| Sl. No. | Item Description |
| 1 | Removal existing treatment any type, any thickness and their Roughening surfaces of old concrete floor or concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc., all as specified and as directedfrom 13th Storey to 16th Storey. |
| 2 | Brushing neat cement slurry with 3 Kg of cement per square metre from 13th Storey to 16th Storey all as specified and as directed. |
| 3 | M&L for 25 mm th PCC 1:2:4 type B1 (using 20 mm graded aggregate) mixed with WPC as directed and laid on RCC slab to make surface levelled for proper slope finished even and fair all as specified from 13th Storey to 16th Storey all as specified and as directed. Note: WPC measured and paid separately. |
| 4 | M&L for rendering5 mm thin CM 1:4on concrete srfaces to make surface smooth to receive water proof treatment including mixing WPC as per manufacturing instructionsfrom 13th Storey to 16th Storey all as specified and as directed. Note: WPC measured and paid separately . |
| 5 | Supply only Integral water proofing compound |
| 6 | Supply and laying hyperlas standard 3 Kg/Sqm polymeric water proofing membrane incorporating a centre core of 90 micron thick HMHDPE film including coating the surface with a coat of water based bituminous primer @ 100 gms/sqm followed by a coat of blown bitumen of grade 85/25 or 90/15 @ 1.2 Kg/Sqm each at top and bottom of the membrane followed by a coat of bituminous aluminium primer @ 100 gms/Sqm complete including sealing all joints by thermo fusion with minium 10 cm overlap all as per manufacturer\"s instructions for from 15th Storey to 16th Storey all as specified and as directed. |
| 7 | M&Lfor coolrooftiles of size 300x300, 7mm thick &Solar Reflectance Index (SRI) valuemore than 90 as on roof laid over screed bed/bedding layer of 10 mm thick in CM 1:4, joint Shall be kept as 3mm filled with epoxy grout and masking tape shall be put before putting the epoxy grout, grout shall be througly cleaned immediatlely for from 15th Storey to 16th Storey complete all as specified and as directed.Note: The colour / shade / design of tile shall be approved by GE |
| 8 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness all as specified and as directed. |
| 9 | All as per above item but from 5th Storey to 8th Storey |
| 10 | All as per above item but from 9th Storey to 12th Storey |
| 11 | All as per above item but from 13th Storey to 16th Storey |
| 12 | Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for all as specified and as directed. |
| 13 | All as per above item but from 5th Storey to 8th Storey |
| 14 | All as per above item but from 9th Storey to 12th Storey |
| 15 | All as per above item but from 13th Storey to 16th Storey |
| 16 | M&L for 25 mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in sub base offloors all as specified and as directed. |
| 17 | All as per above item but from 5th Storey to 8th Storey |
| 18 | All as per above item but from 9th Storey to 12th Storey |
| 19 | All as per above item but from 13th Storey to 16th Storey |
| 20 | M&L for 7 to 8 mm thick non-skid coloured (light shade) ceramic joint free tiles with tile spacer of minimum 3 mm thickness, area of each tile exceeding 0.18 Sqm and not exceeding 0.38 Sqm as in floors set and jointed neat with epoxy grout and masking tape shall be put before putting the epoxy grout, grout shall be througly cleaned immediatlely and pointedin white or coloured to match the shade of the tile and laid over screed bed or bedding layer in CM 1:6, 15 mm thick complete all as specified and as directed. |
| 21 | All as per above item but from 5th Storey to 8th Storey |
| 22 | All as per above item but from 9th Storey to 12th Storey |
| 23 | All as per above item but from 13th Storey to 16th Storey |
| 24 | All as per SI item No 20 above (including tile spacer, epoxy grout, masking tape etc), but as in skirting, dados etc, including rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 as in backing coat for fixing of tiles complete all as specified and as directed. |
| 25 | All as per above item but from 5th Storey to 8th Storey |
| 26 | All as per above item but from 9th Storey to 12th Storey |
| 27 | All as per above item but from 13th Storey to 16th Storey |
| 28 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises where directed and leaving the work clear complete all as specified and as directed |
| 29 | All as per above item but from 5th Storey to 8th Storey |
| 30 | All as per above item but from 9th Storey to 12th Storey |
| 31 | All as per above item but from 13th Storey to 16th Storey |
| 32 | M&L for 7 to 8 mm thick non-skid coloured (light shade) ceramic joint free tiles with tile spacer of minimum 3 mm thickness, area of each tile exceeding 0.11 Sqm and not exceeding 0.18 Sqm as in floors set and jointed neat with epoxy grout and masking tape shall be put before putting the epoxy grout, grout shall be througly cleaned immediatlely and pointedin white or coloured to match the shade of the tile and laid over screed bed or bedding layer in CM 1:6, 15 mm thick complete all as specified and as directed. |
| 33 | All as per above item but from 5th Storey to 8th Storey |
| 34 | All as per above item but from 9th Storey to 12th Storey |
| 35 | All as per above item but from 13th Storey to 16th Storey |
| 36 | Dismantling floor, hearth or wall tiling including CM bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and as directed. |
| 37 | All as per above item but from 5th Storey to 8th Storey |
| 38 | All as per above item but from 9th Storey to 12th Storey |
| 39 | All as per above item but from 13th Storey to 16th Storey |
| 40 | M&L for 300x450 mm size 7 to 8 mm thick Glazed ceramic joint free tiles with tile spacer of minimum thickess 3mm as in vertical surface set and jointed neat with epoxy grout and masking tape shall be put before putting the epoxy grout, grout shall be througly cleaned immediatlely and pointedin white or coloured to match the shade of the tile including rendering 10 mm thick in CM 1:4 as in backing coat for fixing of tiles complete all as specified and as directed. Note: Rate includes for cutting for offsets etc., |
| 41 | All as per above item but from 5th Storey to 8th Storey |
| 42 | All as per above item but from 9th Storey to 12th Storey |
| 43 | All as per above item but from 13th Storey to 16th Storey |
| 44 | S&FPVC cornerhalf round cornerbeading notexe 15 mm girth fixed totile junctions all as directedup to 16th floor complete all as specified and as directed. |
| 45 | M&L for PCC 1:5:10type E2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete all as specified and as directed. |
| 46 | All as per above item but from 5th Storey to 8th Storey |
| 47 | All as per above item but from 9th Storey to 12th Storey |
| 48 | All as per above item but from 13th Storey to 16th Storey |
| 49 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4, mixed with WPC and finishing the surface even and smooth without using extra cement complete all as specified and as directed. Note :- WPC measured separately. |
| 50 | All as per above item but from 5th Storey to 8th Storey |
| 51 | All as per above item but from 9th Storey to 12th Storey |
| 52 | All as per above item but from 13th Storey to 16th Storey |
| 53 | M&L for applying Chemical Injection Treatment in the form of Pressure Grouting by drilling 20 mm dia holes, 60 mm deep @ 100 cm grid at at junction of bottom floor and all the internal wall surfaces of the sunken slabs of toilet by injecting cement slurry mixed with grout admixture \"CONBEXTRA EP 10\" ofM/s. Fosroc Chemicals or its equivalent in M/s Sikaor M/s STPorM/s Choksey Chemicals or M/s Batik at 225 Grams for 50 KG of cement and applying a coat of Brush Bond RFX of M/s. Fosroc Chemicals or equivalent approved water proofing coating as per manufacturer\"s instructions complete all as required, as directed at site and as described in clause of PS. |
| 54 | All as per above item but from 5th Storey to 8th Storey |
| 55 | All as per above item but from 9th Storey to 12th Storey |
| 56 | All as per above item but from 13th Storey to 16th Storey |
| 57 | Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbishoutside MD Land within 100 m all as specified and as directed. |
| 58 | All as per above item but from 5th Storey to 8th Storey |
| 59 | All as per above item but from 9th Storey to 12th Storey |
| 60 | All as per above item but from 13th Storey to 16th Storey |
| 61 | M&L for Fair finished flat Form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exceeding 200 mm thick all as specified and as directed. |
| 62 | All as per above item but from 5th Storey to 8th Storey |
| 63 | All as per above item but from 9th Storey to 12th Storey |
| 64 | All as per above item but from 13th Storey to 16th Storey |
| 65 | M&L for Reinforced Cement Concrete (Nominal Mix) 1:2:4type B1 (using 20 mm graded stone aggregate) for slabs suspended on walls, beams and columns, floors, roofs, landings and in shelves and the like all as specified and as directed. |
| 66 | All as per above item but from 5th Storey to 8th Storey |
| 67 | All as per above item but from 9th Storey to 12th Storey |
| 68 | All as per above item but from 13th Storey to 16th Storey |
| 69 | M&L for mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips all as specified and as directed. |
| 70 | All as per above item but from 5th Storey to 8th Storey |
| 71 | All as per above item but from 9th Storey to 12th Storey |
| 72 | All as per above item but from 13th Storey to 16th Storey |
| 73 | M&L for mild steel TMT round bars 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips all as specified and as directed. |
| 74 | All as per above item but from 5th Storey to 8th Storey |
| 75 | All as per above item but from 9th Storey to 12th Storey |
| 76 | All as per above item but from 13th Storey to 16th Storey |
| 77 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m complete all as specified and as directed. |
| 78 | All as per above item but from 5th Storey to 8th Storey |
| 79 | All as per above item but from 9th Storey to 12th Storey |
| 80 | All as per above item but from 13th Storey to 16th Storey |
| 81 | M&L for brick work with fly ash bricks, straight or curved on plan not exceeding 6M mean radius built in cement mortar 1:6 upto 4th storey complete all as specified and as directed. |
| 82 | All as per above item but from 5th Storey to 8th Storey |
| 83 | All as per above item but from 9th Storey to 12th Storey |
| 84 | All as per above item but from 13th Storey to 16th Storey |
| 85 | M&L for brick work with fly ash bricks, straight or curved on plan to any radius in half brick wall built in cement mortar 1:4 upto 4th storey complete all as specified and as directed. |
| 86 | All as per above item but from 5th Storey to 8th Storey |
| 87 | All as per above item but from 9th Storey to 12th Storey |
| 88 | All as per above item but from 13th Storey to 16th Storey |
| 89 | M&L for rendering 10 mm thick on brick work or concrete surfaces in CM 1: 6 and finished even and smooth without using extra cement upto 4th storey complete all as specified and directed. |
| 90 | All as per above item but from 5th Storey to 8th Storey |
| 91 | All as per above item but from 9th Storey to 12th Storey |
| 92 | All as per above item but from 13th Storey to 16th Storey |
| 93 | S&Fstainless steelsink with drainage board over all size of 915x460 mm bowl size 410x330x160 mm with plugs washers and waste coupling upto 04th storey including necessary supporting brackets complete all as specified and as directed |
| 94 | All as per above item but from 5th Storey to 8th Storey |
| 95 | All as per above item but from 9th Storey to 12th Storey |
| 96 | All as per above item but from 13th Storey to 16th Storey |
| 97 | S&F stainless steel plate rack 1.50 mm thickof over all size 600x900x250 mmas per trade pattern upto 04th storey complete all as specified and as directed |
| 98 | All as per above item but from 5th Storey to 8th Storey |
| 99 | All as per above item but from 9th Storey to 12th Storey |
| 100 | All as per above item but from 13th Storey to 16th Storey |
| 101 | Cutting/chipping the spalling concrete surfaces of columns, beams, cantilever etc and trimming & cleaning the surface to receive guniting/plastering all as specified and directed including all necessary form work & scaffolding and safety measures and lowering down the demolished material for disposal and disposing the demolition material out of MD land upto 04th storey complete all as specified and as directed |
| 102 | All as per above item but from 5th Storey to 8th Storey |
| 103 | All as per above item but from 9th Storey to 12th Storey |
| 104 | All as per above item but from 13th Storey to 16th Storey |
| 105 | Providing pressure guniting averaging 25mm thick in cement mortar 1:3 for soffits of slabs, chajjas etc., complete all as specified and directed including providing double scaffolding as required and removal of the same on completion of the work, all as required and directed and applying one coat of Epoxy Treatment [Nito Bond AR of M/s. Fosroc or its equivalent in M/s. Dr. Fixit (as per Manufacturer instruction) prior to guniting to facilitate proper bonding with old surfaces complete all as specified and as directed upto 04th storey |
| 106 | All as per above item but from 5th Storey to 8th Storey |
| 107 | All as per above item but from 9th Storey to 12th Storey |
| 108 | All as per above item but from 13th Storey to 16th Storey |
| 109 | Providing pressure gunniting averaging 30 mm thick in cement mortar 1:3 for columns / beams/ fins/parapets complete all as specified and directed including providing double scaffolding as required and removal of the same on completion of the work, all as required and directed and applying Epoxy Treatment [Nito Bond AR of M/s. Fosroc or its equivalent in M/s. Dr. Fixit] prior to guniting to facilitate proper bonding with old surfaces complete all as specified and as directed. upto 04th storey |
| 110 | All as per above item but from 5th Storey to 8th Storey |
| 111 | All as per above item but from 9th Storey to 12th Storey |
| 112 | All as per above item but from 13th Storey to 16th Storey |
| 113 | M&L for Providing & Pouring Micro concreting M-40 grade :-(i) Dry the concrete substrate surface and clean it free of debris & dust(ii) Apply Epoxy bond coat on the sound concrete sub strate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above, pour Micro concreting M-40 grade, Make : Master Emaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, formwork, lead & lift of materials, transportation etc., to carry out the complete work upto 16th floor all as specified and directed. |
| 114 | M/L to Fair finished flat Form work to fins, louvers, fascias,parapets chajjasand similar works all as specified and as directed. |
| 115 | M&L for Reinforced Cement Concrete (Nominal Mix)1:11/2:3 Type A1 (using 20 mm graded stone aggregate) for fins, fascias, parapets, Chajjas and the like.all as specified and as directed. |
| 116 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises where directed and leaving the work clear complete all as specified and as directed |
| 117 | All as per above item but from 5th Storey to 8th Storey |
| 118 | All as per above item but from 9th Storey to 12th Storey |
| 119 | All as per above item but from 13th Storey to 16th Storey |
| 120 | M&L for rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:6 finished even and smooth withut using extra cement complete all as specified and as directed |
| 121 | All as per above item but from 5th Storey to 8th Storey |
| 122 | All as per above item but from 9th Storey to 12th Storey |
| 123 | All as per above item but from 13th Storey to 16th Storey |
| 124 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:6, 5mm thick in CM 1:4 mixed with WPC and finished even and smooth withut using extra cement complete all as specified and as directed. Note :- WPC measured separately. |
| 125 | All as per above item but from 5th Storey to 8th Storey |
| 126 | All as per above item but from 9th Storey to 12th Storey |
| 127 | All as per above item but from 13th Storey to 16th Storey |
| 128 | M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces in CM 1:3 and finished fair and even without using extra cement complete all as specified and as directed |
| 129 | All as per above item but from 5th Storey to 8th Storey |
| 130 | All as per above item but from 9th Storey to 12th Storey |
| 131 | All as per above item but from 13th Storey to 16th Storey |
| 132 | M&L for preparing newly plastered surfaces of ceilings and and applying three coats of white wash up to 4th storey complete all as specified and as directed. |
| 133 | All as per above item but from 5th Storey to 8th Storey |
| 134 | All as per above item but from 9th Storey to 12th Storey |
| 135 | All as per above item but from 13th Storey to 16th Storey |
| 136 | M&L for preparation of old plastered surface steel surfaces of any description, and girth, not otherwise described and applying one coat of synthetic enamel paint (ordinary tint) upto 4th storey complete all as specified and as directed. |
| 137 | All as per above item but from 5th Storey to 8th Storey |
| 138 | All as per above item but from 9th Storey to 12th Storey |
| 139 | All as per above item but from 13th Storey to 16th Storey |
| 140 | Preparation of newly plastered wall/ceilings surfaces and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete as per manufacturer\"s specifications, two or more coats on new work includingProviding and applying putty of suitable thickness over plastered surface to prepare the surface even and smooth and one coat of primer with alkali resistant priming paint upto 4th storey complete all as specified and as directed. |
| 141 | All as per above item but from 5th Storey to 8th Storey |
| 142 | All as per above item but from 9th Storey to 12th Storey |
| 143 | All as per above item but from 13th Storey to 16th Storey |
| 144 | Complete removal of existing treatment and preparation of newly plastered wall / ceilings surfaces and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete as per manufacturer\"s specification. Two or more coats including Providing and applying putty of suitable thickness over plastered surface to prepare the surface even and smooth and one coat of primer with alkali resistant priming paint upto 4th storey complete all as specified and as directed. |
| 145 | All as per above item but from 5th Storey to 8th Storey |
| 146 | All as per above item but from 9th Storey to 12th Storey |
| 147 | All as per above item but from 13th Storey to 16th Storey |
| 148 | M&L for preparation of old painted woodensurface of any description not othrwise described over 10cm width or girth and applying one coat of synthetic enamel paint upto 4 th storey complete all as specified and directed. |
| 149 | All as per above item but from 5th Storey to 8th Storey |
| 150 | All as per above item but from 9th Storey to 12th Storey |
| 151 | All as per above item but from 13th Storey to 16th Storey |
| 152 | Preparing old surfaces of walls /ceiling applying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shad (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm including Providing and applying exterior putty of suitable thickness over plastered surface to prepare the surface even and smooth. |
| 153 | Preparation of new plastered wall surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shad (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm including Providing and applying exterior putty of suitable thickness over plastered surface to prepare the surface even and smooth. |
| 154 | M & L Writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30 cm high upto 4 storey complete all as specified and as directed. |
| 155 | All as per above item but from 5th Storey to 8th Storey |
| 156 | All as per above item but from 9th Storey to 12th Storey |
| 157 | All as per above item but from 13th Storey to 16th Storey |
| 158 | Taking down CI pipe soil, waste and rain water pipes (any size or pattern) including all fittings, heads, shoes. Bends, swan-necks etc up to 04 storeyincluding cleaning or refixing or removal to store complete all as specified and as directed. |
| 159 | All as per above item but from 5th Storey to 8th Storey |
| 160 | All as per above item but from 9th Storey to 12th Storey |
| 161 | All as per above item but from 13th Storey to 16th Storey |
| 162 | S&F 160 mm bore UPVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls upto 04 storey complete all as specified and as directed. [Sky rise Hitech Low noise SWR drainage system] |
| 163 | All as per above item but from 5th Storey to 8th Storey |
| 164 | All as per above item but from 9th Storey to 12th Storey |
| 165 | All as per above item but from 13th Storey to 16th Storey |
| 166 | S&F 110 mm bore UPVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls upto 04 storey complete all as specified and as directed. [Sky rise Hitech Low noise SWR drainage system] |
| 167 | All as per above item but from 5th Storey to 8th Storey |
| 168 | All as per above item but from 9th Storey to 12th Storey |
| 169 | All as per above item but from 13th Storey to 16th Storey |
| 170 | S&F 75 mm bore UPVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls upto 04 storey complete all as specified and as directed. |
| 171 | All as per above item but from 5th Storey to 8th Storey |
| 172 | All as per above item but from 9th Storey to 12th Storey |
| 173 | All as per above item but from 13th Storey to 16th Storey |
| 174 | S&F 75 mm bore UPVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to floors upto 04 storey complete all as specified and as directed. [Sky rise Hitech Low noise SWR drainage system] |
| 175 | All as per above item but from 5th Storey to 8th Storey |
| 176 | All as per above item but from 9th Storey to 12th Storey |
| 177 | All as per above item but from 13th Storey to 16th Storey |
| 178 | S&F 110 mm bore UPVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to floors upto 04 storey complete all as specified and as directed. [Sky rise Hitech Low noise SWR drainage system] |
| 179 | All as per above item but from 5th Storey to 8th Storey |
| 180 | All as per above item but from 9th Storey to 12th Storey |
| 181 | All as per above item but from 13th Storey to 16th Storey |
| 182 | M&L for PVC (SWR) plain Floor/ Nahani trap of 75 mm dia outlet with grating including jointing with solvent cement complete all as specified and as directed. |
| 183 | All as per above item but from 5th Storey to 8th Storey |
| 184 | All as per above item but from 9th Storey to 12th Storey |
| 185 | All as per above item but from 13th Storey to 16th Storey |
| 186 | S&F160 mm bore UPVC (SWR) junction single TEqual / unequal with access door complete all as specified and as directed |
| 187 | All as per above item but from 5th Storey to 8th Storey |
| 188 | All as per above item but from 9th Storey to 12th Storey |
| 189 | All as per above item but from 13th Storey to 16th Storey |
| 190 | S&F 110 mm bore UPVC (SWR) junction single TEqual / unequal with access door complete all as specified and as directed |
| 191 | All as per above item but from 5th Storey to 8th Storey |
| 192 | All as per above item but from 9th Storey to 12th Storey |
| 193 | All as per above item but from 13th Storey to 16th Storey |
| 194 | S&F 75 mm bore UPVC (SWR) junction single TEqual / unequal with access door complete all as specified and as directed |
| 195 | All as per above item but from 5th Storey to 8th Storey |
| 196 | All as per above item but from 9th Storey to 12th Storey |
| 197 | All as per above item but from 13th Storey to 16th Storey |
| 198 | S&F 75 mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 199 | All as per above item but from 5th Storey to 8th Storey |
| 200 | All as per above item but from 9th Storey to 12th Storey |
| 201 | All as per above item but from 13th Storey to 16th Storey |
| 202 | S&F 110 mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 203 | All as per above item but from 5th Storey to 8th Storey |
| 204 | All as per above item but from 9th Storey to 12th Storey |
| 205 | All as per above item but from 13th Storey to 16th Storey |
| 206 | S&F 110 mm bore UPVC (SWR) branch piece, single (single Y) equal or unequal with access door complete all as specified and as directed |
| 207 | All as per above item but from 5th Storey to 8th Storey |
| 208 | All as per above item but from 9th Storey to 12th Storey |
| 209 | All as per above item but from 13th Storey to 16th Storey |
| 210 | S&F 160 mm bore UPVC (SWR) vent cowl complete all as specified and as directed |
| 211 | S&F 75 mm bore UPVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls upto 04 storey complete all as specified and as directed. [Sky rise Hitech Low noise SWR drainage system] |
| 212 | All as per above item but from 5th Storey to 8th Storey |
| 213 | All as per above item but from 9th Storey to 12th Storey |
| 214 | All as per above item but from 13th Storey to 16th Storey |
| 215 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal to storeup to 4 th storey complete all as specified and as directed. |
| 216 | All as per above item but from 5th Storey to 8th Storey |
| 217 | All as per above item but from 9th Storey to 12th Storey |
| 218 | All as per above item but from 13th Storey to 16th Storey |
| 219 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to storeup to 4 th storey complete all as specified and as directed. |
| 220 | All as per above item but from 5th Storey to 8th Storey |
| 221 | All as per above item but from 9th Storey to 12th Storey |
| 222 | All as per above item but from 13th Storey to 16th Storey |
| 223 | Taking up or down 25 to 32 mm bore steel tubing and connections, including cleaning for Refixing or removal to storeup to 4 th storey complete all as specified and as directed. |
| 224 | All as per above item but from 5th Storey to 8th Storey |
| 225 | All as per above item but from 9th Storey to 12th Storey |
| 226 | All as per above item but from 13th Storey to 16th Storey |
| 227 | Taking up or down 40 to 50 mm bore steel tubing and connections, including cleaning for Refixing or removal to storeup to 4 th storey complete all as specified and as directed. |
| 228 | All as per above item but from 5th Storey to 8th Storey |
| 229 | All as per above item but from 9th Storey to 12th Storey |
| 230 | All as per above item but from 13th Storey to 16th Storey |
| 231 | Supplying and laying of CPVC pipes 20mm dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorscomplete all as specified. |
| 232 | All as per above item but from 5th Storey to 8th Storey |
| 233 | All as per above item but from 9th Storey to 12th Storey |
| 234 | All as per above item but from 13th Storey to 16th Storey |
| 235 | Supplying and laying of CPVC pipes 25mm dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorscomplete all as specified. |
| 236 | All as per above item but from 5th Storey to 8th Storey |
| 237 | All as per above item but from 9th Storey to 12th Storey |
| 238 | All as per above item but from 13th Storey to 16th Storey |
| 239 | Supplying and laying of CPVC pipes 40mm dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorscomplete all as specified. |
| 240 | All as per above item but from 5th Storey to 8th Storey |
| 241 | All as per above item but from 9th Storey to 12th Storey |
| 242 | All as per above item but from 13th Storey to 16th Storey |
| 243 | Supplying and laying of CPVC pipes 50mm dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed. |
| 244 | All as per above item but from 5th Storey to 8th Storey |
| 245 | All as per above item but from 9th Storey to 12th Storey |
| 246 | All as per above item but from 13th Storey to 16th Storey |
| 247 | Supplying and laying of CPVC pipes 75 mm dia, with CPVC Schedule 80 pipes & plain CPVC Schedule 80 fittings on walls/ceiling or laying in floorscomplete all as specified |
| 248 | All as per above item but from 5th Storey to 8th Storey |
| 249 | All as per above item but from 9th Storey to 12th Storey |
| 250 | All as per above item but from 13th Storey to 16th Storey |
| 251 | S&F in repairs 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule. up to 4 th storey complete all as specified and as directed. |
| 252 | All as per above item but from 5th Storey to 8th Storey |
| 253 | All as per above item but from 9th Storey to 12th Storey |
| 254 | All as per above item but from 13th Storey to 16th Storey |
| 255 | S&F in repairs fancy type chromium plated 15 mm bore angle/ plain Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions including taking down the existing fitting complete all as specified and as directed. |
| 256 | All as per above item but from 5th Storey to 8th Storey |
| 257 | All as per above item but from 9th Storey to 12th Storey |
| 258 | All as per above item but from 13th Storey to 16th Storey |
| 259 | S&F in repairs two waybib tap CP 15 mm Dia cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions up to 4 th Floor complete all as specified and as directed.Make: CAT No. ARI-CHR-39037 of Jaquar or its equivalent as approved by GE. |
| 260 | All as per above item but from 5th Storey to 8th Storey |
| 261 | All as per above item but from 9th Storey to 12th Storey |
| 262 | All as per above item but from 13th Storey to 16th Storey |
| 263 | S&F in repairs Chromium plated shower rose 125 mm size with or without swivel joints complete all as specified and as directed.Make: Cat No.OHS-CHR-1661 of Jaquar or its equivalent cat No & make as per list of makes |
| 264 | All as per above item but from 5th Storey to 8th Storey |
| 265 | All as per above item but from 9th Storey to 12th Storey |
| 266 | All as per above item but from 13th Storey to 16th Storey |
| 267 | S&F in repairs 80 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe complete all as specified and as directed. |
| 268 | S&F in repairs 50 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe complete all as specified and as directed. |
| 269 | S&F in repairs 25 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe upto 16th stoprey complete all as specified and as directed. |
| 270 | All as per above item but from 5th Storey to 8th Storey |
| 271 | All as per above item but from 9th Storey to 12th Storey |
| 272 | All as per above item but from 13th Storey to 16th Storey |
| 273 | S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed. |
| 274 | All as per above item but from 5th Storey to 8th Storey |
| 275 | All as per above item but from 9th Storey to 12th Storey |
| 276 | All as per above item but from 13th Storey to 16th Storey |
| 277 | S&F in repairs Stainless steel Soap dish, any type, fixed to plugs with CP brass screws complete all as specified and as directed.Make: Cat No. CPA-CHR-1131 of Jaquar or its equivalent make as per list of makes) |
| 278 | All as per above item but from 5th Storey to 8th Storey |
| 279 | All as per above item but from 9th Storey to 12th Storey |
| 280 | All as per above item but from 13th Storey to 16th Storey |
| 281 | S&F in repairs Towel Ring sqaure, Stainless steel, Fancy Type fixed with chromium plated brass screws and wooden/plastic cleats weighing minimum 90 gms complete all as specified and as directed.Make: Cat No. AQN-BCH-7721 of Jaquar or its equivalent cat No & make as per list of makes) |
| 282 | All as per above item but from 5th Storey to 8th Storey |
| 283 | All as per above item but from 9th Storey to 12th Storey |
| 284 | All as per above item but from 13th Storey to 16th Storey |
| 285 | S&F in repairs Brass Chromium plated tubular towel rail, 20 mm dia., D Type, 60 cm long between flanges complete all as specified and as directed.Make: Cat No. AQN-GRF-7711B of Jaquar or its equivalent cat No & make as per list of makes |
| 286 | All as per above item but from 5th Storey to 8th Storey |
| 287 | All as per above item but from 9th Storey to 12th Storey |
| 288 | All as per above item but from 13th Storey to 16th Storey |
| 289 | S&F in repairs600x450 mm beveled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washer complete all as specified and as directed.. |
| 290 | All as per above item but from 5th Storey to 8th Storey |
| 291 | All as per above item but from 9th Storey to 12th Storey |
| 292 | All as per above item but from 13th Storey to 16th Storey |
| 293 | S&F in repairs Vitreous China (white) EWC type water closet floor mounted (size 560x440x395 mm or nearest size) confirming to IS 2556 part II of pattern 1 having P trap with 10 litres PVC capacity valve less syphonic action type flushing cistern low level (white) with inlet, ball valve, float and handle including brackets (SLIM LINE or equivalent) including PVC flush pipe 32 mm dia, plastic seat cover of white colour to WC (which shall be thermosetting materal confirming to IS 2538, underside of seat shall be flat and seat shall be of solid moulding 3mm thick & cover shall be 3 mm thick), hinging device brass chromium plated 2 bolts per seat, 4 numbers rubber plastic buffers including removing the existing water closet complete upto 4th storey complete all as specified and as directed. |
| 294 | All as per above item but from 5th Storey to 8th Storey |
| 295 | All as per above item but from 9th Storey to 12th Storey |
| 296 | All as per above item but from 13th Storey to 16th Storey |
| 297 | S&F in repairs Rotational moulded Polythene (HDPE) rectangle Water storage loft Tank, 275 Liters Capacity hoisted and fixed in position upto 4 th storey including dismantling water tanks and removing to store upto 16th storey complete all as specified and as directed. |
| 298 | S & F 20 mm dia Ball brass Valves, high pressure, with polythene float and fly nut complete, screwed for Iron pipe or brass ferrule |
| 299 | S&F Vitreous China Ware Wash hand basin white, flat back, size 560x415 mm with 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed including removing the existing Basin, pillar tap and brackets and fixing new brackets complete complete all as specified and as directed.Make: Cat No. SLS-WHT-6901 of Jaquar or its equivalent Cat No & Make given in list of makes. |
| 300 | All as per above item but from 5th Storey to 8th Storey |
| 301 | All as per above item but from 9th Storey to 12th Storey |
| 302 | All as per above item but from 13th Storey to 16th Storey |
| 303 | S & F in repairs Vitreous China Ware Wash hand basin white,half pedestal, flat back, size 315x450x175 mm size with 15 mm bore swan neck pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed including removing the existing Basin, pillar tap and brackets and fixing new brackets complete.Jaquar Cat No. Make: Cat No.JDS-WHT-25841 of Jaquar or its equivalent Cat No & Make given in list of makes. |
| 304 | All as per above item but from 5th Storey to 8th Storey |
| 305 | All as per above item but from 9th Storey to 12th Storey |
| 306 | All as per above item but from 13th Storey to 16th Storey |
| 307 | Taking down Chowkats or frames with shutters not exceeding 1.5 Sq. m each (Without taking off shutters from the frames) complete all as specified and as directed.. |
| 308 | All as per above item but from 5th Storey to 8th Storey |
| 309 | All as per above item but from 9th Storey to 12th Storey |
| 310 | All as per above item but from 13th Storey to 16th Storey |
| 311 | Taking down Chowkats or frames with shutters exceeding 1.5 Sq. m but not exceeding 4 Sq. m each (Without taking off shutters from the frame) complete all as specified and as directed.. |
| 312 | All as per above item but from 5th Storey to 8th Storey |
| 313 | All as per above item but from 9th Storey to 12th Storey |
| 314 | All as per above item but from 13th Storey to 16th Storey |
| 315 | S & F factory made single extruded WPC (Wood Polymer Composite) of make ALSTONE/REYNOARCH/MOONSTONE solid door/window/Ceosetory windows & other Frames/Chowkhat of size 65x125mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with SS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge.Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 316 | All as per above item but from 5th Storey to 8th Storey |
| 317 | All as per above item but from 9th Storey to 12th Storey |
| 318 | All as per above item but from 13th Storey to 16th Storey |
| 319 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) of make ALSTONE/REYNOARCH / MOONSTONE solid door/window/Ceosetory windows & other Frames/Chowkhat of size 65x100mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with SS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In-Charge. |
| 320 | All as per above item but from 5th Storey to 8th Storey |
| 321 | All as per above item but from 9th Storey to 12th Storey |
| 322 | All as per above item but from 13th Storey to 16th Storey |
| 323 | Providing and fixing factory /Machine made modular cupboards, kitchen cabinets, overhead cabinets, counters below wash basins of any depth & size including drawers shelves in required numbers and similar work, manufactured with 18 mm thick WPC Hybrid grade of approved brand (Alstone /Reynoarch/ Moonstone) , In sides, top, bottom, vertical partitions and shutter, and 12 mm thick for backing ofWPC Hybrid grade of approved brand (Alstone/ Reynoarch/ Moonstone)inback of kitchen Cabinet, including providing andfixing 1 mm thick laminated sheet (Alstone / Reynoarch/ Moonstone)in all inner side and 1.00 mm thick on front of shutters & exposed sides of cabinets including providing and fixing teak wood margin of PVC edge band tape on all edges of cabinet including shutters and including the cost of all fitting, such as nails, screws, adhesive dowels, connecting screws, minifix, etc. required to complete this items as described above, and also the cost of auto closing hinges of approved make for fixing of shutters with necessary screws etcand fixing shutter with cabinets by making necessary rebatein shutter/cabinet etc. complete. Cabinet to be fixed in proper place/such as under counter of kitchen or over heads above the counter with required dash fasteners etc. all operation complete including Drawer channels as per direction of Engineer-in Charge.Note: Details Drawings shall be submitted by the contractor and got approved from the Engineer-in-Charge |
| 324 | All as per above item but from 5th Storey to 8th Storey |
| 325 | All as per above item but from 9th Storey to 12th Storey |
| 326 | All as per above item but from 13th Storey to 16th Storey |
| 327 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, complete all as specified and as directed. (Note:- SS butt hinges with necessary SS screws shall be measured separately) |
| 328 | All as per above item but from 5th Storey to 8th Storey |
| 329 | All as per above item but from 9th Storey to 12th Storey |
| 330 | All as per above item but from 13th Storey to 16th Storey |
| 331 | S&F 35mm thick factory made second class hard wood, kiln seasoned and chemically pressure treated plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm thick veneered partilce board complete all as specified and as directed. |
| 332 | All as per above item but from 5th Storey to 8th Storey |
| 333 | All as per above item but from 9th Storey to 12th Storey |
| 334 | All as per above item but from 13th Storey to 16th Storey |
| 335 | S & F Factory made Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed. |
| 336 | All as per above item but from 5th Storey to 8th Storey |
| 337 | All as per above item but from 9th Storey to 12th Storey |
| 338 | All as per above item but from 13th Storey to 16th Storey |
| 339 | Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs.The frame shall be covered with fiber glass from all sides.M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer andas per directions of Engineer-in-charge. |
| 340 | All as per above item but from 5th Storey to 8th Storey |
| 341 | All as per above item but from 9th Storey to 12th Storey |
| 342 | All as per above item but from 13th Storey to 16th Storey |
| 343 | Supply and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856 complete all as specified by the manufacturer and as per directions of Engineer- in-charge |
| 344 | All as per above item but from 5th Storey to 8th Storey |
| 345 | All as per above item but from 9th Storey to 12th Storey |
| 346 | All as per above item but from 13th Storey to 16th Storey |
| 347 | Factory made single extruded WPC (Wood Polymer Composite) kitchen cabinet Frames/ Chowkhat/TV cabinet of size 50 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance tospread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with SS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. ® Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 348 | All as per above item but from 5th Storey to 8th Storey |
| 349 | All as per above item but from 9th Storey to 12th Storey |
| 350 | All as per above item but from 13th Storey to 16th Storey |
| 351 | S & F Door Closer Hydraulically Regulated, Designation No. 3 universal type, suitable for door shutters of 851 mm to 1000 mm in width and of weight between 61 to 80 Kg of aluminium body complete all as specified and as directed. |
| 352 | All as per above item but from 5th Storey to 8th Storey |
| 353 | All as per above item but from 9th Storey to 12th Storey |
| 354 | All as per above item but from 13th Storey to 16th Storey |
| 355 | M&L for Powder coated aluminium sections of approved colour for doors, Windows, Ventilators, Partitions, with frames and shutters fully or partly glazed, sliding / openable, with extrudedaluminium sections not less than 1.5mm thick and powder coating not less than 60 micron thick including necessary jointing cleats, rubber beading, neoprene packing, aluminium snap beading, screws, powder coated aluminium fittings such as handles, aluminium butt hinges , aluminium tower bolts, stainless steel friction hinges, locking arrangementsetc. upto 16th storey complete all as specified and as directed. Notes:(a)The size of aluminium extruded sections shall conform to Designation 63400 all shall be as specified in relevant IS code and as specified in MES Schedule Part - I. (b) Panel inserts such as Glass / Particle board / Gauze shall be measured and paid separately at supply only rates.(c) Weight of aluminium sections shall only be accounted for payment purpose. Weight of aluminium Handles, Butt Hinges & Tower Bolts shall not be accounted for payment purpose. (d) The unit rate quoted shall be deemed to include for cost of jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts, stainless steel friction hinges, Peg stays, locking arrangementsetc., and fixing only of panel inserts ofglass / particle board / gauge etc. (e) While making payment in kgs, the wt arrived from differerent sections shall be tallied with total wt of doors, Windows, Ventilators, Partitions with frames and shutters. |
| 356 | Supply only 4.8 mm thick Sheet glass, ordinary quality fixed to in squares exceeding 0.5 Sq. M in each pane complete all as specified and as directed. |
| 357 | All as per above item but from 5th Storey to 8th Storey |
| 358 | All as per above item but from 9th Storey to 12th Storey |
| 359 | All as per above item but from 13th Storey to 16th Storey |
| 360 | S&F powder coatedaluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/ stainlesssteel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement and direction. |
| 361 | All as per above item but from 5th Storey to 8th Storey |
| 362 | All as per above item but from 9th Storey to 12th Storey |
| 363 | All as per above item but from 13th Storey to 16th Storey |
| 364 | S&F 35 mm thick factory made Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc. The sizes of members of shutters shall be as specified in SSR Part I, Section 8, Clause 8.20 (a) complete all as specified and as directed. |
| 365 | All as per above item but from 5th Storey to 8th Storey |
| 366 | All as per above item but from 9th Storey to 12th Storey |
| 367 | All as per above item but from 13th Storey to 16th Storey |
| 368 | M&L for Plain Cement Concrete1:3:6 Type C1 (using 20 mm graded stone aggregate) cast in situ in lintels up to 1.5 m span, cills and other similar bands, plinth courses, parapets, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work complete all as specified and as directed. |
| 369 | All as per above item but from 5th Storey to 8th Storey |
| 370 | All as per above item but from 9th Storey to 12th Storey |
| 371 | All as per above item but from 13th Storey to 16th Storey |
| 372 | Supply only Stainless Steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with Stainless steel wire staples complete all as specified and as directed. |
| 373 | All as per above item but from 5th Storey to 8th Storey |
| 374 | All as per above item but from 9th Storey to 12th Storey |
| 375 | All as per above item but from 13th Storey to 16th Storey |
| 376 | S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy. up to 4th storey complete all as specified and as directed. |
| 377 | All as per above item but from 5th Storey to 8th Storey |
| 378 | All as per above item but from 9th Storey to 12th Storey |
| 379 | All as per above item but from 13th Storey to 16th Storey |
| 380 | S&F in repairs 150 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy. up to 4th storey complete all as specified and as directed. |
| 381 | All as per above item but from 5th Storey to 8th Storey |
| 382 | All as per above item but from 9th Storey to 12th Storey |
| 383 | All as per above item but from 13th Storey to 16th Storey |
| 384 | S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed. |
| 385 | All as per above item but from 5th Storey to 8th Storey |
| 386 | All as per above item but from 9th Storey to 12th Storey |
| 387 | All as per above item but from 13th Storey to 16th Storey |
| 388 | S&F 600x450 mm Cabinet Mirror of selected quality and approved make, glass minimum 5 mm thick and fixed to wooden plug with CP brass screws and cup washers upto 16 storey complete all as specified and as directed. |
| 389 | S&F in repairs 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed. |
| 390 | All as per above item but from 5th Storey to 8th Storey |
| 391 | All as per above item but from 9th Storey to 12th Storey |
| 392 | All as per above item but from 13th Storey to 16th Storey |
| 393 | S&F 125 mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and as directed. |
| 394 | All as per above item but from 5th Storey to 8th Storey |
| 395 | All as per above item but from 9th Storey to 12th Storey |
| 396 | All as per above item but from 13th Storey to 16th Storey |
| 397 | S & Fin repairs125 mm long extruded SS Butt hinges with galvanized mild steel hingepin type D 22 complete all as specified and as directed. |
| 398 | All as per above item but from 5th Storey to 8th Storey |
| 399 | All as per above item but from 9th Storey to 12th Storey |
| 400 | All as per above item but from 13th Storey to 16th Storey |
| 401 | S&F 150 mm long extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 402 | All as per above item but from 5th Storey to 8th Storey |
| 403 | All as per above item but from 9th Storey to 12th Storey |
| 404 | All as per above item but from 13th Storey to 16th Storey |
| 405 | S&F in repairs 150 mm long extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 406 | All as per above item but from 5th Storey to 8th Storey |
| 407 | All as per above item but from 9th Storey to 12th Storey |
| 408 | All as per above item but from 13th Storey to 16th Storey |
| 409 | M & L for Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and as directed. |
| 410 | All as per above item but from 5th Storey to 8th Storey |
| 411 | All as per above item but from 9th Storey to 12th Storey |
| 412 | All as per above item but from 13th Storey to 16th Storey |
| 413 | Supply and fix in repairs Stainless Steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with Stainless steel wire staples complete all as specified and as directed. |
| 414 | All as per above item but from 5th Storey to 8th Storey |
| 415 | All as per above item but from 9th Storey to 12th Storey |
| 416 | All as per above item but from 13th Storey to 16th Storey |
| 417 | S & F storey door stopper of Aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in storey, Overall length of cover plate 150 mm. complete all as specified and as directed. |
| 418 | All as per above item but from 5th Storey to 8th Storey |
| 419 | All as per above item but from 9th Storey to 12th Storey |
| 420 | All as per above item but from 13th Storey to 16th Storey |
| 421 | S&F stainless Steel curtain rod 25mm dia with suitable chromium platedbrackets, with 100 mm PVC rings and Designer knobs at ends matching to curtain rod of make as as approved by GE upto 04 storey complete all as specified and as directed. Note: Additional supporting bracket shall be provided if length is exceeding 1.2m and rate quoted shall include for the same. |
| 422 | All as per above item but from 5th Storey to 8th Storey |
| 423 | All as per above item but from 9th Storey to 12th Storey |
| 424 | All as per above item but from 13th Storey to 16th Storey |
| 425 | Dismantling ply wood cub boardshutters including cubboard shelves complete all as specified and as directed. |
| 426 | All as per above item but from 5th Storey to 8th Storey |
| 427 | All as per above item but from 9th Storey to 12th Storey |
| 428 | All as per above item but from 13th Storey to 16th Storey |
| 429 | M&L for 18mm thick plywood BWR grade type BB fixed with Fevicol and nails for working table/storage almirah to the size and pattern as shown in Drg.Decorative laminate0.90 mmtype 1of surface finish, colour andpattern as approved, fixedwith approved adhesive as per manufacturer\"sinstructionsand as directed by Engr-in-charge |
| 430 | All as per above item but from 5th Storey to 8th Storey |
| 431 | All as per above item but from 9th Storey to 12th Storey |
| 432 | All as per above item but from 13th Storey to 16th Storey |
| 433 | M/L for Ist class H.W. plain cover fillets square, rectangular or triangular in section bull nosed, splayed chamfered or rounded on one edge or face in I st class H.W.sectional area n. exc. 6 Sqcm complete all as specified and as directed. |
| 434 | All as per above item but from 5th Storey to 8th Storey |
| 435 | All as per above item but from 9th Storey to 12th Storey |
| 436 | All as per above item but from 13th Storey to 16th Storey |
| 437 | S/F brass hinges 75mm size extruded with stainless steel pin type D-11 complete all as specified and as directed. |
| 438 | All as per above item but from 5th Storey to 8th Storey |
| 439 | All as per above item but from 9th Storey to 12th Storey |
| 440 | All as per above item but from 13th Storey to 16th Storey |
| 441 | S/F brass cup board lock 75mm size 4 level with duplicate keys complete all as specified and as directed. |
| 442 | All as per above item but from 5th Storey to 8th Storey |
| 443 | All as per above item but from 9th Storey to 12th Storey |
| 444 | All as per above item but from 13th Storey to 16th Storey |
| 445 | S/F brass handles extruded fabricated type75mm size complete all as specified and as directed. |
| 446 | All as per above item but from 5th Storey to 8th Storey |
| 447 | All as per above item but from 9th Storey to 12th Storey |
| 448 | All as per above item but from 13th Storey to 16th Storey |
| 449 | S/F brass handles extruded fabricated type100mm size complete all as specified and as directed. |
| 450 | All as per above item but from 5th Storey to 8th Storey |
| 451 | All as per above item but from 9th Storey to 12th Storey |
| 452 | All as per above item but from 13th Storey to 16th Storey |
| 453 | S&F magnetic catch complete all as specified and as directed. |
| 454 | All as per above item but from 5th Storey to 8th Storey |
| 455 | All as per above item but from 9th Storey to 12th Storey |
| 456 | All as per above item but from 13th Storey to 16th Storey |
| 457 | S&f 300 mm, Mild steel ordinary rat tail rod pattern springs including roller and roller plate upto 4 th storey complete all as specified and directed. |
| 458 | All as per above item but from 5th Storey to 8th Storey |
| 459 | All as per above item but from 9th Storey to 12th Storey |
| 460 | All as per above item but from 13th Storey to 16th Storey |
| 461 | Mortice night latch, of size 82mm, 7 levers ,Zink based die cast alloy body andtwo keysupto 4 th storey complete all as specified and directed. |
| 462 | All as per above item but from 5th Storey to 8th Storey |
| 463 | All as per above item but from 9th Storey to 12th Storey |
| 464 | All as per above item but from 13th Storey to 16th Storey |
| 465 | S&F Mild steel work in framed work such as grills, gratings,framed guard bars, barred iron doors, ladders etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe 410 - O or Fe 310 - O upto 4th storey complete all as specified and as directed. |
| 466 | All as per above item but from 5th Storey to 8th Storey |
| 467 | All as per above item but from 9th Storey to 12th Storey |
| 468 | All as per above item but from 13th Storey to 16th Storey |
| 469 | M&L for Providing and injecting chemical emulsion for Anti Termite Treatment along the external wall below concrete or masonry apron using chemical emulsion at the rate of 2.25 litres per linear metre including drilling and plugging holes etc., in apron complete all as specified and as directed. |
| 470 | M&L for treating the soil under exiting floor using lindane emulsifiable conforming to IS: 632 with emulsion @ 1 litre per hole 300mm apart including drilling and plugging 12mm dia hole with cement mortor 1:2 (1 cement : 2 sand) to match the existing floors complete all as specified and as directed. |
| 471 | M&L at point of contact to wood work by chemical emulsion (water base solution) @ 0.5 ltr / hole by drilling 6mm dia holes at a downward angle of 45 degree at 1.5 mm centre to centre and sealing the same upto 4th storey complete all as specified and as directed. |
| 472 | All as per above item but from 5th Storey to 8th Storey |
| 473 | All as per above item but from 9th Storey to 12th Storey |
| 474 | All as per above item but from 13th Storey to 16th Storey |
| 475 | S & F in repairs Wall Mixer with Handshower & Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs &Wall Flanges including all necessary fittings complete all as specified and as directed.Make: CAT No ORP-BCH-10117PM and HSH-CHR-1731 Jaquar make or its equivalent as approved by GE |
| 476 | S&F Second class hard wood small fittings such as brackets of any type, shaped door and window stops and the like including all necessary labour, articles not exceeding 200 Cu. Cm each complete all as specified and as directed. |
| 477 | All as per above item but from 5th Storey to 8th Storey |
| 478 | All as per above item but from 9th Storey to 12th Storey |
| 479 | All as per above item but from 13th Storey to 16th Storey |
| 480 | S&F mild steel, bright finished or electro galvanised continuous (piano) hinges width of flaps (when open) 40mm upto 4th storey complete all as specified and directed. |
| 481 | All as per above item but from 5th Storey to 8th Storey |
| 482 | All as per above item but from 9th Storey to 12th Storey |
| 483 | All as per above item but from 13th Storey to 16th Storey |
| 484 | S & F Mild steel or cast iron work in framed work such as grills, gratings, framed guard bars, barred iron doors, ladders etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe 410 - O or Fe 310 - O upto 16 th storey complete all as specified and directed |
| 485 | M&L for epoxy rubber paint of required coat for smooth finishing on metal or sny other suface all as specified and directed by Eng-in-charge. |
| 486 | M&L for demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laidd, bedded and pointedin any mortar complete all as specified and as directed. |
| 487 | M&L forMachine cut kota stone slab flooring 20-25mm thick laid over screed bed 15 mm thick in CM 1:6,jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing upto 4th storey complete all as specified and as directed. |
| 488 | All as per above item but from 5th Storey to 8th Storey |
| 489 | All as per above item but from 9th Storey to 12th Storey |
| 490 | All as per above item but from 13th Storey to 16th Storey |
| 491 | S&F Brass 4 lever locks for cup board ,Grade I, 50mm size upto 4 th storey complete all as specified and directed. |
| 492 | All as per above item but from 5th Storey to 8th Storey |
| 493 | All as per above item but from 9th Storey to 12th Storey |
| 494 | All as per above item but from 13th Storey to 16th Storey |
| 495 | S&F Aluminium Hat and Coat hooks , Solid body, 175mm to 250mm size upto 4 th storey complete all as specified and directed. |
| 496 | All as per above item but from 5th Storey to 8th Storey |
| 497 | All as per above item but from 9th Storey to 12th Storey |
| 498 | All as per above item but from 13th Storey to 16th Storey |
| 499 | S & F in repairs Aldrop, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws 125 mm size |
| 500 | All as per above item but from 5th Storey to 8th Storey |
| 501 | All as per above item but from 9th Storey to 12th Storey |
| 502 | All as per above item but from 13th Storey to 16th Storey |
| 503 | S&F in repairs MS sheet, plain, black sheet 1.25mm thick as in hearths covering to door shutters cut to size edges beaded, holes punched including round headed screws or riveted/ welded to steel members including bending, turning up mitred angles, stopped ends etc, all as directed including one coat of aluminim red oxide primer and two coats of aluminium paint upto 4th storey complete all as specified and directed. |
| 504 | All as per above item but from 5th Storey to 8th Storey |
| 505 | All as per above item but from 9th Storey to 12th Storey |
| 506 | All as per above item but from 13th Storey to 16th Storey |
| 507 | Grouting Packers 8 MM :- Supply and installation of non returnable packer 8MM DIA and drill hole should be 10 MM dia for epoxy grouting .The item rate includes cleaning of the holes in position .with all equipment, putty, machinery, tools as recommended by the Manufacturer and directed by the Engineer-in-charge. |
| 508 | Providing & grouting with MONOPOL & KP 250/ HP250 injection grout: For cracks caused by structural distress such as shear cracks, flexural cracks, tensile cracks should be injected with low viscosity epoxy resin. The properties of injection resin complete all as specified and directed. |
| 509 | Drilling and fixing PVC nozzles and injecting epoxy cementious polymeric grout:In case it is noticed that the beams , columns or slab elements have honeycombing inside after removal of loose concrete material, it is necessary to inject POLYMER MODIFIED CEMENT GROUT in the honeycombed areas. Same methodology is used to inject construction joints. complete all as specified and directed. |
| 510 | M&L for providing rust proof /anti corrosive treatment to bars :-(i) cleaning of all exposed bars (new & old) alround(ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer(iii) Apply two coats of Epoxy phenolic anti-corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous especially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating. Area of reinforcement for which rust proof /anti corrosive treatment is applied is measured. |
| 511 | Supply and apply a cement-based epoxy modified three-component anti corrosive coating and bonding slurry for rebar corrosion protection system with following method.Surface preparation on concrete shall be free from dust, loose material, surface contamination and materials which reduce bond or prevent suction or wetting by repair materials. Delaminated, weak, damaged and deteriorated concrete toadhere necessary sound concrete shall be removed by suitable means. Substrate shall be Saturated Surface Dry (SSD) with no standing water. Steel reinforcement Rust, scale, mortar, concrete, dust, other loose and deleteriousmaterial which reduces bond or contributes to corrosion shall be removed by blast cleaning or other means of mechanical abrasion and reinforcement fully exposed and have all corrosion removed. Make:Friazinc R or Equivalent |
| 512 | M&L for providing Polymer modified cementitious mortar (PMM) as follows:-(i) Dry the sub strata surface and clean it free from debris & dust(ii) Apply Epoxy bond coat on the sound sub strate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 40 mm thickness.Note :Application of PMM shall be preferably be in coats of approx 10mm thickness. PMM work shall be executed in fairly rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use.(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed upto 16th floor |
| 513 | M&L for Micro concrete Rendroc RG (S) thickness not exceeding 40 mm for structural members all as per manufacturers instructions complete including leak proof form work coated with reabol mould release agent all as specified and directed including all necessary scaffoldingcomplete all as specified and directed. |
| 514 | All as per above item but from 5th Storey to 8th Storey |
| 515 | All as per above item but from 9th Storey to 12th Storey |
| 516 | All as per above item but from 13th Storey to 16th Storey |
| 517 | M&L for Additional Reinforcement for repair, rehabilitation work including main bar and stirrups: Supply and Providing extra reinforcement at the area where corrosion has gone above 25 % with proper over lapping. Supply of reinforcement steel and fixing using welding or lapping orDowel or Anchoring system on existing system and placing in position, at all heights & depths, of high strength deformed weld-able quality reinforcement bars of grade Fe415 or Fe 500 higher grade conforming to IS:1786 (latest version) as per drawings for RCC foundations, beam, column, slab and structures, straightening, cleaning, cutting, bending ,welding to required shape and length as per details, double binding wire with contractor\"s own 16 SWG black soft annealed binding wire, welding if required to form a rigid cage and placing with proper cover block, supports, chairs, spacers etc., complete as per instructions.HYSD bars of Fe 415 or Fe 500 grade and other higher Grade may also be allowed. However, extra payment will not be made for different grade of reinforcement steel. Make :HILTI -HIT RE 500 POST INSTALLED REBAR or Equivalent (Rebar Insrting chemicals) complete all as specified and as directed. |
| 518 | All as per above item but from 5th Storey to 8th Storey |
| 519 | All as per above item but from 9th Storey to 12th Storey |
| 520 | All as per above item but from 13th Storey to 16th Storey |
| 521 | M&L for applying food grade epoxy coating treatment to water tank on inside surface after proper surface preparation, carry out cementitious injection grouting at leakage points using Plasticized expansive grout admixture, treatment of construction joints using polymer modified mortar prepared by using SBR Latex-screed modifier cum bonding agent, application of polymer modified vatta/ fillet at floor-wall junction prepared by using SBR, filling pipe cut-outs using Non shrink cementitious grout, application of one coat of epoxy/PU primer and two coats of Solvent free food grade epoxy resin coating @ 200 microns DFT in 2 coats etc. complete including all tools and tackles as per manufacturer’s specification. Food grade epoxy coating shall be having elongation 100%, Adhesive bond strength - > 1 Mpa, Pot life of 30 min @ 30 °C and cured film shall be non-toxic and shall meets the requirements of IS: 9833:1981. Note: The Contractor shall furnished 10 years warranty for the coating. Application shall be carried out by approved applicator of manufacture and as per recommended by manufacturer. Actual applied area of epoxy coating shall be measured for payment. |
| 522 | M&L for preparation of old painted woodensurface of any description not othrwise described over 10cm width or girth and applying two coats of synthetic enamel paint upto 4 th storey complete all as specified and directed. |
| 523 | All as per above item but from 5th Storey to 8th Storey |
| 524 | All as per above item but from 9th Storey to 12th Storey |
| 525 | All as per above item but from 13th Storey to 16th Storey |
| 526 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed.. Make: CAT No. ALD-CHR-577 of Jaqar or its equivalent as approved by GE |
| 527 | S&F Glass shelf of size 600x100 mm near WHB with chromium platedsupport brackets upto 16th storey complete all as specified and directed. |
| 528 | M & L for Cutting chases in brick wall , pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed. |
| 529 | Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation, etc., and getting out in Hard/dense soil.Complete all as specified and as directed. |
| 530 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thickin hard soil complete all as specified and as directed |
| 531 | Removing excavated soilto a distance execeeding 5.00 km but not exceeding15 km and depositing where directed at a level not exe 1.50 m above the starting point complete all as specified and as directed. |
| 532 | All as per above item but from 5th Storey to 8th Storey |
| 533 | All as per above item but from 9th Storey to 12th Storey |
| 534 | All as per above item but from 13th Storey to 16th Storey |
| 535 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in hard/ dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,complete all as specified and as directed |
| 536 | M&L for cement concrete Type C2 1:3:6 (40 mm graded stone aggregate) as in foundations, including rafts,footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 537 | S&F Rolled mild steel of grade Fe 410-W (Gde-E- 250) quality- A in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated complete all as specified and as directed. |
| 538 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confrming to I.S.1161-1979 Grade St.-240 and painted one shop coat of zink chromate primer paint(including preparation of surface) at Contractor\"s work shop before fabrication complete all as specified and as directed. |
| 539 | S & F of Roof trusses of Fe 410-W (Gde E-250) quality B (framed), trusses purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed. |
| 540 | M & L for Mild steel Plates (plain or chequered) of 10mm thick, square cut or notched (ordinary and counter sunk) forming holes, without any attachments as required all as specified and as directed. |
| 541 | S & F of Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut with diameter of shank 16 to 20 mm, but length of bolt exc 16cm but n.exc 22.5cm long all as specified and as directed. |
| 542 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 543 | S&F wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed. |
| 544 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 545 | S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 546 | S & F15 mm bore chromium plated 2 way bib taps with wall flange, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron or CPVC pipe or for brass ferrule. up to 16 th storey complete all as specified and as directed.Make: CAT No. OPP-CHR-15041PM of Jaquar or its equivalent as approved by GE |
| 547 | S&F chrome plated Corner Glass Shelf 150 x 150 mm with all required fittings all as specified and directed.Make: CAT No. ACN-CHR-1173 of Jaquar or its equivalent as approved by GE |
| 548 | S&F Readymade pully operated cloth drying system including 4 Aluminium pipes ,channel assembly, locking system ropes and fitted material 7 feet long (4 pipe set) complete all as specified and directed by Engineer-in-charge. Make : Easy dry or its equivalent make as approved by GE. |
| 549 | M&L for 18-20 mm Granite work jet black (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in, set in screed bed/bedding layer, 15 mm thick in CM 1:6complete including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshade complete all as specified and as directed. |
| 550 | All as per above item but from 5th Storey to 8th Storey |
| 551 | All as per above item but from 9th Storey to 12th Storey |
| 552 | All as per above item but from 13th Storey to 16th Storey |
| 553 | M&L for 18-20 mm Granite work jet black (table rubbed and polished) for wall lining (veneering to wall) 10mm thick in CM 1:3 and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 554 | All as per above item but from 5th Storey to 8th Storey |
| 555 | All as per above item but from 9th Storey to 12th Storey |
| 556 | All as per above item but from 13th Storey to 16th Storey |
| 557 | M & L for Marble Stone Slabs of 18 to 20 mm thick of Green Colour, Premium quality, as in Flooring, Treads and Risers of Steps, Landings of Staircase etc., with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, slabs shall be of design / pattern as directed, including inlays, borders, margins, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious joint filler to match the shade of the Slabs including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed.Note: Single stone slab shall be used for entire width of Steps, Risers & Landing etc. and joints shall match with the flooring. The edges of treads shall be bull nosed / half rounded. The edges of the treads and landings shall also be provided with three Nos of grooves. |
| 558 | All as per above item but from 5th Storey to 8th Storey |
| 559 | All as per above item but from 9th Storey to 12th Storey |
| 560 | All as per above item but from 13th Storey to 16th Storey |
| 561 | Surface excavation not exceeding 30 Cm deep and averaging 25Cm deep and getting out in soft/loose soil complete all as specified and as directed. |
| 562 | M&L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and leveled in layers not exceeding 15 cm thick, watering and ramming to a true surface all as specified and as directed. |
| 563 | M&L for 100mm thick PCC 1:2:4 type B- 2, (40mm graded aggregate) as in sub base of flooring/ hard standing all as specified and as directed. |
| 564 | M&L for sand filling under floors or in foundations below interlocking tiles path including watering and consolidation complete all as specified and as directed. |
| 565 | M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and no pigment complete all as specified and as directed. |
| 566 | Removing excavated soilto a distance execeeding 250 m but not exceeding500 m and depositing where directed at a level not exe 1.50 m above the starting point complete all as specified and as directed. |
| 567 | Removing of debris to out side the premises to a distance of 12 KM all as directed by Engineer in Charge. |
| 568 | Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation, etc., and getting out in soft/loose soil.Complete all as specified and as directed. |
| 569 | Demolition and breaking 150 mm dia., drain pipes (Salt glazed ware, AC or reinforced concrete set in cement mortar, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 M and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M as directed by the Engineer in Charge. |
| 570 | Demolition and breaking 200 mm dia., drain pipes (Salt glazed ware, AC or reinforced concrete set in cement mortar, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 M and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M as directed by the Engineer in Charge. |
| 571 | M & L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore complete all as specified . |
| 572 | M & L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 200 mm bore complete all as specified . |
| 573 | M&L 150 mm inner diameter with tolerance of +/- 2 mm double wall corrugated HDPE pipes in any length including necessary collars , fittings , fixtures , etc. laid in terenches complete all as specified and as directed. |
| 574 | M&L 200 mm inner diameter with tolerance of +/- 2 mm double wall corrugated HDPE pipes in any length including necessary collars , fittings , fixtures , etc. laid in terenches complete all as specified and as directed. |
| 575 | Removing excavated soilto a distance execeeding 1.5 km but not exceeding5.0 km and depositing where directed at a level not exe 1.50 m above the starting point complete all as specified and as directed. |
| 576 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and as directed. |
| 577 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4, finished even and smooth without using extra cement complete all as specified and as directed. |
| 578 | Demolition of reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 M and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M complete all as specified and as directed. |
| 579 | Precast cement concrete 1:2:4, type B1 (Using 20 mm graded stone aggregate) in landings, bed plates, pintle blocks, anchorage blocks, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 including necessary form work , complete all as specified and as directed. |
| 580 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 150 mm dia., of pipe complete all as specified and as directed. |
| 581 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 200 mm dia., of pipe complete all as specified and as directed. |
| 582 | M&L for Reinforced cement concrete type B1 1:2:4 (using 20 mm graded granite stone aggregate) cast in situ in lintels up to 1.5 M sqan, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering slightly complete all as specified and as directed. |
| 583 | Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 M and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 Mcomplete all as specified and as directed. |
| 584 | M&L for PCC 1:4:8 type D2(using 40 mm graded stone aggregate) in foundations, filling and mass concrete (for base of manholes) complete all as specified and as directed. |
| 585 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 but except stone complete all as specified and as directed. |
| 586 | Precast Reinforced Cement concrete Type B0 1:2:4 (Using 12.5 mm graded stone aggregate) in 50 mm thick Jallies or louvers including all mouldings complete and set in Cement Mortar 1:4 complete all as specified |
| 587 | M & L for dismantling of RCC Jallies of any thickness and disposal of unserviceable materials, debris and rubbish out side MD Land complete all as directed by the Engineer in Charge. |
| 588 | M&L for preparing newly plastered surfaces of walls and applying three coats of white wash up to4th storey complete all as specified and as directed |
| 589 | M&L for preparing old painted surfaces of walls and applying two coats of white wash complete all as specified and as directed |
| 590 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and as directed. |
| 591 | Taking down carefully by unscrewing from boards, TV Sockets, LAN sockets and Computer jack, etc. |
| 592 | Taking down unserviceable main switches, DBs, bus bars chambers any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and as directed. |
| 593 | Taking down unserviceablesingle pole and neutral enclosure with two pin and earth plug and socket any type/ any rating including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and as directed. |
| 594 | Taking down unserviceable sub-main wiring (any numbers of cable) withrigid steelconduits/PVC casing caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and as directed. |
| 595 | Taking down old / perished earth pits and making good the disturbed surface of complete all as specified and as directed. |
| 596 | Taking down after disconnection the Exhaust fans any make, model, size and typefrom its position complete with all the parts i.e. down rod, canopies, fan blades etc.complete all as specified and as directed. |
| 597 | Taking down after disconnection the ceiling fans any make, model, size and typefrom its position complete with all the parts i.e. down rod, canopies, fan blades etc.complete all as specified and as directed. |
| 598 | Taking down existingstorage type water heater of any capacity of any type and size by disconnecting from Power socket, carring out necessary repair and paintingincluding cleaning and inner water tank, removing of hard water deposites and connected back and refixing in original position including testing and commissioning complete all as specified and as directed. |
| 599 | Taking down after disconnectIon of existing electric meter any make model and type from wall complete all as specified and as directed. |
| 600 | Taking out after disconnectIon of existing LT panel any make model and capacity from the exisiting location with complete demolition of existing plinth/ foundation of LT panel including cleaning of site complete all as specified and as directed. |
| 601 | Taking down LED light fitting of any type complete all as specified and as directed. |
| 602 | M&L for point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (minimum) medium grade (ISI marked) surface fitted type including Flush type metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switchesincluding provision of multistranded 1.5 Sq.mm copper conductorcable FRLS (ISI marked) as earth wire connected to common earth dolly and earth in distribution board for one light/exhaust fan/fan point/call bellcontrolled by one way switch complete all as specified and as directed.Note:- The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface |
| 603 | All as per above item but for One light Point controlled by 2- Way Switch complete all as specified and as directed. |
| 604 | All as per above item but for one 5 Amps socket independent including 1.5 Sqmm earth continuty FRLS Copper Cable complete all as specified and as directed. |
| 605 | All as per above item but for one 5 Amps socket on the same board including 1.5 Sqmm earth continuty FRLS Copper Cable complete all as specified and as directed. |
| 606 | All asper above item but with 2.5 SqmmFRLS copper cable for one 15/5 Amps Multipurposepower point.Including 2.5 Sq mm FRLS copper conductor cable for earth continuity conductor and connecting it to earth complete all as specified and as directed. |
| 607 | All as per above item but with 4.0 SqmmFRLS copper cable for one geyser/AC point including 4.0 Sq mm FRLS copper conductor cable for earth continuity conductor and connecting it to earth complete all as specified and as directed. |
| 608 | S&F TV Socket outlet with metal box complete all as specified and as directed. |
| 609 | S&F switch Modular type single pole 6 Amps One WayAC 230V, 50HZ complete all as specified and as directed. |
| 610 | S&F switch Modular type single pole 6 Amps Two WayAC 230V, 50HZ complete all as specified and as directed. |
| 611 | S&F Bell Push Modular type single pole 6 AmpsAC 230V, 50HZcomplete all as specified and as directed. |
| 612 | S&F Modular type socket5AAC 230V, 50HZ complete all as specified and as directed. |
| 613 | S&F Modular type switch 16A AC 230CV, 50Hz complete all as specified and as directed. |
| 614 | S&F Modular type Socket 6A/16A multi purpose AC 230CV, 50Hz complete all as specified and as directed. |
| 615 | S&FModularFan regulator,step type 120W - 2 module complete all as specified and as directed. |
| 616 | S&F Celing rose surface backlite 63 mm dia two to three terminals complete all as specified and as directed. |
| 617 | S&F Buzzer, Ding Dong AC. 230 Volts, single pole complete all as specified and as directed. |
| 618 | S&F Single pole and neutral enclosure with two pin and earth plug and socket with 20 Amps MCB SP complete all as specified and as directed. |
| 619 | M&L Sub main wiring with 2 runs of 2.5 Sqmm PVC insulated FRLS Copper conductor cable including PVC conduit of Suitable along with one run of 2.5 Sq.mm FR copper cable for earth continuity conductor as earth lead for sub main wiring and connecting to common earth dolly complete all as specified and as directed. |
| 620 | M&L Sub main wiring with 2 runs of 6.0 Sqmm PVC insulated FRLS Copper conductor cable including PVC conduit of Suitable along with one run of 6.0 Sq.mm FRLS copper cable for earth continuity conductor as earth lead for sub main wiring and connecting to common earth dolly. (TPN to SPN DB) complete all as specified and as directed. |
| 621 | S&F TPN DB 4 Way with 415 Amps rated bus bar Double Door complete all as specified and as directed. |
| 622 | S&F 415 V, 10 kA \"C\" curve miniature circuit breaker (MCB) of Three poles and Netural current carrying capacity 63 A in the MCB DB complete all as specified and as directed. |
| 623 | S&F SPN DB 12 Way with 200 A rated bus bar Double Door complete all as specified and as directed. |
| 624 | S&F 240 V, 10 kA \"C\" curve miniature circuit breaker (MCB) of single poles and Netural current carrying capacity 32 A, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed. |
| 625 | S&F 240V, 10 kA \"C\" curve miniature circuit breaker (MCB) of single poles, current carrying capacity 6 to 32 A, in the MCB DB Complete with connection testing and commissioning. |
| 626 | S&F LED lights fitting 1x 20 W, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 627 | Fixing only LED tube light fitting any Watt any make and model, obtained from taking down and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 628 | S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 629 | Fixing only LED mirror light fitting any watt any make and model, obtained from taking down above, 220V, ACand connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 630 | S&F LED light fitting 1x9/1x10 Watt bulk head luminiare including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 631 | Fixing only bulk head luminiare any watt any make and model, obtained from taking down above, 220V, ACand connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 632 | S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 633 | Fixing only LED lights fitting building security light incl all fixing arrangement obtained fromtaking down above, 220V, ACand connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 634 | S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 635 | Fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 636 | S&F in repairs LED Bulb, 9 Watts Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, complete all as specified and as directed. |
| 637 | S&F Rigid non-metalic PVC conduit (20mm dia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and as directed. |
| 638 | S&F Aviation obstruction light of LED type integral light comprising of aluminium housing with polycarbonate enclosure,302 nos LED are provided along with other fixing aceessories internal prewired and including taking down existing light fittings of any complete all as specified and as directed Make : Bajaj Cat No BGAV 302 LEDor equialent in Crompton or Philips |
| 639 | S&F PVC body exhaust fan 250 mm sweep AC single phase 1200 RPM complete with accessories electric connection including making necessary holes in walls complete all as specified and as directed. |
| 640 | Fixing only exhaust fan of any Make, model, sweep and type includingover hauling, servicing, painting with two coats of enamel paint including re-fixing the fan at new/old location complete all as specified and as directed. |
| 641 | Fixing/ Hanging only Ceiling fan of any make, model, sweep and type including connecting up including provision of cable from ceiling rose/connector to fan painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and as directed. |
| 642 | Scrapping and painting with two coats of synthetic enamel paint over a coat of primer on existing MS Box of size 900x600x150mm inside the wall for fixing of DBs and meter complete all as specified and as directed. |
| 643 | S&F in repairs stationery louvers suitable for exhaust fan of 300 mm sweep made out of powder coated aluminium anodized sheet of minimum 1 mm thick with non removable blades fixed permanently at 45 degree angle for protection from rain including aluminium wire mesh for protection of birds complete all as specified and as directed. |
| 644 | S&F XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 4 core 16 Sqmm from ground floor indoor panel to TPN DBs at each floor complete all as specified and as directed. |
| 645 | S&F GI Tube light grade 40 mm dia with all fittings fixed to walls and ceiling or laid in floors for cable protection complete all as specified and as directed. |
| 646 | LT Cubical Panel board CPRI approved made out of CRCA sheet 2.0 mm thick indoor Compartmenatal Type totally enclosed , Dust and vermin proof with front opening, hinged doors with projected raised platform of suitable size with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc made of rust proof material including all as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 630 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following :-Incoming:(a)MCCB AC 3 Phase 415 V, 50Hz 4 pole, 400 A, breaking capactiy 36kA, Ics=100% Icu with adjustablethermal and fixed magnetic setting relays - 01 No.Outgoing:(a)MCCB AC 3 Phase,415 V, 50Hz 4 pole, 63 A breaking capacity 10 kA with adjustable thermal and fixed magnetic setting relays - 13 Nos. (b) MCB SPN 20 Amp-02 Nos(c) Multi function meter with all connected CTs-01 Set(d) LED indicating lamps with colour Red, Yellow, Blue - 03 Sets |
| 647 | M&L for Earthing complete with galvanizedsteel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI strip 32x6mm (up to 7.5 m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode 20 mm dia for watering complete all as specified and as directed and tested on completion including taking down of existing earthings. |
| 648 | S&F Hot dip Galvanised Cable tray of size 75mm depth, 300mm width and 2mm thick (14 SWG) and standard length for fixing to wall including tee, cross, horizontal/vertical bends and reducer as required for fixing or arrangement of cables in side the cable tray with zip ties such as electrical cable after taking out of cables from existing conduits of any make and sizes and making good the disturbed surfaces to match with existing surfaces complete all as specified as and directed. Make: MEM/OBO/Legrand |
| 649 | S&F Galvanised iron Coupler plate of size 75mm including necessary hardware work complete all as specified and as directed. Make: MEM/OBO/Legrand |
| 650 | Taking down ofAluminium strip/ GI Strip of lightning conductor having any size and dimension (roof conductors)/down conductors) laid in trench/floor including taking down of clamps,nuts,bolts complete all as specified and as directed. |
| 651 | Taking down of Air termination, single pointed aluminium rod of any size complete all as specified and as directed. |
| 652 | S&F Aluminium strip of size 25x3.15 mm for lightning conductor (roof conductors)/down conductors) laid in trench/floor including necessery clamps, nuts, bolts and hylem sheet block complete all as specified and as directed. |
| 653 | Fixing only Aluminium strip of size 25x3.15 mm for lightning conductor (roof conductors)/down conductors) laid in trench/floor including necessery clamps, nuts, bolts and hylem sheet blockcomplete all as specified and as directed. |
| 654 | S&F Air termination, single pointed aluminium rod 12mm dia and 300mm long and fixed complete all as specified and as directed. |
| 655 | Fixing only of Air termination, single pointed aluminium rod 12mm dia and 300mm long and fixed complete all as specified and as directed. |
| 656 | S&F test terminal box of size 175x150x100mm made out of 2mm thick hot dip galvanised sheet drilled and screwed including 4 nos 125mm long hexogonal head screwed with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed. |
| 657 | S&F GI strip of size 32x6mm for lightning conductor laid in trench / floor including necessery clamps, nuts, bolts,insulator and hylem sheet block complete all as specified and as directed. |