Tender For Construction work of Shri Badridas Sanskrit U.M.V. Khaicha Maharajganj - Excavation of Foundation- Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil (DSR-2.6.1) 2 Excavating. Supplying, stacking and filling of local earth (including roylaty) by mechhanical transport upto a lead of 5 km. also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complate for all lift.(2.25A) 3 Sand Filling- Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (DSR-2.27) 4 PCCProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (DSR-4.1.8) 5 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (DSR 2.35.3) 6 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 7 Footing (DSR 5.1.2) 8 Column (DSR 5.1.2) 9 Plinth (DSR 5.1.2) 10 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources). 11 Lintel (DSR 5.3) 12 Slab (DSR 5.3) 13 Beam (DSR 5.3) 14 Column (DSR 5.3) 15 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . Thermo-Mechanically Treated bars of grade Fe-500D or more. 16 upto plinth (DSR 5.22.6) 17 above plinth (DSR 5.22.6 A) 18 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) 19 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR-6.4.2) 20 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 21 Providing & fixing of hold fast for chaukhatsof doors and windows. (DSR-10.31) 22 Door / windows & Staircase grill. (DSR-10.31) 23 Angle iron door chaukhat 40*40*5. (DSR-10.31) 24 TIE ROD 12 MM SQUARE BAR (DSR-10.31) 25 Z-Section Window (DSR-10.31) 26 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (DSR 10.30.1) 27 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.1) 28 Providing & fixing of Sliding door bolts (300x16mm) (DSR 9.62.1) 29 Providing & fixing of tower bolts (250x10mm) (DSR 9.63.1) 30 Providing & fixing of handle 125mm) (DSR 9.66.1) 31 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) (DSR-13.4.2) 32 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) (DSR-13.4.2) 33 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate (11.3.1) 34 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick (11.6.1) 35 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an evenshade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (DSR 13.62.1) 36 Finishing walls with Acrylic smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67ltr/10 sqm over the including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. (DSR 13.46.1) 37 One priming coat ofcement primer and twocoats oil distemper on new work including supply of all materials, labour and tools andplants etc. required for proper completion of the work (DSR 13.41.1) 38 Centering and shuttering including strutting, propping etc. and removal of form: in Foundations, footings, bases of columns, etc. for mass concrete (DSR 5.9.1) 39 Centering and shuttering including strutting, propping etc. and removal of form in Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3) 40 Centering and shuttering including strutting, propping etc. and removal of form in Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR 5.9.5) 41 Centering and shuttering including strutting, propping etc. and removal of form in Columns, Pillars, Piers, Abutments, Posts and Struts (DSR 5.9.6) 42 SANITARY WORK 43 SUB-HEAD I (SANITARY FIXTURES & ACCESSORIES ) 44 Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required : 45 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (17.1.1) 46 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including 47 cutting & making good the walls wherever required. 48 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. (17.7.4) 49 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 50 a) 32mm dia (17.28.2.1) 51 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. (17.31) 52 SUB-HEAD II (SOIL WASTE & VENT PIPES AND FITTINGS ) 53 Providing & fixing soil, waste and vent pipes. 54 a) 100mm dia centrifugally cast iron S & S pipe. (17.35.1.2) 55 b)75mm dia centrifugally cast iron S & S pipe. (17.35.2.2) 56 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 57 a) 100mm (17.58.1) 58 b) 75mm (17.58.2) 59 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal 60 size).Including cost of cutting holes & making good the walls etc. 61 a) for 100mm dia pipe. (17.37.1) 62 b) for 75mm dia pipe. (17.37.2) 63 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 64 a) 100mm inlet & 75mm outlet. (17.60.2.1) 65 Providing & fixingcast iron coller. 66 a) 100mm dia. (17.57.1.2) 67 b)75mm dia. (17.57.2.2) 68 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 69 a) 110mm diameter (12.41.2) 70 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 71 a) 110mm (12.43.2) 72 SUB-HEAD III (WATER SUPPLY PIPES AND FITTINGS) 73 Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. 74 (internal work) 75 Exposed on wall 76 a) 25mm dia nominal bore (medium duty) (18.10.3) 77 b) 32mm dia nominal bore (medium duty) (18.10.4) 78 Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall. 79 a) 15mm dia nominal bore (18.11.1) 80 b) 20mm dia nominal bore (18.11.2) 81 Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 82 a) 15mm dia nominal bore. (18.40.1) 83 b) 20mm dia nominal bore. (18.40.2) 84 c) 25mm dia nominal bore. (18.40.3) 85 d) 32mm dia nominal bore. (18.40.4) 86 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 87 a) 15mm nominal bore (18.21.2.1) 88 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 89 a) 15mm nominal bore (18.49.1) 90 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 91 a) 15mm nominal bore (18.53.1) 92 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 93 a) 25mm. Nominal bore (18.18.3) 94 Providing and fixing gun metal gate valve with wheel of approved quality. 95 a) 25mm dia nominal bore (18.17.1) 96 b) 32mm dia nominal bore (18.17.2) 97 c) 40mm dia nominal bore (18.17.3) 98 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 99 Capacity 11000 litre (18.48) 100 SUB-HEAD IV (SCHEDULE OF QUANTITIES FOR EXTERNAL SEWERAGE SYSTEM) 101 Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, 102 in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. 103 a) Pipes 80mm to 300mm diameter. (2.10.1.2) 104 Providing, laying and joining glazed stone ware pipes grade Awith stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 105 a) 100mm diameter (19.1.1) 106 b) 150mm diameter (19.1.2) 107 Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 108 a) 100mm diameterS.W. Pipe (19.2.1) 109 b) 150mm diameterS.W. Pipe (19.2.2) 110 NON SCHEDULE ITEMS :- 111 Providing and Fixing C.P. brass Ablution health faucet assembly with 1.2 m long braided PVC hose with mounting bracket fixed on wall complete.[FOR EWC] (MR) 112 Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to IS:8931. 15 mm nominal bore (MR) 113 ELECTRICAL WORK 114 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (1.1) 115 Group C (1.10.3) 116 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (1.12) 117 Submains : 118 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (1.14) 119 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (1.14.1) 120 2 X 4 sq. mm + 1 X 4 sq. mm earth wire (1.14.3) 121 4 X 6 sq. mm + 2 X 6 sq. mm earth wire (1.14.9) 122 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (1.21) 123 20 mm (1.21.1) 124 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (1.24) 125 5/6 A switch (1.24.1) 126 3 pin 5/6 A socket outlet (1.24.4) 127 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (1.25) 128 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (1.26) 129 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. (1.27) 130 1 or 2 Module (75mmX75mm) (1.27.1) 131 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (1.31) 132 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (1.5) 133 Upto 450 mm sweep (1.50.1) 134 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) (1.57) 135 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (2.4) 136 4 way (4 + 12), Double door (2.4.1) 137 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (2.1) 138 Single pole (2.10.1) 139 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. (2.11) 140 Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A (M.R.) 141 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A (M.R.) 142 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (2.15) 143 40 A (2.15.1) 144 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. (2.21) 145 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (5.4) 146 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) (5.9) 147 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. (5.12) 148 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (19.1) 149 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA (NS) 150 Supply and fixing of LED Tube Light fitting suitable for up to 1X22 Watt LED Tube Light on surface complete in all Respect. (NS) 151 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. (NS) 152 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 153 size 25 sq mm x 3-1/2core(MR) 154 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable 155 size 25 sq mm x 3-1/2core (MR) 156 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 157 size 25 sq mm (MR) 158 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work.(MR) 159 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. (NS) 160 BOUNDARY WALL 161 Excavation of Foundation-Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil (DSR-2.6.1) 162 PCCProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (DSR-4.1.8) 163 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) DSR-6.1.1) (DSR 6.1.1) 164 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level (DSR 5.1.2) 165 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources). (DSR 5.3) 166 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR-6.4.1) 167 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . Thermo-Mechanically Treated bars of grade Fe-500D or more. 168 upto plinth (DSR 5.22.6) 169 above plinth (DSR 5.22.6 A) 170 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) (DSR-13.4.1) 171 Finishing walls with Acrylic smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67ltr/10 sqm over the including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. (DSR 13.46.1) 172 Centering and shuttering including strutting, propping etc. and removal of form: in in Lintels, beams, plinth beams, girders, bressumers and cantilevers(DSR 5.9.5)