| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group C |
| 2 | Wiring for light point /fan point /exhaust fan point /call ball point with 1.5sq.mm FRLS PVC installed copper conductor single core cable in surface / recessed PVC conduit, with piano type switch phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5sq.mm. FRLS PVC installed copper conductor single core cable etc as required. Group C |
| 3 | Supply and fixing of following piano type swich/ socket on the existing switch box/ cover including connection etc as required. |
| 4 | (a) 5/6amps switch |
| 5 | (b)15/16 amps switch |
| 6 | © 3 pin 5/6 amps socket outlet |
| 7 | (d) 6 pin 15/16 amps socket outlet |
| 8 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessedPVC conduit as required. |
| 9 | (a)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 10 | (b)2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 11 | (c)2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 12 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 13 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A |
| 14 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 200 mm X 300 mm X 100 mm deep |
| 15 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(a) 20 mm |
| 16 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required |
| 17 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 Way Double Door |
| 18 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 19 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as reqd. |
| 20 | Supply of 12\"(300 mm)sweep 1400 rpm heavy duty Exaust Fan complete with ring, blade etc as required. ISI marked. |
| 21 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 22 | S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95 |
| 23 | providing and fixingABC (Aluminum Phosphate) power type fireextingusher of 6kgscapacity complete in all respect with ISI marked i/c fixingarrangement etc.as reqd. |
| 24 | providing and fixing 4.5 Kg Co2 type fire extingushersqeeze grip type trolly wheel as well mounting type complete in all respect with ISI marki.cfixing arrangement etc. as reqd. |
| 25 | Supplying, testing and Commissioning of 1 hp rating self priming monoblock pumping set suitable for operation on 230 Volt Single phase AC Supply Complete as rqd. |
| 26 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 27 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2X10 sqmm |
| 28 | Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size in the existingmasonry open duct as required(a) Upto 35 sq. mm |
| 29 | Supplying & Installation of Hot Cold & Normal Floor Standing Top Loading Water dispenser with Cooling Cabinet Fridge cold water storage capacity up to 3.5 ltr with hot water storage capacity up to 1 ltr as required. |
| 30 | S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V |
| 31 | Supply, Installation, Testing and Commissioning of 1.5 Ton, 5 Star rated Inverter Split air conditioner with rotary compressor (R32 Refrigerant) having copper condenser complete with outdoor unit as required. |
| 32 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 33 | S/I/T/C of copper pipe for split AC |
| 34 | Extra Drain pipe |
| 35 | SITC of STAND for split AC |