| 1 | M&L for one coat of white wash on old concrete wall surfaces including preparation of surfaces all as directed by the Engineer–in-Charge. |
| 2 | M&L for preparation of old painted surface of iron post stones, concrete, asbestos cement or plastered of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified & directed. |
| 3 | Rough excavation n exc 1.5m deep and getting out in soft/loose soil and removing to a distanceexc 50 m but n exc 100 m all as specified & directed by Engineer-in-Charge. |
| 4 | Screening the excavetedsoil by mechanical instrument and removing hard objects such as stone ,metal pieces including removing hard objects at least 500m away from the site as completed and directed by Engineer-in-Charge. |
| 5 | Spreding and levelling of soilin layers n exc 25cm thick all as directed by Engineer-in-Charge. |
| 6 | Supply and stacking new HDPE bags ofquality with inner laminated layers white/colour empty bags shall not be less than 90 gm per bag and filled with locally available sand / soil (obtained from defence land) approximate quantity 1.2 cuft in each bags including tying properly with jute coir and stacking neatly at site, in pyramids circle or any other shape and for any height all including taking out and removing old unserviciable HDPE bags complete all as specified & directed. |
| 7 | Loosing of any type of soil to average depth 25cmby removing the stone metal piecesof sizeexc 50 mm and depositingto a distance exc 150 m but n exc 500 m from FG target area, gunnery area, including leveling surfaces after loosing the earth by mechanical earths moversor tractorsor any other devices at the disaretion of contractor all as specified and directed by Engineer-in-Charge. |
| 8 | Removing of localised blockage by cleaning gully trap, floor / nahni trap, soil waste pipe, WC chocked, etc including first Manhole and removing sludge water / waste upto 50 mtr from distance and burring the same in pit complete. |
| 9 | Cleaning of septic tank of 50 users capacity by bailing out taking out sludge and removing the sludge by pump or other mechanical means to a distance exceeding 1.5 Km but not exceeding 2.00 Km from the camp area and including removing stone patti/RCC cover slab and refixing, cleaning frequency as per requirement, complete all as directed. |
| 10 | Cleaning of manhole of any capacity and depth by excavating sewage wet/dry soil in foul condition and removing the waste in covered vehicles outside MD land by taking all necessary precautions and including pumping out fluid, cleaning of sludge from manhole, placing the cover of manhole in position and removing the sludge in covered van/trolley out side the MD land, complete all as specified and directed. |
| 11 | Cleaning of sewage lineof any dia and depth by excavating sewage wet/dry soil in foul condition and removing the waste in covered vehicles outside MD land by taking all necessary precautions and including pumping out fluid, cleaning of sludge from manhole, placing the cover of manhole in position and removing the sludge in covered van/trolley out side the MD land, complete all as specified and directed. |
| 12 | Demolition of cement concrete (unreinforced) above ground floorsnot exceeding 15 cm thickness complete all as specified and directed. |
| 13 | M&L for machine pressed precast concrete interlocking paver block rubber moulding any shape and size with grey cement and pigment cnfirming to IS-15658-2006 of 60 mm thickness, M-35 grade over and25mm thick sand/stone dust complete all as specified & directed by Engineer-in-Charge. (Sand cusion paid separetely) |
| 14 | M&L for chequered cement concrete tiles 300mm X. 300mm x 20-25mm thick, set, jointed and pointed in near cement slurry in floor with grey cement and pigment including20mm thick screed bed in CM (1:6) complete all as specified and directed. |
| 15 | M&L for sand filling under floors or in cushion layer complete all as specified and directed. |
| 16 | M&L for 75 mm thick Cement concrete1:4:8, type D-2 ( using 40mm graded stone aggregate)as in sub-base/hard standing complete all as specified and directed. |
| 17 | S&F factory made SFRC manhole covers with rectangular frame of size 44\"x26\" MD-10 fixed at top at site complete all as specified and directed. |
| 18 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 19 | M&L for preparation of new surface of concrete as in road side kerb stone and applying two coat of water based synthetic enamel paint of approved different tint complete all as specified and directed. |
| 20 | S&F in repair PVC (SWR) floor trap of 75 mm outlet plain with grating including jointing with solvent cement complete all as specified and directed. |
| 21 | S&F in repair PVC (SWR) 110 mm dia pipes single socketed in any length with rubber ring joints laid in trenches/floor or fixed to wallsincluding digging and making good as existing complete all as specified and directed. |
| 22 | S&F in repair 110mm dia PVC (SWR) bend any radius with access door complete all as specified and directed. |
| 23 | S&F in repair 110mm dia PVC (SWR) bend any radius complete all as specified and directed. |
| 24 | S&F in repair 110 mm PVC (SWR) Junction single (Single T) equal or unequal with access door complete all as specified and directed. |
| 25 | S&F in repair 110mm dia PVC (SWR)vent cowl complete all as specified and directed. |
| 26 | S&F in repair PVC (SWR) 75 mm dia pipes single socketed, in any length with rubber ring joints,laid in trenches/floor or fixed to wallsincluding digging and making good as existing complete all as specified and directed. |
| 27 | S&F in repair 75 mm PVC (SWR) Junction single (Single T) equal or unequal with access door complete all as specified and directed. |
| 28 | S&F in repair 75mm dia PVC (SWR) bend any radius complete all as specified and directed. |
| 29 | S&F in repair 75mm dia PVC (SWR) bend any radius with access door complete all as specified and directed. |
| 30 | S&F in repair 75 mm PVC (SWR) Junction single (Single Y) equal or unequal with access door complete all as specified and directed. |
| 31 | S&F in repair Stack clamps out of 50 mm by 5 mm flat iron and 16 mmm dia round iron stays.including bolts and nuts and securing ends of stays to wall or roof in dia 110mm pipe complete all as specified and directed. |
| 32 | S&F in repair Stack clamps out of 50 mm by 5 mm flat iron and 16 mmm dia round iron stays.including bolts and nuts and securing ends of stays to wall or roof in dia 75 mm pipe complete all as specified and directed. |
| 33 | Raking out old, decayed cement mortar pointing to boulders/stone pitching, stone paving in horizontal/sloped surface and washing the joints, removing rubbish off the premises etc complete all as specified and directed. |
| 34 | M&L for flush pointing in CM 1:4 to boulders/stone pitching, stone paving in horizontal/sloped surface complete all as specified and directed. |
| 35 | M&L for coloured industrial tiles(Jhonson endura and Equivalent to make) 300mm X. 300mm x 10 mm thick, conforing to is laidset, jointed and pointed in near cement slurry in floor with grey cement and pigment including15mm thick screed bed in CM (1:6) complete all as specified and directed. |