| 1 | Dismantling wall and ceiling boards (fibre, pulf, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 2 | S&F hangers 6mm dia GI (upto 1200mm length) adjusting level, fixed to roof slabs by means of ceiling cleats made out of GI flat of size 40mm x 3mm with 60mm long and expansion hold fasteners 12.5mm dia, 40mm long for grid of size 605 x 605mm complete all as specified and as directed. |
| 3 | S&F for false ceiling with anodized aluminium snap grid of size 605x605mm to support the boards/tiles including proper hanging arrangement with anodized galvanised iron wire and adjuster complete all as specified and as directed. |
| 4 | S&F 6mm thick high pressure steam cured non asbestos fibre cement designer ceiling board of size to suit grid mould (605x605mm as specified above) and fixed in grid mould with necessary fixing arrangement as per manufacturer\"s instruction including taking down old existing unserviceable one complete all specified and as directed. |
| 5 | M&L for 4mm thick plywood grade BWR, type BB, fixed with screws to timber frame work complete all as per specified and as directed. |
| 6 | Dismantling fillets, rails, posts, rafters, purlins, etc. under 40 Sq.cm in section for unframed work complete all as specified and as directed. |
| 7 | Dismantling timber scantling, 40 Sq.cm and over in section, in any position, in unframed work complete all as specified and as directed. |
| 8 | M&L for 2nd class hard woodtimber scantlings, clean sawn complete all as specified and as directed. |
| 9 | M&L for 2nd class hard wood plain, fillets, square rectangular or triangular in section, clean sawn, cross sectional area exc 6.0 Sq.cm and not exc. 13 Sq.cm, screwed with nails complete all as specified and as directed. |
| 10 | M&L for 2nd class hard wood plain, fillets, square rectangularor triangular in section, clean sawn, sectional area exc. 13.0 Sq.cm and not exc. 25 Sq.cm, screwed with nails complete all as specified and as directed. |
| 11 | M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth and treated with two coats of creosate oil complete all as specified and as directed. |
| 12 | M&L for preparation of new wooden surface of any description not otherwise described for, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed. |
| 13 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including \"Nainital\" or similar pattern roof covering complete all as specified and as directed. |
| 14 | S&F pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/ cladding to wall, etc. fixed with self tapping screw complete all as specified and as directed. |
| 15 | S&F pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, etc.,fixed with self tapping screw complete all as specified and as directed. |
| 16 | S&F 0.63mm galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls, etc. with grade of zinc coating 275 complete all as specified and as directed. |
| 17 | S&F 0.63mm plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed. |
| 18 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 19 | S&F hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 20 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracketframing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming toFe-410-W, Gde E-250 complete all as specified and as directed. |
| 21 | S&F joist, channel, angle or tee sections, fixed independently without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of length indicated) conforming to Fe-410-W, Gde E-250, quality \"A\" complete all as specified and as directed. |
| 22 | M&L for preparation of new steel surface of any description, not otherwise described for, not exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 23 | M&L for preparation of new steel surface of any description, not otherwise described for over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 24 | M&L for cutting holes in brick walls in cement mortar for inserting holdfasts, etc. and making good to dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as required depth of embedded portion of hold fasts, etc. exc. half brick and not exc. one brick complete all as specified and as directed. |
| 25 | Demolition of cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended work complete all as specified and as directed. |
| 26 | Taking down cement or cement lime plaster onbrick or stone walls, ceilings, etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed. |
| 27 | M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry in the ratio (1:3) complete all as specified and as directed. |
| 28 | M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar (1:3) complete all as specified and as directed. |
| 29 | M&L for PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in roof surfaces with WPC @ 500gm/50 Kg cement complete all as specified and as directed.NOTE: WPC shall be measured and paid separately. |
| 30 | M&L for PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamferred on edges complete all as specified and as directed. |
| 31 | M&L for 20mm thick rendering in cement mortar (1:3) on fair faces of brick work, mixed with water proofing liquid compound on walls and roof surfaces, finished even and smooth without using extra cement complete all as specified and as directed.NOTE : WPC shall be mixed @ 500gm/50 Kg cement or as recommended by manufacturer and the same shall be measured and paid seperately. |
| 32 | Supply only integral water proofing compound (WPC) complete all as specified and as directed. |
| 33 | M&L for applying evenly a coat of bitumen primer @ 0.40 litre per Sqm by the same membrane manufacturer of density 25°C, 0.87 to 0.89 litre and viscosity 70-160 cps after proper cleaning the surfaces of rendering complete all as specified and as directed. |
| 34 | All as per Serial item No. 33 here-in-before but for vertical surfaces. |
| 35 | M&L for APP based polymeric membrane, minimum weighing 3.6 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (Wt not less than 150 gms/sqm), laid on primed surface with side over lap of 75mm and end overlap of 100mm using bitumen torch or by LP gas torching and sealing all joints, etc. and ensuring complete thermo fusing and applying one coat of aluminum paint over it complete all as specified and as directed. |
| 36 | All as per Serial item No. 35 here-in-before but for vertical surfaces. |
| 37 | Demolition of brick work, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. complete all as specified and as directed. |
| 38 | M&L for brickwork with sub class ‘B’ bricks,straight or curved on plan, exc. 6m mean radius, built in cement motar (1:6) complete all as specified and as directed. |
| 39 | Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or re-fixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed. |
| 40 | S&F PVC (SWR) pipes 110mm dia, single socketed in any length with rubber ring joints, fixed to walls complete all as specified and as directed. |
| 41 | Fixing only for PVC (SWR) pipes 110mm dia, single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.Note : Old serviceable pipes shall re-used obtained from taking down. |
| 42 | S&F 110mm dia PVC (SWR) bends of any radius complete all as specified and as directed. |
| 43 | Demolition of RCC of any description and in any position, not otherwise specifically provided for complete all as specified and as directed. |
| 44 | M&L for RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 45 | M&L for TMT bars of size 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 46 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (horizontal or sloping) in rough finished flat surfaces complete all as specified and as directedNOTE: The contract sum shall be derieved by deducting the amount shown in Schedule of Credit attached to this tender from total amount of Schedule \"A\"/BOQ. |