00 x 1.00m for planting large flowering/ shady trees (plant height 2 to 4 mtr.)/ palm varieties of height (plant height 2 to 4 mtr.) in earth, soil of all types, soft murum, including removing the excavated &unwanted material up to a required distance of 50 mtrs( Ground Floor ) |
| 838 | 8.2-Excavation pit size 0.60 x 0.60 x 0.60m for planting small & medium ornamental plants/ large flowering/ shady trees (plant height 1 to 2 mtr.)/ palm varieties upto height 1 to 2 mtrs. in earth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 mtrs. ( Ground Floor ) |
| 839 | 8.3-Excavation pit size 0.45 x 0.45 x 0.45m for planting specimen plants in earth, soil of all types, soft murum, including removing the excavated & unwantedmaterial up to a required distance of 50 mtrs. ( Ground Floor ) |
| 840 | 8.4-Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 1 x 1 x 1m ( consolidated thickness).Quantity of soil 0.653 cum x 1000/cum = 653/-(Ground Floor ) |
| 841 | 8.5-Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 0.60 x0.60 x 0.60m ( consolidated thickness).Quantity of soil 0.1414 cum x 1000/cum= 141.40/-( Ground Floor ) |
| 842 | 8.6-Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) (i. e. 3 parts Garden soil ) for excavated pit size area of 0.45 x 0.45 x 0.45m ( consolidated thickness).Quantity of soil 0.079cum x 1000/cum = 79/-( Ground Floor ) |
| 843 | 8.7-Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 1 x 1 x 1m. ( consolidated thickness).Quantity of FYM 0.202 cum x 1200/cum = 242.40/-( Ground Floor ) |
| 844 | 8.8-Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 0.60 x 0.60 x 0.60m ( consolidated thickness).Quantity of FYM 0.044 cum x 1200/cum = 52.80/-( Ground Floor ) |
| 845 | 8.9-Supplying on site well decomposed Farm Yard Manure FYM in 3:1 proportion (i.e. 1 part FYM ) for excavated pit size area of 0.45 x 0.45 x 0.45m ( consolidated thickness).Quantity of FYM 0.023 cum x 1200/cum =27.60/-( Ground Floor ) |
| 846 | 8.10-Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species as directed etc. complete for required pit size 1.00 x 1.00 x 1.00m.( Ground Floor ) |
| 847 | 8.11-Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species as directed etc. complete for required pit size 0.60 x 0.60 x 0.60m.( Ground Floor ) |
| 848 | 8.12-Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species as directed etc. complete for required pit size 0.45 x 0.45 x 0.45m.( Ground Floor ) |
| 849 | 8.13-Filling fresh garden soil / silt & manure in excavated pit size area of 1.00 x 1.00 x 1.00m( Ground Floor ) |
| 850 | 8.14-Filling fresh garden soil / silt & manure in excavated pit size area of 0.60 x 0.60 x 0.60m( Ground Floor ) |
| 851 | 8.15-Filling fresh garden soil / silt & manure in excavated pit size area of 0.45 x 0.45 x 0.45m( Ground Floor ) |
| 852 | 8.16-Maintainance of Newly Planted tree varities having height 2mtr. - 4mtr. For First 30 days Only( Ground Floor ) |
| 853 | 8.17-Maintainance of Newly Planted tree varities having height 1mtr. - 2mtr. For First 30 days Only( Ground Floor ) |
| 854 | 8.18-Maintainance of Newly Planted small & medium size ornamental plants/ Specimen plant. For First 30 days Only( Ground Floor ) |
| 855 | 8.19-Well Developed, fresh, Healthy bright colour leves free from pest and diseasesFicus benjamina (30 cm to 60cm) 2a-12( Ground Floor ) |
| 856 | 8.20-Well Developed, fresh, Healthy bright colour leves free from pest and diseasesBougavillae Thema 30 to 50 cm 7b-10( Ground Floor ) |
| 857 | 8.21-Well Developed, fresh, Healthy bright colour leves free from pest and diseasespider lily—Hymenocallis (30 cm to 45 cm) 4-8( Ground Floor ) |
| 858 | 8.22-Well Developed, fresh, Healthy bright colour leves free from pest and diseasesFicus Golden 30 to 45 cm 2a-14( Ground Floor ) |
| 859 | 8.23-Well Developed, fresh, Healthy bright colour leves free from pest and diseasesFox tail palm 3 to 4 ft 11a-4( Ground Floor ) |
| 860 | 8.24-Well Developed, fresh, Healthy bright colour leves free from pest and diseasesAreca Palm 3 to 4 ft 11a-2 ( Ground Floor ) |
| 861 | 8.25-Well Developed, fresh, Healthy bright colour leves free from pest and diseases Kaduneem 6 to 8 ft 6b-7( Ground Floor ) |
| 862 | 8.26-Well Developed, fresh, Healthy bright colour leves free from pest and diseases Telecoma stans 50 cm to 60 cm 7c-2( Ground Floor ) |
| 863 | 8.27-Well Developed, fresh, Healthy bright colour leves free from pest and diseases Royal palm 9ft and above 11e-2( Ground Floor ) |
| 864 | 8.28-Well Developed, fresh, Healthy bright colour leves free from pest and diseases Schefflera variegated 45 cm to 60 Cm 2b-25 ( Ground Floor ) |
| 865 | 8.29-Well Developed, fresh, Healthy bright colour leves free from pest and diseases Aglaonema spp indoor plant 30 cm to 45 Cm 10b-1( Ground Floor ) |
| 866 | 8.30-Well Developed, fresh, Healthy bright colour leves free from pest and diseases Money Plant green indoor plant 10\" mostic pot 60 cm to 90 Cm10b-8( Ground Floor ) |
| 867 | 8.31-PREPARING LAWN (30 CMS. DEPTH) :- Excavating the ground to a required depth of 30 cms. Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil/silt & manure in excavated area in 3:1 proportion to a height of 30cms.Mixing garden soil and manure thoroughly, well, leveling, watering on previous night. Planting required variety of lawn grass as directed and maintaining till well established by watering, weeding, clipping, rolling etc. complete. ( Ground Floor ) |
| 868 | 8.32-PREPARING Shrubbery(30 CMS. DEPTH) :- Excavating the ground to a required depth of 30 cms. Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil/silt & manure in excavated area in 3:1 proportion to a height of 30cms.Mixing garden soil and manure thoroughly, well, leveling, watering on previous night. Planting required variety of Shrubbery as directed( spacing 30cmx30cm)and maintaining till well established by watering( upto 30 days), weeding, clipping, rolling etc. complete. ( Ground Floor ) |
| 869 | ELECTRICAL WORK -Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW |
| 870 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW |
| 871 | Secondary point wiring for additional light/bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification no. WG-PW/CW |
| 872 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW |
| 873 | Point wiring for independent plug in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW |
| 874 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BWFor Lighting Circuits. |
| 875 | Supplying and erecting mains with 1x1.5 sq.mm (E) copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BWNote:-3) Rates of earth wire shall be calculated as one half rate of mains of bunch of two wire |
| 876 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BWFor Lighting Circuits. |
| 877 | Supplying and erecting mains with 1x2.5 sq.mm (E) copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BWNote:-3) Rates of earth wire shall be calculated as one half rate of mains of bunch of two wire |
| 878 | Supplying & erecting mains with 2x4 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW |
| 879 | Supplying and erecting mains with 1x4sq.mm (E) copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BWNote:-3) Rates of earth wire shall be calculated as one half rate of mains of bunch of two wire |
| 880 | Supplying & erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BWNote:- 1) Double the rate of two wire bunch for calculating rate of four wire bunch upto 10 Sq.mm. |
| 881 | Supplying & erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BWNote:- 1) Double the rate of two wire bunch for calculating rate of four wire bunch upto 10 Sq.mm. |
| 882 | Supplying and erecting mains with 1x6sq.mm (E) copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BWNote:-3) Rates of earth wire shall be calculated as one half rate of mains of bunch of two wire |
| 883 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm(50 no. x0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 KvRemark:- ForRaw & Ups Power Sockets |
| 884 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 885 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 886 | Supplying & erecting HMS PVC conduit 25mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC. |
| 887 | Supplying & laying HMS PVC conduit 25mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification no. WG-MA/CC. |
| 888 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. withnecessary accessories in wall/floor with chiselling appropriately as perspecification No: WG-MA/CC. |
| 889 | Supplying and laying HMS PVC conduit FRLS grade 32mm dia. withnecessary accessories in RCC work/false ceiling/false flooring as per specificationNo. WG-MA/CC. |
| 890 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.(ForELV. Cables) |
| 891 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware. ForELV. Cables |
| 892 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 400 mm width & 20 mm height complete with necessary hardware.ForELE. Cables |
| 893 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 894 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 895 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete |
| 896 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 897 | Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 898 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 899 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 900 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 901 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 902 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 903 | Supplying and erecting PVC Surface modular switch box with doublemounting plate for 12 module complete. |
| 904 | Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.Remark:- ToiletDown Lights |
| 905 | Supplying and erecting LED square / circular Max. 14 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED.Remark:-Square Down Lighters |
| 906 | Supplying and erecting LED square / circular Max. 18 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B0 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 907 | Supplying and erecting LED square / circular Max. 25 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 908 | Supplying and erecting LED Panel Light (600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 909 | Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. |
| 910 | Supplying and erecting anodized aluminiummirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 911 | Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty. |
| 912 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF |
| 913 | Supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. FG-FN/CF |
| 914 | Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. |
| 915 | Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. |
| 916 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 917 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 918 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 919 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways/phase (24 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (horizontal busbar type) as per specification no. SW-MCBDB. |
| 920 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB |
| 921 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection provided on iron/GI frame as per specification no. SW-MCBDB |
| 922 | Supplying, erecting & commissioning 4 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 923 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete asper specification no. SW-RCCB/RCCB |
| 924 | Supplying, erecting & marking SP MCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 925 | Supplying, erecting & marking SP MCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 926 | Supplying and erectingGI trunking of size 100x38 mm. with accessories on wall/ceiling. |
| 927 | Supplying and erectingGI trunking of size 50x38 mm. with accessories on wall/ceiling. |
| 928 | Supplying and erectingGI Junction Box of size 450x450 mm. with accessories on wall/ceiling |
| 929 | Supplying and erectingGI Junction Box of size 220x220 mm. with accessories on wall/ceiling |
| 930 | Supplying and erectingGI Junction Box of size 150x150 mm. with accessories on wall/ceiling |
| 931 | Supplying and erectingGI Junction Box of size 100x100 mm. with accessories on wall/ceiling |
| 932 | Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230 V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) |
| 933 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 20 litres per hour and storage capacity 20 litres with partially stainless steel body As per specification no. APWCR/ WC |
| 934 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50 cycles nominal cooling capacity of 40 litres per hour and storage capacity 80 litres with partially stainless steel body As per specification No. APWCR/ WC |
| 935 | Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, withovercurrent, rated short-circuit breaking capacity (10 kA) and earth leakageprotection, with 30/100/300 mA sensitivity and short circuit and earth leakagetrip indication as per specification no SWRCCB/RCBO For Water Cooler & Water Purifier. |
| 936 | Supplying, installing, testing and commissioning of 12 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 36Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB ,MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card/chip for 5 years including net chargesfor RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract asper Specification no. ESD-RT-ONG |
| 937 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 938 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required as per specification no EA-EP. |
| 939 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 940 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 941 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (round) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 942 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 943 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 944 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CUNote:- For round wire armouring increase rates by 18%. |
| 945 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (round) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CUNote:- For round wire armouring increase rates by 18%. |
| 946 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (round) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CUNote:- For round wire armouring increase rates by 18%. |
| 947 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required as per specification no EA-EP. |
| 948 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 949 | SITC of MAIN METER PANEL-1 WING AThe panel shall be comprising of following & IEC 61439, Panel should be fully compartmentallised, wall mounted withM.S. Channel dully painted, fabricated of 14swg CRCA sheets completely derusted, chemically treated and powder coated with approved shade, ON - Off Indicating LED lamp, locking arrangements, withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage, current, frequency, power factor , ON hrs, kWh, EB and DG set metering and LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden, Surge protection device after the incoming breaker of type 1+2 for Imax 50 kA, TPN. Panel should be alongwith Mechanical and Electrical Interlock and compitable withProvided AMF Panel of 750/650 KVA DG Set, with follwing Incoming and Out going :--MainI/c 1600 Amp ACB. manual drawout type, 650V, rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA (Ics=Icu=Icw for 1s), with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display DG I/c 1600Amp ACB. manual drawout type, 650V, rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA (Ics=Icu=Icw for 1s), with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker displayBus bar chamber TPN & E withaluminium bars 1800 A. Outgoing- 400 Amp TP MCCB- 2 Nos.250 Amp TP MCCB- 1 Nos.100 Amp TP MCCB- 7 Nos.63 Amp TP MCB- 3 Nos. |
| 950 | SITC of Common Panel.The panel shall be comprising of following & IEC 61439, Panel should be fully compartmentallised, wall mounted withM.S. Channel dully painted, fabricated of 14swg CRCA sheets completely derusted, chemically treated and powder coated with approved shade, ON - Off Indicating LED lamp, locking arrangements, withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage, current, frequency, power factor , ON hrs, kWh and LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden, Surge protection device Imax 40 kA, type2, TPN as per SLD having following items:-MainI/c 400 Amp FP MCCB. Bus bar chamber TPN & E withaluminium bars Outgoing-32A TP MCB - 6 Nos.63A TP MCB- 7 Nos. 100A TP MCCB- 1 No.200A TP MCCB- 3 No.25A SP MCB - 1 Nos |
| 951 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1(WING B DB) |
| 952 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1(WING A-Floor DBs) |
| 953 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.(I/C:- WING A- 1F, 2F,3F, 5F, WING B) |
| 954 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 955 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 956 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 957 | Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP (Domestic + Flushing) |
| 958 | Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 H.P. |
| 959 | Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . |
| 960 | Supplying & erecting Dewatering Monoblock pump set 415V, 3 phase, 50C/s, A.C. supply of 2.25KW/ 3 H.P., of 12 to 26 m head with 560 to 70 LPM discharge, 10.5mm Solid Handling Capacity, non clogging minimised abrasive wear, large impeller clearance & maintenance free pump set with water proof cable duly sealed with epoxy material built in protection to prevent the motor from burn out due to abnormal operation. specially designed highefficiency motor with F class insulation & the pump mechanically sealed in the oil chamber,. etc. complete as per specification no. DWP- SMP ( Dewatering pump) |
| 961 | Supplying & erecting cast iron double flange butterfly valve of size 65 mm dia. complete as per specification no. FFVL/ BFV |
| 962 | Supplying and installing DANFOSS make pressure switch with 12/15 mm Ø isolation valve, G.I. nipple, elbow etc. in an approved manner as per specification No. FF-FFA/PS(For work within pump room) |
| 963 | Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc. as per requirement in an approved manner as per specification No. FF-FFA/PG(For work within pump room) |
| 964 | Supplying and erecting 20/25mm Ø G.M.air release cock (ARV), with necessary G.I. coupling to be fitted on top of Air vessel or on wet riser as per specification No. FF-FFA/ARV (For work within shaft & pump Room) |
| 965 | Supplying and erecting 250 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC |
| 966 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 967 | Making M-20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal/conical GI pole). |
| 968 | Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 969 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. |
| 970 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 971 | Supplying and erecting PVC insulated PVC round sheathed FR 1.5 sq.mm (30 no. x 0.25mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kV |
| 972 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 973 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cmcomplete with all materials, testing & recording the results as per specification no. EA-EP |
| 974 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required as per specification no EA-EP.(25 mm X 3 mm Strip) |
| 975 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 976 | Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 977 | Supplying, erecting & marking SP MCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 978 | SITC of Electric Traction Passenger Lift with• Rated capacity :- 13 Passenger/884Kg• Floors :- G+2 floor ( Stilt+Gr.+1= 3 Landing)• Travel :- 3 to 4.2 mtrs.• Location of Lift Machine:- MR/MRL• Rated speed :- 1.0mps VS• Car/Landing door clear opening of 900/1000 mm wide x 2000 mmhigh• Clear Car size of 1550mm wide x 2200mm deep x 2250mm high• Lift shaft available having clear size of 1700 mm wide x 2500 mm deep, 1500mm Pit depth, 4500mm Overhead.• Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).• Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.• LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.• Lift controller of simplex full collective based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motorand travel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. •• ARD complete with necessary SMF VRLA batteries.• Fireman controller having fireman switch at fire Landing.• CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18 FHD TV monitor, to be kept inFCC/LMR as directed by Engineer In Charge.• Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.• Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.Minor civil work such as alteration work if any necessary for erection oflanding door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.• General: - Job includes entire procedure of obtaining all necessary erection permissions & License to Work the Lift from Electrical Inspector(Lifts) with submission to the Engineer In Charge.• The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. |
| 979 | SITC of Electric Traction Passenger Lift with• Rated capacity :- 13 Passenger/884Kg• Floors :- G+8 floor ( B+Stilt+Gr.+6= 9 Landing)• Travel :- 21 to 29.4 mtrs• Location of Lift Machine:- MR/MRL• Rated speed :- 1.5mps VS• Car/Landing door clear opening of 900/1000 mm wide x 2000 mmhigh• Clear Car size of 1550mm wide x 2200mm deep x 2250mm high• Lift shaft available having clear size of 1700 mm wide x 2500 mm deep, 1500mm Pit depth, 4500mm Overhead.• Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).• Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.• COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.• LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.• Lift controller of simplex full collective based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motorand travel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. •• ARD complete with necessary SMF VRLA batteries.• Fireman controller having fireman switch at fire Landing.• CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18 FHD TV monitor, to be kept inFCC/LMR as directed by Engineer In Charge.• Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.• Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.Minor civil work such as alteration work if any necessary for erection oflanding door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.• General: - Job includes entire procedure of obtaining all necessary erection permissions & License to Work the Lift from Electrical Inspector(Lifts) with submission to the Engineer In Charge.• The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. |
| 980 | SITC of Electric Traction Passenger Lift with• Rated capacity :- 13 Passenger/884Kg• Floors :- G+8 floor ( B+Stilt+Gr.+6= 9 Landing)• Travel :- 21 to 29.4 mtrs• Location of Lift Machine:- MR/MRL• Rated speed :- 1.5mps VS• Car/Landing door clear opening of 900/1000 mm wide x 2000 mm high• Clear Car size of 1550mm wide x 2200mm deep x 2250mm high• Lift shaft available having clear size of 1700 mm wide x 2500 mm deep, 1500mm Pit depth, 4500mm Overhead.• Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).• Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.• COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.• LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.• Lift controller of simplex full collective based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motorand travel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. •• ARD complete with necessary SMF VRLA batteries.• Fireman controller having fireman switch at fire Landing.• CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18 FHD TV monitor, to be kept inFCC/LMR as directed by Engineer In Charge.• Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.• Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.• Minor civil work such as alteration work if any necessary for erection oflanding door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.• General: - Job includes entire procedure of obtaining all necessary erection permissions & License to Work the Lift from Electrical Inspector(Lifts) with submission to the Engineer In Charge.• The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. |
| 981 | SITC of Duplex Lift control system for two nos. microprocessor/PLC basedsimplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete. |
| 982 | SITC of Electric Traction Passenger Lift with• Rated capacity :- 13 Passenger/884Kg• Floors :- G+7 floor ( B + Stilt+Gr.+5 = 8 Landing)• Travel :- 21 to 29.4 mtrs• Location of Lift Machine:- MR/MRL• Rated speed :- 1.5mps VS• Car/Landing door clear opening of 900/1000 mm wide x 2000 mmhigh• Clear Car size of 1550mm wide x 2200mm deep x 2250mm high• Lift shaft available having clear size of 1700 mm wide x 2500 mm deep, 1500mm Pit depth, 4500mm Overhead.• Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).• Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.• COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.• LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.• Lift controller of simplex full collective based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motorand travel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. •• ARD complete with necessary SMF VRLA batteries.• Fireman controller having fireman switch at fire Landing.• CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18 FHD TV monitor, to be kept inFCC/LMR as directed by Engineer In Charge.• Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.• Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.• Minor civil work such as alteration work if any necessary for erection oflanding door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.• General: - Job includes entire procedure of obtaining all necessary erection permissions & License to Work the Lift from Electrical Inspector(Lifts) with submission to the Engineer In Charge.• The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. |
| 983 | SITC of Electric Traction Passenger Lift with• Rated capacity :- 10 Passenger/680Kg• Floors :- G+7 floor( Stilt+Gr.+6= 8 Landing)• Travel :- 21 to 29.4 mtrs• Location of Lift Machine:- MR/MRL• Rated speed :- 1.5mps VS• Car/Landing door clear opening of 800 mm wide x 2000 mm high• Clear Car size of 1350mm wide x 1550mm deep x 2250mm high• Lift shaft available having clear size of 1500 mm wide x 1800 mm deep, 1500mm Pit depth, 4500mm Overhead.• Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).• Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.• COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.• LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.• Lift controller of simplex full collective based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motorand travel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. •• ARD complete with necessary SMF VRLA batteries.• Fireman controller having fireman switch at fire Landing.• CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18 FHD TV monitor, to be kept inFCC/LMR as directed by Engineer In Charge.• Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.• Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.• Minor civil work such as alteration work if any necessary for erection oflanding door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.• General: - Job includes entire procedure of obtaining all necessary erection permissions & License to Work the Lift from Electrical Inspector(Lifts) with submission to the Engineer In Charge.• The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. |
| 984 | SITC of Electric Traction Passenger Lift with• Rated capacity :- 13 Passenger/884Kg• Floors :- G+6 floor (B+ Stilt+Gr.+4= 7 Landing)• Travel :- 3 to 4.2 mtrs.• Location of Lift Machine:- MR/MRL• Rated speed :- 1.0mps VS• Car/Landing door clear opening of 900/1000 mm wide x 2000 mmhigh• Clear Car size of 1550mm wide x 2200mm deep x 2250mm high• Lift shaft available having clear size of 1700 mm wide x 2500 mm deep, 1500mm Pit depth, 4500mm Overhead.• Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).• Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.• COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.• LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.• Lift controller of simplex full collective based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motorand travel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. •• ARD complete with necessary SMF VRLA batteries.• Fireman controller having fireman switch at fire Landing.• CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18 FHD TV monitor, to be kept inFCC/LMR as directed by Engineer In Charge.• Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.• Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.• Minor civil work such as alteration work if any necessary for erection oflanding door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.• General: - Job includes entire procedure of obtaining all necessary erection permissions & License to Work the Lift from Electrical Inspector(Lifts) with submission to the Engineer In Charge.• The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.· |
| 985 | Supplying and erecting single pole and neutral distribution board (SPNDB),with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, withdoor, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GIframe as per specification no. SW-SWR/MCBDB |
| 986 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 987 | Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent,rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 988 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 989 | Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB |
| 990 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB |
| 991 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB |
| 992 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 993 | Supplying and erecting modular type 3 pin 6A multi socket with safetyshutter, duly erected on provided plate and box with wiring connectionscomplete |
| 994 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 995 | Supplying and erecting PVC Surface modular switch box with doublemounting plate for 4 module duly erected. |
| 996 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW |
| 997 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 998 | Supplying and erecting CRCA powder coated corridor/passage light LEDfitting (4 feet) Max. 17W with high transitivity diffuser with system lumensoutput of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCTupto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 999 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected,complete |
| 1000 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 1001 | Supplying and erecting mains with 1x1.5 sq.mm(E) FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW Note:-3) Rates of earth wire shall be calculated as one half rate of mains of bunch of two wire |
| 1002 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copperconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 1003 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (round) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CUNote:-For round wire armouring increase rates by 18%. |
| 1004 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CUNote:- For round wire armouring increase rates by 18%.(For Wing B Lift ) |
| 1005 | Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 1006 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP.(25 mm X 3 mm) |
| 1007 | \"Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camerawith following features Image Sensor : minimum 1/2.8\"\" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individuallyconfigurable stream,Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant,minimum IR distance : 50m,Lens Type : 2.8/4/6 mm Lens, fixed focal,Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m.Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°.Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant.Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1.Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation\"\"Events : Privacy Masking, Motion detection, Scene change detection, Facecapture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol.RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalentBIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc completeCCTV-CAM with 3 Years warranty.\" |
| 1008 | \"Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camerawith following featuresImage Sensor : minimum 1/2.8\"\" Progressive Scan CMOS,Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individuallyconfigurable stream,Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant,minimum IR distance : 50m,Lens Type : 2.8/4/6 mm Lens, fixed focal,Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°.Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.\"\"Events : Privacy Masking, Motion detection, Scene change detection, Facecapture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete with 3 Years warranty. \" |
| 1009 | Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS |
| 1010 | Supplying, installing, testing & commissioning of 64/80 Ch Network VideoRecorder (NVR), suitable connect Min. 64 IP Cameras, up to 5 MegapixelResolution, with HDMI 1/VGA 1 and HDMI 2/VGA 2 outputs provided,Atleast one HDMI output of 4K resolution, atleast one VGA output with output up to 1920 × 1080, Support H.265 or higher, H.264, MJPEG,Supports Redundant Dual Power, Incoming Bandwidth 320 Mbps with minimum 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps selfadaptive Ethernet interface, support multi brand network Cameras, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. complete with 3 Years warranty |
| 1011 | Supplying, installing, testing & commissioning of 32/40 Ch Network VideoRecorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 MegapixelResolution, with HDMI1/VGA1 outputs, provided Atleast one HDMI output of 4K resolution, atleast one VGA output with output up to 1920x1080, Support H.265 or higher, H.264, MJPEG, Supports Redundant Dual Power, Incoming Bandwidth 320 Mbps with minimum 8 SATA ports, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps selfadaptive Ethernet interface, support multibrand network Cameras,ONVIF conformance, Multiple network monitoring: Web viewer .support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS,iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging andprogramming etc. complete with 3 Years warranty |
| 1012 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x550x347 mm) as per specification no. WG-NAS/RAK For POE Switches. |
| 1013 | Supplying and fixing 12U wall mount rack (Dimension-DxWxH – 500x550x613 mm) as per specification no. WG-NAS/RAKMain CCTV Rack |
| 1014 | Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR complete with 3 Years warranty |
| 1015 | Supplying and fixing 1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-D in position as per specification No. WG-COC/PC |
| 1016 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 1017 | Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. |
| 1018 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 1019 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. withnecessary accessories in wall/floor with chiselling appropriately as perspecification No: WG-MA/CC. |
| 1020 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 1021 | Supplying & erecting 55\" professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following featuresBrightness: minimum 500 Cd/m2Contrast Ratio: minimum 1000:1Viewing angle: 178/178 deg.Response time: maximum 8 msInputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W,Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle dulyerected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete with 3 Years warranty |
| 1022 | Supplying and erecting 10m HDMI cord low voltage grade minimum 4kcompliant to be laid in provided conduits with male/female 19 pin HDMIconnectors complete. |
| 1023 | Supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kVA capacity online pure sine wave UPS, with backup time of 0.5hrs. PWM & IGBT based, with 0.8 to unity output pf complete with all protections as per specification no. AP-UPS |
| 1024 | Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete |
| 1025 | Supplying, fixing, and configuring 24-port 10/100M un-managed 10/100/1000 base-T gigabit switch compliant with IEEE 802.3 standards as per specification complete. |
| 1026 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x550x347 mm) as per specification no. WG-NAS/RAK |
| 1027 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 1028 | Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 1029 | Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. |
| 1030 | Supplying and installing cat-6 cable suitable for networking as per specificationno. WG-COC/NC |
| 1031 | Supplying and fixing 1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-D in position as per specification No. WG-COC/PC |
| 1032 | Supplying and fixing Power Distribution Unit for networking rack comprises of 6/16A (6 Nos. sockets), 25 A modular MCB, appropriate rating fuse and indicator lamp, enclosed in black powder coated metal with necessary arrangement for fixing as per specification No. WG-NAS/RAK |
| 1033 | Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 1034 | Supplying, erecting & terminating 20 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing-n-capping/conduit as per specification no. WG-TW |
| 1035 | Supplying & erecting 50 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 1036 | Supplying & erecting 100 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 1037 | Supplying, erecting & commissioning 20 pairs FR junction box with mouldedplastic enclosure as per specification no. WG-TW |
| 1038 | Supplying, erecting & commissioning 100 pairs M.S. junction box made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 1039 | Supplying, erecting & commissioning 50 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 1040 | Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete.Note :- 1) Add Rs. 38159.00 for additional 16 extension card for digital (hybrid) type EPABX (3 Nos of 16 extension cards for Each EPABX) |
| 1041 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 1042 | Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete. |
| 1043 | Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete |
| 1044 | Supplying and fixing 12U wall mount rack (Dimension-DxWxH – 500x600x635mm) as per specification No. WG-NAS/RAK(For Networking,EPABX , Amplifier ) |
| 1045 | Supply, Installation, Testing and Commissioning of Projector. 6,000 lumens colour/white brightness. WUXGA, widescreen images up to 500\" — WUXGA resolution (1920 x 1200); Full HD 1080p support. Breakthrough laser technology, features a laser light source of up to 20,000 hours, plus, Instant ON/OFF. Virtually maintenance-free operation for the life of the optical engine. Extraordinary sharpness and detail — up to 2,500,000:1 Dynamic contrast ratio. |
| 1046 | Supply, Installation, Testing and Commissioning of Projector Screen 109\" MOTORIZED SCREEN. deal for applications where a recessed installation is not desired or feasible. Patented in-the-roller motor mounting system for quiet operation. Handsome white case blends with any decor. Built-in low voltage control and silent motor option available. Installation Easy to use and it comes with standard installation brackets that can wall or ceiling mounted. Tubular Motor (230 Volts) Utilizing a high quality tubular motor, it is easy to adjust the up/down limits. The overhead protection design ensures added safety when using the screen |
| 1047 | Supplying erecting of Projector Ceiling / Wall mounting kit |
| 1048 | Supplying and erecting modular pop up Box 8 module erected with provided AV/ HDMI , RJ 45,6 A electrical sockets and switch on provided table. |
| 1049 | Supplying and erecting 15m HDMI cord low voltage grade minimum 4kcompliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 1050 | Supplying and erecting 25m HDMI cord low voltage grade minimum 4kcompliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 1051 | Supplying, erecting, testing & commissioning Mixer Amplifier 500W RMS Power with Built-in Digital Player with remote and having 7 Mic & 3 Aux Inputs with Box Speaker/Driver Unit selector switch to each zone , stereo/mono switch, frequency response 50-15000Hz, output regulation <2dB, serprate control for USB level. The unit shall have Preamplifier and Line Output for connecting to a Booster Amplifier and for recording the programme with Resettable circuit breaker for protection against overload and short circuit. The unit shall have speaker output range of 2Ω, 4Ω/(Low Impedence) and 70V & 100V/(High Impedence) & It can instant transfer to DC power(36V) if AC power fails. Signal to noise ratio between 60dB to 80dB. Complete as per specification no. PA-MA |
| 1052 | Supplying, installing, testing & commissioning 2-Way flush mount Ceiling Speakers with input power 30W RMS power, with power taps on 30/15/7.5W, 100V & 70V line, frequency response 90-18000Hz, stylish metal mesh grill and plastic frame, operates on 100V line for excellent reproduction of both speech and music, wide frequency response and adjustable tweeter complete as per specification no. PA-FMCS |
| 1053 | Supplying, installing, testing and commissioning 30W PA Column Speakers with 30W RMS power in aluminium extruded cabinet, Moulded Plastic Covers & Metal mesh grill, 100V transformer with rotary switch for power tap selection, frequency response 150-10,000Hz, with power taps of 30/20/10/5 W in black or white color as per the decision of Engineer-in charge, complete with mounting clamps & necessary hardware complete as per specification no. PA-CS |
| 1054 | Supplying, erecting, testing and commissioning PA Mixer 10 channel with MP3 Player with USB/SD card reader and Bluetooth facility, 48V Phantom Supply on 4 Channels, 8 MIC/LINE Balanced Mono input channels, 1 Stereo balanced input channel in 2 selectable sensitivities of -10dBu & +4dBu, Frequency Responce : 25Hz - 20kHz,Impedance : 600Ω,Signal to noise ratio : >70dB,Operates on 240V 50Hz AC supply, built-in Digital Effects processor with Delay, Repeat and Level controls. Each input channel has a GAIN control, 3 band active Equalizer controls, a Pre-fader AUX1 control, a Post-fader AUX2 /EFX control & a PAN control, STEREO channel has a GAIN control, 2 band active Equalizer controls, AUX1 Pre fader control, AUX2/EFX Post fader control and a BALANCE control with Channel ON/OFF switch provided on each individual channel, complete as per specification no. PA-MXR |
| 1055 | Supplying, Installing, testing and commissioning of Dual channel UHFwireless microphone & receiver, including 2 handheld dynamic transmitters with operating range of minimum 30 mtr distance in line of sight between transmitter & receiver and with 2 x 1.5V batteries of suitable size and and Current consupmtion <150mA, RF power output 10mW or higher suitable for frequency stability +/-0.005%, frequency response 50-15000Hz, channel frequency display & receiver with 220V-240V AC 50Hz AC Adaptor, distortion - /< 1% S/N ratio 100 dB suitable for same frequency as transmitter having controls like ON/OFF Switch, Volume control for both channels, LED indicators for RF & Audio Signal, channel frequency displays & operates on 12V DC through an AC adaptor complete as per specification no. PA-DPA-UHF |
| 1056 | Supplying, erecting, testing and commissioning of multistrand annealed bare copper conductor, transparent PVC insulated 2C x 1.5 sqmm speaker wire in provided trunking/conduit etc.complete as per specification no. PA-TSPWR |
| 1057 | Supplying and erecting 15m Audio Video cord low voltage grade as perspecification with required 3RCA x 3RCA connector complete. |
| 1058 | Supplying, erecting, testing and commissioning of 2kVA capacity online pure sine wave, with backup time of 0.5hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS |
| 1059 | Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete |
| 1060 | Supplying and erecting PVC Surface modular switch box with doublemounting plate for 6 module duly erected. |
| 1061 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 1062 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete |
| 1063 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 1064 | Supplying and erecting mains with 1x2.5 sq.mm (E) copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BWNote:-3) Rates of earth wire shall be calculated as one half rate of mains of bunch of two wire |
| 1065 | Supplying & erecting HMS PVC conduit 25mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC. |
| 1066 | Supplying & laying HMS PVC conduit 25mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification no. WG-MA/CC. |
| 1067 | Supplying and erecting LSZH armoured multimode optical fibre cable with 24 fibres, core dia 50/125 μm (OM3), suitable up to 10 GBPS ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC |
| 1068 | 5 Supplying, erecting, testing and commissioning of 14HP, VRF/VRV airconditioning system outdoor unit (ODU) complies type-IV OEMstandards working on HFC refrigerant R410A or other required/suitablegreen equivalent refrigerant, for minimum cooling capacity as delivering 100%capacity at 47° C, non stop cooling even at 56° C and coefficient of performance(COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longerpiping range upto 1000 metre operation in cooling mode with inverter/digitalVRF/VRV technology microprocessor based control compressor starter/controlpanel with scroll compressor, air cooled copper condenser coil of suitable shapefor increasing maximum heat transfer area, rain protection cover, built in oilseparator, accumulator and oil receiver, copper tube aluminium fin air cooledcondenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phasepower supply (all suitable for high ambient conditions), internal copper refrigerantpiping, internal wiring and refrigerant, etc. all housed in powder coated weatherproof cabinet complete. |
| 1069 | Supplying, erecting, testing and commissioning of 18HP, VRF/VRV airconditioning system outdoor unit (ODU) complies type-IV OEMstandards working on HFC refrigerant R410A or other required/suitablegreen equivalent refrigerant, for minimum cooling capacity as delivering 100%capacity at 47° C, non stop cooling even at 56° C and coefficient of performance(COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longerpiping range upto 1000 metre operation in cooling mode with inverter/ digitalVRF/VRV technology microprocessor based control compressor starter/controlpanel with scroll compressor, air cooled copper condenser coil of suitable shapefor increasing maximum heat transfer area, rain protection cover, built in oilseparator, accumulator and oil receiver, copper tube aluminium fin air cooledcondenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phasepower supply (all suitable for high ambient conditions), internal copper refrigerantpiping, internal wiring and refrigerant, etc. all housed in powder coated weatherproof cabinet complete. |
| 1070 | Supplying, erecting, testing and commissioning of 24HP, VRF/VRV airconditioning system out door unit (ODU) complies type-IV OEMstandards working on HFC refrigerant R410A or other required/suitablegreen equivalent refrigerant, for minimum cooling capacity as delivering 100%capacity at 47° C, non stop cooling even at 56° C and coefficient of performance(COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longerpiping range upto 1000 metre operation in cooling mode with inverter/digitalVRF/VRV technology microprocessor based control compressor starter/controlpanel with scroll compressor, air cooled copper condenser coil of suitable shapefor increasing maximum heat transfer area, rain protection cover, built in oilseparator, accumulator and oil receiver, copper tube aluminium fin air cooledcondenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phasepower supply (all suitable for high ambient conditions), internal copper refrigerantpiping, internal wiring and refrigerant, etc. all housed in powder coated weatherproof cabinet complete. |
| 1071 | Supplying, erecting, testing and commissioning of 26HP, VRF/VRV airconditioning system out door unit (ODU) complies type-IV OEMstandards working on HFC refrigerant R410A or other required/suitablegreen equivalent refrigerant, for minimum cooling capacity as delivering 100%capacity at 47° C, non stop cooling even at 56° C and coefficient of performance(COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longerpiping range upto 1000 metre operation in cooling mode with inverter/digitalVRF/VRV technology microprocessor based control compressor starter/controlpanel with scroll compressor, air cooled copper condenser coil of suitable shapefor increasing maximum heat transfer area, rain protection cover, built in oilseparator, accumulator and oil receiver, copper tube aluminium fin air cooledcondenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phasepower supply (all suitable for high ambient conditions), internal copper refrigerantpiping, internal wiring and refrigerant, etc. all housed in powder coated weatherproof cabinet complete. Supplying, erecting, testing and commissioning of 28HP, VRF/VRV airconditioning system outdoor unit (ODU) complies type-IV OEMstandards working on HFC refrigerant R410A or other required/suitablegreen equivalent refrigerant, for minimum cooling capacity as delivering 100%capacity at 47° C, non stop cooling even at 56° C and coefficient of performance(COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longerpiping range upto 1000 metre operation in cooling mode with inverter/digitalVRF/VRV technology microprocessor based control compressor starter/controlpanel with scroll compressor, air cooled copper condenser coil of suitable shapefor increasing maximum heat transfer area, rain protection cover, built in oilseparator, accumulator and oil receiver, copper tube aluminium fin air cooledcondenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phasepower supply (all suitable for high ambient conditions), internal copper refrigerantpiping, internal wiring and refrigerant, etc. all housed in powder coated weatherproof cabinet complete. |
| 1072 | Supplying, erecting, testing and commissioning of 28HP, VRF/VRV airconditioning system outdoor unit (ODU) complies type-IV OEMstandards working on HFC refrigerant R410A or other required/suitablegreen equivalent refrigerant, for minimum cooling capacity as delivering 100%capacity at 47° C, non stop cooling even at 56° C and coefficient of performance(COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longerpiping range upto 1000 metre operation in cooling mode with inverter/digitalVRF/VRV technology microprocessor based control compressor starter/controlpanel with scroll compressor, air cooled copper condenser coil of suitable shapefor increasing maximum heat transfer area, rain protection cover, built in oilseparator, accumulator and oil receiver, copper tube aluminium fin air cooledcondenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phasepower supply (all suitable for high ambient conditions), internal copper refrigerantpiping, internal wiring and refrigerant, etc. all housed in powder coated weatherproof cabinet complete. |
| 1073 | Supply, installation, testing and commissioning of VRF/VRV based Hi-walltype indoor unit (IDU) of nominal cooling capacity 1.8TR (594 cfm) to2.2TR (655 cfm) having EER as per BEE standards and specifications withmultiple speed evaporator fan with motor, copper tube aluminium fin evaporatorcoil, washable air filter, insulated drain tray, expansion device, cordless remotecontrol with necessary controls, with 3-core copper flexible cord of requiredlength and electrical terminal to receive power supply, etc. IDU shall haveanticorrosive coating suitable for coastal area. Unit shall be suitable for indoorwall mounting, having an electronic control console, provided with suitablemounting brackets with any additional refrigerant and oil charge as per therequirement during installation, connected to the system complete |
| 1074 | Supply, installation, testing and commissioning of VRV / VRF based ductabletype, high static indoor unit (IDU) having nominal cooling capacity of3.1TR ( 1240 cfm )to 4.0TR ( 1600 cfm ) having EER as per BEE standardsand specifications with evaporator fan with motor, copper tube aluminium finevaporator coil, washable air filter, insulated drain tray, expansion device, cordlessremote control with necessary controls and electrical terminal to receive powersupply, etc. having anti-corrosive coating suitable for coastal area, with suitableceiling suspension arrangement, with an electronic control console and anyadditional refrigerant and oil charge as per requirement during installationconnected with the system complete. |
| 1075 | Supply, installation, testing and commissioning of VRV / VRF based ductabletype, high static room/indoor unit (IDU) having nominal cooling capacityof 4.1TR (1640 cfm) to 5.0TR (2000 cfm) having EER as per BEEstandards and specifications with evaporator fan with motor, copper tubealuminium fin evaporator coil, washable air filter, insulated drain tray, in builtdrain pump, expansion device, cordless remote control with necessary controlsand electrical terminal to receive power supply, etc. having anti-corrosive coatingsuitable for coastal area and decorative slim dimension suitable for ceilingsuspended arrangement with an electronic control console and any additionalrefrigerant and oil charge as per requirement during installation complete. |
| 1076 | Supply, installation, testing and commissioning of VRV / VRF based ductabletype, high static room/indoor unit (IDU) having nominal cooling capacityof 5.1TR (2040 cfm) to 6.0TR 2400 cfm) having EER as per BEE standardsand specifications with evaporator fan with motor, copper tube aluminium finevaporator coil, washable air filter, insulated drain tray, in built drain pump,expansion device, cordless remote control with necessary controls and electricalterminal to receive power supply, etc. having anti-corrosive coating suitable forcoastal area and decorative slim dimension suitable for ceiling suspendedarrangement with an electronic control console and any additional refrigerant andoil charge as per requirement during installation complete. |
| 1077 | Supply, installation, testing and commissioning of VRV / VRF based ductabletype, high static room/indoor unit (IDU) having nominal cooling capacityof 8.0TR (3200 cfm) having EER as per BEE standards and specificationswith evaporator fan with motor, copper tube aluminium fin evaporator coil,washable air filter, insulated drain tray, in built drain pump, expansion device,cordless remote control with necessary controls and electrical terminal to receivepower supply, etc. having anti-corrosive coating suitable for coastal area anddecorative slim dimension suitable for ceiling suspended arrangement with anelectronic control console and any additional refrigerant and oil charge as perrequirement during installation complete. |
| 1078 | Supplying, laying/fixing, testing and commissioning of appropriate nominalrefrigerant copper pipe of 41.3mm dia (OD) for liquid line/suction line supplyand return piping of suitable gauge (hard copper pipe for liquid main line and softcopper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers withinsulation of 19mm thick elastomeric nitrile rubber along with application ofmulticoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultra violet radiations withOEM standards of VRV/VRF air conditioning system complete. |
| 1079 | Supplying, laying/fixing, testing and commissioning of appropriate nominalrefrigerant copper pipe of 34.9mm dia (OD) for liquid line/suction line supplyand return piping of suitable gauge (hard copper pipe for liquid main line and softcopper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers withinsulation of 19mm thick elastomeric nitrile rubber along with application ofmulticoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultra violet radiations withOEM standards of VRV/VRF air conditioning system complete |
| 1080 | supplying, laying/fixing, testing and commissioning of appropriate nominalrefrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supplyand return piping of suitable gauge (hard copper pipe for liquid main line and softcopper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers withinsulation of 19mm thick elastomeric nitrile rubber along with application ofmulticoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultra violet radiations withOEM standards of VRV/VRF air conditioning system complete. |
| 1081 | supplying, laying/fixing, testing and commissioning of appropriate nominalrefrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supplyand return piping of suitable gauge (hard copper pipe for liquid main line and softcopper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers withinsulation of 19mm thick elastomeric nitrile rubber along with application ofmulticoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultraviolet radiation with OEMstandards of VRV/VRF air conditioning system complete. |
| 1082 | supplying, laying/fixing, testing and commissioning of appropriate nominalrefrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supplyand return piping of suitable gauge (hard copper pipe for liquid main line and softcopper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers withinsulation of 19 mm thick elastomeric nitrile rubber along with application ofmulticoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultraviolet radiations withOEM standards of VRV/VRF air conditioning system complete. |
| 1083 | supplying, laying/fixing, testing and commissioning of appropriate nominalrefrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supplyand return piping of suitable gauge (hard copper pipe for liquid main line and softcopper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers withinsulation of 19mm thick elastomeric nitrile rubber along with application ofmulticoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultraviolet radiations withOEM standards of VRV/VRF air conditioning system complete. |
| 1084 | supplying, laying/fixing, testing and commissioning of appropriate nominalrefrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supplyand return piping of suitable gauge (hard copper pipe for liquid main line and softcopper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers withinsulation of 19mm thick elastomeric nitrile rubber along with application ofmulticoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultraviolet radiations withOEM standards of VRV/VRF air conditioning system complete. |
| 1085 | supplying, laying/fixing, testing and commissioning of appropriate nominalrefrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supplyand return piping of suitable gauge (hard copper pipe for liquid main line and softcopper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers withinsulation of 19mm thick elastomeric nitrile rubber along with application ofmulticoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultraviolet radiations withOEM standards of VRV/VRF air conditioning system complete. |
| 1086 | supplying, laying/fixing, testing and commissioning of appropriate nominalrefrigerant copper pipe of 6.4mm dia (OD) for liquid line/suction line supplyand return piping of suitable gauge (hard copper pipe for liquid main line and softcopper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers withinsulation of 19mm thick elastomeric nitrile rubber along with application ofmulticoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultraviolet radiations withOEM standards of VRV/VRF air conditioning system complete. |
| 1087 | Supplying and installation of high pressure grade required size copperconnection Y or T- Joints/refnet complete erected on wall/ceiling withsupports/raceways, Nitrile rubber insulation, painting etc. with brazing and testingfor leakages confirming the normal operation of the VRV/VRF air conditioningsystem. |
| 1088 | Supplying and erecting 25 mm dia., 2.45 mm min. thickness polyethylene composite pipe, conforming to IS 15450 :2004 duly joined by compression/crimp fitted accessories, with internal as well as external end sealing arrangement for Solar Water Heater System as per specification No. ESDHWP/PCP. |
| 1089 | Supplying and erecting 32 mm dia., 2.8 mm min. thickness polyethylenecomposite pipe, conforming to IS 15450 :2004 duly joined bycompression/crimp fitted accessories, with internal as well as external end sealingarrangement for Solar Water Heater System as per specification No. ESD HWP/PCP. |
| 1090 | Supplying and erecting 40 mm dia., 3.4 mm min. thickness polyethylenecomposite pipe, conforming to IS 15450 :2004 duly joined bycompression/crimp fitted accessories, with internal as well as external end sealingarrangement for Solar Water Heater System as per specification No. ESD HWP/PCP. |
| 1091 | Supplying, installing, testing and commissioning FR, XLPE armoured cable 4core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling completeas per specification no. CB-LT/CU |
| 1092 | upplying and erecting elastomeric nitrile rubber / foam tube type sleevesfor coating and insulating on provided PC / copper pipes having 9 mm thicknessand inner diameter / sizes 6 mm for solar water heater/AC system. |
| 1093 | Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275microns with galvanization process compliance to IS 2629:1985 to be usedfor fabrication of boxes panel boards etc. including cutting, bending, drilling,welding, riveting etc. and painting with one coat of red lead paint and 2 coats ofenamel paint. |
| 1094 | Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275microns with galvanization process compliance to IS 2629:1985 to be usedfor fabrication of boxes panel boards etc. including cutting, bending, drilling,welding, riveting etc. and painting with one coat of red lead paint and 2 coats ofenamel paint |
| 1095 | Supplying and erecting GI sheet 1 mm (20 SWG) having zinc coating of 275microns with galvanization process compliance to IS 2629:1985 to be usedfor fabrication of boxes panel boards etc. including cutting, bending, drilling,welding, riveting etc. and painting with one coat of red lead paint and 2 coats ofenamel paint. |
| 1096 | Supply, fabrication, installation and testing of flexible canvas connectionsconstructed between ductable unit/dampers/ducting of suitable size withfire resist flexible double canvas sleeve complete. |
| 1097 | Supplying and erecting aluminium powder coated linear grill of suitable sizefor width length without collar dampers having matching colour with theexisting false ceiling and suitable for deflection of 15/30/45°. |
| 1098 | Supply, installation, testing and commissioning of manually operated, opposedblade, duct mounted, flanged volume control dampers of required sizes inGI construction with operating mechanism, mounting arrangement, rubberrefrigerant kits etc. complete. |
| 1099 | Providing and applying of acoustic insulation for air ducts with 25mm thick,48 kg/cu.m fiber glass faced with RP tissue and covered with 26 SWGperforated aluminium sheets complete. |
| 1100 | Providing adhesive thermal insulation for supply return air duct with 19mmnitrile rubber insulation having R-value as per the prevailing provisions in ECBC 2017 |
| 1101 | Supplying, installing, testing and commissioning of AddressableMultisensor/Multicriteria (Smoke/IR + Heat + CO ) Detector. Thedetector shall have four sensing elements viz. Photo electric smoke, Heat, CarbonMonoxide & Infra Red Flame detection combined in a single detector. Thedetector shall have twin bi-colour LED for 360 deg viewing. Addressing shall bewith user friendly rotary decimal switches. The internal CO Sensor should bereplaceable upon EOL. It should be possible to generate 2 distinctive tones if theCO concentration reaches 2 definite user defined levels. This detectorconforming to EN 54/VdS / UL & FM approved with 3 years equipmentreplacement warranty, Designed to meet UL268, 7th Edition. |
| 1102 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipe as per specification no. CB-LT/CU |
| 1103 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipe as per specification no. CB-LT/CU |
| 1104 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipe as per specification no. CB-LT/CU |
| 1105 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ tru |
| 1106 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 1107 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 1108 | roviding & erecting hot dipped galvanised cover suitable for perforated typeCable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 400 mmwidth & 20 mm height complete with necessary hardware. |
| 1109 | Providing & erecting hot dipped galvanised cover suitable for perforated typeCable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mmwidth & 20 mm height complete with necessary hardware. |
| 1110 | roviding & erecting hot dipped galvanised cover suitable for perforated typeCable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mmwidth & 20 mm height complete with necessary hardware. |
| 1111 | Supply, installation, testing and commissioning of floor mounted / ceiling hung ductedTube/Vane axial Fan (Makeup Air) of double flanged construction with integral energy efficient IE2 motor with class F insulation complete with suitable thick hot dip galvanized casing of min. 220GSM zinc coating, cast aluminium rotor wheel (adjustable aero foil aluminium blades) of following capacity including all mounting accessories like hanger rods, Pre-wired terminal box mounted at fan casing, baseframes, mounting bracket, vibration isolators, inlet & outlet cones, fasteners, bolt nut etc. as per drawing and specification as complete as required. Fan efficiency shall not be less than 70% and noise level shall not be more than 75dBA @ 3m distance. Fan Air and sound performance shall be based on tests conducted in accordance AMCA standard 210 & 300 .14000 CFM @ 25 SP (Basement Exhaust Air) |
| 1112 | Supply, installation, testing and commissioning of floor mounted / ceiling hung ductedTube/Vane axial Fan (Makeup Air) of double flanged construction with integral energy efficient IE2 motor with class F insulation complete with suitable thick hot dip galvanized casing of min. 220GSM zinc coating, cast aluminium rotor wheel (adjustable aero foil aluminium blades) of following capacity including all mounting accessories like hanger rods, Pre-wired terminal box mounted at fan casing, baseframes, mounting bracket, vibration isolators, inlet & outlet cones, fasteners, bolt nut etc. as per drawing and specification as complete as required. Fan efficiency shall not be less than 70% and noise level shall not be more than 75dBA @ 3m distance. Fan Air and sound performance shall be based on tests conducted in accordance AMCA standard 210 & 300 .14000 CFM @ 25 SP (Basement Fresh Air) |
| 1113 | Supply, installation, testing and commissioning of PLC logic controller. 1) Basement car parking areas has been dived into multiple zones and PLC to be programmed to activate the JET fans of particular zone on getting signal from CO sensors of respective zones.2) PLC shall capable of accepting analog/digital signal from CO sensors and give digital output to dual speed jet fan starter based programmed logic as per CO level.3) On receipt of signal from fire alarm panel of particular zone PLC shall enable all jet fan, exhaust fan & makeup air fan as per the control methodology mentioned in drawing4) The panel shall incorporate \" timed solution\" that will allow 6ACPH normal mode & 6ACPH fire mode Exhaust fans to run alternatively with maintaining equal running hours during normal mode ventilation. During fire both fans runs. |
| 1114 | Supply, installation, testing and commissioning of Computational Fluid Dynamics (CFD) analysis for 3 number runs each for CO and smoke extraction for all zones. |
| 1115 | Supplying, installing, testing and commissioning of direct driven PROPELLER FANS for exhaust air as shown in drawings. Each fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate, accessories like wire guard, bird screen and fixed louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :CAPACITY-200 CFM (ToiletExhaust ) |
| 1116 | SITC of Inlinefans ( with necessory supports arrangement)complete with 1Ph Ph motor, frame for fixing, impeller, outlet cowl piece with protective wire mesh etc.Power cabling from this switch socket to fans shall be included in the unit rates.Capacities shall be as under.CAPACITY-1000 CFM(ToiletSupply )ESP-15mmwc |
| 1117 | SITC of Inlinefans ( with necessory supports arrangement)complete with 1Ph Ph motor, frame for fixing, impeller, outlet cowl piece with protective wire mesh etc.Power cabling from this switch socket to fans shall be included in the unit rates.Capacities shall be as under.CAPACITY-1100 CFM(ToiletSupply )ESP-15mmwc |
| 1118 | SITC of Inlinefans ( with necessory supports arrangement)complete with 1Ph Ph motor, frame for fixing, impeller, outlet cowl piece with protective wire mesh etc.Power cabling from this switch socket to fans shall be included in the unit rates.Capacities shall be as under.CAPACITY-1300 CFM(ToiletSupply )ESP-15mmwc |
| 1119 | SITC of Inlinefans ( with necessory supports arrangement)complete with 1Ph Ph motor, frame for fixing, impeller, outlet cowl piece with protective wire mesh etc.Power cabling from this switch socket to fans shall be included in the unit rates.Capacities shall be as under.CAPACITY-1300 CFM(ToiletExhaust )ESP-15mmwc |
| 1120 | SITC of Inlinefans ( with necessory supports arrangement)complete with 1Ph Ph motor, frame for fixing, impeller, outlet cowl piece with protective wire mesh etc.Power cabling from this switch socket to fans shall be included in the unit rates.Capacities shall be as under.CAPACITY-1600 CFM(ToiletExhaust )ESP-15mmwc |
| 1121 | SITC of ODU PANEL 1 The panel shall be comprising of following & IEC 61439, Panel should be fully compartmentallised, wall mounted withM.S. Channel dully painted, fabricated of 14swg CRCA sheets completely derusted, chemically treated and powder coated with approved shade, ON - Off Indicating LED lamp, locking arrangements, withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage, current, frequency, power factor , ON hrs, kWh and LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden, Surge protection device Imax 40 kA, type2, TPN. as per SLD having following items:-MainI/c 250 Amp FP MCCB. Bus bar chamber TPN & E withaluminium bars Outgoing-40A FP MCB -2 No. 50A TP MCCB- 6 Nos. |
| 1122 | Supplying, fixing, testing and balancingofextruded aluminium Supply Air grilles and Return Air grilles of powder coated as perapproved drawings complete as required confirming to specification. |
| 1123 | Supply ,installation, testing and commissioning ofJet impulse fans as per specifications for normal mode ventilation and Smoke Extraction. The fan & motor shall be suitable for 250 Deg C for 2 Hrs operations. Each fan shall be complete with dual speedmotor and adjustable pitch die cast aluminium impeller. Casing shall be made of Hot dipped Galvanized steel. The Motor shall be run on the electrical power suitable for 415V/3Ph/ 50Hz.Ancillaries to be included: The unit rate for each jet fan shall include the following ancillaries and no separate payment shall be made for the provision of ancillary items.Inlet & Outlet silencer, Inlet & outlet wire guard, Mounting bracket,outlet deflector, Motor holding arm, Unit mounted isolator switch.Jet Impulse fan -Thrust - 25N / 35N, 3-ph 1.5 / 0.37 Kw. (Fan size shall be subjected to CFD analysis) |
| 1124 | Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kVFor IDUs |
| 1125 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 1126 | Supplying and erecting single pole and neutral distribution board (SPNDB),with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, withdoor, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GIframe as per specification no. SW-SWR/MCBDB |
| 1127 | Supplying, erecting & commissioning 4 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 1128 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete asper specification no. SW-RCCB/RCCB |
| 1129 | Supplying, erecting & marking SP MCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 1130 | Supplying and erecting iron work, sheet metal work consisting of MS sheets, various sections ofcomplete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the site engineer. |
| 1131 | Supplying, installing and testing earthing with galvanised iron earth plate size 60 x 60 x 0.6 cm complete with all accessories of GI materials & recording the results as per specification No. EA-EP |
| 1132 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. |
| 1133 | Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system. |
| 1134 | Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system. |
| 1135 | Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR |
| 1136 | Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV(For Ring Main) |
| 1137 | Providing and making second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in foundation sand plinth of inner walls /in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. |
| 1138 | Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 1139 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 1140 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 1141 | Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 1142 | Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 1143 | Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 1144 | Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 1145 | Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 1146 | Supplying and erecting 200 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 1147 | Supplying and erecting 75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 1148 | Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 1149 | Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 1150 | Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, screen of SS end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 1151 | Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no.FF-FFA/ACT |
| 1152 | Supplying and erecting 20/25mm dia gun metal air release cock, withnecessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 1153 | Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc. as per requirement in an approved manner as per specification No. FF-FFA/PG |
| 1154 | Supplying and erecting12/15mm dia pressure switch with provide disolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 1155 | Supplying and erecting stainless steel double outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 1156 | Supplying and erecting one no. brass orifice plate having 6 mm. thickness, 160 mm outer dia and required/proper diameter of inner hole at every double outlet hydrant valve as per specification no. FF-FFA/OP |
| 1157 | Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m high pressure polypropylene (Polyhose) long fitted with necessary accessories complete as per specification No. FF-FFA/HV |
| 1158 | Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL |
| 1159 | Supplying and erecting 19 mm dia gun metal chrome plated nozzle complete as per specification no. FF-FFA/NZ |
| 1160 | Supplying & erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FF-FFA/NZ |
| 1161 | Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8\"x6\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 1162 | Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 1163 | Supplying and erecting 150mm diafire brigade header suitable for supplying water to wet riser system complete as per specification no. FF-FFA/FMC |
| 1164 | Supplying and erecting fire brigade header (Siamese connection) of 150 mm dia for supplying water in fire tank complete as per specification no. FF-FFA/FMC |
| 1165 | Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM Note: For estimating purpose consider 1 bag of 20kg to cover 300mm x 400mmarea 150mm thick or 0.018 m3 |
| 1166 | Providing round bottom FIRE Bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook. |
| 1167 | Providing floor mounting Stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint. |
| 1168 | Supplying and erecting ABC powder type fire extinguisher as perIS : 13849/15683 of 6 kg capacity with necessary clamp for erection on wall. |
| 1169 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete |
| 1170 | Supplying and erecting G.I. pipe ‘C’ class ERW 20 mm dia with necessary fittings complete as per specification no. FF-PP |
| 1171 | Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittingscomplete as per specification no. FF-PP |
| 1172 | Supplying and erecting G.I. pipe ‘C’ class ERW 32 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 1173 | Supplying and erecting G.I. pipe ‘C’ class ERW 40 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 1174 | Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittingscomplete as per specification no. FF-PP |
| 1175 | Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP |
| 1176 | Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP |
| 1177 | Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittingscomplete as per specification no. FF-PP |
| 1178 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittingscomplete as per specification no. FF-PP |
| 1179 | Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 1180 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 1181 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 1182 | Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 1183 | Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 1184 | Supplying, erecting, testing and commissioning vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 100 mm dia having following features 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4) Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes |
| 1185 | Supplying, erecting, testing and commissioning of pendent bulb sprinkler, 15 mm (½\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FFSPR. |
| 1186 | Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears: 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU\"s, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. (Addon 1 Working+ 1 Standby+ 1 Diesel pump) |
| 1187 | Main Fire & Sprinkler PumpSupplying, installation, testing and commissioning of main fire pump (MFP /EP) suitable for water discharge of 2280 to 2850LPM at 80 to 60 m headdriven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 45kW or of suitable kW capacity for manual/automatic operation and consisting of following:(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP |
| 1188 | Jocky PumpSupplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP |
| 1189 | Booster PumpSupplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP |
| 1190 | Diesel PumpSupplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation boltsetc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP |
| 1191 | Supplying, installation,testing and commissioning of micro processor based intelligent addressable main firealarm panel,central processing unit with the 4 loop capacity and capableofsupportingupto250 devices and detectors per loop,withon-board LCD display with min 16 lines of text, operating at 230V 50HZ-AC with in built Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS2189: 2008, EN54&VDS/FM/UL864 (10th edition) with 3 years replacement warranty FF AFAS/CP |
| 1192 | Supplying, installing, testing and commissioning of addressable optical smoke detector,single / twin LED’s with 360 degree view, suitable for lowvoltage15 to 32 VDC two wires supply, in-built locking mechanism to check the removal ampilfe rage of the detector, inbuilt isolation mode,startup current 300μA and alarm condition current shalL be maximum 6.5mA,operating temperature 0°Cto 50°C, humidity 0-95%RH, IP41, conforming to IS2189: 2008,11360_1985_Reff2020EN54 or UL Approved with 3 years equipment replacement warranty FFAFAS/SD . |
| 1193 | Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with\"BreakGlass\" massage embedded on the glass, complete erected |
| 1194 | Supplying, installing, testing and commissioning FRLS armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU. Note For item no.13-9-10 to 13-9-13 increase rate by 2% for FRLS |
| 1195 | Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000Hz with dB asper Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’sentire operating voltage range EN54, conforming to IS2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. |
| 1196 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V,2core 2.5sq.mm.copper conductor complete erected with glands & lugs, on wall /trusses / pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 1197 | Supplying, erecting, testing and commissioning 15 to 30 Watts soundcolumn or ceiling mounted complete as per specification no. FF-PA/SOC |
| 1198 | Supplying, erecting, testing and commissioning 120W amplifier suitable to operate on 230 Volts A.C. / 12Volts D.C. supply complete as per specification no. FF-PA/AFR |
| 1199 | Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50-16000 Hz suitable to operate in-10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF PA/MIC |
| 1200 | Supplying, erecting, testing and commissioning rust free microphone floor stand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete.. (Similar to AHUJA make model DGT) |
| 1201 | Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF PA/MCC |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy