| 1 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer- in-charge. |
| 2 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 4 | All kinds of soil |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level: |
| 7 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, if nishing and reinforcement- All work up to plinth level : |
| 9 | 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived fromnatural sources: 3 graded stone aggregate 20 mm nominalsize derived from natural sources). |
| 10 | Providing and laying Hollow cement concrete block walling 200mm thick consisting of hollow block of size 400x200x200mm of mix 1:3:6 (1cement:3 Pulverised sand:6 graded stone aggregates of 10mm nominal size) laid in cement martar 1:6 (1cement :6 sand). |
| 11 | Reinforced cement concrete work in walls (any thickness), including attachedpilasters,buttresses,plinthandstring courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement |
| 12 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominalsize derived from natural sources). |
| 13 | Reinforcedcementconcreteworkinbeams,suspended floors,roofshaving slopeup to 15°landings,balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement,with 1:1.5:3 (1cement: 1.5coarsesand (zone-III)derivedfromnaturalsources: 3gradedstone aggregate 20mm nominalsize derivedfrom natural sources). |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 15 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 17 | Foundations, footings, bases of columns, etc. for mass concrete |
| 18 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 19 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 20 | Suspended floors, roofs, landings, balconies and access platform |
| 21 | 12 mm cement plaster of mix : |
| 22 | 1:4 (1 cement: 4 River sand) |
| 23 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 24 | Electric resistance or induction butt welded tubes |
| 25 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 26 | Providing and fixing bolts including nuts and washers complete. |
| 27 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 28 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 29 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 30 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 31 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 32 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : |
| 33 | Two or more coats on new work |
| 34 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. |
| 35 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 36 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 37 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 38 | Semi rigid pipe |
| 39 | 40 mm dia |
| 40 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
| 41 | 25 mm nominal outer dia Pipes |
| 42 | 20 mm nominal outer dia Pipes |
| 43 | 15 mm nominal outer dia Pipes |
| 44 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. |
| 45 | 20 mm nominal bore, 120 mm long, weighing not less than 198 gms |
| 46 | 25 mm nominal bore, 152mm long, weighing not less than 440 gms |
| 47 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 48 | 15 mm nominal bore, 165 mm long, weighing not less than 110 gms |
| 49 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 50 | 40 mm thick with 20 mm nominal size stone aggregate |
| 51 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 52 | 80x1.20 mm M.S. laths with 1.20 mm thick top cover |
| 53 | ELECTRICAL WORKS |
| 54 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with piano type switch, suitable size PVC box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 55 | Group C |
| 56 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC Conduit, alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 57 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required. |
| 58 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 59 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 60 | Supplying and fixing PVC boxon surface or in recess, including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). |
| 61 | Supplying and fixing PVC boxon surface or in recess, including providing and fixing 6 pin 15/16amps socket outlet and 15/16 amps Piano type switch, connection, painting etc. as required. |
| 62 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ PVC block including connection etc as required. |
| 63 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 64 | 4 way, Single Door |
| 65 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 66 | Single Pole |
| 67 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 68 | 40 Amps, 2 Pole Isolator |
| 69 | Supplying of A.C. Ceiling fan and regulator (1200mm sweep) with all accessories as required (Make: Bajaj/Usha/Orient/Crompton or equivalent to ISI standard). |
| 70 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 71 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 72 | Supplying of ENDURA RUGBY energy saving new generation bulkhead luminaire with opal diffuser 10W LED 6000K similar to Havells Cat No. LHEOAOP7UZ6W010 or its equivalent to ISI standard. |
| 73 | Supplying and fixing of new generation energy saving enviroment friendly long life 25 W LED street light made up of pressure dia cast aluminium housing with high power LED as light source and embeded PC cover having top opening seprate driver compertment with IP65 PROTECTION AND ik07 IMPACET RESISTENCE (MAKE : Polycab CAT No.PUBO506109 ) along with its Mountning (GI PIPE 32mm) (Make: Bajaj /Havells /Orient/Crompton or equivalent to ISI standard). |
| 74 | Supplying of prewired LED tube light 20W LUMEN output 2000lm 6500K Product code PANASONIC PBTM02203 or equivalent to ISI standard. (Havells/Panasonic/Polycab) or Equivalent to ISI Standarad. |
| 75 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 76 | Supplying and Installation of Exhaust fan (300 mm sweep, 900 rpm) Single phase with all accessories etc as required. Similar to Havells, Bajaj or equivalent to ISI Standard. |
| 77 | Supplying and fixing rewirable porceline with fuse unit of 32 to 40 amps on energy meter board. |
| 78 | Providing and fixing of Syntex box of size 310mm x 285mm x 180 mm for fixing of Energymeter etc. as required. |