Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-04-2025 | Amendment1 | BOQ | 16-04-2025 |
| Sl. No. | Item Description |
| 1 | Dismantling of Asbestos cement (corrugatedor semi corrugated ) sheets in roof covering all as specified and as directed. |
| 2 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed. |
| 3 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding/ridges etc , fixed with self tapping screws all as specified and as directed. |
| 4 | Dismantlingtimber scantlings 40 Sq. cm and over in section and in any position in unframed work all as specified and as directed. |
| 5 | M&L 2nd class hardwood, scantlings, wrought, timber fixed, complete all as specified and as directed. |
| 6 | M&L preparation of new wooden surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer including anty termite treatment all as specified and as directed. |
| 7 | Dismantling structural steel work including doors,window,gates but excluding framed truss etc all as specified and as directed. |
| 8 | S & F roof/bottom plates with sleeve pieces riveted or welded thereto, and similar roof and ceiling connections all as specified and as directed. |
| 9 | S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 all as specified and as directed. |
| 10 | S & F for rolled mild steel work in roof trusses (framed), trussed, purlins crane gantries ,Post, rafts and fastening and heavy brackets framming (beams tee,angle channel and or flat sections) including distance pieces, cleat nut bolts etc quality confirmingto Fe-290 (Gde E-165) all as specified and as directed. |
| 11 | M&L for preparation of old painted surface applying a coat of synthetic enamel painton steel surface all as specified as directed. |
| 12 | M&L for preparation of new painted surface applying a coat of synthetic enamel painton steel surface all as specified as directed. |
| 13 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing all as specified and as directed. |
| 14 | M&L GI wire netting of 0.90 mm dia and 12 mm mesh lathing to wood or metal studding, joists, etc in walls, ceilings etc. including all laps, cutting and waste fixed with tinned tacks of wire staples etc complete all as specified and directed. |
| 15 | M&L rendering 15 mm thickon one side oflathing in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement all as specified and directed. |
| 16 | M&L rendering 10 mm thickon other side oflathing in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement all as specified and directed. |
| 17 | Taking down cement plaster including racking out joints hacking for key, scrubbing down with water all as specified and as directed. |
| 18 | M&L for rendering 15 mm thick on Fair face of Externalwalls of bricksurface in two layers (10 mm and 5 mm thick) in cement mortar in 1:4 using water proofing compound in top layer all as specified and as directed. Note : Water proofing compound measured separately. |
| 19 | M&L for rendering 10 mm thick on brick wall the fair face CM 1:6 finished even and smooth without using extra cement all as specified and as directed.. |
| 20 | Supply only WPC of approved make all as specified and as directed. |
| 21 | M&L fortwo coat of distemper oil emulsion after preparation of new plasteredsurfaces of wall over a coat of clearcholle primar all as specified and as directed. |
| 22 | M&L for Twocoat of cement basepaint after preparation of new plasteredsurfaces over a coat of alkali resistant cement primar of walls all as specified and as directed. |
| 23 | M&L fortwo coat of distemper oil emulsion after preparation of old plasteredsurfaces of wall over a coat of clearcholle primar all as specified and as directed. |
| 24 | M&L for Twocoat of cement basepaint after preparation of old plasteredsurfaces over a coat of alkali resistant cement primar of walls all as specified |
| 25 | M&L forpreparationof New decorated surface of wall and applying three coat of white wash all as specified and as directed. |
| 26 | M&L forpreparationof old decorated surface of wall and applying two coat of white wash all as specified and as directed. |
| 27 | Dismantlingwall and ceiling boards ( fibre , pulp, insulationetc ) or insulation boards/ slabs/ blankets , any thickness , including cover fillets. |
| 28 | M&L Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long, grid 605mm x 605mm andcomplete all as specified. |
| 29 | S & F for Anodised aluminium snap grid frame work for false ceiling all as specified and as directed. |
| 30 | M&L for 4mm thickNon asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws all as specified and as directed. |
| 31 | M&L fortwo coat of distemper oil emulsion over newly fixed false ceilingall as specified and as directed. |
| 32 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the permises all as specified and as directed. |
| 33 | M&L for providing non skid ceramic tiles (coloured) 7 to 8mm thick, area of each tile exc. 0.11 but not exc. 0.18 Sqm as in floor set and joint in cement slurry 1:6 CM, jointed & pointed in white or coloured cement to match the surface of the tile all as specified and as directed. |
| 34 | M&L for providing glazed ceramic coloured tiles of size 350x250 x 7mm /450x350x7 mm thick) as in vetical surface set in cement slurry 1: 4 CM jointed & pointed in white or coloured cementto match the surface of tile all as specified and as directed. |
| 35 | M&L for providing non skid ceramic tiles (coloured) 7 to 8mm thick, area of each tile exc. 0.18 but not exc. 0.38 Sqm as in floor set and joint in cement slurry 1:6 CM, jointed & pointed in white or coloured cement to match the surface of the tile all as specified and as directed. |
| 36 | S & F anodised aluminium alloy harrison rails , mild steel , chromium plated with fixing brackets , stops, rollers etc all as specified and as directed. |
| 37 | Demolition of cement concrete (unreinforced) of any description and in any position not other wise specificallyprovided all as specified and as directed. |
| 38 | M&L for providing 75mm thick PCC 1:3:6 type C2 (40mm graded aggregate) as in plinth protection and paving finishing the surface even and smooth without using extra cement all as specified and as directed. |
| 39 | M&L for 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone agg) as in floor finish etc complete all as specified and directed. |
| 40 | S&F 35 mm thick, 2nd class hardwood plain, framed, panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified and as directed. |
| 41 | S&F 35mm thick skeliton/gauzed shutteropen rebated and prepared to receive glass gauged etc(with sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24(a), supplied and fitted to chowkats all as specified and as directed. |
| 42 | S & F in repair for galvanised mild steel wire cloth 0.63mm nominal dia of wire and average width of aparture 1.00mm and fixed with stainless steel wire staples in window and door including wooden bids as fixed in repair as old door/window all as specified and as directed. |
| 43 | Taking down chowkats or frame n exc 1.5 sqmwith shutter (with out taking off shutter from frame) all as specified and remooving from site all as specified and as directed. |
| 44 | S & F steel frames for doors(105 x 60 ) mm with one or more rebates including necessary fixing lugs , hinges , lock strike plate ,etc., complete ,as specified, supplied and fixed all as specified and as directed. |
| 45 | S&F 2nd class hard wood plain solid, straight chowkats and frames wrought,frame rebated on the solid,rounded or chamfered,put together with glue pinned at joints,supplied and fix all as specified and as directed. |
| 46 | S&F solid PVC door frames of size 50mm x 47mm made out of 5mm plain cover fillet colour PVC sheet reinforced with MS square tube for toilet all as specified and as directed. |
| 47 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails, M.S frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either toside and as gap insert for top rail & bottom rail panelling of plain colour PVC sheet to be fitted in M.S frame welded/sealed to stiles and rails with suitable PVC sheet beading and jointed together with solvent cement. Supplying and fixing in the frame at site as specified of drawing all as specified and as directed. |
| 48 | Taking down window chowkats or frame exc 1.5 sqm but n exc 4 (without taking off shutters from the frame)all as specified and as directed remooving from site but with shutters with out takings off the shutters from the frame all as specified and as directed. |
| 49 | Taking down Shutters with chaukhat of any description n exc 1sq. m eachall as specified and as directed all as specified and as directed. |
| 50 | Refixing of Shutters of any descriptionbut exc 1 sq. m and n exc 2 sq. m each all as specified and as directed. |
| 51 | S & F 4.0 mm sheet glass, ordinary quality in squares exc 0.5 Sqm each pane all as specified and as directed. |
| 52 | S&F for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire staples in window and dooras innew door/window. |
| 53 | S&F 2nd class hardwood small fittings such as brackets of any type of door and window stopper including all necessary articles n.exc 2.00 cum each all as specified and as directed. |
| 54 | S&F Door closer hydraulically regulated, designation No. 3, universal type, suitablefor door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg Aluminium die cast body fixed In repair all as per specified and as directed. |
| 55 | M&L preparation of Old wooden surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer all as specified and as directed. |
| 56 | M&L forPCC 1:3:6 type C1 as in hold fast blocks incl. necessary form work all as specified and as directed. |
| 57 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-16 all as speciefied and as directed. |
| 58 | S&F 100mm size butt hinges, Extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed,type B-21 fixed in repair and brass/bronze pin is provided in lieu of mild steel hinge pin all as specified as directed. |
| 59 | S&F 125mm size aluminium handle cast typeanodised complete all as specified and as directed. |
| 60 | S&F 200mm long aluminium anodised barrel tower bolt of extruded section conplete all as specified and as directed. |
| 61 | S & F Aluminium alloy ,anodised sliding door bolt with hasp , staple (bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast- aluminium alloy ,length of bolt of 250 mm all as specified and as directed. |
| 62 | S&F Soap dish, steel, Aproximate size 160x 160x9mm all as specified and directed. |
| 63 | Chlorinated Polyethylene Chloride (CPVC) pipe 15 mm outside dia, SDR 11 (IS 15778) & plain CPVC SDR 11 including all special fittings (brass threaded elbow, tee, unions, etc.) polypropylenerandom fitting on wall/ceiling laying in floor complete all as specified and as directed. |
| 64 | Suppling and fixing CPVC Gate valve for 20 mm dia outerpipe complete all as specified and as directed. |
| 65 | Supply and Fixbib taps cast copper alloy, fancy type CP with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferule and fixed of size 15mm bore all as specified and as directed. |
| 66 | S&F 15mmstop / angle valves (concealed type), chromium plated, long sunk and cup, screwed both ends for iron pipe or for unions and fixed all as specified and as directed. |
| 67 | Supply and fix in repairs PVC flushing cistern 10 ltr capacity high level with inlet ball valve float chain and pull and brackets and flush pipe 32mm dia PVC pipe complete all as specified and and as directed. |
| 68 | S&F in repair Vitreous china premium/ 1st quality wash down water closetEWC/white/ ivory / off white ( Closed pattern incl all necessories like rag bolts / gel gasket etc. including flushing cistern & flush pipe) complete in all respect all as specified and as directed.. |
| 69 | S&Fin repair for vitreous china squatting pan \"Orissa\" pattern, size 580x440mm white, with integral foot rests (excluding flushing cistern and flush pipe)including connection to trap, and to flushing pipe, anti-syphonage pipe etccomplete including making good to floors with PCC bedding (1:5:10) type E2 using 40mm nominal brick ballast and connection to trap with cement mortar all as specified, and making good to floor including demilition of PCC / Lime concrete bedding existing pan complete all as specified and as directed. |
| 70 | S&F in repair for Vitreous China Urinals, bowl type white (excluding flushing cistern but including flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and as directed. |
| 71 | S & Ftowel rails 60 cm long brass chromium plated 20mm dia with brackets fixed to walls in repairs all as specified and as directed. |
| 72 | S & F 600 x 450mm size mirror of selected quality glass 5mm thick with PVC frame including key hole plates for hanging and fixed to wall with chromium plated screws all as specified and directed. |
| 73 | S & F Shower rose fancy type chromium plated 125 mm size with swivel joints for fixing to 15 mm bore GI pipe or union all as specified and as directed. |
| 74 | S & F LDPE pipe as waste pipe 32 mm dia for wash basin all as specified and as directed. |
| 75 | S&F in repairs PVC (SWR) floor trap plain with grating incl jointing with solvent cement of 75mm dia all as specified and as directed. |
| 76 | S&F in repairs 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls all as specified and as directed. |
| 77 | S&F in repairs 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls |
| 78 | S&F in repairs 110mm PVC (SWR)pipes single socketed in any length with rubber ring joints,laid in trenches all as specified and as directed. |
| 79 | S&F in repairs 75mm PVC (SWR)pipes single socketed in any length with rubber ring joints,laid in trenches all as specified and as directed. |
| 80 | S&F for (SWR) junction single(single T)equal provided with access door 75mm bore all as specified and as directed. |
| 81 | S&F for (SWR) junction single(single T)equal provided with access door but of 110mm bore all as specified and as directed. |
| 82 | S&FPVC (SWR)bends any radius of 75mm bore all as specified and as directed. |
| 83 | S&FPVC (SWR)bends any radius of but of 110mm bore all as specified and as directed. |
| 84 | S&FPVC (SWR)vent cowl of 110mm bore all as specified and as directed. |
| 85 | S&F in repair pillar taps of size 15mm, chromium plated fancy type cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered \"Hot\" or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and as directed. |
| 86 | S&F for 20 mm bore, Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed. |
| 87 | Dismantling of water tank Capacity exc 250 not exc 500 Ltrs and removing to store complete all as specified and as directed |
| 88 | Dismantling of water tank Capacity exc 500 not exc 1000 Ltrs and removing to store complete all as specified and as directed |
| 89 | Hoisting and Fixing of rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 ltrs hoisted and fixed in position specified in SSR Part I complete all as specified and as directed. |
| 90 | Hoisting and Fixing of rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 ltrs hoisted and fixed in position specified in SSR Part I complete all as specified and as directed. |
| 91 | Demolitionof stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floor, aprons etc all as specified and as directed. |
| 92 | M&Lfor 20 mm thick Granite (of any type) work (table rubbled and polished) in steps, Jambs, Pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm screed complete all as specified and directed |
| 93 | S&F for anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and as directed. |
| 94 | S&F powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified complete all as specified and as directed. |
| 95 | S&F 4 mm thick sheet of frosted glass ordinary quality and glazing with oil putty and steel beads in square n.exe 0.50sqm in each pane all as specified and as directed. |
| 96 | M & L for Brass CP mixer for mixing hot & cold water screwed down for CPVC pipe and fixed all as specified and as directed. |
| 97 | M&L for RCCM25 (using 20 mm graded aggregates) inChajjas any thickness above top of footing , roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed. |
| 98 | Demolition of brick work in cement mortar or cement lime mortar all as specified and as directed. |
| 99 | M&L brick work with sub class B bricks, straight or curved on plan exc 6 M mean radius, built in cement mortar 1:6 all as specified and as directed. |
| 100 | Demolition of cement concrete(reinforced) of any description and in any position not otherwise specifically provided for all as specified and as directed. |
| 101 | M & L for RCC 1: 11/2 : 3 (nominal mix) type A1 20mm graded aggregate as in slabs including reinforcement bar as requiredstaging for water tanks etc all as specified and as directed. |
| 102 | S & F in repair vitreous china wash hand basin white flat back size 550x 400mm excluding taps, waste chain and plug and porcelain stopper including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe all as specified and as directed. |
| 103 | Taking down carefully unserviceable aluminium/copperpoint wiring (light, fan, socket or power) complete, including unserviceable fitting such as switches, ceiling roses, pendants, regulators, sockets, etc and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 104 | Taking down unserviceable sub-main wiring any type withrigid steelconduits/PVC Conduits/PVC casing-caping complete all as specified and directed. |
| 105 | M&L point wiring with 1.5 Sqmm (nominal area), PVC insulated FRLSH, multistranded, single core, sheathed, copper conductor cables drawn throughPVC casing cappingnot less than 20mm dia with all fittings and accessories (like Tee, bend etc.) complete for Phase, neutral and earth wire connecting to common earth point including PVC terminal box fixedon walls for housing switches, sockets, regulators, etc all as specified and as directed. |
| 106 | Description as per Ser item No105 here-in-before but one 5 Amps, 3/5 pin socket outlet on the same board with other switches complete all as specified and directed. |
| 107 | Description as per Ser item No105 here-in-before but for one 3/5 pin Switch socket combination, 5 Amps on Independent board complete all as specified and directed. |
| 108 | Description as per Ser item No105 here-in-before but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 15 Amps switch socket combination on Independent board complete all as specified and directed. |
| 109 | M & L for Sub main wiring with two runs of 4 sqmm single core cable FRLSH PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn throughPVC casing cappingnot less than 20mm dia with all fittings and accessories (like Tee, bend etc.)etc including4 sqmm (nominal area) single core, FRLSH PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth pointcomplete all as specified and as directed by Engineer-in-charge. (Note : (a)PVC Casing-caping, two run cables and one run of earth wire will be measured as one length. (b) All incoming and outgoing cable shall beconnected by using proper lugs & sockets.) |
| 110 | S&F switch piano, 5 Amp single pole, flush type one way 230 volts complete all as specified and directed. |
| 111 | S & F Bell push, flush type, 5 Amps 230 Volts, complete all as specified and directed. |
| 112 | S & F Socket outlet, 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and directed. |
| 113 | S&F Switch socket combination, 2 in 1,5 Amps,flush type, 240 volt complete all as specified & directed. |
| 114 | S&F Switch socket combination,5A/16A, 5 in 1, 240 volts, flush type complete all as specified & directed. |
| 115 | S & F call bell / Buzzer, Ding Dong AC. 230 volts, single pole all as specified and directed. |
| 116 | S & Flamp holder, insulated body with back plate suitable for batten fittings all as specified and directed. |
| 117 | S & F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and directed. |
| 118 | S&F in repair Stepped type electronic fan regulator flush type230 volt 5 speed control and connecting up and fix position , complete all as specified & directed. |
| 119 | S & F new 18/20 W surface and wall mounted LED batten with Extruded aluminium housing having efficiency 125 lm/Wand integrated driver all as specified and directed. (Make: Crompron , Cat No.CCS-100-20-65-HL2-DP-NWH or equivalent make from list of makes). |
| 120 | S&F 35 watt Supply and fixing LED street light fitting 35 Watt 230 V AC having efficiency 120lm/W and inclding 10 KV SPD outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection connected by 2.5 Sqmm wire complete all as specified & directed. |
| 121 | S&F 10W,LED, Energy saving new generation bulk head luminaire with opal diffuser including lamp including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Havells Cat part no- RUGBYGENXFTS10WLED865SSYMBOPC, or equivalent make from list of makes). |
| 122 | Taking down unserviceable main switches, DBs, bus bars chambers including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified anddirected. |
| 123 | S & F Factory made board distribution (DB)Double Door in sheet steel enclosure with common bus bar at incomming end, TPN,4 way, 240 Volts , 200 amps suitable for housing MCBs complete all as specified and directed. |
| 124 | S & F Factory made board distribution (DB)Double Door in sheet steel enclosure with common bus bar at incomming end, SPN,8 way, 240 Volts , 200 amps suitable for housing MCBs complete all as specified and directed. |
| 125 | S & F MCB,TPN, 240 Volts,63 Amps, \"C\" Series, 10KA capacity complete all as specified and directed. |
| 126 | S & F MCB,SPN, 240 Volts,6 to 32 Amps, \"C\" Series, 10KA capacity complete all as specified and directed. |
| 127 | S & F MCB, \"C\" Series, SP, 240 Volts,5 to 32 Amps, \"C\" Series, 10KA capacity complete all as specified and directed. (Make: Legrand, Cat No. 408587 to 408595 or equivalent make as per list of manufacturer) |
| 128 | S&FPVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 350 x 300 x 50 mm deep, including taking down old unserviceable one complete all as specified and directed. |
| 129 | M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts,check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steelbars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete inclduing taking down old one/ dismantling complete all as specified and as directed. |
| 130 | Taking down and Refixing of Ceiling fan 1200 mm sweep 230 volt including hanging arrangement of fan under different roof after repairmade out of heavy duty MS rod/flat hook etc making connection by using 3 core 1 Sqmm flexible wire complete. Note- (1) GI Pipe for hanging of ceiling fan measured under relevent item of sch A. |
| 131 | Supply and fixing9W LED Retrofit lampsCode: 9W NEO LED LAMP B22 6500Kof make Surya orequivalent make from list of makes complete including taking down old unsv fittings. |
| 132 | S&F street light bracket fabricated out of GI Tubing light grade 32 mm bore Bend to the shape as directed and of length 1.5 mtrcomplete with mounting MS clamp of flat iron size 40X5mm of suitable length 02 pairs incl nut bolts etc of suitable size, including taking down old corroded one all as specified and directed. |
| 133 | Excavating in trenches n.exc 1.5 mtrs wide and n.exc 1.5 mtr in depth for for laying of cables,foundationetc and getting out in soft/loose soil complete all as specified and directed. |
| 134 | Supply and Laying well burnt bricks, sub class \"B\" bricks laid breath wise along length of cable in trenches for cable protectionlaid for UG cable protection all as specified. |
| 135 | Material and labour for sand cushioning with clean dry sand in trenches for cable protection complete all as specified and as directed.(Note: Thickness after punning down shall be measured for payment) |
| 136 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soft/loose soil complete all as specified and as directed. |
| 137 | Removing excavated materials n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point in soil, complete all as specified and as directed. |
| 138 | Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 4 core including taking out of old unserviceable cable as specified and directed |
| 139 | S & F in repairs, 40mm bore, steel tubes, galvanised, light grade with all fittings and fixtures complete fixed to walls, ceilings, poleusing suitable clamp/holder bat complete all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail