Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-05-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 06-05-2025 |
| 2 | 24-04-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-05-2025 |
| 3 | 12-04-2025 | CORIGENDUM TO BOQ | BOQ | 24-04-2025 |
| Sl. No. | Item Description |
| 1 | M&L for preparation of old decorated surfaces of wall by scrubbing down with steel wire brushing scrapping down smoke soot, moulds moss and fluorescent salts and trading oil and greasing spots and applying one coat of white wash, complete all as specified and directed. |
| 2 | All as per item No 1.00 here-in- before butone coat of white wash on ceiling, soffits of slabs, chajj etc, complete all as specified and directed. |
| 3 | All as per item No 1.00 here-in- before butapplying one coat of oil bound distemper on wall, complete all as specified and directed. |
| 4 | All as per item No 1.00 here-in- before but complete removal of existing treatment on old surfaces of wall and applying two coats of oil bound distemper on wall, complete all as specified and directed. |
| 5 | All as per item No 1.00 here-in- before butapplying one coat of cement base paint on wall/chajja, complete all as specified and directed. |
| 6 | All as per item No 1.00 here-in- before but complete removal of existing treatment on old surfaces of wall and applying two coats of cement base paint on wall/chajja, complete all as specified and directed. |
| 7 | M&L for preparation of old painted surfaces of wood or wood based material and applying one coat of synthetic enamel paint on surface of any description over 10cm width or girth, complete all as specified and directed. |
| 8 | M&L for complete removal of existing treatment of old painted surfaces of wood or wood based material and applying two coats of synthetic enamel paint on surface of any description over 10cm width or girth, complete all as specified and directed. |
| 9 | M&L for preparation of old painted steel or iron surfaces and applying one coat of synthetic enamel paint on surface of any description over 10cm width or girth, complete all as specified and directed. |
| 10 | M&L for complete removal of existing treatment of old painted steel or iron surfaces and applying two coats of synthetic enamel paint on surface of any description over 10cm width or girth, complete all as specified and directed. |
| 11 | Demolition and breaking up 100mm dia drain pipes (salt glazed ware, AC or reinforced concrete set in cement mortar, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m as directed. |
| 12 | M&L for brick work with sub class \"B\" bricks old size, straight or curved on plan exc 6 mtr mean radius built in CM (1:6), complete all as specified and directed. |
| 13 | M&L for brick work with sub class \"B\" bricks, old size, burnt clay bricks, straight or curved on plan, any radius, built in CM (1:4) in half brick thick, complete all as specified and directed. |
| 14 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed. |
| 15 | M & L for rendering 15mm thick in two coats (10mm under layer + 5mm top layer) on fair faces of brick work or concrete surfaces of wall in CM (1:4),mixed with integral water proofing compound on top layer as per manufacturer\"s instructions and finished the surface even and fair without using extra cement, complete all as specified and directed. (Note : WPC shall be measured and paid separately) |
| 16 | Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification, complete all as directed. |
| 17 | M&L 15mm thick rendering in CM (1: 6) on fair faces of brick work or concrete surfaces finished surfaces even and smooth without using extra cement, complete all as specified and directed. |
| 18 | M&L 10mm thick rendering in CM (1:3) as in ceiling, chajja, soffits etc, finished surfaces fair and even, complete all as specified and directed. |
| 19 | M&L for rendering 5mm thickin CM (1:3) on fair faces ceiling surfaces, rendering finished even and smooth (without using extra cement), complete all as specified and directed. |
| 20 | M & L for rendering 15mm thick on brick/concrete surfaces in CM (1:3),mixed with integral water proofing compound as per manufacturer\"s instructions and finished the surface even and fair without using extra cement including preparation and cleaning the surfaces using wire brush and washing down with water to remove dust etc. and brushing with neat cement slurry @ 0.5 kg/sqm with acrylic based polymer modified cementitous (pidifine 2K), complete all as specified and directed. ( Note : WPC shall be measured and paid separately) |
| 21 | M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistance primer, complete all as specified and directed. |
| 22 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed. |
| 23 | M&L for complete removal of existing treatment of wall / ceiling etc surfaces and applying two coats of oil bound distemper over and including a coat of 1.5mm to 2mm thick wall care putty and rubbing with sand paper to obtain smooth & plain surface, complete all as specified and as directed. |
| 24 | M&L for preparing newly plastered surfaces of walls etc and applying two coats of distemper oil emulsion over a coat of alkali resitant primer over and including a coat of 1.5mm to 2mm thick wall care putty and rubbing with sand paper to obtain smooth & plain surface, complete all as specified and directed. |
| 25 | M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and directed. |
| 26 | M & L for preparing old decorated surface of walls and applying one coat of 100% acrylic weather proof exterior emulsion paint of approved colour and shade, complete all as specified and directed. |
| 27 | M & L for preparation of newly plastered wall surface and applying two coats of oil bound distemper over a coat of alkali resistance primer, complete all as specified and directed. |
| 28 | Resecuring or easing and adjusting without taking down shutters of any description n. exc. 1 Sqm each, complete all as specified and directed.h |
| 29 | Resecuring or easing and adjusting without taking down Shutters of any descriptionexc. 1 Sqm and n. exc. 2 Sqm each, complete all as specified and directed. |
| 30 | Taking down shutter of any description exc 1 & n.exc 2 Sqm each and refixing in same opening, complete all as specified and directed. |
| 31 | Takiing down chowkat with shutter without taking off shutter from the frame n.exc 1.5 Sqm each, complete all as specified and directed. |
| 32 | Takiing down chowkat with shutter without taking off shutter from the frame exc 1.5 Sqm n.exc 4 Sqm each, complete all as specified and directed. |
| 33 | S & F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheet, complete all as specified and directed. |
| 34 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side prelam PVC sheet used instead of Plain colour PVC sheet. Stile and rails feathered at edges for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of both side Prelam PVC sheet used instead of Plain colour PVC sheet. to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable Prelam PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and directed. |
| 35 | S&F 150mm long aluminium anodised, barrel tower bolt of extruded section, complete all as specified and directed. |
| 36 | S&F 100mm long aluminium anodised, barrel tower bolt of extruded section, complete all as specified and directed. |
| 37 | S&F 150mm long extruded aluminium alloy handle, cast type, anodised, complete all as specified and directed. |
| 38 | S&F butt hinges of size 100mm, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type C-21, complete all as specified and directed. |
| 39 | S&F in repair 150mm long aluminum anodized barred tower bolts of extruded section, complete all as specified and directed. |
| 40 | S&F in repair 150mm long aluminium handle, cast type anodised, complete all as specified and directed. |
| 41 | S&Fin repair 200mm long aluminum anodized barred tower bolts of extruded section, complete all as specified and directed. |
| 42 | S&F 100mm size MS butt hinge, medium weight, cold rolled mild steel, complete all as specified and directed. |
| 43 | S&F butt hinges of size 100mm, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type C-21, complete all as specified and directed. |
| 44 | S&F butt hinges of size 75mm, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type C-21, complete all as specified and directed. |
| 45 | S&F 250mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed. |
| 46 | Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins / spring clips and providing new pins / spring clips, complete all as specified and directed. |
| 47 | S&F 3mm thickplain sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm. in each pane, complete all as specified and directed. |
| 48 | S&F 5.5mm thickplain sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm. in each pane, complete all as specified and directed. |
| 49 | S&F 3mm thick sheet glass, frostedon one side, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane, complete all as specified and directed. |
| 50 | S&F in repair galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple in repair including wooden beads, complete all as specified and directed. |
| 51 | S&F galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple, complete all as specified and directed. |
| 52 | S&F 75mm aluminium anodised hasp and staple, safety type and fixed with screws, complete all as specified and directed. |
| 53 | S&F in repair 20mm dia curtain rod, mild steel, chromium plated, decorative type including CP brackets and other accessories, complete all as specified and directed. |
| 54 | Dismantling of floor, hearth or wall tiles including cement mortar bedding ( but not backing) and remvoing rubbish off the premishes, complete all as specified and directed. |
| 55 | M&L for joint free non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement of match the surfaces over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed. |
| 56 | M&L for vitrified ceramic coloured tiles 10mm thick (square/rectangular) vertical surface skirting/dado area, of each tile not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement of match the surfaces over and including 10mm thick screed bed in CM (1:6), complete all as specified and directed. |
| 57 | M&L glazed ceramic coloured tiles in vertical surface 350x 250x 7mm/450x 300x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering back coat in CM (1:4), complete all as specified and directed. |
| 58 | M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like over and including 15mm thick rendering in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including dismantling existing one, complete all as specified and directed. |
| 59 | Taking down 15mm bore steel water tubing and connection from wall /ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed. |
| 60 | Taking down 15mm bore steel water tubing and connection from wall /ceiling in concealed position including cleaning for re-fixing or removing from site of work, complete all as specified and directed. |
| 61 | S&F steel water tubing and connection medium grade 15mm bore with all fitting fixed to wall or in ceiling with and including \"J\" hook, complete all as specified and directed.. |
| 62 | S&F steel water tubing and connection, medium grade, 15mm bore with all fitting fixedconcealed to wall or in ceiling complete and making good surfaces with CM (1:3), complete all as specified and directed. |
| 63 | Re-fixing old steel tubing and connection, 15mm bore, in new or old position with new fittings, complete on wall/ceiling, complete all as specified and directed.(Note : Serviceable steel tube obtained from taking down shall be re-used) |
| 64 | Taking down 20mm bore steel water tubing and connection from wall /ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed. |
| 65 | S&F steel water tubing and connection, medium grade, 20mm bore with all fitting fixed to wall or in ceiling with and including \"J\" hook, complete all as specified and directed. |
| 66 | Re-fixing old steel tubing and connection 20mm bore in new or old position with new fittings, complete on wall/ceiling, complete all as specified and directed.(Note : Serviceable steel tube obtained from taking down shall be re-used) |
| 67 | S&F in repair 15mm bore bib taps, cast copper alloy, chromium plated, long body, fancy type, with capstan head, screwed down, screwed for iron pipe, compelete all as specified and directed. |
| 68 | S&F in repair 15mm bore bib taps, chromium plated, two way, with capstan head, screwed down, screwed for iron pipe, compelete all as specified and directed. |
| 69 | S&F in repair 15mm bore angular stop cock, chromium plated, screwed down, high presure with crutch or butterfly handle screwed both ends for iron pipe or union, complete all as specified and directed. |
| 70 | S&F in repair brass CP tubular towel rail, 20mm dia, D type, 60cm long between flanges, compelete all as specified and directed. |
| 71 | S&F in repair 15mm bore, fancy type, chromium plated, stop valves, with long shank and cup concealed type, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed bothends for iron pipe or union, complete all as specified and directed. |
| 72 | S&F in repair CP pillar tap, 15mm bore, capstan head, screweddown high pressure with or without lettered “hot’ or “ cold” with long screwed shanks and fly nuts screwed for iron pipe, complete all as specified and directed. |
| 73 | S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.00 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and directed. |
| 74 | S&F in repair swivel shower rose 125mm size, brass, chromium plated, with long head arm for fixing with 15mm bore pipe, complete all as specified and directed. |
| 75 | S&F in repair of 32mm size PVC flexible waste pipe forwash hand basin, 800mm long, complete all as specified and directed. |
| 76 | S&F in repair of 40mm size PVC flexible type for sink, 800mm long, complete all as specified and directed. |
| 77 | S&F in repair 10 ltrs capacity low level valve less PVC syphonic action type flushing cistern white with in-let, ball valve, float and handle, 32mm dia flush pipe polythelene or PVC, complete all as specified and directed. |
| 78 | Fixing only in repairs low level flushing cistern and connections to pipes and fixing of chain and pull, or lever, if any, complete all as specified and directed. |
| 79 | S & F in repair, 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends, complete all as specified and directed. |
| 80 | S&F in repair CP grating 100mm dia with or without waste hole, fixed to floor trap, complete all as specified and directed. |
| 81 | S&F in repair 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, complete all as specified and directed. |
| 82 | S&F in repair 15mm bore bib tap standard of PTMT any colourhigh pressure screwed for iron pipe & fixed (minimum weight 90gms), complete all as specified and directed. |
| 83 | S & F in repairs, 15mm bore pillar taps, of PTMT any colour high pressure screwed iron for iron pipes and fixed (minimum weight 110 gms), complete all as specified and directed. |
| 84 | S & F in repairs, 15 mm bore,stop valves standard of PTMT any colour high pressure screwed for iron pipes and fixed (minimum weight 90 gms), complete all as specified and directed. |
| 85 | S & F in repairs, 15mm bore,angle stop valves of PTMT any colour high pressure screwed for iron pipes and fixed (minimum weight 90 gms), complete all as specified and directed. |
| 86 | S & F 4mm thick non asbestos fibre reinforced designer ceiling board (610mmx610mm) with hot drip heavy duty suspended ceiling grid system T-2430with GI frame work for seamless ceiling comprising of GI perimeter channel, unequal flanges and web etc of suitable size suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section including Hangers 6 mm dia GI fixed to roof by means of ceilling cleats made out of GI flat per manufacturers instructions including dismantling of old unserviceable ceiling board any thickness including cover fillets, complete all as specified and directed. |
| 87 | M & L for preparation of newly plastered surfaces of walls and applying two coats of 100% acrylic weather proof exterior emulsion paint of approved colour and shade over a coat of exterior emulsion primer alkali & fungal resisatance (camouflage pattern) as per manufacturere\"s instructions, complete all as specified and directed. |
| 88 | M&L for new plastering of surfaces of wall by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7\"- 9\"including cleaning, watering etc to make the surface free form dust loose paint etc, filling cracks up to 5 mm with creak fill past (elastomeric past, as per manufacturer of paint) and applying two coats of weather proof exterior emulsion paint over and including priming coat of exterior primer with fully automatic airless spray machine with flow speed of min 1 ltr mimetic having pressure of 3300 PSI, by allowing 6-8 hrs to dry the surface for painting of subsequent coats, complete all as specified and directed. (Note:- Cost for necessary scafolding, safety & protective measures, insurance & paper marking tape etc shall deemed to be included in the unit quoted rate). |
| 89 | M&L for complete removal of existing treatment of old painted surfaces of wall by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7\"- 9\"including cleaning, watering etc to make the surface free form dust loose paint etc, filling cracks up to 5 mm with creak fill past (elastomeric past, as per manufacturer of paint) and applying two coats of weather proof exterior emulsion paint over and including priming coat of exterior primer with fully automatic airless spray machine with flow speed of min 1 ltr mimetic having pressure of 3300 PSI, by allowing 6-8 hrs to dry the surface for painting of subsequent coats, complete all as specified and directed. (Note:- Cost for necessary scafolding, safety & protective measures, insurance & paper marking tape etc shall deemed to be included in the unit quoted rate). |
| 90 | S&F 16mm dia CPVC pipes SDR-11 & plain CPVC, SDR 11, fittings complete on wall/floor/roof terece with necessary saddle/clamps includingall necessay fittings, like elbow, tee, socket, reducer, bushings, end caps, End plugs, etc and with CPVC solvents cement, complete all as specified and directed. |
| 91 | S&F 20mm dia CPVC pipes SDR-11 & plain CPVC, SDR 11, fittings complete on wall/floor/roof terece with necessary saddle/clamps includingall necessay fittings, like elbow, tee, socket, reducer, bushings, end caps, End plugs, etc and with CPVC solvents cement, complete all as specified and directed. |
| 92 | Cutting chases, pinning in, making good to facings in stone concrete wall / blocks / slab where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting n.exc. 10cm girth, complete all as specified and directed. |
| 93 | S&F in repair 20mm bore gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipes, complete all as specified and directed. |
| 94 | S&F rotational moulded polyethylene water storage tanks, triple layered, (cylindrical vertical with closed top) ISI marked, confirming to IS 12701-1989, hoisted and fixed in position all as specified in SSR Part I (1000 ltr capacity) including 20mm Nipple suitable for HDPE water tank and 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed to 20mm bore pipe inculding dismantling of old unserviceable water tank of any capacity, complete all as specified and directed. |
| 95 | Cleaning and removing all scale and dirt etc, fromtanks of capacity (exc. 500 & n. exc. 1000 ltr), and from mouths of circulating pipes etc using edible bleaching powder/liquid and washing with water, writing the item \"Tank Cleaned on ____\" indicating the date, month & year of cleaning on external surface of tank walls with synthetic enamel paint, complete all as specified and directed. |
| 96 | S&F in repair 600mm x 450mm bevelled edge mirror made of selected quality sheet glass not less than 5.5mm thick, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 97 | S&F in repair vitreous china ware wash hand basin white, flat back, size 580 x 450mm size(flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand including pedestal, complete all as specified. |
| 98 | S & F in repair vitreous china urinal, bowl type flat back of size 465 x 355 x 265mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including urinal spreader, providing and fixing plugs, bedding urinal against wall in CM (1:2), securing urinal to plug with and including 60mm long brass screws, pointing around urinal back, complete all as specified and directed. |
| 99 | S&F in repair vitreous china EWC (padestal pattern) white including seat and cover, flushing cistern, flush pipe, \"P\" or \"S\" trap and including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc including making good distrubed surfaces, complete all as specified and as directed. |
| 100 | S&F in repair vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc, complete all as specified and as directed. |
| 101 | S&F in repair towel rail, 600mm long PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 190gms), complete all as specified and directed |
| 102 | S&F in repair towel ring of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 90gms), complete all as specified and directed |
| 103 | S&F shelf of PTMT 450mm size, fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms), complete all as specified and directed |
| 104 | S&F in repair 140mm grating round of PTMT (minimum weight 50gms), complete all as specified and directed. |
| 105 | S&F in repair 100mm dia cast iron floor trap / Nahani trap with grating including jointing to waste pipe fixed in PCC (1:2:4), type B-1, compelete all as specified and directed. |
| 106 | S & F 110mm bore PVC SWR pipe, single socketed, in any length with rubber ring joint, fixed to wall with and including clamps, complete all as specified and directed. |
| 107 | S&Fin repair of 110mm bore, PVC (SWR) bends of any radius, complete all as specified and directed. |
| 108 | M&L for point wiring with multistranded copper conductor cable,PVC insulated and unsheathed (FRLSH) size 1.5 sqmm drawn in and includingPVC casing and caping with fixing accessories, to befixed on wooden gutties or plastic rawal plug, for one light /fan point controlled by one switchwith pressed steel concealed terminal boxes coveredwith 3 mm thick laminated sheet / modular plate incl continous earth wire of PVC insulated unsheathed, FRLSH multi stranded copper conductor cablesize 1.5 Sqmm for earth wire connected to common earth dolly for one light/fanpoint controlled by one, one way switch single pole including taking down old unserviceable point wiring of any type, size and description including making good distrubed surfaces to match the existing surface, complete all as specified and directed. |
| 109 | All as per item No 108.00 here-in before but for one 3 pin 5 Amps socket point on the same board, complete all as specified and directed. |
| 110 | All as per item No 108.00 here-in before but for one 3 pin 5 Amps socket point on independent board, complete all as specified and directed. |
| 111 | All as per item No 108.00 here-in before but for one bell/buzzer point controlled by one push button on the same board with other switches or independent, complete all as specified and directed. |
| 112 | All as per item No 108.00 here-in before but with 4.0 Sqmm PVC insulated unsheathed multi stranded copper conductor cable FRLSH type for one 15 Amp 3 pin / 5 pin socket outlet point including PVC insulated 4.0 Sqmm FRLSHtype copper multi stranded conductor as earth wire, complete all as specified and directed. |
| 113 | M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLSH type multi stranded copper conductor, single core drawn in and including concealed, rigid PVC conduit (ISI marked) not less than 20mm dia, heavy duty, including all conduit accessories with and including concealed pressed steel terminal box of suitable size factory made with top cover of ISI marked plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLSH type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site & including cutting chases & making good disturbed surface & applying finishes to match existing surface etc. for one light/fan point controlled by one, one way switch single pole including taking down old unserviceable point wiring of any type, size and description, complete all as specified and directed. |
| 114 | All as per item No 113.00 here-in before but for 3 pin 5 Amp socket point on same board, complete all as specified and directed. |
| 115 | All as per item No 113.00 here-in before but for 3 pin 5 Amp socket point on independent board, complete all as specified and directed. |
| 116 | All as per ser item No. 113.00 here-in before but for one bell/buzzer point controlled by one push button on the same board with other switches or independent, complete all as specified and directed. |
| 117 | All as per item No 113.00 here-in before but with 4.0 Sqmm PVC insulated unsheathed multi stranded copper conductor cable FRLSH type for one 15 Amp 3 pin/5 pin socket outlet point including PVC insulated 4.0 Sqmm FRLSHtype copper multi stranded conductor as earth wire, complete all as specified and directed. |
| 118 | S&F switch piano flush button single pole one way 6 Amps 230 volts, complete all as specified and directed. |
| 119 | S&F socket outlet 2 in 1, 3 pin 6 Amp flush type, complete all as specified and directed. |
| 120 | S&F switch and socket combination2 in 1, 6 Ampflush type, complete all as specified and directed. |
| 121 | S&F switch and socket combination 3 pin, 16 Amp, flush type, complete all as specified and directed. |
| 122 | S&F ceiling rose surface PVC / Polycarbonate 50mm dia 3 terminals including PVC mounting block white/ivory finish, complete all as specified and directed. |
| 123 | S&F lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. |
| 124 | S&F stepped type electronicfan regulator flush typeAC 230 volt suitable for any type of ceiling fan all as specified and directed. |
| 125 | S&F bell push, flush type 5 Amp, complete all as specified and directed. |
| 126 | S&F bell electric, heavy duty, ding dong type 230 volts single pole, complete all as specified and directed. |
| 127 | Supply and draw sub main wiring in repairs of two run 4.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduitheavy duty and accessories of not less than 25mm size ISI marked including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of4.0 sqmm single core PVC insulated unsheathed copper earth continuityincluding making good disturbed surface including taking down existing sub-main wiring, any numbers of wire and any size, complete all as specified and directed.(Note: Two runs of single core cable with one run of earth continuity conductor including PVC conduit & accessories shall be measured and paid as one length.) |
| 128 | All as per item No 127.00 here-in before but drawn through and including PVC casing/caping, surface type, complete all as specified and directed. |
| 129 | S&F sheet metal enclosure for double door MCB DBs, phosphatised, powder coated, Single Pole & Neutral (SPN), suitable for 4 way, 240 volts,IP 43 & IK 09 fixed on wall with din rail, neutral and earth bar, fixed in proper position, complete all as specified and directed. |
| 130 | S&Fsheet metal enclosure for double door MCB DBs, phosphatised, powder coated, Single Pole & Neutral (SPN), suitable for 8 way, 240 volts,IP 43 & IK 09 fixed on wall with din rail, neutral and earth bar, fixed in proper position, complete all as specified and directed. |
| 131 | S&F sheet metal enclosure for double door MCB DBs, phosphatised, powder coated, Triple Pole & Neutral (TPN), suitable for 4way, 415 volts,IP 43 & IK 09 with metal door fixed on wall with din rail, neutral and earth bar, fixed in proper position, complete all as specified and directed. |
| 132 | S&F MCB Triple Pole and Neutral (TPN) of capacity 40 to 63 Amps, 415 Volts, breaking capacity 10 KA, ‘C’ series, fixedin proper position, complete all as specified and directed. |
| 133 | S&F MCB Single Pole and Neutral (SPN) of capacity 40 to 63 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixedin proper position, complete all as specified and directed. |
| 134 | S&F MCB Single Pole (SP) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 1 0 KA, ‘C’ series, fixedin proper position, complete all as specified and directed. |
| 135 | S & F wall mounted inverter LED batten light fitting 1 x 20 Watt, 4 feet long, 220V, ACwith driver and backup time upto 4 hours including 20 W LED 6500K lamp, protection class not less than IP 20, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking down old unserviceable light fittings, complete all as specified and directed. |
| 136 | S&F in replacement inverter LED bulb 12 Watt 6500K and backup time upto 4 hours, protection class not less than IP 20, insulated body, suitable for B-22 base, complete all as specified and directed. |
| 137 | S&F surface/suspended LED lightbox type decorative fittings 1 x 40 Watt, 4 feet long, 220V, ACwith driver including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking down old unserviceable light fittings, complete all as specified and directed.(Make : Crompton Cat No. CCP-133-40-HCL-SL-BT-DWH or Bajaj Cat No. BPCS40WLED WH 4F or Philips Cat No. SP095VLED40S865W7L120 PSU WH S1) |
| 138 | S&F surface/suspended/recessed mounted 600mm x 600mm LED panel light type decorative fittings 42 watt, 220 V, AC, including LED tube lightconnecting up with three core flexible copper conductor cases of suitable size, complete all as specified and directed.(Make : Bajaj Cat No. BZRSQL 42L LED GXWH or Crompton Cat No. LCTLRNE-42-FO-CDL or Philips Cat No. RC380B LED42S-6500 G6L60W60 PSU OD S1) |
| 139 | S&F surface/suspended/recessed mounted 1200mm x 300mm LED panel light type decorative fittings 30 watt, 220 V, AC, including LED tube lightconnecting up with three core flexible copper conductor cases of suitable size, complete all as specified and directed.(Make : Philips Cat No. RC380B LED30W-6500 G5L12W3 PSU OD or Havells Cat No. PLUTONE04X1PLR30WLED840S or equivalent model of Crompton/Bajaj) |
| 140 | S&F recessed mounted LED panel light round type decorative fittings 12 watt, 220 V AC, including electronic driver and connecting up with three core flexible copper conductor cases of suitable size, complete all as specified and directed.(Make : Crompton Cat No. CDR-205-12-57-SL-NWH or Orient electric Cat No. LDRVP-012-C-FC or Philips Cat No. DN496LED12S-6500 PSU WH or Bajaj Cat No. BRDCSL15W LED-WH or Havells Cat No. INTEGRANEODLR12WLED 857S) |
| 141 | S&F recessed mounted LED panel light round type decorative fittings 15 watt, 220 V AC, including electronic driver and connecting up with three core flexible copper conductor cases of suitable size, complete all as specified and directed.(Make : Philips Cat No. DN496LED15S-6500 PSU WH or Crompton Cat No. CDR-205-15-57-SL-NWH or Havells Cat No. INTEGRANEODLR15WLED 857S) |
| 142 | S&F recessed mounted LED wall washer COB type decorative fittings 25 watt, 220 V, AC, including electronic driver and connecting up with three core flexible copper conductor cases of suitable size, complete all as specified and directed.(Make : Philips Cat No. RS 261B LED 25 S/865 PSU VWB WH or Havells Cat No. UNECOSNOOTDLR 25WLED 830S36 or equivalent model of Bajaj/Crompton) |
| 143 | S&F in replacement recessed mounted LED light fittings 36 watt (size 4\" x1\"), white/warm white colour (4500 K to 6500 K) ultra modern LED edgelit luminaire suitable for armstrong/grip/POP ceiling complete with seperate electronic driver and high brightess LED including LED lamp and connecting up with three core 2.5 Sqmm upto nearest point, complete all as specified and directed.(Make : Philips Cat No. RC380BLED36S-6500 G5L12W3 PSU OD or Orient Cat No LT SAQ-36-C-1 x 4-FC or Bajaj Cat No. BZSSLL 36L LED WHI) |
| 144 | S&F in replacement LED bollard light 10 watt with soft 360 degree light distribution, IP-65/66, inverted pyramid tripod type with PCC & fixing all ecessary arrangement, complete all as specified and directed.(Make : Crompton Cat No. LBLSN-10-CDL or Orient electric Cat No. LLSBL-10-W or Philips Cat No. BPC100 LED CW/NW/WW10W PSU GR L750mm) |
| 145 | Taking down existing light fitting carefully a side and re-fixing after same, complete all as specified and directed. |
| 146 | M&L for cutting chases, pinning in making good to facing in stone concrete wall/blocks/slab, where required and pointing in CM (1:3) to ends to facings where required and pointing inCM (1:3) to ends or edges of landings, steps, cills , sunshades,shelves, lintesl etc and cutting chases for concealed water tubing or conceales conduit wiring etc and making good cutting not exc. 10cm girth in brick walls, complete all as specified and directed. |
| 147 | M&L for modular switches 1 way 10 Amp, 1 module, absolute white colour and making good to the distrubed srfaces including taking down existing switch, complete all as specified and directed. |
| 148 | M&L for modular switches 1 way 20 Amp, 1 module, absolute white colour and making good to the distrubed srfaces including taking down existing switch, complete all as specified and directed. |
| 149 | M&L for modular bell push 6 Amp, 1 module, absolute white colour and making good to the distrubed srfaces including taking down existing switch, complete all as specified and directed. |
| 150 | M&L for modular socket 6 Amp/10 Amp, 2/3 pin, combined with safety shutter, 2 module, absolute white colour and making good to the distrubed srfaces including taking down existing switch, complete all as specified and directed. |
| 151 | M&L for modular universal socket 6 Amp/16 Amp, 2/3 pin, combined with safety shutter, 2 module, absolute white colour and making good to the distrubed srfaces including taking down existing switch, complete all as specified and directed. |
| 152 | M&L for modular stepped type electronic fan regulator/dimmer 120 w, 5 step, 2 module, AC 230 volt, absolute white colour and making good to the distrubed srfaces including taking down existing switch, complete all as specified and directed. |
| 153 | M&L for AC motor starter switch 20 Amp, 2 module, AC 230 voltage 160-240 V, 50-60 Hz, absolute white colour and making good to the distrubed srfaces including taking down existing switch, complete all as specified and directed. |
| 154 | M & L modular cover plate with inner frame 3 module, snow white colour including taking down existing cover plate carefully and making good to the disturbed surfaces by applying wall putty around the cover plate and fixing of all accessoreis as per site requirement, complete all as specified and directed. |
| 155 | M & L modular cover plate with inner frame 4 module, snow white colour including taking down existing cover plate carefully and making good to the disturbed surfaces by applying wall putty around the cover plate and fixing of all accessoreis as per site requirement, complete all as specified and directed. |
| 156 | M & L modular cover plate with inner frame 6 module, snow white colour including taking down existing cover plate carefully and making good to the disturbed surfaces by applying wall putty around the cover plate and fixing of all accessoreis as per site requirement, complete all as specified and directed. |
| 157 | M & L modular cover plate with inner frame 8 module, snow white colour including taking down existing cover plate carefully and making good to the disturbed surfaces by applying wall putty around the cover plate and fixing of all accessoreis as per site requirement, complete all as specified and directed. |
| 158 | M & L modular cover plate with inner frame 12 module, snow white colour including taking down existing cover plate carefully and making good to the disturbed surfaces by applying wall putty around the cover plate and fixing of all accessoreis as per site requirement, complete all as specified and directed. |
| 159 | Note: An amount of Rs.34,507.00 on account of Credit Schedule for schedule \"A\" part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. |
| 160 | Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy