| 1 | Testing, checking &fault finding of Automatic Fire Detection, Fire Alarmsystem comprising ofFire control panels , Fire Detectors , Manualcall points, Electronic Hooters etc.assessing the faults and material required for repairing and rectification of faults i/c rectification of minor faults, testing for proper functioning etc. complete as required. |
| 2 | Ground Floor with Main Fire Alarm Control panel (FACP) |
| 3 | 1st/2nd Floor with Local Control panels |
| 4 | Supply, installation testing and commissioning of following ZonesUL listed Microprocessor based Fire Alarm Control Panel Made of16/18 SWG CRCA sheet powder coated, finish suitable for operation with 220V 50HZ AC mains power supply with standby battery backup 24Volt DC power supply and built in charger (without batteries) , normal operating voltage 24 v DC, compatible with all types of conventional detectors, manual call points and normally opened dry contact devices, 16X2 Dot matrix display, fully compatible with UL-864 and NFPA-72 etc. complete as required as per details specifications. (make- Agni Instruments / Agni Devices/GST / Honeywell / system sensor / Ravel) |
| 5 | 4 Zone Main/Local Control panel without PA system |
| 6 | 6 Zone Main/Local Control panel without PA system |
| 7 | SITC of12Vsealed maintenance free battery of not less than 7AH capacity with all accessoriesetc as reqd.(Exide /Amco/S S Make) |
| 8 | Supply, installation, testing and commissioning of UL listed, CE certified 2 wire conventional Photo electric / Ionization type Smoke detector with base (Blinking LED type) made of ABS plastic with all accessories, suitable for operation on 24v DC, internal protection class: IP23, dual pulsing LED with 3600 visibility, relative humidity:≤95%; non-condensing and EN54 compliance of approved make etc. as required. (Make- Apollo / GST/ Honeywell / System sensor) |
| 9 | Supply, installation, testing and commissioning of UL listed, CE certified 2 wire conventional Multidetector(fixed cum rate of rise heat Detector using a thermistor, raises an alarm when the detector reaches 590C (Fixed) or when the change in temperature exceeds the rate of rise of 110C/min) withbase (Blinking LED type)made of ABS plasticand all accessories, suitable for operation on 24 v DC, internal protection class: IP23, dual pulsing LED with 3600 visibility, relative humidity:≤95%;non-condensing and EN54 compliance of approved make etc. as required.(Make- Apollo / GST / Honeywell / System sensor) |
| 10 | Supply, installation, testing and commissioning of electronic hooter cum speaker made of 16/18SWG CRCA sheet duly powder coated with PO red colour, output not less than 80db @25mtr, LMT with adjustable sound output of 2.5-watt,5-watt, suitable knock out for cable entry from top suitable for operation on 100/70-volt RMS AC supply etc. as required. (Make- Apollo / Honeywell / GST/ system sensor/ Ravel /Agni) |
| 11 | SITC of manual push button station (pill box) Manual Call Point in MS Housing for Conventional Fire Alarm System with glass for breaking up in case of fire and hammer with chain etc. (Make- Apollo / Honeywell / GST/ system sensor/ Ravel /Agni) |
| 12 | SITC of twin LED type response Indicators with suitable 16-gauge M.S./Alumunium box, acrylic sheet cover of min 2mm thick LED etc. as required. (Make- Apollo / Honeywell / GST/ system sensor/ Ravel /Agni) |
| 13 | Supply and laying of2 CORE X 1.5 SQ MMFRLS PVC insulated and PVC sheathed copper conductor unarmoured heavy dutyflexible cable on surface/recess for fire alarm devicesetc. as required. (ISI) |
| 14 | Supply and laying of2 CORE X 1.5 SQ MMFRLS PVC insulated and PVC sheathed copper conductor armoured heavy dutyflexible cable on surface/recess for fire alarm devices etc. as required. (ISI) |
| 15 | Supplying and making indoor end termination with brass compression gland and copper lugs for 2 core, 1.5 Sq. mm size of PVC insulated and sheathed/XLPE copper conductor cable of 1.1 KV grade as required. |
| 16 | S/F ABS round box / MS Boxon ceiling for fixing the detectors etc. as reqd. |
| 17 | Supplying & fixing of wall mounted auto glow Signage Fire Exit Sign Board 3mm PVC Sheet with high Glow intensity in total Darkness. (Red and Green colour with exit symbols as per requirements) |
| 18 | Refilling of 4.5 KG CO2 type Portable Fire Extinguisher with fresh /sufficient quantity / quality of CO2 with proper weight and measure, labeling with date of refilling and expiry date of refilling as per the ISI standards and as per the norms of Fire Authorities. Re-fixing the same in proper position and location as per the requirement of the location and type of fire extinguisher . |
| 19 | Hydraulic Pressure Testing of 4.5 capacity CO2 type Fire Extinguishers as per IS: 5844 -1970 (Reaffirmed 2006) and submission of Test certificates etc. as required. |
| 20 | Providing and fixing of Gas Discharge Hose & Horn for4.5 KG CO2 type Portable Fire Extinguisher |
| 21 | Providing and fixing Gun metal regulating valve with safety washers for 4.5 Kgcapacity Carbon Dioxide type Fire Extinguishers as per BIS specifications. {(IS: 3224:2002 (Reaffirmed 2007)} (The dismantled scrap material may be retained by the agency) |
| 22 | Providing and fixingMS clamp for fixing CO2 4.5 Kg capacityfire extinguishers on wall etc. as required. |