| 1 | CIVIL WORK (Industrial Shed) |
| 2 | 1). Excavation of column pit |
| 3 | 2). Boulder Filling |
| 4 | a). In Column pit |
| 5 | b). In Plinth Shed |
| 6 | 3). Mass Concrete |
| 7 | a). In Column pit |
| 8 | b). In Plinth Shed |
| 9 | 4). M 20 Great Concrete |
| 10 | a). For R.C.C. Footing |
| 11 | 5). M 20 Great Concrete for column |
| 12 | a). C1 |
| 13 | 6). M 20 Great Concrete for column |
| 14 | a). For Plinth Beam |
| 15 | b). For Coaping |
| 16 | c). For Floor Beam |
| 17 | 7). Back Filling With sand & Murrum In Column pit |
| 18 | a). In Plinth Shed |
| 19 | 8). Burnt Brick Masonry for Plinth |
| 20 | a). L - 33.24 , W - 0.23 |
| 21 | b). L- 13.14 , W - 0.23 |
| 22 | 9). Burnt Brick Masonry 0.23m Thick for Superstructure |
| 23 | a). L - 33.24 , W - 0.23 |
| 24 | b). L- 13.14 , W - 0.23 |
| 25 | Deduction |
| 26 | R/S |
| 27 | W1 |
| 28 | 10). Steel |
| 29 | 11). Cement Plaster |
| 30 | a). nner Plaster -Godown |
| 31 | b). Outer Plaster |
| 32 | Deduction |
| 33 | R/S |
| 34 | W1 |
| 35 | 12). White Wash |
| 36 | 13). Teak Wood |
| 37 | 14). SteelWindows & Ventilators |
| 38 | 15). Structural Steel For Trusses |
| 39 | 16). Corrugated Galvanized Iron Sheets |
| 40 | a). Top Shed |
| 41 | 17). Borewell |
| 42 | FIRE FIGHTING SYSTEM |
| 43 | A). Fire Pump Room Equipment as per IS 15301 |
| 44 | 1). Electric Motor driven common stand by pump & main pump |
| 45 | 2). Electrical Jockey pump |
| 46 | 3). Motor Control Panel. |
| 47 | 4).FRLS, PVC |
| 48 | 5). M.S.CLASS- C pipes |
| 49 | a). 100 mm nominal dia. |
| 50 | b). 80 mm nominal dia. |
| 51 | c). 50 mm nominal dia. |
| 52 | d). 25 mm nominal dia. |
| 53 | 6). Butterfly Valve |
| 54 | a). 100 mm nominal dia. |
| 55 | b). 80 mm nominal dia. |
| 56 | 7). Type Strainer |
| 57 | a). 80 mm nominal dia. |
| 58 | 8). Pressure Switches |
| 59 | 9). Pressure gauges |
| 60 | 10). Air release valve |
| 61 | 11). Non Return Valves C.S. |
| 62 | a). 80 mm nominal dia. |
| 63 | 12). Ball valves |
| 64 | a). 50 mm nominal dia. |
| 65 | b). 25 mm nominal dia. |
| 66 | 13). Rubber Expansion Bellows for pump connections |
| 67 | a). 80 mm nominal dia. |
| 68 | 14). Air Vessel |
| 69 | 15). Supply & laying, fixing of CableTray & Accessories |
| 70 | 16). Steel Structure Support |
| 71 | B). EXTERNAL HYDRANT SYSTEM AS PER IS 13039 |
| 72 | 1). M.S. pipes |
| 73 | a). 80 mm nominal dia. |
| 74 | b). 25 mm nominal dia. |
| 75 | 2). Butterfly ValveISI marked, rating PN-16. |
| 76 | a). 80 mm nominal dia. |
| 77 | 3). Swinging type Wall Mounting TypeMS Hose reel |
| 78 | 4). C.I. Body 2 Way Fire Brigade connection |
| 79 | 5). M.S. Structural Steel |
| 80 | 6). Pedestial support (M.S. PLATE) |
| 81 | 7). ALLTHE CIVIL & EXCAVATI ON WORK |
| 82 | 8). Ball valves |
| 83 | C). FIRE ALARM SYSTEM IS 2189 |
| 84 | 1). SITC of Conventional Zone wise Fire Alarm Control panel. |
| 85 | 2). OPTICAL type Smoke Detector |
| 86 | 3). Sensor Base type Heat Detector |
| 87 | 4). Manual call point. With Base box |
| 88 | 5). Hooters Cum Flasher |
| 89 | 6). Auto mode FIRE EXIT board |
| 90 | 7). B91FRLS2core x 1.5 Sq. mm copper armoured Cable. |
| 91 | D). FIRE EXTINGUISHERS AS PER IS 2190 |
| 92 | 1). ISI marked Fire Extinguisher, ABC type Dry chemical powder Fire Extinguisher |
| 93 | 2). Supplying and Fixingof Signages. |