Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORK TYPE BEarth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.all kinds of soil |
| 2 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 3 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Making R.C.C. apron Drain with apron (analysis). |
| 5 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 6 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttring, finishing and reinforcement as per direction of the engineer-in-charge, for thr following grades of concrete above Plinth level concrete of M25 grade with minimum cement content of 330 kg /cum Lintel |
| 7 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttring, finishing and reinforcement as per direction of the engineer-in-charge, for thr following grades of concrete above Plinth level concrete of M25 grade with minimum cement content of 330 kg /cum.Slab. |
| 8 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttring, finishing and reinforcement as per direction of the engineer-in-charge, for thr following grades of concrete above Plinth level concrete of M25 grade with minimum cement content of 330 kg /cum.Beam |
| 9 | As in item abovebut inR.C.C.Raft foundation and footingwithapproved stone ballast.(Using1:1.5:3Mix concrete) Foundation & raft |
| 10 | As in item above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) 345 mm thick |
| 13 | Same As Above but for F.F. |
| 14 | Same As Above but for S..F. |
| 15 | Same As Above but for T..F. |
| 16 | Same As Above but for MUMTY |
| 17 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 18 | Same As Above but for F.F. |
| 19 | Same As Above but for S..F. |
| 20 | Same As Above but for MUMTY |
| 21 | Providing and laying integral cement based water proofing treatment including preparationof surface as required for treatment of roofs, balconies, terraces etc consisting of followingoperations:(a) Applyinga slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoiningwallsupto300mm heightincludingcleaning the surface before treatment.(b) Layingbrickbatswithmortarusing broken bricks/brickbats25mmto115mmsizewith50%of cementmortar1:5(1cement: 5 coarsesand)admixed with water proofingcompoundconformingto IS : 2645 andapprovedbyEngineer-in-chargeover20mmthick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixedwith water proofing compoundconformingto IS : 2645 and approved by Engineer-in-chargeto required slope and treating similarly the adjoining walls upto 300 mm height includingroundingof junctionsof walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofingcompoundconformingto IS : 2645 and approved by Engineerin- charge.(d)Finishingthesurfacewith20mmthickjointless cementmortarofmix1:4(1cement:4coarsesand) admixed with water proofing compound conforming to IS:2645andapprovedbyEngineerin-chargeincluding laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neatcementslurryandmakingpatternof 300x300mm square 3 mm deep. (e) The wholeterraceso finishedshallbe floodedwith water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 22 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 23 | Supply and fixingof30 mm thickflushdoors commercialqualityconformingtoI.S.2202 Part I (1983) includingfixingof woodencleats andstoppers and including ixing andadjustment of hinges, bolts,locks, handle, springs and other fittings with necessaryscrews to be supplied departmentally. & Providing & Fixing both side decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick |
| 24 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Kiln seasoned and chemically treated hollock wood |
| 25 | Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge |
| 26 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Holdfastfordoor chaukhats and windows. |
| 27 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 28 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 29 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 30 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete With 2nd class teak wood beading 62X19 mm |
| 31 | Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :25 mm dia |
| 32 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (a) Door chaukhats |
| 33 | Same as above but Window chaukhats up to 1.5 sqm |
| 34 | Same as above but Ventilator chaukhats |
| 35 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 36 | 15 mm thick plaster in 1:4 cement & course sand on outer wall below Ground level & inner wall below plinth level in 15 cm width. |
| 37 | 12 mm cement plaster of mix :1 cement : 6 c. sand |
| 38 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) 1 cement : 6 c. sand |
| 39 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 40 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 41 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (40 mm flooring) |
| 42 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 43 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. |
| 44 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 45 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 46 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 47 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 48 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 49 | Same as itemabovebutonnew wood surface. |
| 50 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 51 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 52 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes |
| 53 | Providing & fixing Oxidied iron door bolts ISI marked required colour or shade with nuts and screws etc complete.250x16 mm |
| 54 | P/Fixing Oxidied iron tower bolts ISI marked to required colour or shade with necessary screws etc complete.250x10 mm |
| 55 | Providing and fixing Oxidied iron handles ISI marked to required colour or shade with necessary screws etc complete. 125mm |
| 56 | Supply and filling of cinder in sunken in portion of building including breaking into required sizes including supply of all material, labour T&P required for proper completion of the work. |
| 57 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) |
| 58 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Foundations, footings, bases of columns, etc. for mass concrete. |
| 59 | Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick. |
| 60 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick |
| 61 | Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 62 | ELECTRICAL TYPE BAll wiring Item FRLS including provision of conduit, conduit accsories , circuit wiring, switch, box and all fitting completed as required. Wiring for light point / fan point /exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with modular switch,modular plate ,suitable GI Boxand earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 63 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper condutor single core cable in surface / recessed PVC conduit 2 way modular switch,modular plate,suitable GI box and earthing the point with 1.5 sq.mm .FRLS PVC insulated copper conductor single core cable etc as required. |
| 64 | Wiring for light /power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed PVC conduit along with 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 65 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface/recessed PVC Conduit as required.2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 66 | Same as above but 2x2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 67 | Same as above but2 x 4 sq.mm + 1 x 4 sq.mm earth wire |
| 68 | Same as above but2x6 sq.mm + 1x6 sq.mm earth wire |
| 69 | Supplying and fixing modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 5/6 amps switch |
| 70 | 3 pin 5/6 amps socket outlet |
| 71 | Supplying and fixing of following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 Module (100mmx75mm) |
| 72 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 and 5/6 amps modular socket outlet with shulter and 15/16 amps modular switch connection,etc as required. |
| 73 | Supplying and fixing call bell/ buzzer suitable forsingle phase ,230 volts ,complete as required. |
| 74 | Supplying and fixing of following sizes of medium class PVC conduit along with acessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 75 | Same as abvoe 32 mm |
| 76 | Supplying and fixing 20 amps, 240 volts SPN industrial type, socket outlet with 2 pole and earth metal enclosed plug top along with 20 amps \"C\" Curve, SP, MCB in sheet steel encloser on surface or in recess with chained metal cover for the socket outlet and complete with conncections, testing & commissioning etc as required. |
| 77 | SUB-HEAD II:- DISTRIBUTION BOARDSSupplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)8 way (4+24) Double door |
| 78 | Supply and fixing 5 amps to 32 amps rating.240/415 volts.\"C\" curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commisioning etc.as required Single pole |
| 79 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 80 | Supply, installation, testing and commissioning of electrical pane, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.2mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB\"s to be used. All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows :Phase to phase - minimum 20mm Phase to neutral-minimum 15mmL.T.PANELIncoming :One (1) No 200 A 4 pole Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No.200 A, TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.100Amps TPN- 1No.63Amps TPN-3Nos OR outgoing as per site requirment |
| 81 | Supplying and fixing of following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.) 75 mm x 75 mm x 60 mm deep |
| 82 | Supplying and drawing following pair, 0.5.mm dia FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 83 | Earthing with G.I earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr longetc.with charoal or coke and salt as required. |
| 84 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 85 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 86 | Supply and fixingof LED Tube Lightwith batten suitablefor up to 1 X 22 watt LED tube light complete includingtube etc on surface complete in all respect. CAT-AA |
| 87 | c) 18W LED Tubelight |
| 88 | Supply and fixing of exhaust fan complete including etc on wall surface complete in all respect. CAT-AA |
| 89 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/MIW) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THO less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required1200 mm sweep |
| 90 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 91 | Installtion of exhasut fan up to 450 mm sweep in the existing opening, including making the hole to suit the size of the abvoe fan, making good the damage, connection testiing and commissioning etc as requried |
| 92 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 93 | PLUMBING WORK TYPE BProviding and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fitting and fixtures completed including cutting and making good the walls and floors wherever required.White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests |
| 94 | Providing & fixing white viterous china wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standardpattern, including painting of fitting and brackets, cutting & making good the walls wherever required .Flat back Wash Basin size 550X400 mm with single 15mm C. P. brass pillar tap |
| 95 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete32 mm dia (for wash basin) |
| 96 | Providing & fixing stainless steel AISI 304 (18/8) kitchen sink without drain board as per IS :13983 with C.I. bracketsandstainless steel plug 40 mm including painting of fittings and brackets cutting and making good the walls wherever required.610x510 mm bowl depth 200 mm |
| 97 | Providing & Fixing 600 X 450 mm bevelled edge mirror of superiorglass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 98 | Providing & fixing viterous china toilet paper holder. |
| 99 | S/F of upvc SWR Nahani Trap size100/90mm confirming to IS -14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali.110mm dia |
| 100 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 101 | Providing and fixing of Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, inluding fixing the pipe with clamps at 1 m. spacing . This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal work exposed on wall.Internal work exposed on wall20mm nominal outer dia pipes |
| 102 | Providing and fixing of Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, inluding fixing the pipe with clamps at 1 m. spacing . This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal work exposed on wall.Internal work exposed on wall32mm nominal outer dia pipes |
| 103 | Providing and fixing of Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, inluding fixing the pipe with clamps at 1 m. spacing . This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal work exposed on wall.Internal work exposed on wall40mm nominal outer dia pipes |
| 104 | Providing and fixing of Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, inluding fixing the pipe with clamps at 1 m. spacing . This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal work exposed on wall.Internal work exposed on wall50mm nominal outer dia pipes |
| 105 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(internal work)Exposed on wall 32mm dia nominal outer dia pipes |
| 106 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(internal work)Exposed on wall 25mm dia nominal outer dia pipes |
| 107 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. 15mm dia nominal outer dia pipes |
| 108 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.) 20mm dia nominal outer dia pipes |
| 109 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. 25mm dia nominal outer dia pipes |
| 110 | Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end)32 mm nominal bore |
| 111 | Providing and fixing ballvalve (brass) of approved quality complete. (High or low pressure with plastic floats).25 mm nominal bore |
| 112 | Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions. |
| 113 | Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. |
| 114 | Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms. |
| 115 | Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931. |
| 116 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : |
| 117 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design150 x 100 mm size P typeWith Brick M-150 |
| 118 | CIVIL WORK TYPE AEarth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out |
| 119 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 120 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 121 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 122 | Making R.C.C. apron Drain with apron (analysis). |
| 123 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm |
| 124 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the |
| 125 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the |
| 126 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the |
| 127 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 128 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 129 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 130 | Same As Above but for MUMTY |
| 131 | including preparationof surface as required for treatment of roofs, balconies, terraces etc consisting of followingoperations:(a) Applyinga slurry coat of neat cement using 2.75 kLayingbrickbatswithmortarusing broken bricks/brickbats25mmto115mmsizewith50%of cementmortar1:5(1cement: 5 coarsesand)admixed with water proofingcompoundconformingto IS : 2645 andapprovedbyEnginee After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofingcompoundconformingto IS : 2645 and approved by Engineerin- charge.(d)Finishingthesurfacewith20mmthick The wholeterraceso finishedshallbe floodedwith water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 132 | Supply and fixingof flushdoors commercialqualityconformingtoI.S.2202 Part I (1983) includingfixingof woodencleats andstoppers and including ixing andadjustment of hinges, bolts,locks, handle, springs and other fittings with necessaryscrews to be supplied departmentally35 mm thick |
| 133 | Supply and fixingof32 mm thickflushdoors commercialqualityconformingtoI.S.2202 Part I (1983) includingfixingof woodencleats andstoppers and including ixing andadjustment of hinges, bolts,locks, handle, springs and other fittings with necessaryscrews to be supplied departmentally. & Providing & Fixing both side decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick |
| 134 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 135 | Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per directionof the Engineer-in-Charge |
| 136 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding (hold fast) |
| 137 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 138 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 139 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 140 | Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :25 mm dia |
| 141 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded sto Door chaukhats |
| 142 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded sto Window chaukhats up to 1.5 sqm |
| 143 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded sto Ventilator chaukhats |
| 144 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 145 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand) |
| 146 | 12 mm cement plaster of mix : (1)1 cement : 6 c. sand |
| 147 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:61 cement : 6 c. sand |
| 148 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 149 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 150 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (40 mm flooring) |
| 151 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm |
| 152 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement m |
| 153 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, ofapprovedmake,inallcoloursandshades,laidon 20mm thick cemen |
| 154 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 155 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 156 | Same as itemabovebutonnew wood surface. |
| 157 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 158 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and includ |
| 159 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : With 4.0 mm thick glass panes. |
| 160 | Providing & fixing stainless steel sliding door bolts ISI marked required colour or shade with nuts and screws etc complete. |
| 161 | P/Fixing stainless steel tower bolts ISI marked to required colour or shade with necessary screws etc complete. |
| 162 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. |
| 163 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick. |
| 164 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick |
| 165 | PLUMBING WORK TYPE AProviding and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fitting and fixtures completed including cutting and making good the walls and floors wherever required.White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests |
| 166 | Providing & fixing white viterous china wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standardpattern, including painting of fitting and brackets, cutting & making good the walls wherever required .Flat back Wash Basin size 550X400 mm with single 15mm C. P. brass pillar tap |
| 167 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete32 mm dia (for wash basin) |
| 168 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete40 mm dia(for sink and urinal) |
| 169 | Providing & fixing stainless steel AISI 304 (18/8) kitchen sink without drain board as per IS :13983 with C.I. bracketsandstainless steel plug 40 mm including painting of fittings and brackets cutting and making good the walls wherever required.610x510 mm bowl depth 200 mm |
| 170 | Providing & Fixing 600 X 450 mm bevelled edge mirror of superiorglass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 171 | S/F of upvc SWR Pipe Type -B confirming to IS -13592 incluiding jointing the pipes with rubber ring lubricant and UPVC SWR Cuplar confirming to IS 14735 also inluiding excavation of treches cutting of walls and holes and repairing of walls , floors and refilling the trenches as before cut including cost of other fittings such as door band, T and YT including supply of all materials labour and t&p required for prper complition of the work.110mm dia SWR Pipe |
| 172 | 90mm dia SWR Pipe |
| 173 | S/F of upvc SWR Nahani Trap size100/90mm confirming to IS -14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali.110mm dia |
| 174 | Providing & fixing upvc SWR door bend confirming to IS -14735110mm dia |
| 175 | Providing & fixing upvc SWR bend confirming to IS -14735110mm dia |
| 176 | Providing & fixing upvc SWR door bend confirming to IS -14735110mm dia |
| 177 | 75 mm dia |
| 178 | Providing & fixing upvc SWR door Y confirming to IS -14735110mm dia |
| 179 | Providing & fixing upvc SWR door Y confirming to IS -1473575mm dia |
| 180 | Providing & fixing of upvc SWR cowel confirming to IS -14735110mm dia |
| 181 | Providing & fixing of upvc SWR cowel confirming to IS -1473575 mmdia |
| 182 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 183 | Providing and fixing of Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, inluding fixing the pipe with clamps at 1 m. spacing . This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal work exposed on wall.Internal work exposed on wall20mm nominal outer dia pipes |
| 184 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(internal work) Exposed on wall 32mm dia nominal outer dia pipes |
| 185 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(internal work) Exposed on wall25mm dia nominal outer dia pipes |
| 186 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. 15mm dia nominal outer dia pipes |
| 187 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.) 20mm dia nominal outer dia pipes |
| 188 | c) 25mm dia nominal outer dia pipes |
| 189 | Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 25 mm nominal bore |
| 190 | Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 32 mm nominal bore |
| 191 | Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 50 mm nominal bore |
| 192 | Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 65 mm nominal bore |
| 193 | Providing and fixing ballvalve (brass) of approved quality complete. (High or low pressure with plastic floats).25 mm nominal bore |
| 194 | Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions. |
| 195 | Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. |
| 196 | Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms. |
| 197 | Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931. |
| 198 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and makingnecessaryholes for inlet, outlet and overflow pipes but without fittingandbasesupportfor tank.500 litres capacity |
| 199 | Providing450 mm long C. P. brass towel railcomplete with C.P. brass brackets |
| 200 | Fixing of C. P. brass towel rail |
| 201 | Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. |
| 202 | Providing & fixing of hand lever operated forged brass full way ball valve type isolating valve having screwed ends tested to a pressure of 15 kg/sqcm complete. (Make : CIM)20 mm nominal bore |
| 203 | ELECTRICAL WORK TYPE AWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. DSR 2022 Item No.1.10.2 |
| 204 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.DSR 2022 Item No.1.11 |
| 205 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as require2 x 2.5 sq. mm + 1 X 2.5 sq. mm earth wire S.I.No.1.14.2 |
| 206 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as require2 x 4 sq. mm + 1 x 4 sq. mm earth wire S.I. No. 1.14.3 |
| 207 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as require4 x 10 sq. mm + 2 x 6 sq. mm earth wire S.I. No. 1.14.10 |
| 208 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required DSR 2022 S.I. No. 1.31 |
| 209 | Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. DSR 2022 S.I. No. 1.32 |
| 210 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. DSR 2022 S.I. No. 1.33 |
| 211 | Supplying and fixing brass batten/ angle holder including connection etc. as required. DSR 2022 S.I. No. 1.34 |
| 212 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required DSR 2022 S.I. No. 1.38 |
| 213 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required40 A SI No. 2.13.1 |
| 214 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etSingle pole |
| 215 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powdr painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door |
| 216 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required DSR 2022 SI no. 2.11 |
| 217 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. DSR 2022 SI No. 2.21 |
| 218 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) DSR 2022 SI No. 5.9 |
| 219 | Supply and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required :20 mm. DSR 2022 SI no 1.21.1 |
| 220 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required2 pair |
| 221 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. SI 1.19 |
| 222 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as requireTelephone/TV socket outlet |
| 223 | Supplying and fixing following size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required1 or 2 Module (75 mmX75 mm) |
| 224 | Supplyand burring of safe Earthing ElectrodeT – 19 (Hot Dip Galvanized) Length 3000 mm outer pipe 50 mm inner pipe 25 , terminal Dia 12 mm outer G.I. pipe of 16 swg and inner G.I. pipeof 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover and masonry housing P.W.D.S.O.R. 2018 S.I. No.725 B |
| 225 | Supply & laying of aluminium conductor PVCinsulatedarmoured served sheathed cables 1100 Volts grateata depthofbelowground level over a cushion of 75mm. below groundlevel over a cushion of 75mm. thicksand alround and protected with burnt bricks on sides and on top.On surface the cable run shallbefixedonM.S. clamps etc. ofsuitablesizeorasdirectedby the Engineer-incharge, complete in all respects. The armouring of thecable shall be properly connected with the earth conductor by clamps etc. 50 sq. mm 3-1/2 core |
| 226 | Supply & Fixing of Brass nickle plated compression gland for PVC insulated and around served sheathed underground cable including rubber ring etc complete in all respec50 sq. mm 3-1/2 core |
| 227 | Supply & fixing of plain or pin type copper tin plated cable socket (lug)to the cable leads,insulated with tapeand making connection etc.complete in all respectas per direction25 Sqmm |
| 228 | Supply & fixing of plain or pin type copper tin plated cable socket (lug)to the cable leads,insulated with tapeand making connection etc.complete in all respectas per direction50 sqmm |
| 229 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/MIW) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THO less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required DSR 2022 SI NO. 19.1 |
| 230 | Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 300mm sweep. as per direction of E/I Make :- Bajaj, Crompton or Equivalent |
| 231 | Supply and fixing of LED Tube Light with battensuitable for up 1 x 22 watt LED Tube Light fitting including tube on surface complete in all respect P.W.D.S.O.R. 2018 S.I. 1413 CAT AAA |
| 232 | CIVIL WORKCO RESIDENCEEarth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 233 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 5 km, also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc., complete. |
| 234 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size) derived from natural sources |
| 235 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttring, finishing and reinforcement as per direction of the engineer-in-charge, for thr following grades of concrete upto Plinth Level Concrete of M25 grade with minimum cement content of 330 kg/cum |
| 236 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttring, finishing and reinforcement as per direction of the engineer-in-charge, for thr following grades of concrete above Plinth level concrete of M25 grade with minimum cement content of 330 kg /cum |
| 237 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 238 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 239 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 240 | Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform |
| 241 | Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 242 | Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts |
| 243 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 244 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 245 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 246 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 247 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 248 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
| 249 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete (Size of Tile 600x600 mm) |
| 250 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. (Size of Tile 600x600 mm) |
| 251 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. |
| 252 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 253 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade.Area of slab upto 0.50 sqm |
| 254 | 12 mm cement plaster of mix for Inner Wall: 1:4 (1 cement: 4 coarse sand) |
| 255 | 12 mm cement plaster of mix for Outside Wall: 1:6 (1 cement: 6 coarse sand) |
| 256 | 15 mm cement plaster on rough side of single or half brick wall of mix :1:6(1 cement: 6 coarse sand) |
| 257 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. |
| 258 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90litre/10 sqm) |
| 259 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. |
| 260 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of requiredshade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 261 | Varnishing with varnish of approved brand and manufacture : Two or more coats glue sizing with spar varnish or an under coat of flatting varnish |
| 262 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 263 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 264 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodiccoating not less than grade AC 10 as per IS : 1868), transparent or dyed torequired colour or shade, with nuts and screws etc. complete : 300x16 mm |
| 265 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm |
| 266 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm |
| 267 | Providing and fixing glazing in aluminium door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 268 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm |
| 269 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 270 | PLUMBING WORK CO RESIDENCE Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 271 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 272 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 273 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 274 | Providing and fixing PTMT grating of approved quality and colour.Circular type100 mm nominal dia |
| 275 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore |
| 276 | Providing and fixing CP brass bib cockof approved quality |
| 277 | Providing and fixing CP brass long nose bib cockof approved quality |
| 278 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. |
| 279 | Sub Head - II -Internal PlumbingProviding and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 280 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend |
| 281 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm each |
| 282 | Providing and fixing soil, waste and vent pipes 110 mm dia UPVC SWR pipe (Aligarh SOR) |
| 283 | Providing and fixing soil, waste and vent pipes 90 mm dia UPVC SWR pipe (Aligarh SOR) |
| 284 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : For 100 mm dia pipe |
| 285 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes |
| 286 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes |
| 287 | ELECTRICAL WORK CO RESIDENCEWiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash. |
| 288 | Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed midium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 289 | Add for 2 way light point with modular switches in place of piano type switches. |
| 290 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes for FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required.2X1.5 sq. mm+1X1.5 sq. mm earth wire |
| 291 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes for FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required2X2.5 sq. mm+1X2.5 sq. mm earth wire |
| 292 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes for FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 293 | Supply and fixing of power plug with 15 Amp./250 Volt flush type universal switch and 5 pin 15 A/250 Vflush type universal socket switch on concealed G.I. box Modular type including supply of all material, labour T&P etc. required for proper completion of work. |
| 294 | Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work. |
| 295 | Sub Head - II -Distribution BoardSupplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 296 | Supplying and fixing 40 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four Pole |
| 297 | Supplying and fixing 63 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Four Pole |
| 298 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/MIW) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THO less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required |
| 299 | Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as requiredFor 4 way, Double door TPN MCBDB |
| 300 | Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as requiredFor 6 way, Double door TPN MCBDB |
| 301 | Sub Head - III - Supply And Installation of light FixtureSupply and fixingof LED Tube Lightwith batten suitablefor up to 1 X 22 watt LED tube light complete includingtube etc on surface complete in all respect. CAT-AA |
| 302 | Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter havingPowder coated die cast aluminiumhousing with heat sink, diffuser/Reflector and driver set complete in all respect CAT-AA |
| 303 | Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighterhaving Powder coated die cast aluminium housing withheat sink, diffuser/ Reflectorand driver set complete in all respect.CAT-AA |
| 304 | Supply of Ceiling Fan- 1200MM Al Blades, Aluminium Die Casted Top and Bottom with high quality copper motor RPM - 380, Air Delivery > 220 CMM |
| 305 | Supply of Exhaust Fan : 450 mm sweep Metal Body Copper motor |
| 306 | Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts, nuts and washers etc., complete in all respect. |
| 307 | Erection and testing of ceiling fan and regulator etc. excluding supply of down rod, complete in all respect. |
| 308 | Sub Head -V - Data and TV pointsSupplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 309 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 310 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as requiredTV antenna socket outlet |
| 311 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as requiredTelephone socket outlet |
| 312 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 313 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) |
| 314 | Supply and fixing and concealing of 20 mm dia. 2mm thick PVC conduit pipe with ISI mark embossed and with PVC accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and T&P etc required for proper completion of the work as per directions and to the satisfaction of Engineer in charge |
| 315 | Same as in item 148 (A) but 25 mm dia 2 mm thick PVC conduit. |
| 316 | SUBHEAD IV-EARTHING SYSTEMSupply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm diaG.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. |
| 317 | Supplying & Laying of 25mmx5mm G.I. Strip on surface for earthing purpose as required complete in all respects. |
| 318 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 319 | C.C ROAD Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loan clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c withinalead of 50m. |
| 320 | Providing and layingin cement concrete 1:4:8 (1 cement: 4 fine sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors . |
| 321 | Class 150 brick work in1:6cement and corse sandof2.25fineness modulus mortar in foundation and plinth including supply ofall materials,labour andtools and plants etc.requiredforpropercompletion of the work. |
| 322 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources) 4.1.3 |
| 323 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade \"A\" sealing compound. |
| 324 | INTERLOCKINGEarth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out |
| 325 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 326 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 327 | Providing and laying 60mm thick faciory made cement concret interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 328 | BOUNDARY WALLDemolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix |
| 329 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 330 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1cement: 4 coarse sand) |
| 331 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 332 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 333 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) |
| 334 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 335 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately |
| 336 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 337 | EXTERNAL ELECTRIC WORKElectrical PanelSupply, assembly, erection, connecting, testing & commissioning of LT weather proof dust and vermin proof, outdoor feeder pillar, fabricated out of suitable sized angle iron and flats and covered with 3mm thick CRCA sheet steel including canopy, duly stove enamel painted, both sides (front and rear) openable with locking arrangement, rubber gasket cable glands, etc. Bakelite phase separators and bus bar supports including RCC 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size)foundation, 450 mm deep and 150 mm above the ground. The feeder pillars shall be complete with 3 phase and neutral bus bars of capacities as described below and moulded case circuit breakers (MCCBs) with adjustable overload relay, copper FRLS control wiring with 1.5sq.mm, complete in all respects as per specifications as required.100A FP ATS - 1no.INCOMING:-100A FP MCCB (25ka) with thermal magnetic release & rotary handle - 1no.3 Phase and neutral (100%N) aluminium bus bars of 150/ 100 amps. Capacity. OUTGOING:-70 AMP. TP CONTACTOR WITH NO/ NC CONTACTS -1 set.24 HOUR TIMER - 1 set.25A DP MCB (10ka) - 4 nos.16A DP MCB (10ka) - 4 nos.40A DP MCB (10ka) - 4 no.63A TPN MCB (10ka) - 9 no.16 AMP. SWITCH & SOCKET - 1 no. with in the feeder pillar.ExternalFeeder Pillar as above |
| 338 | Supply and fixingof LED Street light Fitting having die cast aluminiumbody and diffuserwith driver set suitable for 45 watt to 50 Watt. Confirmingto IP 65 and above protectioncomplete in all respect. CAT- AAA |
| 339 | Supply & fixing of 8mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 135 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. |
| 340 | Sub Head- III- LT Cables Supply, laying,testing and commissioning of 1.1 kv gradeXLPEinsulated PVC sheathed steel armoured alluminium stranded conductorISI marked LT Cables in trenches/ ducts/ through RCC pipes under roads/ on cable trays of following sizes, complete all as specified (as per CPWD specifications for External Electrical works), i/c clamping, dressing, earth work digging, sand filling, bricks protection, back filling etc. as required & approved by Engineer\"s Incharge. (Tagging to be provided with aluminium strips on both the ends as approved).3½core X 95 Sq.mm. |
| 341 | Supply, laying,testing and commissioning of 1.1 kv gradeXLPEinsulated PVC sheathed steel armoured alluminium stranded conductorISI marked LT Cables in trenches/ ducts/ through RCC pipes under roads/ on cable trays of following sizes, complete all as specified (as per CPWD specifications for External Electrical works), i/c clamping, dressing, earth work digging, sand filling, bricks protection, back filling etc. as required & approved by Engineer\"s Incharge. (Tagging to be provided with aluminium strips on both the ends as approved).3½core X 35 Sq.mm. |
| 342 | Supply, laying,testing and commissioning of 1.1 kv gradeXLPEinsulated PVC sheathed steel armoured alluminium stranded conductorISI marked LT Cables in trenches/ ducts/ through RCC pipes under roads/ on cable trays of following sizes, complete all as specified (as per CPWD specifications for External Electrical works), i/c clamping, dressing, earth work digging, sand filling, bricks protection, back filling etc. as required & approved by Engineer\"s Incharge. (Tagging to be provided with aluminium strips on both the ends as approved).4 core X 25 Sq.mm |
| 343 | Supply, laying,testing and commissioning of 1.1 kv gradeXLPEinsulated PVC sheathed steel armoured alluminium stranded conductorISI marked LT Cables in trenches/ ducts/ through RCC pipes under roads/ on cable trays of following sizes, complete all as specified (as per CPWD specifications for External Electrical works), i/c clamping, dressing, earth work digging, sand filling, bricks protection, back filling etc. as required & approved by Engineer\"s Incharge. (Tagging to be provided with aluminium strips on both the ends as approved).4 core X 16 Sq.mm |
| 344 | Supply, laying,testing and commissioning of 1.1 kv gradeXLPEinsulated PVC sheathed steel armoured alluminium stranded conductorISI marked LT Cables in trenches/ ducts/ through RCC pipes under roads/ on cable trays of following sizes, complete all as specified (as per CPWD specifications for External Electrical works), i/c clamping, dressing, earth work digging, sand filling, bricks protection, back filling etc. as required & approved by Engineer\"s Incharge. (Tagging to be provided with aluminium strips on both the ends as approved).4 core X 10 Sq.mm |
| 345 | Supplying and making cable end termination with brass compression glands and aluminium lugs including inhibiting compound to be used in each lug, for the following XLPE aluminium conductor armoured cables of 1.1 KV grade etc, complete as required.3½core X 95 Sq.mm. |
| 346 | Supplying and making cable end termination with brass compression glands and aluminium lugs including inhibiting compound to be used in each lug, for the following XLPE aluminium conductor armoured cables of 1.1 KV grade etc, complete as required.3½core X 35 Sq.mm. |
| 347 | Supplying and making cable end termination with brass compression glands and aluminium lugs including inhibiting compound to be used in each lug, for the following XLPE aluminium conductor armoured cables of 1.1 KV grade etc, complete as required.4 core X 25 Sq.mm |
| 348 | Supplying and making cable end termination with brass compression glands and aluminium lugs including inhibiting compound to be used in each lug, for the following XLPE aluminium conductor armoured cables of 1.1 KV grade etc, complete as required.4 core X 16 Sq.mm |
| 349 | Supplying and making cable end termination with brass compression glands and aluminium lugs including inhibiting compound to be used in each lug, for the following XLPE aluminium conductor armoured cables of 1.1 KV grade etc, complete as required.4 core X 10 Sq.mm |
| 350 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 351 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 352 | Earthing with G.I earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr longetc.with charoal or coke and salt as required. |
| 353 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 354 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 355 | SEPTIC TANKEarthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out construction of shoring & bracing ,removal of stumps and other deleterious materials and disposal upto a lead of 50m,dressing of sides and bottom and backfilling in trenches with excavated suitable material.From 0.00 mt to 1.50 mt |
| 356 | Earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out construction of shoring & bracing ,removal of stumps and other deleterious materials and disposal upto a lead of 50m,dressing of sides and bottom and backfilling in trenches with excavated suitable material.1.50mt to 3.0 mt |
| 357 | Earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out construction of shoring & bracing ,removal of stumps and other deleterious materials and disposal upto a lead of 50m,dressing of sides and bottom and backfilling in trenches with excavated suitable material.3.0 mt to 4.50 mt |
| 358 | Providing & laying cement concrete in 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggreagate 40mm nominal size) including supply of all materials,labour and T & P etc. required for completion of work and curing complete including cost of form work in foundation and floors |
| 359 | R.c.c. workwith cement approved coarse sandand2cm. (3/4\") guageapproved stoneballastin the proportion of 1:1.5:3(M-20) in slabexcludingsupply of reinforcement and its fixing and binding the same with 24 B WG bindingwireand including necessary centeringand shuttering etc.and also including supply of all materials,labour andtools and plants etc, required forproper completion of the works. strength of the concrete shall not beless than M-20 |
| 360 | 1st Class brickwork in 1:4 cement & coarse sand of 1.50 fineness modulus mortar in foundation & plinth including supply of all material labour and tools and plants etc required for proper completion of work. |
| 361 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work(whennot includedin anover all rates )wroughttorequired shape as necessary including bending for proper completion of thework andincluding supply of steel itswastage and over lapping and hookes required for completion of the work TMT Fe 500 |
| 362 | 25mm thick 1:2:4 cement concrete floor with cement approved coarse sand & 2cm graded dala stone grit laid in planels finished with 3mm floating coat of neat cement bor cement and marble dust in ratio of 5:1 as specificover and excluding base concrete and removing any overlapping mortar at the joints of the panels if any giving them a uniform finish, including supply of all materisls labour, T&P etc. required for proper completion of work |
| 363 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & Coarse sand) |
| 364 | Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 1729 |
| 365 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar) |
| 366 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 367 | STORMWATER DRAINEarth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out |
| 368 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 369 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 370 | 20 mm thik Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. |
| 371 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (40 mm flooring) |
| 372 | TUBEWELLBoring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart! bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 350 mm dia upto 60 mtr. |
| 373 | 300 mm dia 60-90 mtr. |
| 374 | 90-150 mtr. |
| 375 | 150-220 mtr. |
| 376 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia having minimum wall thickness 5.00 mm |
| 377 | 200 mm nominal size dia having minimum wall thickness 5.40 mm |
| 378 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mru, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fitting & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia |
| 379 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assemblv of tube well as oer IS:2800150 mm dia |
| 380 | Providing and fixing M.S. clamp of required dia to the top of casing! housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp |
| 381 | Supplying, filling, spreading & leveling\" gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of\" Engineer-in-charge |
| 382 | Development of tube well in accordance with IS : 2800 (part 1) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \"V\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, ilc disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer- in-charge |
| 383 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing! casing pipe, rmovable as per requirement, all complete for borewell200 mm dia |
| 384 | Supply of 7.5 HP 3 phase submersible pump |
| 385 | Supply of control panel 3 phase with single phasing preventer |
| 386 | Supply of submersible cable 2.5 sqmm |
| 387 | Supply of 80mm dia MS column pipe having length of 3 mtr each |
| 388 | RAIN WATER HARVESTINGEarth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.In all kind of soil upto 1.5m depth |
| 389 | Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.In all kind of soil upto 1.5m to 3.0m. depth |
| 390 | Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.In all kind of soil upto 3.0m to 4.5m. depth |
| 391 | Providing and laying in position cement concrete of specified grade-All work up to plinth level:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 392 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 393 | R.C.C work with cement approved coarse sand and 2 cm gauge approved stone grit in proportions of 1:1.5:3 (In Raft/foundation) |
| 394 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Mild steel and Medium Tnsile steel bars. |
| 395 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:6 (1 cement: 6 coarse sand) |
| 396 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar |
| 397 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter |
| 398 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually. |
| 399 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia |
| 400 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 401 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 402 | Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 403 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 404 | S/F of upvc SWR Pipe Type -B confirming to IS -13592 incluiding jointing the pipes with rubber ring lubricant and UPVC SWR Cuplar confirming to IS 14735 also inluiding excavation of treches cutting of walls and holes and repairing of walls , floors and refilling the trenches as before cut including cost of other fittings such as door band, T and YT including supply of all materials labour and t&p required for prper complition of the work.160 mm. dia. |
| 405 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement andmaking channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design a) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 406 | EXTERNAL PLUMBING WORKExcavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m.All kinds of soilPipes, cables etc. exceeding 80mm dia but not exceeding 300mm. |
| 407 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 250 mm dia. R.C.C. pipe |
| 408 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 300 mm dia. R.C.C. pipe |
| 409 | Providing and laying cement concrete 1:5:10(1cement:5coarse sand :10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design250 mm. dia. |
| 410 | Providing and laying cement concrete 1:5:10(1cement:5coarse sand :10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design300 mm. dia. |
| 411 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge32 mm nominal dia Pipes |
| 412 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge40 mm nominal dia Pipes |
| 413 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge50 mm nominal dia Pipes |
| 414 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge65 mm nominal dia Pipes |
| 415 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge80 mm nominal dia Pipes |
| 416 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : |
| 417 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design150 x 100 mm size P typeWith Brick M-150 |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail