| 1 | M&L 75mm thick cement concrete (1:4:8) type D2 as sub base to floor as specified. |
| 2 | M&L sand filling under floors or in foundations including watering and consolidation all as specified and directed by Engr-in-Charge. |
| 3 | M&L machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, complete all as specified and directed by Engr-in-Charge. |
| 4 | Supply and fixing rotational moulded HDPE water storage tanks (Cylindrical vertical closed top), double wall construction, hoisted and fixed in position or placed in position inside or outside the building, connecting up pipes and securing access covers complete, 1000 Ltr capacity, complete all as specified and directed by Engr-in-charge |
| 5 | Excavation in trenches n exc 1.5m wide and getting out in hard/ dence soil |
| 6 | M&L for cement concrete type D-2 1:4:8 (Using 40mm graded aggregate as in fdn) |
| 7 | M&L walling of random rubble uncoursed well bonded and solidly hearted built in CM 1:6 brought upto course |
| 8 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick |
| 9 | Removal of surplus soil to a distance exceeding 50 mtr and depositing where directed at a level not exceeding and depositing where directed at a level not exceeding 1.5m above the starting point. |
| 10 | Point wiring with multi-stranded copper conductor PVC insulated and unsheathed cable in PVC casing and capping, 1.5 Sqmm with all fittings/accessories and including 1.5 Sqmm PVC insulated copper earth wire connectedto common earth including closed recessed wooden terminal Boxes of suitable size made of 2nd class hard wood for mounting switches, sockets etc with 3mm thick laminated sheet cover for one light point or bell/buzzer pointcontrolled by one switch, complete. |
| 11 | Description all as per item No. 10.00 here-in-before but using 4 Sq mm single core copper conductor cable of multistranded PVC insulated unsheathed 1100 Volts grade for industrial plug socket. point including running of 2.5 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 12 | Switch piano flush type 5 Amps, single pole one way. |
| 13 | Switch socket combination 2 in 1,5 and 15 Ampsflush type. |
| 14 | Ceiling rose surface bakelite 65x50mm, two to three terminals. |
| 15 | MCB, single pole, 5to 32 Amp, 240V, 10KA. |
| 16 | S&F 1100 volts grade heavy duty 10sqmm 2 core flat cableb PVC insulated aluminium stranded conductor,served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire withtwo single core cable complete all as specified. |
| 17 | Supply and fixing LED 18 Watt Tubelightfitting decorative ultra slim square profile linearwith extruded polycarbonateenvironment friendly. Make Havells Cat partLUMILINEPLUSBS18WLED865SPCSS OR equivalent in WIPRO/PHILIPS |
| 18 | Supply & fixing LED building security light 45 watt energy efficient with bracket,suitable dia pipe for fixingthe street light in wall all as directed. Make Havells Cat part No. ENDURAPERLINEOSL60WLED75PASYTOPC or equivalent in PHILIPS/WIPRO |
| 19 | Supply and fixing Exhaust fan with grillsmetallic without regulator of sweep 300 mm single phase 250 volts AC supply heavy duty including all fixing material and arrangements, provision of 2 way PVC connector, copper bunched flexible cable 23/0.0076 twin twisted PVC insulated cable from ceiling rose/connector to fanall as specified and directed. |
| 20 | Supply and installation electrically operated Boom Barrier of length 6 Meters with height of boom approximately at 875 mm from ground, housing dimensions 400 x 400 x 1065 mm with a thickness of 2 mm, boom dimension 90 x 32 mm, IP54 controller protection, rating 230 V (AC), 50/60 HZ, 24 V (DC) motor power supply, 200 W power and opening /closing time of 2 to 4 Secs, 100% intense use duty cycle, 20 degree Celsius to +55 degree Celsius operating temperature, 5 million cycle MCBF, including necessary foundation / fixing arrangments, optical beam sensor access control operation, high range receiver, high range remote control, push button switch for barrier operation, ABS brake control system, photosensor for human safety, loop detector for detecting presence of vehicle and reverse barrier movement, bar with protective rubber profile,flash lights, provision for manual operation in case of power failure through barrier locks and all connected accessories provided as per OEM\"s installation instructions, complete all as specified and as directed.including service cable as per side requireement.Make: M/s Godrej & Boyce Mfg Co., Model: GVB6 or equivalent in M/s Gandhi Automations Pvt Ltd as approved by Engg-in-Charge.Note : The rate quoted by the tenderer shall include for supply, installations, testing, commissioning of Boom barrier including necessary foundation and making good to disturbed surfaces as per existing and other accessories as per OEM\"s instructions, cabling of required connection from power point provided by the department and necessary operational training for users/department personnel. |
| 21 | Supply and fixing MCB DB 4 way , double door, TPN, 415 volts with 200 Amps bus bar complete all as specified and as directed |
| 22 | Supply and fixing MCB TPN upto 63 Amps, 415 volts with breaking capacity 10 KA complete all as specified and as directed. |
| 23 | Supply and fixing MCB TP 6 to 32 Amps, 415 vols with breaking capacity 10 KA complete all as specified and as directed. |
| 24 | Earthing complete with galvanised steel earth plate electrode 600mm x 600mm and 6mm thick buried directly in ground not less than 2.25 mtr deep belownormal ground level with top edge of plate not less than 1.5 metres below normal ground level, connected to the Galvanized iron earth wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron protected by provision of G I light grade pipe 40mm bore including provision of concrete pit in PCC 1:2:4 type B1 using 20mm grade stone aggregate with 40mm thick cover of RCC 1:2:4 reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs two number and with 6mm dia MS bar handle made to shape and GI medium grade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge of earth plate, common salt and charcoal filling, test point made out of 40mmx8mm flat iron with fixing arrangement funnel wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50M all as per electric plate No 5 of SSR Part-I conected to earth test point as specified or indicated including testing on completion. |
| 25 | Note : Deduction for amount of Rs. 0.00 as listed in Schedule \"A\" Part-II (Schedule of Credit) shall be made while awarding of contract. |