| 1 | (A)Renovation/up-gradation of 132 Kv (DC) Wanpoh-Awantipora LILO Bay |
| 2 | Surveying of the line for identification of site of new D+3 Kamani tower including tower spotting, pit marking and checking of alingmentcritical pointand framing of approved tower profile and schedule including site clearance & crop compensation if required |
| 3 | Earth Workexcavation of foundation pits including all Labour, T&P, leads & lifts, stockpiling, making of working space, carriage, disposal of excaveted soil, backfilling includingcost of borrowed good earth & dressing of surplus excavated earth and dewatering during excavation including sitecleareance |
| 4 | Close timbering in trenches including strutting and shoring complete. Only forPartially Submerged and Fully Submerged Foundations |
| 5 | Depth exceeding 1.5m but not exceeding 3m |
| 6 | Reinforcement for R.C.C. work including straightning, cutting,bending, placing in position and binding all complete bars (TMT) including all carriages(manual and mechanical) |
| 7 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Supply Of Stubs and cleats(as per drawing) |
| 9 | Stub setting including transportation, carriage of Stubs & Templates. |
| 10 | Providing and laying in position cement concrete of specified grade including curing ,Carriage of materials Mechanical & Mannual but excluding th cost of centring and shuttering.All workupto plinth level with: |
| 11 | 1:3:6 (1cement:3coarse sand:6 graded stone aggregate 40mm nominal size) with stone solling 20 cm in depth |
| 12 | Providing and laying in position specified grade of reinforced cement concrete including curing Carriage of materials Mechanical & Mannual but excluding the cost of centering, shuttering, finishing and reinforcement. Allworks up to plinth level (M25) including all carriages and dewatering |
| 13 | Centering and shuttering including strutting, propping etc.and removal of form work for: |
| 14 | Foundations,footings,bases for columns |
| 15 | Providing and fixing of pipe earthing including earth resistivity including counterpoise whereever required. |
| 16 | MATERIAL PART |
| 17 | Fabrication, Galvanisation and Supply of Lattice Type Steel Tower Structures |
| 18 | Galvanised Nuts & Bolts with Washers |
| 19 | Tower Accessories |
| 20 | Danger Plates |
| 21 | Number Plates |
| 22 | Circuit Plates |
| 23 | Phase Plate |
| 24 | Anti Climbing Devices |
| 25 | Bird Guard |
| 26 | Line Material & Accessories |
| 27 | ACSR 400 sqmm |
| 28 | Conductor Accosseries for400 sqmmASCR |
| 29 | Mid Span Compression Joint |
| 30 | Vibration Dampers |
| 31 | Repair Sleeves |
| 32 | Aluminium Tap |
| 33 | Earthwire Accessories |
| 34 | Mid Span Compression Joint |
| 35 | Vibration Dampers |
| 36 | Hardware Fittings Suitable For 400 sqmmASCR |
| 37 | Single Suspension Fittings |
| 38 | Single Tension Fittings |
| 39 | Aluminium alloy T Clamps 400 sqmm |
| 40 | OPGW |
| 41 | Clamps for OPGW |
| 42 | Insulators |
| 43 | 120 KN ball & socket type Porcelain Disc Insulators |
| 44 | Other equipments |
| 45 | 145kV, 50c/s , 2000 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades |
| 46 | 4 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete |
| 47 | 8 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete |
| 48 | Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, selfsupporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly stoved. The paint thickness shall be at least 50 microns. |
| 49 | Dismantling/ re-erection |
| 50 | Dismantling of existing 132 Kv Awantipora LILO Bay equipment structures, CT\"s \"PT\"s & LA\"s etc. |
| 51 | Re-erection of dismantled 132 Kv Awantipora LILO bay structure, CT\"s, PT\"s& LA;s etc. |
| 52 | Dismantling of existing D Type tower, 02 No. 132 Kv Isolators, panther conductor including insulators, fittings, jumpers & other allied accessories & returing of same to the divisional stores at awantipora |
| 53 | Erection Part |
| 54 | Erection of 01 No. D+3, Kamani tower complete with Nuts & Boltsincluding,transportation to site, tag welding and application of Zinc Rich Paint,Pipe earthing &crop compensation (complete) |
| 55 | Erection of Tower Accessories |
| 56 | Danger Plates |
| 57 | Number Plates |
| 58 | Circuit Plates |
| 59 | Phase Plate |
| 60 | Anti Climbing Devices |
| 61 | Bird Guards |
| 62 | Laying & Stringing of 400 sqmm ACSRconductor /Earth wire including installation of insulator strings, hardware fittings, arching horns, vibration dampers, jumpring, compression joints (if required) and other accessories including transportation to site and temporary anchoring of towers.(Including 1.5% sag) |
| 63 | Laying & Stringing of OPGW Wireincluding installation of hardware clamps,vibration dampers,jumpring, compression joints (if required)and other accessories including transportation to site and temporary anchoring of towers..(Including 1.5% sag) |
| 64 | Testing & Commissioning of Transmission Line |
| 65 | Execution of Other equipments |
| 66 | 145kV, 50c/s , 2000 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades |
| 67 | 4 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete |
| 68 | 8 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete |
| 69 | Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, selfsupporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly stoved. The paint thickness shall be at least 50 microns. |
| 70 | Cable Ducts With Covers as per the design of existing |
| 71 | Sub Main Duct of Size 600mm x 600mm with6 mm M.S Chequered Trench Covers of size 700x500 mm |
| 72 | Civil Works |
| 73 | Concreting and laying of Yard metal |
| 74 | Surface dressing of ground removal of inequalities less than 15cms ( de- vegetation) |
| 75 | Supply & laying stone soling 100mm thick including mechanicalfrom nearest source & mannual carriage |
| 76 | Providing & laying Cement Concreate 1:3:6, 100mm Thick including mechanicalfrom nearest source & mannual carriage |
| 77 | Supply, spreading & levelling of metal Crushed (Aggregate 40 mm size) (1150X0.10) including mechanicalfrom nearest source & mannual carriage |
| 78 | Design & laying of Earth Mat as per approved design |
| 79 | Earth work excavation |
| 80 | Manual carriage of disposable earth beyond 100mts (60% of Excavated earth) |
| 81 | Mechanical carrige of Disposable earth at an average lead of 5 Km |
| 82 | Supply of good and soft earth including filling, levelling & Royality etc |
| 83 | Mechanical carrige of good earth at an average lead of 20 Km |
| 84 | Manualcarriage of good earth from unloading site to site of work |
| 85 | Loading and unloading of earthing material |
| 86 | Laying of 100mts of MS Flat/ Round steel |
| 87 | Surface cleaning ,jointing by welding etc |
| 88 | Driving of Spikes |
| 89 | Providing of Steel, galvanised Flat iron 75mmx12mm/50mmx6mm) and 40mm dia round steel bars |
| 90 | Laying of 02 No. 132KV isolator Foundations, 06 No. PT foundations, 06 No. CT foundations & 06 No. LA foundations. |
| 91 | Earth workin excavation by mechanical means (Hydraulic excavator) over areas( exceedind 30 cm in depth 1.5 mtr in width as well as 10 sq.m on plan ) including disposalof excavated earth, lead upto 50 m. & , lift upto 1.50 m disposad earth to be levelled and neatly dressed in All kinds of soil |
| 92 | Providing and laying of lean pad 1:4:8 with 40mm crushed stone aggregate 4.0x4.0x0.10 |
| 93 | Form work |
| 94 | Providing and laying of RCC conc. 1:1.5:3 (M20) with 20mm bajri |
| 95 | Mech.transport of construction material average lead 20 km |
| 96 | 20mm bajri |
| 97 | 40mm bajri |
| 98 | Sand |
| 99 | Manual carriage of construction of material from unloading site to site of work lead 100 mtr |
| 100 | 20mm bajri |
| 101 | 40mm bajri |
| 102 | Sand |
| 103 | Back filling |
| 104 | Excavation of good earth in soft soil |
| 105 | Mech carriage of good earth av lead 20km |
| 106 | Manualcarriageofgoodearthfromunloadingsiteto site of work av distance 100 mtr |
| 107 | Manual carriage of disposable soil upto loading site avdistance 100 mtr |
| 108 | Mech transportation of disposable soilav lead 3 km |
| 109 | Providing of tor steel reinforcement including cutting , bending & binding |
| 110 | Manual carriage of cement Av. 100 mtr |
| 111 | Manual carriage of steel |
| 112 | Providing & fixing of stubs as per approved drawing |
| 113 | (B)Replacemnet of old detorated33 Kv equipments and conductor |
| 114 | Design, Engineering, Manfacture,Shop Testing, Supply including packing and forwarding, Transportation and delivery at site as per Technical Specifications and approved drawings |
| 115 | 33KV VCB (36 KV, 1250 Amps of 3 phase, 50 c/s and 25KA for 3 sec) outdoor type with all accessories and auxiliaries |
| 116 | 36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades |
| 117 | 36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Blades |
| 118 | Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications) , 25KA for one second, rated dynamic current 25KA(peak), Class A insulation,Burden 20 VA |
| 119 | 8 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete |
| 120 | 16 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete |
| 121 | 4 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete |
| 122 | 500 mm2 ACSR Conductor moose |
| 123 | Single tension fittings for twin 500 mm2 moose |
| 124 | Single suspention fittings for twin 500 mm2 moose |
| 125 | T clamps 500mm2/500mm2 |
| 126 | Isolator pad clamps 500mm2/500mm2 |
| 127 | Tubular bus clamp (100 mm Dia) 500mm2 |
| 128 | Spacers For Twin 500mm2 must be one-piece construction of aluminum alloy of an approved type without any projection, cuts, abrasions etc. or chattering parts and shall conform to IS:10162 |
| 129 | P I Clamps made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition) |
| 130 | Handling, Storage, Preservation, Erection, Testing and commissioning of equipments and material including all comsumables required for 50 MVA Power Transformer, 33 KV VCB\"s, 32 & 33 KV surge arrestors includingFerrules, Lugs, Printed sleeves, cable ties, cable glands, Tags, minor cutting, wielding works etc. complete in all respects |
| 131 | 33KV VCB (36 KV, 1250 Amps of 3 phase, 50 c/s and 25KA for 3 sec) outdoor type with all accessories and auxiliaries |
| 132 | 36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades |
| 133 | 36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Blades |
| 134 | Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications) , 25KA for one second, rated dynamic current 25KA(peak), Class A insulation,Burden 20 VA |
| 135 | 8 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete |
| 136 | 16 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete |
| 137 | 4 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete |
| 138 | 500 mm2 ACSR Conductor moose |
| 139 | Single tension fittings for twin 500 mm2 moose |
| 140 | Single suspention fittings for twin 500 mm2 moose |
| 141 | T clamps 500mm2/500mm2 |
| 142 | Isolator pad clamps 500mm2/500mm2 |
| 143 | Tubular bus clamp (100 mm Dia) 500mm2 |
| 144 | Spacers For Twin 500mm2 must be one-piece construction of aluminum alloy of an approved type without any projection, cuts, abrasions etc. or chattering parts and shall conform to IS:10162 |
| 145 | P I Clamps made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition) |