| 1 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover filllets complete all as specified and as directedby Engr-in-charge. |
| 2 | S&F of elegant perforated cement fibre composite tile 595x1195x5mm as in ceiling with square edge density 1050kg/m3 covered with absorbtive microfiber coating on the front side and Acoustics fibre on the back side with a backing of 50mm 1000 GSMthick absorb wool tested as per Fire Retardant IS15061-2002 for excellent results, thus making it acoustically absorbtive, water resistance, fire resistant as per IS1734 of absorption coefficient 0.71 at 100 Hz tested as per ISO 354. The tiles are anti sag and are to be installed on T24 grid system of 0.6mm thick, main \"T\" length minimum 3000mm, web minimum 35mm to be placed at 600mm centre to centre and secondary cross \"T\" of length 600mm, web minimum 27mm inter locked, 6mm dia GI wire suspenders with adjustable hook wire support for main T to be taken at every 1200mm length wise and 600mm width wise, specially designed for Acousic vibration management and long life complete all as specified and directed by Engr-in-Charge |
| 3 | M&L for Fibrette Tile made of \"Wood fiber Cement Composite\"1mm width wood fiber 15mm thicksize 595x595/ 595X1195 mm having excellent noise absorption of1 NRC as per ISO: 354, Density 400 Kg/ m3, meetsFire Ratings as per BS 476 Part 5, 6 and 7 class 1and P, water resistant and thermal insulated.Installed on T24 grid system of 0.6mm thick Main\"T\" length minimum 3000mm, webminimum 35mmto be placed at 600mm center to center andsecondary cross \"T\" of length 600mm web minimum35mm inter locked, Wire Support for Main T to betaken at every 1200mm length wise and 600mmwidth wise, with a backing of 50mm 1000 GSMthick absorb wool tested as per Fire Retardant IS15061-2002 for excellent results complete all as specified and directed by Engr-in-Charge |
| 4 | S&F elegant Tile made of perforated cement fibercomposite wall tiles of size 595x595/295X1195/595X1195x5mmcovered with absorptive microfiber coating on thefront side and Acoustics fiber on the back side,waterresistance, fire resistant absorption coefficient upto0.89 at 160 Hz tested as per ISO 354. The tiles areanti-sag and installed on T24 grid system of 0.6mmthick Main \"T\" length minimum 3000mm, webminimum 35mm to be placed at 600mm center tocenter and secondary cross \"T\" of length 600mmweb minimum 35mm inter locked, Wire Support forMain T to be taken at every 1200mm length wiseand 600mm width wise, with a backing of 50mm1000 GSM thick absorb wool tested as per FireRetardant IS 15061-2002 for excellent results complete all as specified and directed by Engr-in-Charge |
| 5 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed . |
| 6 | S & F EURO GUARD PRO SQUARE UPVC RAINWATER GUTTER (220 MM),with all necessary fittings, 20x3mm size flat iron clamp, welding,joints, end cap, corner drop, centre drop, etc joining compounds, nut, bolts or screws etc and fixing in position, at any height complete all as specified andas directed. |
| 7 | S & F 150 mm borePVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls(jointing shall be done with solvent cement) complete all as specified andas directed . |
| 8 | S & F PVC (SWR) bends, any radius, 150mm bore all as specified,complete all as specified andas directed . |
| 9 | Taking down cement plastered on Brick/Concrete wall and ceiling including racking out joints, hacking for key, scrubbing down with watercomplete all as specified and as directed by Engr-in-Charge. |
| 10 | Supply, mixing and application two component structural grade polymer modified reinstatement mortar, where local spalling has taken place or shuttering is not possisble(As in roof Facia, parapet, chajja, ceiling, etc).Themortar can be applied in layers not exceeding 6 mm thick in each layer in and upto 25mm thickness in smaller vertical pockets and upto any thickness in horizontal applications.The mortar should have a minimumcompressive strength 12Nmm2in 1 day and 45N/mm2 in 28 days.Minimum flexural strength shouldbe8 N/mm2 in 28 days.A modified styrene butadience emulsion for use as a bonding aid and gauging liquid for cementious system to be mixed with cement slurry before the application of microconcrete to be used @ 6ltr/bag of cement.The bonding agent should have minimum compressive strength 24 N/mm2.Minimum tensile strength 3.5N/mm2, minimim flexural strength 6.5N/mm2with and including curing comopund LP 90 or equivalent complete all as specified and directed by the Engr-in-Charge.Make:- Dr. Fixit/ Sika/Fosroc |
| 11 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including 1 to 1.5mm thick exterior wall care putty and priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 12 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof covering complete all as specified and as directedby Engr-in-charge. |
| 13 | S&F Pre-painted galvalume aluminum zink coating GI based corrugated steel sheet 0.55 mm over all thick and AZ 150, on an colour, having tensil strength of 550 Mpa as in roof fixes with self tapping screws all as specified and as directed by Engr-in-Charge. |
| 14 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.55 mm over all thick and AZ 150 of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 15 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 16 | Material and labour for point wiring for one light/fan point with 1.5 sqmm PVC insulated (FRLSH) unsheathed copper conductor multistranded 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FRLSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity conductor including connected to common earth dolly drawn through and including rigid PVC conduit medium grade ISI marked concealed of suitable size with all accessories and sunken box of 1.6 mm thick and 60 mm depth pressed steel box factory made for mounting of switch, socket and fan regulator with modular frames covers including chase cutting and making good to the disturbed surface and matching to the existing finishes specifications complete all as specified and as directed by the Engr-in-Charge. |
| 17 | All as per item No. 16 here in before but for one 3/5 pin 5 Amp socket outlet point on independent board complete all as specified and directed. |
| 18 | All as per item No. 16 here in before but for one 5 pin 5 Amp socket outlet point on same board complete all as specified and directed. |
| 19 | All as per item No. 16 here in before but using with 2.5 sqmm copper conductor cables multistranded (FRLSH) PVC insulated, unsheathed cable and including 2.5 Sqmm copper conductor cable multistranded (FRLSH) PVC insulated and unsheathed cable as earth continuity wire and connecting to common earth dolly for one 6 pin 15 AMp socket outlet point on independent board complete all as specified and directed. |
| 20 | Supply and fixceiling rose surface bakelite 65 x 50 mm 3 terminals 240 volt 50 Hz complete all as specified and directed. |
| 21 | S&F in modular type sockets 6 Amp-2/3 pin combined 2 module complete all as specified and directed. |
| 22 | S&F inswitch modular type single pole, 6 Amps, one way all as per specified & directed. |
| 23 | S&F inmodular sockets 6 Amp/16 Amps, 2/3 pin combined 2 module complete all as specified and directed. |
| 24 | S&F in switch modular type 1 module, 16 Amps, one way all as per specified and directed. |
| 25 | S&Fmodular fanstep regulator 120 W,2 module complete all as specified and as directed. |
| 26 | S & F LED luminaire 600x600mm 35/36W 220V AC recessed type with high efficiency PMMA diffuser glare free light for roof ceiling incl conneciting up with driver three core cable of copper conductor complete all as specified and as directed. |
| 27 | S & F LED flood light 70W 230V, AC outdoor/indoor type with thermal management in multiple opticles and equiped with IP 66 protection with impact and corrision resistant complete with driver and lamp complete all as specified and as directed. |
| 28 | Taking down fan, ceiling cable end, dismantling blades and removing fan and blade to store all as specefied and directed by engr in charge . |
| 29 | Fixing only ceiling fan MD supply any size and connecting up incl provn of cable from ceiling rose or connector to fan complete all as specified and as directed. |
| 30 | Fixing only Exahust fan MD supply any size and connecting up incl provn of cable from ceiling rose or connector to fan complete all as specified and as directed. |