| 1 | SCHEDULE \"A\" PART-I: B/R WORKS |
| 2 | Dismantling floor, hearth or wall tiling incuilding cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises. |
| 3 | M&L for light shade Virified Ceramic coloured tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement lurry and pointed in white or coloured cement to match and laid over 15 mm thk cement screed bed in cm 1:6 for laying floor finishes. |
| 4 | M&L for light shade Virified Ceramic coloured tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement lurry and pointed in white or coloured cement to match and laid over 10 mm thk cement rendering in cm 1:4 for laying floor finishes. |
| 5 | M&L Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11sqm, in floors etc, set jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cm 1:6 for laying floor finishes. |
| 6 | M&L Non-skid joint free coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36sqm, in floors etc, set jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cm 1:6 for laying floor finishes. |
| 7 | M&L for Glazed ceramic coloured tiles 350x250x7 mm/450x350x7 mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in white or Coloured cement to match &including 10mm thickrenderingin CM (1:4)on fair faces of brickwork or concrete surfaces complete all as specified. |
| 8 | Taking up or down steel tubing of 15 mm dia bore and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 9 | Taking up or down steel tubing of 20 mm dia bore and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 10 | Taking up or down steel tubing of 25 mm dia bore and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 11 | Refixing old steel tubing of 15 mm dia boreand connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed |
| 12 | Refixing old steel tubing of 20 mm dia boreand connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed |
| 13 | Refixing old steel tubing of 25 mm dia boreand connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed |
| 14 | S&F 15 mm dia bore GI steel water Tubes medium galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed |
| 15 | S&F 20 mm dia bore GI steel water Tubes medium galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed |
| 16 | S&F 25 mm dia bore GI steel water Tubes medium galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed |
| 17 | Supplying and laying of 16 mm dia bore of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified. |
| 18 | Supplying and laying of 20 mm dia bore of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified. |
| 19 | Supplying and laying of 25 mm dia bore of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified. |
| 20 | S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs , washers and wastes, incl bedding in cement moartor on to dwarf wall or incl fixing cantilever brackets and connecting union to pipe onerall size990x420 with bowl size of410x330x160mm complete all as specified and as directed |
| 21 | S&F in repairs Vitreous China EWC with P or S Trap including seat cover closed pattern with flat bottom and cover and MS CP hinging device, PVC flush bend pipe incl PVC Flushing Cistern 10 LITRE capacity, Low Level Valve Less, Symphonic Action type, White, with Inlet, Ball Valve, Float and Handle including 32mm dia PVC Flush Pipe, a Pair of Cast Iron Brackets duly Painted/ Erecting Stand including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 including taking down unserviceable Flushing Cistern and connected Items of any description, complete all as specified and as directed. |
| 22 | S&F in repairs Vitreous China half stall urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed |
| 23 | S&F in PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed. |
| 24 | S&F vitreous China clay wash hand basin of size 550x400mm incl pedastal pattern complete all as specified and as directed |
| 25 | S&F in repairs toilet paper holder with flat recessed type stainless steel complete all as specified and directed |
| 26 | S& F in repairs Brass CP tubulartowel rail 20 mm dia , 60 cm long including brackets compelete |
| 27 | S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified . |
| 28 | S&F 20mm bore gun-metal globe or gate valves,with iron wheel head ,screwed both ends for iron pipe and fixed |
| 29 | S&F 25mm bore gun-metal globe or gate valves,with iron wheel head ,screwed both ends for iron pipe and fixed |
| 30 | Supply hoisting and fixing in rotational moulded HDPE water storage tank ,double layer ,ISI marked (cylendrical vertical type with closed top) of capacity 1000 ltrs in position incl float valvehigh pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed incl dismantling of tank all as specified and directed. |
| 31 | Supply hoisting and fixingrotational moulded HDPE water storage tank ,double layer ,ISI marked (cylendrical vertical type with closed top) of capacity 500 ltrs in position incl float valvehigh pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed incl dismantling of tank all as specified and directed. |
| 32 | S&F cutting chases, pinning in concrete block workmaking good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades shelves, lintels etc, and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10cm girth. |
| 33 | S&F in repairs Brass CP angular stop cock fancy type with Capstan heads of make Jaguar/Marc/Parryware |
| 34 | S&F in repairs bevelled edge mirror or selected quality glass, mounted on 6 mm thick AC building board or commericial ply wood and fixed to wooden plugs with CP brass screw and cup washer. |
| 35 | M&L 75mm dia PVC(SWR)floor trap, plain with grating including jointing with solvent cement |
| 36 | M&L for 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints ,laid in trenches or in floors complete |
| 37 | M&L for 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints ,laid in trenches or in floors complete |
| 38 | S&F PVC (SWR) bends 110mm dia complete all as specified and as directed |
| 39 | S&F PVC (SWR) bends 75mm dia complete all as specified and as directed |
| 40 | S&F Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays ,incl bolts and nuts and securing ends of stays to wall or roof. |
| 41 | S&F PVC Connections pipe of 15mm size with PTMT Nuts of length 450mm and fixed, complete all as specified and as directed. |
| 42 | M & L 25 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate as in subfloors finished even and rough without using extra cement complete all as specified and as directed. |
| 43 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 44 | M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even & smooth without using extra cement with WPC (WPC paid separetely) complete all as specified and directed. |
| 45 | M&L 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even & smooth without using extra cement complete all as specified and directed. |
| 46 | M&L 5 mm thick rendering on ceiling surface in cement mortar 1:3 finished even and smooth without using extra cement. |
| 47 | Supply only integral water proofing compound ISI marked. |
| 48 | M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint on wall complete all as specified and as directed. |
| 49 | M&L for preparing old paintedsurfaces and applying one coat of cement based paint on walls. |
| 50 | M&L for preparing newly plastered surface with two coats of oil bound distemper over a coat of primer on ceiling surface. |
| 51 | M&L forpreparing old distempered wall surfaces and applying one coat of oil bound distemper on walls. |
| 52 | M&Lpreparing old distempered ceiling surfaces and applying one coat of oil bound distemper on ceiling. |
| 53 | Material and labour for complete removal of existing treatment from old decorated plastered surfces of wall by Vacuum based sanding machine, removal of nails etc & filing cracks / hole with putty, applying wall care putty upto 1mm thick as required (Multipurpose mixer shall be used for uniform and proper mixing of putty ) and appling two coat of emulsion distemper white or coloured complete all as specified and directed as per manufacturers instruction. |
| 54 | Preparation of New or previously untreated surfaces of cement or plastered surfaces, of any description and girth, not otherwise described and applying 1mm thick wall care putty and primer on wall surface to achieve even and smooth surface and applying two coats of oil bound distemper on walls. |
| 55 | M&L for preparing old decorated plaster surfaces etc and applying one coat of white washon ceilings complete all as specified and directed. |
| 56 | M&L for preparing old plastered surface with one coats of white wash on wall surface. |
| 57 | M&L for preparation of old painted surfaces of wood and wood based materials of any description, not otherwise described and applying one coat of Synthetic enamel paint over 10 cm width or girthcomplete all as specified and directed. |
| 58 | M&L preparation of old painted steel and iron surfaces of any description over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 59 | Complete removal of existing treatment and preparation of old or previously surfacesandapplying a thick layer ofwall care putty and primer on wall surface to achieve even and smooth surface and applying two coats of weather proof acryic emulsion paints, exterior grade (100% acryic) on surfaces of walls. |
| 60 | M&L for preparing old painted surfaces by washing rubbing down and stopping of painted surfaces and applying one coat of weather proof acrylic emulsion paint,exterior grade on surfaces of walls. |
| 61 | Material and labour for preparation of newly plastered surfaces of wall by vacuume based sanding machine, applying wall care putty (Multipurpose mixer shall be used for uniform and proper mixing of putty) and applying two coat of emulsion distemper white or coloured complete all as specified and directed as per manufacturers instruction. |
| 62 | M & L Providing pressure gunitting in CM (1:3) upto 40mm thick averaging 25mm thick for soffits of slabs, beams, columns,chajjas, cantilever slab, fins, stair cases, railing etc complete all as specified and directed including brush bond as per manufacturer instruction and supply and fix welded steel wire fabric of mesh 75x25mm of weight not less then 4.0KG per 1 Sqm fixed to proposed surface for guniting with suitable pins/clamps/welding to the existing reinforcement after preparing old surface and applying polymer modified cementions coating on concrete surface prepared for gunniting using NITTO bond/brush bond of M/S Fosroc Chemicals and equivalent and applying epoxy treatment to exposed surface and making good surface with colour wash/white wash/snowcem painting two coats as specified and as directed |
| 63 | Dismantaling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets |
| 64 | M& L for 6 mm thickExposed metal frame ceiling with calcium silicate board prepainted of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre Hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm longcomplete all as specified |
| 65 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc including removal of debris out side MD land complete all as specified and directed. |
| 66 | M&L brick work with fly ash bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 67 | M&L for RR masonry built in CM 1:6 uncoursed well bonded bedded solidly hearted built inCM 1:6 complete all as specified and directed. |
| 68 | M&L for walling of random rubble masonary uncoursed,well bonded, bedded and soildly hearted built in cement mortar 1:6.but except stone complete all as specified and directed. |
| 69 | Plain Cement Concrete Type C2 1:3:6 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 70 | M&L Plain Cement Concrete Type C1 1:3:6 (using 20 mm graded granite stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded or chamfered complete all as specified and directed. |
| 71 | M&L extra forming fair finish to drain or channel surface n.exc 30cm inner girth in cement concrete with using extra cement complete all as specified and directed. |
| 72 | M&L for rendering 15mm thick on stone masonry surfaces or surfaces other than fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and fair complete as all specified and directed. |
| 73 | Demolition of existing RCC cover slabof any thickness, in any position of manholes, soakage pits, septic tank etc complete all as specified and directed. |
| 74 | M&L for precast cement concrete 1:1.5:3 type A1 using 20mm gradedstone agregate including necessary form work as in manholes cover slab etc, set in cement mortar 1:4 complete all as specified and as directed. (Note :- Re-inforcement shall be measured and paid for separately under respective items of Sch \"A\" here in after) complete all as specified and directed. |
| 75 | Rough finished Square or rectangular Form work to sides of pillars, posts, struts, columns and stanchions complete all as specified and directed. |
| 76 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 77 | M&L Reinforced Cement Concrete1:1.5:3 type A1 (using 20 mm graded granite stone aggregate) in foundations including rafts, footings foundation beams, plinth beams, bases for columns, etc.basement slabs, underreamed piles and mass concrete , complete all as specified and directed.. |
| 78 | M&L Reinforced Cement Concrete1:1.5:3 type A1 (using 20 mm graded granite stone aggregate) in Columns, piers, posts and struts.complete all as specified. |
| 79 | M&L mild steel TMT bars10 mm dia and over,cut to length, bent to shape required including cranking, bending spirally for hooping for columns , hooking ends & binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 80 | M&L for mild steel bars (TMT bars) 5mm dia and overupto and including 10mm dia in stirrups, spacers and binders, complete all as specified and directed. |
| 81 | Demolition of un-reinforced cement concrete/bituminous surface in ground floors and pavings not exceeding 15 cm thickness (Below or above ground level) complete all specified and directed. |
| 82 | M&L for Cement concrete 100mm thicktype B-2 (1:2:4) using 40mm graded stone aggregate as in hard standing and paving etc.finished fair and even all as specified and directed. |
| 83 | M&L for preparation of new of previously untreated surface of any description over 10cm girth or width, not otherwise described and applying two coats of synthetic enamel (ordinary tint) paint over a coat of primer complete all as specified and directed. |
| 84 | M&L for preparation of old painted surfaces of brick, stone, concrete etc and applying one coat of synthetic enamel paint ,surfaces of any description over 10 cm girth or width, not otherwise describedcomplete all specified and directed. |
| 85 | De-siltingof existing Covered Drains/Open Drains of any cross section in any condition( including foul condition) by removing silt, grit,mud,debris, sludge deposits, pebbles, large stones of any shape including bailing out of water by mechanical pump if required and deposited to a distance n exc 1.5 km for smooth flow of water complete all asspecified anddirected. |
| 86 | S & F PVC Coated Chain Link MS Galvanised Fencing Mesh of size 50 mm X 50 mm, 3mm dia wire including minimum 1 mm thick PVC Coating and of weight not less than 4.5 KG / Sq.m including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete including dismantling of existing unserviceable fencing all as specified and directed. |
| 87 | S&F in repairs Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc complete all as specified and directed. |
| 88 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 89 | M&L for Framed work such as grills, gratings, etc.with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders;ramed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gd complete all specified and directed. |
| 90 | Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 91 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid in any mortar complete all as specified and directed. |
| 92 | M&L for30 cm x 30 cm x 22 mm to 25mm thick Chequered cement concrete tilesin flooring, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shadeincluding 15mm thick Cement mortar (1:6) screed bed or bedding layer of mortar for laying floor tiles complete all as specified and directed. |
| 93 | M&L sand filling under floors or in foundation including watering and consolidation complete all as specified and directed. |
| 94 | M&L machine pressed precast concreteinter locking blocks with grey cement and no pigmentany shape and size confirming to IS 15658-2006 of 80 mmm thickness M-40 grade complete all as specified and directed. |
| 95 | M&L for 20mm thick Granite work (table rubbed and polished) in decorative shelves, steps, pillars, jambs, cooking platforms, stages, etc with chemfering of edge and like inn CM 1:4 including pointing in white cement (1:2) using marble dust with mixture of pigment to match with shade of granite including grinding & mirror polishing with and including 15mm thick screed bed or bedding layer in CM(1:6) complete all as specified and directed. |