| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-05-2025 | 2nd date extension | Date | 13-05-2025 |
| 2 | 24-04-2025 | 1st date extension | Date | 01-05-2025 |
| Sl. No. | Item Description |
| 1 | 220 KV S/S Dhar, 3006279, 14.1.1, Repairs to plaster of thickness 12mm to 20mm in patches of area2.5sq.metres……...With cement mortar 1:4 (1 cement : 4 sand). |
| 2 | 3004996, 6.6.2, Brickworkwithwellbruntopen bhatta,bricks,crushing strengthnot less …. etc complete.Cement Mortar 1:6 (1 cement : 6 sand) |
| 3 | 3004838, 4.1.2.3, Providing and laying in position cement concrete of …. M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate |
| 4 | 3004929, 5.16.6, Reinforcement for R.C.C. work including straightening, cutting, bending, placing.....etc. complete . Thermo-Mechanically Treated bars. (TMT/TMX)FE500.separately as shown in the drawing and as per ....Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786 |
| 5 | 3004884, 5.1.1, Providing and laying in position specified grade of reinforced cement concrete (with 20mm ...reinforcement- All work up to plinth level : M-20 Grade Concrete |
| 6 | 3006325, 14.30, Removingdryoroilbound distemper, water proofing ….. repairs to scratches etc. complete. |
| 7 | 3006206, 13.41, Providing and applying white cement based putty of average thickness……. of APD/Chief Engineer will be required. |
| 8 | 3006924, 18.6.2.2, Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply …Charge...Concealed work including cutting chases and making good the walls etc...20 mm nominal outer dia .Pipes. |
| 9 | 3006929, 18.7.3, Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,……..testing of joints complete as per direction of Engineer-in- Charge. External Work.25 mm nominal outer dia .Pipes. |
| 10 | 3007138, 18.14.3, Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore |
| 11 | 3007218, 18.34, Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore. |
| 12 | 3007665, 25.45, Providing and fixing in position best Indian Auto Closing 32mm, Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/cartridge). (Premium Range) |
| 13 | 3006809, 17.61, Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet |
| 14 | 3006644, 17.17.2, Providing and fixing white vitreous china water closet squatting pan (Indian type)..Orissa pattern W.C. pan of size 580x440 mm |
| 15 | 3006805, 17.59.5.1, Providing and fixing unplasticised PVC moulded fittings/ …..expansion..Bend 87.50..75 mm bend |
| 16 | 3004746, 2.6.1, Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas…….and neatly dressed.All kinds of soil |
| 17 | 3007292, 19.4.2, Providing and laying below…..paid seperataly...160 mm diameter OD (min. wall thickness 4.0mm) |
| 18 | 3007291, 19.4.1, Providing and laying below groundunplasticisedPVCpipe to withstandworkingpressure of4kg/cm2soildwaste pipes confirming toIS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving10mmgapfor thermal expansionallnecessaryfittings etc. complete. Excavation to be paid seperataly...110 mm diameter OD (min. wall thickness 3.2mm) |
| 19 | 3007297, 19.5.2, Providing and laying cement concrete 1:3:6 (1 cement: 3 sand:6gradedstoneaggregate 20mmnominalsize) all-round PVC. pipes including bed concrete as per standard design:..160 mm diameter PVC. pipe |
| 20 | 3007296,19.5.1,Providing and laying cement concrete 1:3:6…. bed concrete as per standard design:..110 mm diameter PVC. pipe |
| 21 | 3006033, 12.32.2, Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water... expansion. 110 mm diameter (minimum wall thickness 2.2mm) |
| 22 | 3007366, 19.27.1, \"Constructing brick masonry manholeincementmortar1:4 ( 1 cement : 4 sand ) R.C.C. top slabwith....completeas per standard design :Inside size 90x80 cm and 45 cm deep includingC.I. coverwith frame (light duty) 455x610 mm internal dimensions total weight ofcoverandframetobenot less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :..With well burnt bricks\" |
| 23 | 3006637, 17.14.2.1, Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I...required :..Kitchen sink without drain board..610x510 mm bowl depth 200 mm. |
| 24 | 3005828, 11.22.5, Providingandfixing18mmthickgangsawcut mirror polished(premoulded and prepolished) machinecutfor kitchen platforms,vanity counters, window sills , facias and similar locations of required size of approved shade, colourandtexturelaidover20mmthickbase cement mortar 1:4 (1 cement : 4 sand) with joints treated withwhitecement,mixed withmatching pigment, epoxy touch ups, including rubbing, curingmouldingand polishingtoedgetogive high gloss finish wherever required etc. complete atalllevels.Samplesapproved by Engineer-in- Charge. Cuddpah stone |
| 25 | 3005862, 11.41, Extraforprovidingopeningofrequiredsizeand shapefor washbasins/kitchensinkinkitchen platform,vanity counters andsimilarlocationin marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 26 | 3005877, 11.51, ProvidingandlayingrectifiedGlazedCeramic walltiles 300x450mmormore(thicknesstobe specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 12mmthickcementmortar1:3(1Cement:3 sand) includinggroutingthejointswithwhite cement and matching pigments etc., complete. |
| 27 | 3005876, 11.50, ProvidingandlayingrectifiedGlazedCeramic floor tiles 300x300 mm or more (having thickness9to10mm)of1st qualityconformingtoIS: 15622ofapprovedmakeinallcolourswhite, ivory, grey,fume redbrown laid on20mm thick cement mortar 1:4 (1 Cement : 4 sand) including grouting the joints with white cement and matching pigments etc., complete. |
| 28 | 3006816, 17.64.1.1, Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete..Semi rigid pipe..32 mm dia |
| 29 | 3006211, 13.46, Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work |
| 30 | 3006240, 13.64, Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 31 | 3006285, 14.5.1, Renewing glass panes, with putty andnailswherevernecessary including racking out the old putty:Float glass panes of thickness 4 mm |
| 32 | 3007215, 18.31, Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, 15 mm nominal bore. |
| 33 | 3007216, 18.32, Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore. |
| 34 | 3006357, 14.52.1, Finishing walls with Premium Acrylic Smooth exterior paint withSiliconeadditivesof required shade..Oldwork (Twoormorecoats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. |
| 35 | 3007228, 18.43.2, Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :..150 mm diameter |
| 36 | 3005212, 9.18.2, Providing and fixing ISI marked flush door shutters......shutter. 30mmthickincludingISImarked Stainless Steel butt hinges with necessary screws. |
| 37 | 3005916, 11.76.1, Providing and laying vitrified floor tiles (without solublesalt)orprinted(withsolublesalt)Nano polished(Glossy finish)in different ….matching pigments etc. complete Plain ivory light shade Size 600X600mm thickness 9-10mm |
| 38 | 3005918, 11.77.1, Providing and laying vitrified floor tiles (without solublesalt)orprinted(withsolublesalt)Nano polished(Glossy finish)in different.....skirting laid on 12mm thick cement mortar 1:4(1cement :4sand) ... complete Plain ivory light shade Size 600X600mm thickness 9-10mm |
| 39 | 3005665, 10.2, StructuralsteelworkusingM.S.flats, angles,channels I-section,H-sectionetc. riveted, bolted or welded in built up sections,trussesandframedwork, including cutting,hoisting,fixingin positionand applyinga primingcoatof approved steel primer all complete. |
| 40 | 3005535, 9.166.1, Providing and fixing factory made 30 mm thick PVC door shutter consisting of frame made..direction of Engineer-in-charge. Manufacturer’s specification and drawing. Plain PVC door shutters. |
| 41 | 3007210, 18.28, Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 …...outlet and overflow pipes but without fittings and the base support for tank |
| 42 | 3008184, 5.1.1.1, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary short point. (Using modular accessories) |
| 43 | 3008185, 5.1.1.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary medium point. (Using modular accessories) |
| 44 | 3008186, 5.1.1.3, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary long point. (Using modular accessories) |
| 45 | 3008191, 5.1.3.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- 3 Pin 6 Amp socket outlet on separate board Medium point. (Using modular accessories) |
| 46 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Call bell/buzzer points Medium point. (Using modular accessories) |
| 47 | 3008199, 5.2 Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside casing & capping with required materials as per specification on same board. .(Using modular accessories) |
| 48 | 3008180, 5.3.1, Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping of ISI marked suitable size etc. as required as per specification 2x2.5 Sq.mm ( Using flush type normal accessories) |
| 49 | 3008274, 10.1.1.2, Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :- On separate board Medium point. (Using modular accessories) |
| 50 | 3008275, 10.1.1.3, Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :- On separate board Long point. (Using modular accessories) |
| 51 | 3009107, 27.8.1.2, Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of \"C\" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single pole MCB SP 6Amp to 32Amp 10kA rating |
| 52 | 3009249, 27.23.1.1, Supply & fixing of approved make accepted standard sheet steel enclosure (dust protected) duly powder coated paint neutral bar suitable for MCB/RCBOs/MCCB of capacity as required etc. complete as per specification (exclusive of M.C.B./ MCCB/RCBOs) For MCB SP enclosure |
| 53 | 3009366, 29.25.2, Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board 100 Watt (2 module) |
| 54 | 3008368, 18.3.1, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-1 Or 2 Module PVC box |
| 55 | 3008370, 18.3.3, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-4 Module PVC box |
| 56 | 3008371, 18.3.4, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-6 Module PVC box |
| 57 | 3007524 ,22.14.1,Grading roof for receiving water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) |
| 58 | 3006376 ,14.65,Providing & casting & Repairing of excessively damaged memberswith micro-concrete at all levels with all leads & lift or as directed including formwork, centering, scaffolding, and mixing, laying, levelling, and finishing including curing etc. complete (excluding steel reinforcement |
| 59 | 3006415 ,14.80.1,Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: easurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2)-12 mm average thickness |
| 60 | 3007534 ,22.22,Water proofing treatment over Roof, Wall, Chajjas,, Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of(i) Surface preparation roughening of surface, opening cracks in ‘V’ groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely.(ii) Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80%-chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2ndcoat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow thecoating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per anufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). (iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hight build elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs. minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air cure for 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area.(iv) The treated area should be cure with water for 48 hrs. by flooding the surface.(v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee) |
| 61 | 3007542 ,22.3,Providing & applying crack fill paste for crack filling up to 5 mm cracks.Widen the crack by putty knife in V/U shape & apply 1st priming coat of crack fill paste diluted with water in 1:1 proportion over the crack by brush. |
| 62 | 220 KV S/S Depalpur3006279, 14.1.1, Repairs to plaster of thickness 12mm to 20mm in patches of area2.5sq.metres……...With cement mortar 1:4 (1 cement : 4 sand). |
| 63 | 3004996, 6.6.2, Brickworkwithwellbruntopen bhatta,bricks,crushing strengthnot less …. etc complete.Cement Mortar 1:6 (1 cement : 6 sand) |
| 64 | 3004838, 4.1.2.3, Providing and laying in position cement concrete of …. M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate |
| 65 | 3004929, 5.16.6, Reinforcement for R.C.C. work including straightening, cutting, bending, placing.....etc. complete . Thermo-Mechanically Treated bars. (TMT/TMX)FE500.separately as shown in the drawing and as per ....Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786 |
| 66 | 3004884, 5.1.1, Providing and laying in position specified grade of reinforced cement concrete (with 20mm ...reinforcement- All work up to plinth level : M-20 Grade Concrete |
| 67 | 3006325, 14.30, Removingdryoroilbound distemper, water proofing ….. repairs to scratches etc. complete. |
| 68 | 3006206, 13.41, Providing and applying white cement based putty of average thickness……. of APD/Chief Engineer will be required. |
| 69 | 3006924, 18.6.2.2, Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply …Charge...Concealed work including cutting chases and making good the walls etc...20 mm nominal outer dia .Pipes. |
| 70 | 3006929, 18.7.3, Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,……..testing of joints complete as per direction of Engineer-in- Charge. External Work.25 mm nominal outer dia .Pipes. |
| 71 | 3007138, 18.14.3, Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore |
| 72 | 3007218, 18.34, Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore. |
| 73 | 3007665, 25.45, Providing and fixing in position best Indian Auto Closing 32mm, Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/cartridge). (Premium Range) |
| 74 | 3006809, 17.61, Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet |
| 75 | 3006644, 17.17.2, Providing and fixing white vitreous china water closet squatting pan (Indian type)..Orissa pattern W.C. pan of size 580x440 mm |
| 76 | 3006805, 17.59.5.1, Providing and fixing unplasticised PVC moulded fittings/ …..expansion..Bend 87.50..75 mm bend |
| 77 | 3004746, 2.6.1, Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas…….and neatly dressed.All kinds of soil |
| 78 | 3007292, 19.4.2, Providing and laying below…..paid seperataly...160 mm diameter OD (min. wall thickness 4.0mm) |
| 79 | 3007291, 19.4.1, Providing and laying below groundunplasticisedPVCpipe to withstandworkingpressure of4kg/cm2soildwaste pipes confirming toIS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving10mmgapfor thermal expansionallnecessaryfittings etc. complete. Excavation to be paid seperataly...110 mm diameter OD (min. wall thickness 3.2mm) |
| 80 | 3007297, 19.5.2, Providing and laying cement concrete 1:3:6 (1 cement: 3 sand:6gradedstoneaggregate 20mmnominalsize) all-round PVC. pipes including bed concrete as per standard design:..160 mm diameter PVC. pipe |
| 81 | 3007296, 19.5.1, Providing and laying cement concrete 1:3:6…. bed concrete as per standard design:..110 mm diameter PVC. pipe |
| 82 | 3006033, 12.32.2, Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water... expansion. 110 mm diameter (minimum wall thickness 2.2mm) |
| 83 | 3007366, 19.27.1, \"Constructing brick masonry manholeincementmortar1:4 ( 1 cement : 4 sand ) R.C.C. top slabwith....completeas per standard design :Inside size 90x80 cm and 45 cm deep includingC.I. coverwith frame (light duty) 455x610 mm internal dimensions total weight ofcoverandframetobenot less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :..With well burnt bricks\" |
| 84 | 3006637, 17.14.2.1, Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required :..Kitchen sink without drain board..610x510 mm bowl depth 200 mm. |
| 85 | 3005828, 11.22.5, Providingandfixing18mmthickgangsawcut mirror polished(premoulded and prepolished) machinecutfor kitchen platforms,vanity counters, window sills , facias and similar locations of required size of approved shade, colourandtexturelaidover20mmthickbase cement mortar 1:4 (1 cement : 4 sand) with joints treated withwhitecement,mixed withmatching pigment, epoxy touch ups, including rubbing, curingmouldingand polishingtoedgetogive high gloss finish wherever required etc. complete atalllevels.Samplesapproved by Engineer-in- Charge. Cuddpah stone |
| 86 | 3005862, 11.41, Extraforprovidingopeningofrequiredsizeand shapefor washbasins/kitchensinkinkitchen platform,vanity counters andsimilarlocationin marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 87 | 3005877, 11.51, ProvidingandlayingrectifiedGlazedCeramic walltiles 300x450mmormore(thicknesstobe specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 12mmthickcementmortar1:3(1Cement:3 sand) includinggroutingthejointswithwhite cement and matching pigments etc., complete. |
| 88 | 3005876, 11.50, ProvidingandlayingrectifiedGlazedCeramic floor tiles 300x300 mm or more (having thickness9to10mm)of1st qualityconformingtoIS: 15622ofapprovedmakeinallcolourswhite, ivory, grey,fume redbrown laid on20mm thick cement mortar 1:4 (1 Cement : 4 sand) including grouting the joints with white cement and matching pigments etc., complete. |
| 89 | 3006816, 17.64.1.1, Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete..Semi rigid pipe..32 mm dia |
| 90 | 3006211,13.46, Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work |
| 91 | 3006240, 13.64, Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 92 | 3006285, 14.5.1, Renewing glass panes, with putty andnailswherevernecessary including racking out the old putty:Float glass panes of thickness 4 mm |
| 93 | 3007215, 18.31, Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, 15 mm nominal bore. |
| 94 | 3007216, 18.32, Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore. |
| 95 | 3006357, 14.52.1, Finishing walls with Premium Acrylic Smooth exterior paint withSiliconeadditivesof required shade..Oldwork (Twoormorecoats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. |
| 96 | 3007228,18.43.2,Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :..150 mm diameter |
| 97 | 3005212, 9.18.2, Providing and fixing ISI marked flush door shutters......shutter. 30mmthickincludingISImarked Stainless Steel butt hinges with necessary screws. |
| 98 | 3005916, 11.76.1, Providing and laying vitrified floor tiles (without solublesalt)orprinted(withsolublesalt)Nano polished(Glossy finish)in different ….matching pigments etc. complete Plain ivory light shade Size 600X600mm thickness 9-10mm |
| 99 | 3005918, 11.77.1, Providing and laying vitrified floor tiles (without solublesalt)orprinted(withsolublesalt)Nano polished(Glossy finish)in different.....skirting laid on 12mm thick cement mortar 1:4(1cement :4sand) ... complete Plain ivory light shade Size 600X600mm thickness 9-10mm |
| 100 | 3005665, 10.2, StructuralsteelworkusingM.S.flats, angles,channels I-section,H-sectionetc. riveted, bolted or welded in built up sections,trussesandframedwork, including cutting,hoisting,fixingin positionand applyinga primingcoatof approved steel primer all complete. |
| 101 | 3005535, 9.166.1, Providing and fixing factory made 30 mm thick PVC door shutter consisting of frame made..direction of Engineer-in-charge. Manufacturer’s specification and drawing. Plain PVC door shutters. |
| 102 | 3007210, 18.28, Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 …...outlet and overflow pipes but without fittings and the base support for tank |
| 103 | 3008184, 5.1.1.1, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary short point. (Using modular accessories) |
| 104 | 3008185, 5.1.1.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary medium point. (Using modular accessories) |
| 105 | 3008186, 5.1.1.3, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary long point. (Using modular accessories) |
| 106 | 3008191, 5.1.3.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- 3 Pin 6 Amp socket outlet on separate board Medium point. (Using modular accessories) |
| 107 | 3008194, 5.1.4.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Call bell/buzzer points Medium point. (Using modular accessories) |
| 108 | 3008199, 5.2 Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside casing & capping with required materials as per specification on same board. .(Using modular accessories) |
| 109 | 3008180, 5.3.1, Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping of ISI marked suitable size etc. as required as per specification 2x2.5 Sq.mm ( Using flush type normal accessories) |
| 110 | 3008274, 10.1.1.2, Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :- On separate board Medium point. (Using modular accessories) |
| 111 | 3008275, 10.1.1.3, Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :- On separate board Long point. (Using modular accessories) |
| 112 | 3009107, 27.8.1.2, Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of \"C\" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single pole MCB SP 6Amp to 32Amp 10kA rating |
| 113 | 3009249, 27.23.1.1, Supply & fixing of approved make accepted standard sheet steel enclosure (dust protected) duly powder coated paint neutral bar suitable for MCB/RCBOs/MCCB of capacity as required etc. complete as per specification (exclusive of M.C.B./ MCCB/RCBOs) For MCB SP enclosure |
| 114 | 3009366, 29.25.2, Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board 100 Watt (2 module) |
| 115 | 3008368, 18.3.1, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-1 Or 2 Module PVC box |
| 116 | 3008370,18.3.3, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-4 Module PVC box |
| 117 | 3008371, 18.3.4, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-6 Module PVC box |
| 118 | 3007524 ,22.14.1,Grading roof for receiving water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) |
| 119 | 3006376 ,14.65,Providing & casting & Repairing of excessively damaged memberswith micro-concrete at all levels with all leads & lift or as directed including formwork, centering, scaffolding, and mixing, laying, levelling, and finishing including curing etc. complete (excluding steel reinforcement |
| 120 | 3006415 ,14.80.1,Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: easurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2)-12 mm average thickness |
| 121 | 3007534 ,22.22,Water proofing treatment over Roof, Wall, Chajjas,, Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of(i) Surface preparation roughening of surface, opening cracks in ‘V’ groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely.(ii) Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80%-chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2ndcoat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow thecoating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per anufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). (iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hight build elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs. minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air cure for 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area.(iv) The treated area should be cure with water for 48 hrs. by flooding the surface.(v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee) |
| 122 | 3007542 ,22.3,Providing & applying crack fill paste for crack filling up to 5 mm cracks.Widen the crack by putty knife in V/U shape & apply 1st priming coat of crack fill paste diluted with water in 1:1 proportion over the crack by brush. |
| 123 | Pithampur Sec- I, 3006279, 14.1.1 .Repairs to plaster of thickness 12mm to 20mm in patches of area2.5sq.metresand….. dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4 sand). |
| 124 | 3004994, 6.5.2, Brickworkwithwellbruntopen bhatta,bricks,crushing strengthnot less than 25kg /cm2 and water absorptionnot morethan20%in foundationandplinthi/ccuringetc complete. Cement Mortar 1:6 (1 cement: 6 sand). |
| 125 | 3006149, 13.3.2, 20 mm cement plaster of mix : 1:6 (1 cement : 6 sand) |
| 126 | 3004838, 4.1.2.3, Providing and laying in position cement concrete of …. M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate |
| 127 | 3004929, 5.16.6, Reinforcement for R.C.C. work including straightening, cutting, bending, placing.....etc. complete . Thermo-Mechanically Treated bars. (TMT/TMX)FE500.separately as shown in the drawing and as per ....Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786 |
| 128 | 3004884, 5.1.1, Providing and laying in position specified grade of reinforced cement concrete (with 20mm ...reinforcement- All work up to plinth level : M-20 Grade Concrete |
| 129 | 3004893, 5.9.1, Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level |
| 130 | 3006325, 14.30,Removingdryoroilbound distemper, water proofing ….. repairs to scratches etc. complete. |
| 131 | 3006206, 13.41, Providing and applying white cement based putty of average thickness……. of APD/Chief Engineer will be required. |
| 132 | 3006924, 18.6.2.2, Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply …Charge...Concealed work including cutting chases and making good the walls etc...20 mm nominal outer dia .Pipes. |
| 133 | 3006929, 18.7.3, Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,..having thermal stability for hot and cold water supply including all CPVC……. of Engineer-in- Charge. External Work.25 mm nominal outer dia .Pipes. |
| 134 | 3007138, 18.14.3,Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore |
| 135 | 3007218, 18.34, Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore. |
| 136 | 3007665, 25.45, Providing and fixing in position best Indian Auto Closing 32mm, Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/cartridge). (Premium Range) |
| 137 | 3006809, 17.61, Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet |
| 138 | 3006644, 17.17.2, Providing and fixing white vitreous china water closet squatting pan (Indian type)..Orissa pattern W.C. pan of size 580x440 mm |
| 139 | 3006805, 17.59.5.1, Providing and fixing unplasticised PVC moulded fittings/ …..expansion..Bend 87.50..75 mm bend |
| 140 | 3006040, 12.33.3.2, Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for ….. Single tee with door 110x110x110 mm (minimum wall thickness 2.2mm) |
| 141 | 3006806,17.59.5.2, Providing and fixing unplasticised PVC moulded fittings/ …..expansion..Bend 87.50....110 mm bend |
| 142 | 3004746, 2.6.1, Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas…….and neatly dressed.All kinds of soil |
| 143 | 3007292,19.4.2,Providing and laying below…..paid seperataly...160 mm diameter OD (min. wall thickness 4.0mm) |
| 144 | 3007291, 19.4.1, Providing and laying below groundunplasticisedPVCpipe to withstandworkingpressure of4kg/cm2soildwaste pipes confirming toIS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving10mmgapfor thermal expansionallnecessaryfittings etc. complete. Excavation to be paid seperataly...110 mm diameter OD (min. wall thickness 3.2mm) |
| 145 | 3007297, 19.5.2, Providing and laying cement concrete 1:3:6 (1 cement: 3 sand:6gradedstoneaggregate 20mmnominalsize) all-round PVC. pipes including bed concrete as per standard design:..160 mm diameter PVC. pipe |
| 146 | 3007296, 19.5.1, Providing and laying cement concrete 1:3:6 (1 cement: 3 sand:6gradedstoneaggregate 20mmnominalsize) all-round PVC. pipes including bed concrete as per standard design:..110 mm diameter PVC. pipe |
| 147 | 3006033, 12.32.2, Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm diameter (minimum wall thickness 2.2mm) |
| 148 | 3007366, 19.27.1, \"Constructing brick masonry manholeincementmortar1:4 ( 1 cement : 4 sand ) R.C.C. top slabwith....completeas per standard design :Inside size 90x80 cm and 45 cm deep includingC.I. coverwith frame (light duty) 455x610 mm internal dimensions total weight ofcoverandframetobenot less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :..With well burnt bricks\" |
| 149 | 3006637, 17.14.2.1, Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as …..required :..Kitchen sink without drain board..610x510 mm bowl depth 200 mm. |
| 150 | 3005828, 11.22.5 Providingandfixing18mmthickgangsawcut mirror polished(premoulded and prepolished) machinecutfor kitchen platforms,vanity counters, window sills , facias and similar locations of required size of approved shade, colourandtexturelaidover20mmthickbase cement mortar 1:4 (1 cement : 4 sand) with joints treated withwhitecement,mixed withmatching pigment, epoxy touch ups, including rubbing, curingmouldingand polishingtoedgetogive high gloss finish wherever required etc. complete atalllevels.Samplesapproved by Engineer-in- Charge. Cuddpah stone |
| 151 | 3005862, 11.41, Extraforprovidingopeningofrequiredsizeand shapefor washbasins/kitchensinkinkitchen platform,vanity counters andsimilarlocationin marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 152 | 3005877, 11.51,ProvidingandlayingrectifiedGlazedCeramic walltiles 300x450mmormore(thicknesstobe specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 12mmthickcementmortar1:3(1Cement:3 sand) includinggroutingthejointswithwhite cement and matching pigments etc., complete. |
| 153 | 3005876, 11.50, ProvidingandlayingrectifiedGlazedCeramic floor tiles 300x300 mm or more (having thickness9to10mm)of1st qualityconformingtoIS: 15622ofapprovedmakeinallcolourswhite, ivory, grey,fume redbrown laid on20mm thick cement mortar 1:4 (1 Cement : 4 sand) including grouting the joints with white cement and matching pigments etc., complete. |
| 154 | 3006816, 17.64.1.1,Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete..Semi rigid pipe..32 mm dia |
| 155 | 3006211, 13.46, Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work |
| 156 | 3006240, 13.64, Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 157 | 3007215, 18.31, Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, 15 mm nominal bore. |
| 158 | 3007216, 18.32, Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore. |
| 159 | 3006357, 14.52.1, Finishing walls with Premium Acrylic Smooth exterior paint withSiliconeadditivesof required shade..Oldwork (Twoormorecoats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. |
| 160 | 3007228, 18.43.2, Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :..150 mm diameter |
| 161 | 3006622, 17.11.4, Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. …..:White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 162 | 3005212, 9.18.2, Providing and fixing ISI marked flush door shuttersconformingto IS:2202(PartI) ...shutter. 30mmthickincludingISImarked Stainless Steel butt hinges with necessary screws. |
| 163 | 3005856, 11.37.1, Kota stone slabs inrisers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar1:3…..shadeoftheslabs,including rubbing and polishing complete. 10-12 mm thick |
| 164 | 3005872, 11.46, Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. |
| 165 | 3005916, 11.76.1, Providing and laying vitrified floor tiles (without solublesalt)orprinted(withsolublesalt)Nano polished(Glossy finish)in differentsizeswith water absorption….Plain ivory light shade Size 600X600mm thickness 9-10mm |
| 166 | 3005918, 11.77.1, Providing and laying vitrified floor tiles (without solublesalt)orprinted(withsolublesalt)Nano polished(Glossy finish)in differentsizeswith water absorption... 1st quality/premiumqualityinskirting laid on 12mm thick... and matching pigments etc. complete Plain ivory light shade Size 600X600mm thickness 9-10mm |
| 167 | 3007210, 18.28, Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 168 | 3005665, 10.2, StructuralsteelworkusingM.S.flats, angles,channels I-section,H-sectionetc…. in positionand applyinga primingcoatof approved steel primer all complete. |
| 169 | 3005535, 9.166.1, Providing and fixing factory made 30 mm thick PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thicknessandsizeof19mmx19mmfor ........sideofthe \"C\"Channelusing PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification and drawing. Plain PVC door shutters. |
| 170 | 3005704, 10.21, Welding by gas or electric plant including transportationof plantatsiteetc. complete. |
| 171 | 3005899, 11.66, Providingandlayingfactorymademachine pressedprecast cementconcreteinterlocking paver block of any shape and size conforming to IS:15658- 2006 and ISI marked of 60 mm thickness,M-30 gradewithgreycementand pigment all as specified. Madeby block making machine with strong vibratory compaction, laid inrequired colour and patternover andincluding50mmthick compacted bed of stone dust, filling the joints with sand etc. all complete as per the direction of Engineer-in-Charge. |
| 172 | 3006650, 17.22.1, Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete. 10 litre capacity..White |
| 173 | 3006662, 17.29.2, Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings :..Flat back wash basin of size 550x400mm. |
| 174 | 3008184, 5.1.1.1, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary short point. (Using modular accessories) |
| 175 | 3008185, 5.1.1.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary medium point. (Using modular accessories) |
| 176 | 3008186, 5.1.1.3, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary long point. (Using modular accessories) |
| 177 | 3008191, 5.1.3.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- 3 Pin 6 Amp socket outlet on separate board Medium point. (Using modular accessories) |
| 178 | 3008194, 5.1.4.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Call bell/buzzer points Medium point. (Using modular accessories) |
| 179 | 3008199, 5.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside casing & capping with required materials as per specification on same board. .(Using modular accessories) |
| 180 | 3008180, 5.3.1, Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping of ISI marked suitable size etc. as required as per specification 2x2.5 Sq.mm ( Using flush type normal accessories) |
| 181 | 3008274, 10.1.1.2, Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :- On separate board Medium point. (Using modular accessories) |
| 182 | 3008275, 10.1.1.3, Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :- On separate board Long point. (Using modular accessories) |
| 183 | 3009107, 27.8.1.2, Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of \"C\" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single pole MCB SP 6Amp to 32Amp 10kA rating |
| 184 | 3009249, 27.23.1.1, Supply & fixing of approved make accepted standard sheet steel enclosure (dust protected) duly powder coated paint neutral bar suitable for MCB/RCBOs/MCCB of capacity as required etc. complete as per specification (exclusive of M.C.B./ MCCB/RCBOs) For MCB SP enclosure |
| 185 | 3009366, 29.25.2, Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board 100 Watt (2 module) |
| 186 | 3008368, 18.3.1, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-1 Or 2 Module PVC box |
| 187 | 3008370, 18.3.3, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-4 Module PVC box |
| 188 | 3008371, 18.3.4, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-6 Module PVC box |
| 189 | 3007524 ,22.14.1,Grading roof for receiving water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) |
| 190 | 3006376 ,14.65,Providing & casting & Repairing of excessively damaged memberswith micro-concrete at all levels with all leads & lift or as directed including formwork, centering, scaffolding, and mixing, laying, levelling, and finishing including curing etc. complete (excluding steel reinforcement |
| 191 | 3006415 ,14.80.1,Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: easurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2)-12 mm average thickness |
| 192 | 3007534 ,22.22,Water proofing treatment over Roof, Wall, Chajjas,, Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of(i) Surface preparation roughening of surface, opening cracks in ‘V’ groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely.(ii) Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80%-chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2ndcoat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow thecoating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per anufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). (iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hight build elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs. minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air cure for 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area.(iv) The treated area should be cure with water for 48 hrs. by flooding the surface.(v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee) |
| 193 | 3007542 ,22.3,Providing & applying crack fill paste for crack filling up to 5 mm cracks.Widen the crack by putty knife in V/U shape & apply 1st priming coat of crack fill paste diluted with water in 1:1 proportion over the crack by brush. |
| 194 | 220 KV S/S Pithampur Sec- III (Bagdon),3006279, 14.1.1, Repairs to plaster of thickness 12mm to 20mm in patches of area2.5sq.metresand….. dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4 sand). |
| 195 | 3004994, 6.5.2, Brickworkwithwellbruntopen bhatta,bricks,crushing strengthnot less than 25kg /cm2 and water absorptionnot morethan20%in foundationandplinthi/ccuringetc complete. Cement Mortar 1:6 (1 cement: 6 sand). |
| 196 | 3004838, 4.1.2.3, Providing and laying in position cement concrete of …. M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate |
| 197 | 3004929, 5.16.6, Reinforcement for R.C.C. work including straightening, cutting, bending, placing.....etc. complete . Thermo-Mechanically Treated bars. (TMT/TMX)FE500.separately as shown in the drawing and as per ....Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786 |
| 198 | 3004884, 5.1.1, Providing and laying in position specified grade of reinforced cement concrete (with 20mm ...reinforcement- All work up to plinth level : M-20 Grade Concrete |
| 199 | 3004893, 5.9.1, Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level |
| 200 | 3006325, 14.3, Removingdryoroilbound distemper, water proofing ….. repairs to scratches etc. complete. |
| 201 | 3006206, 13.41, Providing and applying white cement based putty of average thickness……. of APD/Chief Engineer will be required. |
| 202 | 3006924, 18.6.2.2, Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply …Charge...Concealed work including cutting chases and making good the walls etc...20 mm nominal outer dia .Pipes. |
| 203 | 3006929, 18.7.3, Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,..having thermal stability for hot and cold water supply including all CPVC……. of Engineer-in- Charge. External Work.25 mm nominal outer dia .Pipes. |
| 204 | 3007138, 18.14.3, Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore |
| 205 | 3007218, 18.34, Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore. |
| 206 | 3007665, 25.45, Providing and fixing in position best Indian Auto Closing 32mm, Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/cartridge). (Premium Range) |
| 207 | 3006809, 17.61, Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet |
| 208 | 3006644, 17.17.2, Providing and fixing white vitreous china water closet squatting pan (Indian type)..Orissa pattern W.C. pan of size 580x440 mm |
| 209 | 3006805, 17.59.5.1, Providing and fixing unplasticised PVC moulded fittings/ …..expansion..Bend 87.50..75 mm bend |
| 210 | 3006040, 12.33.3.2, Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for ….. Single tee with door 110x110x110 mm (minimum wall thickness 2.2mm) |
| 211 | 3006806, 17.59.5.2, Providing and fixing unplasticised PVC moulded fittings/ …..expansion..Bend 87.50....110 mm bend |
| 212 | 3004746, 2.6.1, Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas…….and neatly dressed.All kinds of soil |
| 213 | 3007292, 19.4.2, Providing and laying below…..paid seperataly...160 mm diameter OD (min. wall thickness 4.0mm) |
| 214 | 3006810, 19.4.1, Providing and laying below groundunplasticisedPVCpipe to withstandworkingpressure of4kg/cm2soildwaste pipes confirming toIS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving10mmgapfor thermal expansionallnecessaryfittings etc. complete. Excavation to be paid seperataly...110 mm diameter OD (min. wall thickness 3.2mm) |
| 215 | 3007297, 19.5.2, Providing and laying cement concrete 1:3:6 (1 cement: 3 sand:6gradedstoneaggregate 20mmnominalsize) all-round PVC. pipes including bed concrete as per standard design:..160 mm diameter PVC. pipe |
| 216 | 3007296, 19.5.1, Providing and laying cement concrete 1:3:6 (1 cement: 3 sand:6gradedstoneaggregate 20mmnominalsize) all-round PVC. pipes including bed concrete as per standard design:..110 mm diameter PVC. pipe |
| 217 | 3006034, 12.32.2, Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm diameter (minimum wall thickness 2.2mm) |
| 218 | 3007366,19.27.1,\"Constructing brick masonry manholeincementmortar1:4 ( 1 cement : 4 sand ) R.C.C. top slabwith....completeas per standard design :Inside size 90x80 cm and 45 cm deep includingC.I. coverwith frame (light duty) 455x610 mm internal dimensions total weight ofcoverandframetobenot less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :..With well burnt bricks\" |
| 219 | 3006637, 17.14.2.1, Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as …..required :..Kitchen sink without drain board..610x510 mm bowl depth 200 mm. |
| 220 | 3005828, 11.22.5, Providingandfixing18mmthickgangsawcut mirror polished(premoulded and prepolished) machinecutfor kitchen platforms,vanity counters, window sills , facias and similar locations of required size of approved shade, colourandtexturelaidover20mmthickbase cement mortar 1:4 (1 cement : 4 sand) with joints treated withwhitecement,mixed withmatching pigment, epoxy touch ups, including rubbing, curingmouldingand polishingtoedgetogive high gloss finish wherever required etc. complete atalllevels.Samplesapproved by Engineer-in- Charge. Cuddpah stone |
| 221 | 3005862, 11.41, Extraforprovidingopeningofrequiredsizeand shapefor washbasins/kitchensinkinkitchen platform,vanity counters andsimilarlocationin marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 222 | 3005877, 11.51, ProvidingandlayingrectifiedGlazedCeramic walltiles 300x450mmormore(thicknesstobe specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 12mmthickcementmortar1:3(1Cement:3 sand) includinggroutingthejointswithwhite cement and matching pigments etc., complete. |
| 223 | 3005876, 11.50, ProvidingandlayingrectifiedGlazedCeramic floor tiles 300x300 mm or more (having thickness9to10mm)of1st qualityconformingtoIS: 15622ofapprovedmakeinallcolourswhite, ivory, grey,fume redbrown laid on20mm thick cement mortar 1:4 (1 Cement : 4 sand) including grouting the joints with white cement and matching pigments etc., complete. |
| 224 | 3006816, 17.64.1.1, Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete..Semi rigid pipe..32 mm dia |
| 225 | 3006211, 13.46, Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work |
| 226 | 3006822, 13.64, Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 227 | 3007215, 18.31, Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, 15 mm nominal bore. |
| 228 | 3007216, 18.32, Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore. |
| 229 | 3006357, 14.52.1, Finishing walls with Premium Acrylic Smooth exterior paint withSiliconeadditivesof required shade..Oldwork (Twoormorecoats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. |
| 230 | 3007228, 18.43.2, Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :..150 mm diameter |
| 231 | 3006622, 17.11.4, Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. …..:White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 232 | 3005212, 9.18.2, Providing and fixing ISI marked flush door shuttersconformingto IS:2202(PartI) ...shutter. 30mmthickincludingISImarked Stainless Steel butt hinges with necessary screws. |
| 233 | 3005916, 11.76.1, Providing and laying vitrified floor tiles (without solublesalt)orprinted(withsolublesalt)Nano polished(Glossy finish)in differentsizeswith water absorption….Plain ivory light shade Size 600X600mm thickness 9-10mm |
| 234 | 3005918, 11.77.1, Providing and laying vitrified floor tiles (without solublesalt)orprinted(withsolublesalt)Nano polished(Glossy finish)in differentsizeswith water absorption... 1st quality/premiumqualityinskirting laid on 12mm thick... and matching pigments etc. complete Plain ivory light shade Size 600X600mm thickness 9-10mm |
| 235 | 3007210, 18.28, Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 236 | 3005665, 10.2, StructuralsteelworkusingM.S.flats, angles,channels I-section,H-sectionetc…. in positionand applyinga primingcoatof approved steel primer all complete. |
| 237 | 3005535, 9.166.1, Providing and fixing factory made 30 mm thick PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thicknessandsizeof19mmx19mmfor ........sideofthe \"C\"Channelusing PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification and drawing. Plain PVC door shutters. |
| 238 | 3006650, 17.22.1, Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete. 10 litre capacity..White |
| 239 | 3006662, 17.29.2, Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings :..Flat back wash basin of size 550x400mm. |
| 240 | 3008164, 5.1.1.1, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary short point. (Using modular accessories) |
| 241 | 3008185,5.1.1.2,Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary medium point. (Using modular accessories) |
| 242 | 3008186, 5.1.1.3, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary long point. (Using modular accessories) |
| 243 | 3008191, 5.1.3.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- 3 Pin 6 Amp socket outlet on separate board Medium point. (Using modular accessories) |
| 244 | 3008194, 5.1.4.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Call bell/buzzer points Medium point. (Using modular accessories) |
| 245 | 3008199, 5.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside casing & capping with required materials as per specification on same board. .(Using modular accessories) |
| 246 | 3008200, 5.3.1, Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping of ISI marked suitable size etc. as required as per specification 2x2.5 Sq.mm ( Using flush type normal accessories) |
| 247 | 3008274, 10.1.1.2, Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :- On separate board Medium point. (Using modular accessories) |
| 248 | 3008275, 10.1.1.3, Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :- On separate board Long point. (Using modular accessories) |
| 249 | 3009107, 27.8.1.2, Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of \"C\" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single pole MCB SP 6Amp to 32Amp 10kA rating |
| 250 | 3009249, 27.23.1.1, Supply & fixing of approved make accepted standard sheet steel enclosure (dust protected) duly powder coated paint neutral bar suitable for MCB/RCBOs/MCCB of capacity as required etc. complete as per specification (exclusive of M.C.B./ MCCB/RCBOs) For MCB SP enclosure |
| 251 | 3009366, 29.25.2, Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board 100 Watt (2 module) |
| 252 | 3006848, 18.3.1, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-1 Or 2 Module PVC box |
| 253 | 3006849, 18.3.2, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-3 Module PVC box |
| 254 | 3006850, 18.3.3, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-4 Module PVC box |
| 255 | 3006851, 18.3.4, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-6 Module PVC box |
| 256 | 3007524 ,22.14.1,Grading roof for receiving water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) |
| 257 | 3006376 ,14.65,Providing & casting & Repairing of excessively damaged memberswith micro-concrete at all levels with all leads & lift or as directed including formwork, centering, scaffolding, and mixing, laying, levelling, and finishing including curing etc. complete (excluding steel reinforcement |
| 258 | 3006415 ,14.80.1,Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: easurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2)-12 mm average thickness |
| 259 | 3007534 ,22.22,Water proofing treatment over Roof, Wall, Chajjas,, Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of(i) Surface preparation roughening of surface, opening cracks in ‘V’ groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely.(ii) Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80%-chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2ndcoat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow thecoating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per anufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). (iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hight build elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs. minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air cure for 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area.(iv) The treated area should be cure with water for 48 hrs. by flooding the surface.(v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee) |
| 260 | 3007542 ,22.3,Providing & applying crack fill paste for crack filling up to 5 mm cracks.Widen the crack by putty knife in V/U shape & apply 1st priming coat of crack fill paste diluted with water in 1:1 proportion over the crack by brush. |
| 261 | 132 KV S/S Colony Dhamnod, 3006279, 14.1.1, Repairs to plaster of thickness 12mm to 20mm in patches of area2.5sq.metresand….. dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4 sand). |
| 262 | 3004994, 6.5.2, Brickworkwithwellbruntopen bhatta,bricks,…..foundationandplinthi/ccuringetc complete. Cement Mortar 1:6 (1 cement: 6 sand). |
| 263 | 3004838, 4.1.2.3, Providing and laying in position cement concrete of …. M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate |
| 264 | 3004929, 5.16.6,Reinforcement for R.C.C. work including straightening, cutting, bending, placing.....etc. complete . Thermo-Mechanically Treated bars. (TMT/TMX)FE500.separately as shown in the drawing and as per ....Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786 |
| 265 | 3004884,5.1.1,Providing and laying in position specified grade of reinforced cement concrete (with 20mm ...reinforcement- All work up to plinth level : M-20 Grade Concrete |
| 266 | 3004893, 5.9.1, Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level |
| 267 | 3004894, 5.9.2, Centering and shuttering in cluding strutting, propping etc. and removal of form for: Walls(anythickness) in cludingattached pilasters butter esses, plinth beams and string courses etc. Uptoplinthlevel. |
| 268 | 3004897, 5.9.3, Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform. |
| 269 | 3006494, 15.40, Dismantling G.I. pipes (external work) including excavation and refilling trenches…..-Charge :.15 mm to 40 mm nominal bore |
| 270 | 3006325, 14.30, Removingdryoroilbound distemper, water proofing ….. repairs to scratches etc. complete. |
| 271 | 3006206, 13.41, Providing and applying white cement based putty of average thickness……. of APD/Chief Engineer will be required. |
| 272 | 3006924, 18.6.2.2, Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply …Charge...Concealed work including cutting chases and making good the walls etc...20 mm nominal outer dia .Pipes. |
| 273 | 3006931,18.7.5, Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,..having thermal stability for hot and cold water supply including all CPVC……..of Engineer-in- Charge. External Work..40 mm nominal outer dia .Pipes. |
| 274 | 3006929, 18.7.3, Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,..having thermal stability for hot and cold water supply including all CPVC……. of Engineer-in- Charge. External Work.25 mm nominal outer dia .Pipes. |
| 275 | 3007138, 18.14.3, Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore |
| 276 | 3007218, 18.34, Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore. |
| 277 | 3007665, 25.45, Providing and fixing in position best Indian Auto Closing 32mm, Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/cartridge). (Premium Range) |
| 278 | 3006809, 17.61, Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet |
| 279 | 3006644, 17.17.2, Providing and fixing white vitreous china water closet squatting pan (Indian type)..Orissa pattern W.C. pan of size 580x440 mm |
| 280 | 3006805,17.59.5.1,Providing and fixing unplasticised PVC moulded fittings/ …..expansion..Bend 87.50..75 mm bend |
| 281 | 3006040, 12.33.3.2, Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for ….. Single tee with door 110x110x110 mm (minimum wall thickness 2.2mm) |
| 282 | 3006806, 17.59.5.2,Providing and fixing unplasticised PVC moulded fittings/ …..expansion..Bend 87.50....110 mm bend |
| 283 | 3004746, 2.6.1, Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas…….and neatly dressed.All kinds of soil |
| 284 | 3007292, 19.4.2, Providing and laying below…..paid seperataly...160 mm diameter OD (min. wall thickness 4.0mm) |
| 285 | 3007291,19.4.1, Providing and laying below groundunplasticisedPVCpipe to withstandworkingpressure of4kg/cm2soildwaste pipes confirming toIS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving10mmgapfor thermal expansionallnecessaryfittings etc. complete. Excavation to be paid seperataly...110 mm diameter OD (min. wall thickness 3.2mm) |
| 286 | 3007297, 19.5.2, Providing and laying cement concrete 1:3:6 (1 cement: 3 sand:6gradedstoneaggregate 20mmnominalsize) all-round PVC. pipes including bed concrete as per standard design:..160 mm diameter PVC. pipe |
| 287 | 3007296, 19.5.1,Providing and laying cement concrete 1:3:6 (1 cement: 3 sand:6gradedstoneaggregate 20mmnominalsize) all-round PVC. pipes including bed concrete as per standard design:..110 mm diameter PVC. pipe |
| 288 | 3006033, 12.32.2, Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm diameter (minimum wall thickness 2.2mm) |
| 289 | 3007366,19.27.1, \"Constructing brick masonry manholeincementmortar1:4 ( 1 cement : 4 sand ) R.C.C. top slabwith....completeas per standard design :Inside size 90x80 cm and 45 cm deep includingC.I. coverwith frame (light duty) 455x610 mm internal dimensions total weight ofcoverandframetobenot less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :..With well burnt bricks\" |
| 290 | 3006637, 17.14.2.1, Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required :..Kitchen sink without drain board..610x510 mm bowl depth 200 mm. |
| 291 | 3005828, 11.22.5, Providingandfixing18mmthickgangsawcut mirror polished(premoulded and prepolished) machinecutfor kitchen platforms,vanity counters, window sills , facias and similar locations of required size of approved shade, colourandtexturelaidover20mmthickbase cement mortar 1:4 (1 cement : 4 sand) with joints treated withwhitecement,mixed withmatching pigment, epoxy touch ups, including rubbing, curingmouldingand polishingtoedgetogive high gloss finish wherever required etc. complete atalllevels.Samplesapproved by Engineer-in- Charge. Cuddpah stone |
| 292 | 3005862, 11.41, Extraforprovidingopeningofrequiredsizeand shapefor washbasins/kitchensinkinkitchen platform,vanity counters andsimilarlocationin marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 293 | 3005877, 11.51, ProvidingandlayingrectifiedGlazedCeramic walltiles 300x450mmormore(thicknesstobe specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 12mmthickcementmortar1:3(1Cement:3 sand) includinggroutingthejointswithwhite cement and matching pigments etc., complete. |
| 294 | 3005876, 11.50, ProvidingandlayingrectifiedGlazedCeramic floor tiles 300x300 mm or more (having thickness9to10mm)of1st qualityconformingtoIS: 15622ofapprovedmakeinallcolourswhite, ivory, grey,fume redbrown laid on20mm thick cement mortar 1:4 (1 Cement : 4 sand) including grouting the joints with white cement and matching pigments etc., complete. |
| 295 | 3006816, 17.64.1.1, Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete..Semi rigid pipe..32 mm dia |
| 296 | 3006211, 13.46, Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work |
| 297 | 3006240, 13.64, Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 298 | 3006289, 14.7.1, Renewing glass panes and refixing existing wooden fillets: Float glass panes of thickness 4 mm |
| 299 | 3006291, 14.8.1, Supplying andfixing new woodenfillets wherever necessary: 2nd class teak wood fillets |
| 300 | 3007215, 18.31, Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, 15 mm nominal bore. |
| 301 | 3007216, 18.32, Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore. |
| 302 | 3006357, 14.52.1, Finishing walls with Premium Acrylic Smooth exterior paint withSiliconeadditivesof required shade..Oldwork (Twoormorecoats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. |
| 303 | 3007228, 18.43.2, Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :..150 mm diameter |
| 304 | 3006622, 17.11.4, Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. …..:White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 305 | 3005212, 9.18.2,Providing and fixing ISI marked flush door shuttersconformingto IS:2202(PartI) ...shutter. 30mmthickincludingISImarked Stainless Steel butt hinges with necessary screws. |
| 306 | 3005856, 11.37.1, Kota stone slabs inrisers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar1:3…..shadeoftheslabs,including rubbing and polishing complete. 10-12 mm thick |
| 307 | 3005872, 11.46, Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. |
| 308 | 3005916, 11.76.1, Providing and laying vitrified floor tiles (without solublesalt)orprinted(withsolublesalt)Nano polished(Glossy finish)in differentsizeswith water absorption….Plain ivory light shade Size 600X600mm thickness 9-10mm |
| 309 | 3005918, 11.77.1, Providing and laying vitrified floor tiles (without solublesalt)orprinted(withsolublesalt)Nano polished(Glossy finish)in differentsizeswith water absorption... 1st quality/premiumqualityinskirting laid on 12mm thick... and matching pigments etc. complete Plain ivory light shade Size 600X600mm thickness 9-10mm |
| 310 | 3007210, 18.28, Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 311 | 3005665,10.2,StructuralsteelworkusingM.S.flats, angles,channels I-section,H-sectionetc…. in positionand applyinga primingcoatof approved steel primer all complete. |
| 312 | 3005535, 9.166.1, Providing and fixing factory made 30 mm thick PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thicknessandsizeof19mmx19mmfor ........sideofthe \"C\"Channelusing PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification and drawing. Plain PVC door shutters. |
| 313 | 3009712, 39.9.1 Electric, Supplying & installation of approved make required capacity 3 phase, 50 Hz, 415V, centrifugal mono-block pump, with starter i/c single phase preventer, connections, base channel foundation etc. as required as per specifications but excluding pipe and connection cable.3.0 HP head metre 6-15, discharge LPM 1200-1000 |
| 314 | 3009699, 39.3.2, Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. 4.0 sq.mm multi strand |
| 315 | 3008184, 5.1.1.1, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary short point. (Using modular accessories) |
| 316 | 3008185, 5.1.1.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary medium point. (Using modular accessories) |
| 317 | 3008186, 5.1.1.3, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary long point. (Using modular accessories) |
| 318 | 3008191, 5.1.3.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- 3 Pin 6 Amp socket outlet on separate board Medium point. (Using modular accessories) |
| 319 | 3008194, 5.1.4.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Call bell/buzzer points Medium point. (Using modular accessories) |
| 320 | 3008199, 5.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside casing & capping with required materials as per specification on same board. .(Using modular accessories) |
| 321 | 3008180, 5.3.1, Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping of ISI marked suitable size etc. as required as per specification 2x2.5 Sq.mm ( Using flush type normal accessories) |
| 322 | 3008274, 10.1.1.2, Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :- On separate board Medium point. (Using modular accessories) |
| 323 | 3008275, 10.1.1.3, Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :- On separate board Long point. (Using modular accessories) |
| 324 | 3009107, 27.8.1.2, Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of \"C\" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single pole MCB SP 6Amp to 32Amp 10kA rating |
| 325 | 3009249, 27.23.1.1, Supply & fixing of approved make accepted standard sheet steel enclosure (dust protected) duly powder coated paint neutral bar suitable for MCB/RCBOs/MCCB of capacity as required etc. complete as per specification (exclusive of M.C.B./ MCCB/RCBOs) For MCB SP enclosure |
| 326 | 3009366, 29.25.2, Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board 100 Watt (2 module) |
| 327 | 3008368, 18.3.1, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-1 Or 2 Module PVC box |
| 328 | 3008370, 18.3.3, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-4 Module PVC box |
| 329 | 3008371, 18.3.4, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-6 Module PVC box |
| 330 | 3007524 ,22.14.1,Grading roof for receiving water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) |
| 331 | 3006376 ,14.65,Providing & casting & Repairing of excessively damaged memberswith micro-concrete at all levels with all leads & lift or as directed including formwork, centering, scaffolding, and mixing, laying, levelling, and finishing including curing etc. complete (excluding steel reinforcement |
| 332 | 3006415 ,14.80.1,Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: easurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2)-12 mm average thickness |
| 333 | 3007534 ,22.22,Water proofing treatment over Roof, Wall, Chajjas,, Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of(i) Surface preparation roughening of surface, opening cracks in ‘V’ groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely.(ii) Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80%-chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2ndcoat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow thecoating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per anufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). (iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hight build elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs. minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air cure for 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area.(iv) The treated area should be cure with water for 48 hrs. by flooding the surface.(v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee) |
| 334 | 3007542 ,22.3,Providing & applying crack fill paste for crack filling up to 5 mm cracks.Widen the crack by putty knife in V/U shape & apply 1st priming coat of crack fill paste diluted with water in 1:1 proportion over the crack by brush. |
| 335 | 400 KV S/S Colony Indore, 3006279, 14.1.1, Repairs to plaster of thickness 12mm to 20mm in patches of area2.5sq.metresand….. dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4 sand). |
| 336 | 3004994, 6.5.2, Brickworkwithwellbruntopen bhatta,bricks,crushing strengthnot less than 25kg /cm2 and water absorptionnot morethan20%in foundationandplinthi/ccuringetc complete. Cement Mortar 1:6 (1 cement: 6 sand). |
| 337 | 3006149, 13.3.2, 20 mm cement plaster of mix : 1:6 (1 cement : 6 sand) |
| 338 | 3004838, 4.1.2.3, Providing and laying in position cement concrete of …. M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate |
| 339 | 3004929, 5.16.6, Reinforcement for R.C.C. work including straightening, cutting, bending, placing.....etc. complete . Thermo-Mechanically Treated bars. (TMT/TMX)FE500.separately as shown in the drawing and as per ....Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786 |
| 340 | 3004884, 5.1.1, Providing and laying in position specified grade of reinforced cement concrete (with 20mm ...reinforcement- All work up to plinth level : M-20 Grade Concrete |
| 341 | 3006494, 15.40, Dismantling G.I. pipes (external work) including excavation and refilling trenches…..-Charge :.15 mm to 40 mm nominal bore |
| 342 | 3006325, 14.30, Removingdryoroilbound distemper, water proofing ….. repairs to scratches etc. complete. |
| 343 | 3006206, 13.41, Providing and applying white cement based putty of average thickness……. of APD/Chief Engineer will be required. |
| 344 | 3006923, 18.6.2.1, Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittingsi/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge...Concealed work including cutting chases and making good the walls etc...15 mm nominal outer dia .Pipes. |
| 345 | 3006924, 18.6.2.2, Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply Charge… Concealed work including cutting chases and making good the walls etc...20 mm nominal outer dia .Pipes. |
| 346 | 3007137, 18.14.2, Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :..20 mm nominal bore |
| 347 | 3007218, 18.34, Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore. |
| 348 | 3006650, 17.22.1, Providing and fixing in position best Indian Auto Closing 32mm, Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/cartridge). (Premium Range) |
| 349 | 3006809, 17.61, Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet |
| 350 | 3006644, 17.17.2, Providing and fixing white vitreous china water closet squatting pan (Indian type)..Orissa pattern W.C. pan of size 580x440 mm |
| 351 | 3006805, 17.59.5.1, Providing and fixing unplasticised PVC moulded fittings/ …..expansion..Bend 87.50..75 mm bend |
| 352 | 3006040, 12.33.3.2, Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for ….. Single tee with door 110x110x110 mm (minimum wall thickness 2.2mm) |
| 353 | 3006806, 17.59.5.2, Providing and fixing unplasticised PVC moulded fittings/ …..expansion..Bend 87.50....110 mm bend |
| 354 | 3004746, 2.6.1, Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas…….and neatly dressed.All kinds of soil |
| 355 | 3007292, 19.4.2, Providing and laying below…..paid seperataly...160 mm diameter OD (min. wall thickness 4.0mm) |
| 356 | 3007291,19.4.1,Providing and laying below groundunplasticisedPVCpipe to withstandworkingpressure of4kg/cm2soildwaste pipes confirming toIS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving10mmgapfor thermal expansionallnecessaryfittings etc. complete. Excavation to be paid seperataly...110 mm diameter OD (min. wall thickness 3.2mm) |
| 357 | 3007297, 19.5.2, Providing and laying cement concrete 1:3:6 (1 cement: 3 sand:6gradedstoneaggregate 20mmnominalsize) all-round PVC. pipes including bed concrete as per standard design:..160 mm diameter PVC. pipe |
| 358 | 3007296, 19.5.1, Providing and laying cement concrete 1:3:6 (1 cement: 3 sand:6gradedstoneaggregate 20mmnominalsize) all-round PVC. pipes including bed concrete as per standard design:..110 mm diameter PVC. pipe |
| 359 | 3006033, 12.32.2, Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm diameter (minimum wall thickness 2.2mm) |
| 360 | 3007319, 19.9.1.1, \"Constructing brick masonry manholeincementmortar1:4 ( 1 cement : 4 sand ) R.C.C. top slabwithCement Concrete 1:2:4 mix(1 cement : 2 sand: 4 graded stone aggregate 20 mmnominalsize),foundation concrete 1:2:4 mix(1 cement : 2 sand:4gradedstone aggregate20mmnominalsize) inside plastering 12mm thick withcementmortar1:3 (1 cement:3sand)finishedwith floating coat of neat cement and makingchannelsin cement concrete1:2:4(1cement: 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cementcompleteas per standard design :Inside size 90x80 cm and 45 cm deep includingC.I. coverwith frame (light duty) 455x610 mm internal dimensions total weight ofcoverandframetobenot less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :..With well burnt bricks\" |
| 361 | 3006637, 17.14.2.1, Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required :..Kitchen sink without drain board..610x510 mm bowl depth 200 mm. |
| 362 | 3005828, 11.22.5, Providingandfixing18mmthickgangsawcut mirror polished(premoulded and prepolished) machinecutfor kitchen platforms,vanity counters, window sills , facias and similar locations of required size of approved shade, colourandtexturelaidover20mmthickbase cement mortar 1:4 (1 cement : 4 sand) with joints treated withwhitecement,mixed withmatching pigment, epoxy touch ups, including rubbing, curingmouldingand polishingtoedgetogive high gloss finish wherever required etc. complete atalllevels.Samplesapproved by Engineer-in- Charge. Cuddpah stone |
| 363 | 3005860, 11.39.2, Providingedgemouldingto18mmthickmarble stonecounters, Vanities,windowsillsetc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work. |
| 364 | 3005862, 11.41, Extraforprovidingopeningofrequiredsizeand shapefor washbasins/kitchensinkinkitchen platform,vanity counters andsimilarlocationin marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 365 | 3005877, 11.51, ProvidingandlayingrectifiedGlazedCeramic walltiles 300x450mmormore(thicknesstobe specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 12mmthickcementmortar1:3(1Cement:3 sand) includinggroutingthejointswithwhite cement and matching pigments etc., complete. |
| 366 | 3005876, 11.50,ProvidingandlayingrectifiedGlazedCeramic floor tiles 300x300 mm or more (having thickness9to10mm)of1st qualityconformingtoIS: 15622ofapprovedmakeinallcolourswhite, ivory, grey,fume redbrown laid on20mm thick cement mortar 1:4 (1 Cement : 4 sand) including grouting the joints with white cement and matching pigments etc., complete. |
| 367 | 3006816, 17.64.1.1, Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete..Semi rigid pipe..32 mm dia |
| 368 | 3006211, 13.46, Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work |
| 369 | 3006240, 13.64, Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 370 | 3006289, 14.7.1, Renewing glass panes and refixing existing wooden fillets: Float glass panes of thickness 4 mm |
| 371 | 3006291, 14.8.1, Supplying andfixing new woodenfillets wherever necessary: 2nd class teak wood fillets |
| 372 | 3007215, 18.31, Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, 15 mm nominal bore. |
| 373 | 3007216, 18.32, Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore. |
| 374 | 3006357, 14.52.1, Finishing walls with Premium Acrylic Smooth exterior paint withSiliconeadditivesof required shade..Oldwork (Twoormorecoats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. |
| 375 | 3006622, 17.11.4, Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. …..:White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 376 | 3005212, 9.18.2, Providing and fixing ISI marked flush door shuttersconformingto IS:2202(PartI) ...shutter. 30mmthickincludingISImarked Stainless Steel butt hinges with necessary screws. |
| 377 | 3005856, 11.37.1, Kota stone slabs inrisers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar1:3…..shadeoftheslabs,including rubbing and polishing complete. 10-12 mm thick |
| 378 | 3005916, 11.76.1, Providing and laying vitrified floor tiles (without solublesalt)orprinted(withsolublesalt)Nano polished(Glossy finish)in differentsizeswith water absorption….Plain ivory light shade Size 600X600mm thickness 9-10mm |
| 379 | 3005918, 11.77.1, Providing and laying vitrified floor tiles (without solublesalt)orprinted(withsolublesalt)Nano polished(Glossy finish)in differentsizeswith water absorption... 1st quality/premiumqualityinskirting laid on 12mm thick... and matching pigments etc. complete Plain ivory light shade Size 600X600mm thickness 9-10mm |
| 380 | 3007210, 18.28, Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 381 | StructuralsteelworkusingM.S.flats, angles,channels I-section,H-sectionetc…. in positionand applyinga primingcoatof approved steel primer all complete. |
| 382 | Providing and fixing factory made 30 mm thick PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thicknessandsizeof19mmx19mmfor ........sideofthe \"C\"Channelusing PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification and drawing. Plain PVC door shutters. |
| 383 | 3008184, 5.1.1.1,Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary short point. (Using modular accessories) |
| 384 | 3008185, 5.1.1.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary medium point. (Using modular accessories) |
| 385 | 3008186, 5.1.1.3, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary long point. (Using modular accessories) |
| 386 | 3008191, 5.1.3.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- 3 Pin 6 Amp socket outlet on separate board Medium point. (Using modular accessories) |
| 387 | 3008194, 5.1.4.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Call bell/buzzer points Medium point. (Using modular accessories) |
| 388 | 3008199,5.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside casing & capping with required materials as per specification on same board. .(Using modular accessories) |
| 389 | 3008180, 5.3.1, Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping of ISI marked suitable size etc. as required as per specification 2x2.5 Sq.mm ( Using flush type normal accessories) |
| 390 | 3008274, 10.1.1.2, Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :- On separate board Medium point. (Using modular accessories) |
| 391 | 3008275, 10.1.1.3, Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :- On separate board Long point. (Using modular accessories) |
| 392 | 3009107, 27.8.1.2, Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of \"C\" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single pole MCB SP 6Amp to 32Amp 10kA rating |
| 393 | 3009249, 27.23.1.1, Supply & fixing of approved make accepted standard sheet steel enclosure (dust protected) duly powder coated paint neutral bar suitable for MCB/RCBOs/MCCB of capacity as required etc. complete as per specification (exclusive of M.C.B./ MCCB/RCBOs) For MCB SP enclosure |
| 394 | 3009366, 29.25.2, Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board 100 Watt (2 module) |
| 395 | 3008368, 18.3.1, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-1 Or 2 Module PVC box |
| 396 | 3008369, 18.3.2, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-3 Module PVC box |
| 397 | 3008370, 18.3.3, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-4 Module PVC box |
| 398 | 3008371, 18.3.4, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-6 Module PVC box |
| 399 | 3008372, 18.3.5, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-8/9 Module PVC box |
| 400 | 3008373, 18.3.6, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-12 Module PVC box |
| 401 | 3007524 ,22.14.1,Grading roof for receiving water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) |
| 402 | 3006376 ,14.65,Providing & casting & Repairing of excessively damaged memberswith micro-concrete at all levels with all leads & lift or as directed including formwork, centering, scaffolding, and mixing, laying, levelling, and finishing including curing etc. complete (excluding steel reinforcement |
| 403 | 3006415 ,14.80.1,Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: easurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2)-12 mm average thickness |
| 404 | 3007534 ,22.22,Water proofing treatment over Roof, Wall, Chajjas,, Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of(i) Surface preparation roughening of surface, opening cracks in ‘V’ groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely.(ii) Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80%-chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2ndcoat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow thecoating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per anufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). (iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hight build elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs. minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air cure for 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area.(iv) The treated area should be cure with water for 48 hrs. by flooding the surface.(v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee) |
| 405 | 3007542 ,22.3,Providing & applying crack fill paste for crack filling up to 5 mm cracks.Widen the crack by putty knife in V/U shape & apply 1st priming coat of crack fill paste diluted with water in 1:1 proportion over the crack by brush. |
| 406 | 220 KV S/S South Zone Colony Indore, 3006279, 14.1.1, Repairs to plaster of thickness 12mm to 20mm in patches of area2.5sq.metresand….. dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4 sand). |
| 407 | 3006144, 13.1.1, 12 mm cement plaster of mix : 1:4 (1 cement : 4 sand) |
| 408 | 3006149, 13.3.2, 20 mm cement plaster of mix : 1:6 (1 cement : 6 sand) |
| 409 | 3007515, 22.50,\"Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a).......joints, corners, junctions of pipes and masonry with polymer mixed slurry.\" |
| 410 | 3006435, 15.2.1, Demolishing cement concrete manually/by..Engineer-in- Charge: Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). |
| 411 | 3004740, 2.3, Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 412 | 3006455, 15.14.1, Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below. |
| 413 | 3004838, 4.1.2.3, Providing and laying in position cement concrete of …. M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate |
| 414 | 3004929, 5.16.6, Reinforcement for R.C.C. work including straightening, cutting, bending, placing.....etc. complete . Thermo-Mechanically Treated bars. (TMT/TMX)FE500.separately as shown in the drawing and as per ....Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786 |
| 415 | 3004884, 5.1.1, Providing and laying in position specified grade of reinforced cement concrete (with 20mm ...reinforcement- All work up to plinth level : M-20 Grade Concrete |
| 416 | 3006494, 15.40, Dismantling G.I. pipes (external work) including excavation and refilling trenches…..-Charge :.15 mm to 40 mm nominal bore |
| 417 | 3006325, 14.30, Removingdryoroilbound distemper, water proofing ….. repairs to scratches etc. complete. |
| 418 | 3006206, 13.41, Providing and applying white cement based putty of average thickness……. of APD/Chief Engineer will be required. |
| 419 | 3006923, 18.6.2.1, Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittingsi/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge...Concealed work including cutting chases and making good the walls etc...15 mm nominal outer dia .Pipes. |
| 420 | 3006924, 18.6.2.2, Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply Charge… Concealed work including cutting chases and making good the walls etc...20 mm nominal outer dia .Pipes. |
| 421 | 3007136, 18.14.1, Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :..15 mm nominal bore |
| 422 | 3007218, 18.34, Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore. |
| 423 | 3007665, 25.45, Providing and fixing in position best Indian Auto Closing 32mm, Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/cartridge). (Premium Range) |
| 424 | 3006809, 17.61, Providing and fixing UPVC trap of self cleaning ..wall and floors. 100 mm inlet and 75 mm outlet |
| 425 | 3006644, 17.17.2,Providing and fixing white vitreous china water closet squatting pan (Indian type)..Orissa pattern W.C. pan of size 580x440 mm |
| 426 | 3006805, 17.59.5.1, Providing and fixing unplasticised PVC moulded fittings/ …..expansion..Bend 87.50..75 mm bend |
| 427 | 3006040, 12.33.3.2, Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for ….. Single tee with door 110x110x110 mm (minimum wall thickness 2.2mm) |
| 428 | 3006806, 17.59.5.2, Providing and fixing unplasticised PVC moulded fittings/ …..expansion..Bend 87.50....110 mm bend |
| 429 | 3004746, 2.6.1, Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas…….and neatly dressed.All kinds of soil |
| 430 | 3007292, 19.4.2, Providing and laying below…..paid seperataly...160 mm diameter OD (min. wall thickness 4.0mm) |
| 431 | 3007291, 19.4.1, Providing and laying below groundunplasticisedPVCpipe to withstandworkingpressure of4kg/cm2soildwaste pipes confirming toIS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving10mmgapfor thermal expansionallnecessaryfittings etc. complete. Excavation to be paid seperataly...110 mm diameter OD (min. wall thickness 3.2mm) |
| 432 | 3007297, 19.5.2, Providing and laying cement concrete 1:3:6 (1 cement: 3 sand:6gradedstoneaggregate 20mmnominalsize) all-round PVC. pipes including bed concrete as per standard design:..160 mm diameter PVC. pipe |
| 433 | 3007296, 19.5.1, Providing and laying cement concrete 1:3:6 (1 cement: 3 sand:6gradedstoneaggregate 20mmnominalsize) all-round PVC. pipes including bed concrete as per standard design:..110 mm diameter PVC. pipe |
| 434 | 3006033, 12.32.2, Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes….expansion. 110 mm diameter (minimum wall thickness 2.2mm) |
| 435 | 3007319,19.9.1.1,\"Constructing brick masonry manholeincementmortar1:4 ( 1 cement : 4 sand ) R.C.C. top slabwithCement Concrete 1:2:4 mix(1 cement : 2 sand: 4 graded stone aggregate 20 mmnominalsize),foundation concrete 1:2:4 mix(1 cement : 2 sand:4gradedstone aggregate20mmnominalsize) inside plastering 12mm thick withcementmortar1:3 (1 cement:3sand)finishedwith floating coat of neat cement and makingchannelsin cement concrete1:2:4(1cement: 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cementcompleteas per standard design :Inside size 90x80 cm and 45 cm deep includingC.I. coverwith frame (light duty) 455x610 mm internal dimensions total weight ofcoverandframetobenot less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :..With well burnt bricks\" |
| 436 | 3006637, 17.14.2.1, Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required :..Kitchen sink without drain board..610x510 mm bowl depth 200 mm. |
| 437 | 3005828, 11.22.5, Providingandfixing18mmthickgangsawcut mirror polished(premoulded and prepolished) machinecutfor kitchen platforms,vanity counters, window sills , facias and similar locations of required size of approved shade, colourandtexturelaidover20mmthickbase cement mortar 1:4 (1 cement : 4 sand) with joints treated withwhitecement,mixed withmatching pigment, epoxy touch ups, including rubbing, curingmouldingand polishingtoedgetogive high gloss finish wherever required etc. complete atalllevels.Samplesapproved by Engineer-in- Charge. Cuddpah stone |
| 438 | 3005862, 11.41, Extraforprovidingopeningofrequiredsizeand shapefor washbasins/kitchensinkinkitchen platform,vanity counters andsimilarlocationin marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 439 | 3005877, 11.51, ProvidingandlayingrectifiedGlazedCeramic walltiles 300x450mmormore(thicknesstobe specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 12mmthickcementmortar1:3(1Cement:3 sand) includinggroutingthejointswithwhite cement and matching pigments etc., complete. |
| 440 | 3005876, 11.50, ProvidingandlayingrectifiedGlazedCeramic floor tiles 300x300 mm or more (having thickness9to10mm)of1st qualityconformingtoIS: 15622ofapprovedmakeinallcolourswhite, ivory, grey,fume redbrown laid on20mm thick cement mortar 1:4 (1 Cement : 4 sand) including grouting the joints with white cement and matching pigments etc., complete. |
| 441 | 3006816, 17.64.1.1, Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete..Semi rigid pipe..32 mm dia |
| 442 | 3006211, 13.46, Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work |
| 443 | 3005535, 9.166.1, Providing and fixing factory made 30 mm thick PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thicknessandsizeof19mmx19mmfor stylesand15x15mmfortopandbottom rails. M.S. frame shall have a coat of steel primersofapprovedmakeand manufacture. M.S. frame covered with 5mm thick heat moulded PVC \"C\" channel ofsize30mm thickness,70mmwidthout ofwhich50mmshallbeflatand 20mm shall be tapered in 45degree angle on both side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall beflat and20mmshallbetaperedin45 degreeontheinnersidetoformtopand bottomrailand115mmwidePVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail.Top,bottomandlockrailsshallbe providedboth sideofthepanel.10mm (5mmx2)thick,20mmwidecrossPVC sheet be provided as gap insert for top rail andbottomrail. panelingof5mmthick bothsidePVCsheettobefittedin the M.S. frame welded/ sealed to the styles and rails with 7mm (5mm+2mm) thick x 15mmwidePVCsheetbeadingoninner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interiorsideofthe \"C\"Channelusing PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification and drawing. Plain PVC door shutters. |
| 444 | 3006240, 13.64, Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 445 | 3006289, 14.7.1, Renewing glass panes and refixing existing wooden fillets: Float glass panes of thickness 4 mm |
| 446 | 3006291, 14.8.1, Supplying andfixing new woodenfillets wherever necessary: 2nd class teak wood fillets |
| 447 | 3007215, 18.31, Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, 15 mm nominal bore. |
| 448 | 3007216, 18.32, Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore. |
| 449 | 3006357, 14.52.1, Finishing walls with Premium Acrylic Smooth exterior paint withSiliconeadditivesof required shade..Oldwork (Twoormorecoats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. |
| 450 | 3006622, 17.11.4, Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm….require :White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 451 | 3005212, 9.18.2, Providing and fixing ISI marked flush door shuttersconformingto IS:2202(PartI) decorative type, core of block board ….shutter. 30mmthickincludingISImarked Stainless Steel butt hinges with necessary screws. |
| 452 | 3005856, 11.37.1, Kota stone slabs inrisers of steps, skirting, dado and pillars laid on 12 mm (average) ...shadeoftheslabs,including rubbing and polishing complete. 10-12 mm thick |
| 453 | 3005872, 11.46, Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. |
| 454 | 3005916, 11.76.1, Providing and laying vitrified floor tiles (without solublesalt)orprinted(withsolublesalt)Nano polished(Glossy finish)in different .....including groutingthejointswith white cement and matching pigments etc. complete Plain ivory light shade Size 600X600mm thickness 9-10mm |
| 455 | 3005918, 11.77.1, Providing and laying vitrified floor tiles (without solublesalt)orprinted(withsolublesalt)Nano polished(Glossy finish)in differentsizeswith water absorption... 1st quality/premiumqualityinskirting laid on 12mm thick... and matching pigments etc. complete Plain ivory light shade Size 600X600mm thickness 9-10mm |
| 456 | 3007210, 18.28, Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 457 | 3005665, 10.2, StructuralsteelworkusingM.S.flats, angles,channels I-section,H-sectionetc. riveted, bolted or welded in built up sections,trussesandframedwork, including cutting,hoisting,fixingin positionand applyinga primingcoatof approved steel primer all complete. |
| 458 | 3008184, 5.1.1.1, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary short point. (Using modular accessories) |
| 459 | 3008185, 5.1.1.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary medium point. (Using modular accessories) |
| 460 | 3008186, 5.1.1.3, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary long point. (Using modular accessories) |
| 461 | 3008191, 5.1.3.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- 3 Pin 6 Amp socket outlet on separate board Medium point. (Using modular accessories) |
| 462 | 3008194, 5.1.4.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Call bell/buzzer points Medium point. (Using modular accessories) |
| 463 | 3008199, 5.2, Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside casing & capping with required materials as per specification on same board. .(Using modular accessories) |
| 464 | 3008180, 5.3.1, Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping of ISI marked suitable size etc. as required as per specification 2x2.5 Sq.mm ( Using flush type normal accessories) |
| 465 | 3008274, 10.1.1.2, Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :- On separate board Medium point. (Using modular accessories) |
| 466 | 3008275, 10.1.1.3, Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :- On separate board Long point. (Using modular accessories) |
| 467 | 3009107, 27.8.1.2, Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of \"C\" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single pole MCB SP 6Amp to 32Amp 10kA rating |
| 468 | 3009249, 27.23.1.1, Supply & fixing of approved make accepted standard sheet steel enclosure (dust protected) duly powder coated paint neutral bar suitable for MCB/RCBOs/MCCB of capacity as required etc. complete as per specification (exclusive of M.C.B./ MCCB/RCBOs) For MCB SP enclosure |
| 469 | 3009366, 29.25.2, Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board 100 Watt (2 module) |
| 470 | 3008368, 18.3.1, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-1 Or 2 Module PVC box |
| 471 | 3008369, 18.3.2, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-3 Module PVC box |
| 472 | 3008370, 18.3.3, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-4 Module PVC box |
| 473 | 3008371, 18.3.4, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-6 Module PVC box |
| 474 | 3008372, 18.3.5, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-8/9 Module PVC box |
| 475 | 3008373, 18.3.6, Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-12 Module PVC box |
| 476 | 3007524 ,22.14.1,Grading roof for receiving water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) |
| 477 | 3006376 ,14.65,Providing & casting & Repairing of excessively damaged memberswith micro-concrete at all levels with all leads & lift or as directed including formwork, centering, scaffolding, and mixing, laying, levelling, and finishing including curing etc. complete (excluding steel reinforcement |
| 478 | 3006415 ,14.80.1,Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: easurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2)-12 mm average thickness |
| 479 | 3007534 ,22.22,Water proofing treatment over Roof, Wall, Chajjas,, Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of(i) Surface preparation roughening of surface, opening cracks in ‘V’ groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely.(ii) Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80%-chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2ndcoat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow thecoating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per anufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). (iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hight build elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs. minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air cure for 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area.(iv) The treated area should be cure with water for 48 hrs. by flooding the surface.(v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee) |
| 480 | 3007542 ,22.3,Providing & applying crack fill paste for crack filling up to 5 mm cracks.Widen the crack by putty knife in V/U shape & apply 1st priming coat of crack fill paste diluted with water in 1:1 proportion over the crack by brush. |
| 481 | 1000557, NOSR Payment of fixed additional charges for Mobilization of men, materials, T&P etc. due to change in location of work from one substation/premises to another substation/premises after 1st sub order for each separate sub-order (s) under the scope of same contract of civil works shall be payable as per following conditions: -(i)Applicable only after 1st sub work order and only on change in work location from one substation/premises to another substation or any other MPPTCL’s premises situated at a distance of more than 3.00 Kms. for execution of work under the same main contract. (Nearest motorable road distance shall be considered for this purpose)(ii) The distance as mentioned in point no. – (i) shall be considered from the nearest current location of ongoing work (where the work shall be in progress by the contractor at the time of placing new sub-order irrespective of scheduled completion period given for that work) under the scope of same contract. (iii) Not applicable for the balance work (when the sub order of any civil work is placed in two or more parts) of dusting, metaling etc. on the same feeder bay work for which the work of foundation etc. has been executed previously under the scope of same contract.(iv)The rates are inclusive of cost of transportation of labour, material, T&P etc. and cost of all respective works in all respect up to any distance in the area of jurisdiction of main work order for the contract and also in nearby areas as per necessity i/c all applicable taxes (except GST) etc. all complete, as per terms and conditions of order and as per direction of Engineer – In – Charge.(Base Rate: - Rs. 10,000/- per shifting) Note:- This payment of fixed additional charges for changing of work location shall be payable only when work will be executed in accordance with location wise priority fixed by the Engineer-In-Charge (if any) and only on successful completion of work in all respect as per scope of work in the sub-order for which said additional charges are to be payable. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy