| 1 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as required, all complete as per the direction of the Engineer-in-charge. |
| 2 | Dismantling tile work ofthickness of tiles 10 mm to 25 mm in floors including skirting laid in cement mortar and Carpets laid over floor iincluding stacking material within 50 metres lead as directed by Engineer-in-charge. |
| 3 | Taking out existing wooden/Aluminium door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 4 | Providing sun control film to the window glass panes of best quality approved make and colour including cutting into sizes fixing in position completecompletewith cost of materials, labour, scaffolding, tools and plants all as per specifications and directions of Engineer-in-charge. |
| 5 | Providing and fixing f alse ceiling 15 mm thick tegular edged light weight calcium silicate false ceiling tiles.at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on inter-locking metalT-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising ofmain-Trunners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm andsecondary intermediate cross-Tof size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 6 | Supplying & fixing of 2 feet X 2 feet, 33/36W (approx) LED panel lightalongwith suitable driver in false ceiling including necessary connections from the nearby point wiring by providing suitable length of3X1.5Sq.mm FRLS Wires in flexible conduit not morethan 3 mtrs for each light as per the instruction and directions of E-I-C. This includes cost of materials, transport, labour, tools & plants, ladder, taxes etc completeas directed by the Engineer-in-charge |
| 7 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 8 | Providing and fixing Double charged Glazed VITRIFIED floor tiles of approved make of sizes(600mm x600mm) conforming to IS 15622 inall colours and shades laid over a bed of minimum20 mm thick bed of Polymer mortar and jointing with grey cement slurry including grouting with the joints withwhite cement based Tile Grout of approved make and matching shade complete as per patterns, drawings and specifications complete as directed by the Engineer-in-charge |
| 9 | Providing & fixing Roller blinds of approved design ofapproved make. The system shall be chain operated roller system utilising a bi directional wrap spring clutch. Fabric shall be attached to the tube with an adhesive strip. Roller tube shall be extruded aluminum having thickness 1.50 mm and end plugs shall be spring loaded for easier installation complete with removing existing vertical blinds, cost of material, labour, transportaion, and as per specifications and as directed by the Engineer in Charge. |
| 10 | Removing white or colour wash, distemper, external paint by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete all as directed at site including scaffolding, cleaning of the areas.as per specifications and as directed by the Engineer in Charge. |
| 11 | Wall painting with premium acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. The rates also includes preparation of sufaces, filling with putty if required, scaffolding complete as per specifications and as directed by the Engineer-in-charge. |
| 12 | Providing and Painting twocoats of synthetic enamel paint on Steel Surfaces of approved brand and manufacture to give an even shade without primer coat.including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge |
| 13 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 With F.P.S.(non modular) bricks in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : as per specifications and as directed by the Engineer-in-charge |
| 14 | 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand):as per specifications and as directed by the Engineer-in-charge |
| 15 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. as per specifications and as directed by the Engineer-in-charge |
| 16 | Providing and fixing 25 mm thick in wall lining medium density fibre board IS: 14587:1998 marked, Pre-laminated one side decorative lamination and other side and front balancing lamination, with necessary fixing arrangement and screws etc. complete. as per specifications and as directed by the Engineer-in-charge |
| 17 | General terms and Conditions: 1. Contractor shall inspect the site to acquaint with the site as well as security conditions at AMD, Hyderabad. (2).The rates quoted shall include cost of all tools and tackles, manpower including wages, liveries, all wastages and taxes GST, Labour cess, IT, etc., as applicable but exclusive of EPF and ESI are exclusive. EPF and ESI are reimbursable as per relevant clause. (3). Any accident involving labour, construction machinery and person(s) passing vehicle occupants etc. at the work site due to actions of the contractor/his menand/or women will be the responsibility of the contractor. (4).The contractor shall provide all necessary personal protective safety equipments such as safety belt, helmet, safety shoe to all workers engaged on the work and comply with safety code given in the tender. (5). All the samples of materials which are to incorporated in the work shall be got approved by theEngineer -In- charge well in advance. All mandatory tests for materials shall be carried out/doneby the contractor at his cost only. Department will not pay/ reimburse any laboratory testing charges.(6). The contractor is required to pay his employees / labour as per the prevailing minimum wages approvedby State/ Central Govt. The Officer In –Charge or his representative will witness the payment of contractor’s labour and is required to certify that the contractor does not pay less than the minimum wages approved. Payment to the contractor will be released only on such certification from Officer In –Charge. The contractorshall maintain 1. Register of Workmen employed 2. Muster roll 3. Register ofwages etc. (7) Contractor shall quote rates for all items after considering cost of materials and labour components and all such conditions leads, lifts, safety precautions, security restrictions that are necessary for satisfactory completion of work as per instructions and site conditions. Security regulations shall be followed |