Tender For Construction work of store room in ward number 21 Jalkal Campos - Excavation in foundation in ordinary soil (Loam clay, or sand ) including lift upto 1.5 m & lead up to 30.0 Mtr & including filling,watering and ramming ofexcavated earth in to the trenches or in to the space between the building and the sides of foundataion trenches or in to the plinth and removal & disposal of surplus earth as directed by the Engineer- In-Charge up to a distance of 30.0 Mtr from the foundation trenches .as per DSR-2.8.1 2 E/W in cutting or in embankment including cartage of 5 km lead. DSR2.25a 3 Cement concrete work in 1:4:8 with cement coarse sand and stone ballast including all. DSR-4.1.8 4 M-150 Brick work in 1:6 cement sand mortor etc all complete work in foundation upto plinth level DSR 6.4.2 5 M-150 Brick work in 1:6 cement sand mortor etc all complete work in foundation upto plinth level DSR 6.4.1 6 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. (DSR 5.33 ) M 25 All works above plinth level 7 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.(DSR-5.33 ) All works above plinth level upto floor V level DSR-5.33.2.1 8 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. (DSR-5.33 ) All works above plinth level uptofloor V level DSR-5.33.2.1 9 2.5 cm thik Damp Proof course with cement and approved coarse sand 1:2 with and Including water Proofing material as ordered by the Engineer incharge in the proportion as specified by the manufactures including supply of all materials; labour and tools & plants etc required for proper curing and shuttering as necessary S.I.361 10 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.(DSR-5.33 ) All works above plinth level upto floor V level DSR-5.33.2.1 11 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.(DSR 5.33 ) All works above plinth level uptofloor V level DSR-5.33.2.1 12 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. (DSR-5.33 ) All works above plinth level uptofloor V level DSR-5.33.2.1 13 centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete DSR-5.9.1 14 centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform DSR-5.9.3 15 centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilevers DSR-5.9.5 16 Centering and shuttering including strutting, propping etc. and removal of form for columns, pillars, piers, Abutments, posts and Struts DSR 5.9.6 17 M.S. (TMT Fe500D or more) in Plain Work Such as RCC or RB Work including Supply of Steel and its wastage Bend,Hooks and authorised over lapping shall be masured and Including cost of binding wire. DSR-5.22.6 18 S/f of mild steel gate/ grill of including all labour material T&P 19 12 mm thick plastering work in 1:4 cement sand mortor all complete work. DSR13.4.1 20 Providing and applying White cement based putty of average thickness 1 mm of approved brand and kajufacturer over the plastered wall surface to prepare the suurface even and smooth complete. DSR 13.80 (factor-0.728) 21 Distempring with oil bound distemper of approved brand and manfucture and of requried shade including cost of all materials labours T&P etc. DSR-13.62.1 22 Wall Painting with plastic emulsion paint of approved brand and manufacture on decortive wall surface S.I. No, 15.15+15.16 23 Painting or varnishing on iron work in small areas or new wood work with one coat of ready mix primer. DSR13.67.2 24 Providing and fixing 1 mm thick M.S. sheet sliding shutters with frame and diagonal braces of 40*40*6 mm angle iron, 3mm M.S. gusset platest the juvctions and corners 25 mm dia pulley 40*40*6 mm angle and T iron guide t the top and bottom respectively, incliding applying a priming coat of approved steel primer. DSR-10.4 25 Wiring for light point/ fan polnt/ exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group A. DSR 2022- 1.10.1 26 Wiring for Ilght/ power plug with 2X4 sq. mm FRLS PVC insulated copper 2 3 5 6 7 conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. DSR 2022- 1.12 27 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required. 2 X 10 sq. mm + 1 X6 sq. mm earth wire DSR 2022-1.14.5 28 Supplying and fixing suitable size GI box with modular plate and Cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular |switch. connections etc. as required. DSR 2022-1.31 29 Installatlon, testing and commlssloning of celllng fan, including Add as per Dist. Cost index wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. DSR 2022-1.44 30 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC |fuses including drilling holes in cubicle panel, making Connections, etc. as required 32 A TP&N DSR 2022- 2.1.1 31 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required Single pole and neutral DSR 20222.10.2 32 Supplying, installing, testing and commissioning of following capacity TPN distribution tap off box made of 1.6mm thick sheet steel enclosureduly painted with powder coating on existing rising mains complete with HRC fuses, interconnections, earthing etc. as required. 16 A TPN, 2 way DSR 2022. 3.3.1 33 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. DSR 2022- 5.2 34 Providing and fixing 25 mm X5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with Gl. nut, bolt, spring, washer excavation and re-filling etc. as required. DSR 2022- 5.1 35 Supply & fixing of fire extinguishers, ABC type 9.00 Kg capacity (ISImarked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of allmaterials and labour for proper completion of work. ELEC.-2018 - 1131(B)