Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Item No 1.01 :- Providing and laying cast in situ/Ready Mix Cement Concrete M-30 for bored piles each of load capacity and as per design and of 600mm diameter or as directed placed through steel shells sunk to the required depth through all strata except rock excluding provision of reinforcement as per detailed drawings and design approved by the Engineer-in-charge including placing with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) by tremie arrangements, compaction of concrete including chipping and dressing and withdrawal of shell etc. complete.(Excluding steel reinforcement) (Item No. 22.29) |
| 2 | Item No 1.02 :- Providing and laying Cast in situ/Ready Mixcement concrete M-35 of trap/granite/quartzite/gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.56) |
| 3 | Item No 1.03 :- Providing dry/trap/granite/quartzite/gneiss rubble stone soling 15cm to 20cm thick including hand packing and compacting etc. complete. (Item No. 21.38) |
| 4 | Item No 1.04 :- Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/granite/quartzite/gneiss metal for foundation and bedding/steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.(Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 24.04) |
| 5 | Item No 1.05 :- Providing preconstructional antitermite treatment as per I.S. 6313(Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. (Item No. 21.22) |
| 6 | Item No 1.06 :- Providing preconstructional antitermite treatment as per I.S. 6313(Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. (Item No. 21.24) |
| 7 | Item No 1.07 :- Providing preconstructional antitermite treatment as per I.S. 6313(Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30-60cm deep at 15cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper. (Item No. 21.25) |
| 8 | Item No 1.08 :- Empty boring for 325 to 400mm dia bored R.C.C. cast in situ piles including withdrawal of shell, removal of earth to a distance of 50 metres etc. complete. Spec :(As directed by Engineer in Charge) (Item No. 22.50) |
| 9 | Item No 1.09 :- Empty boring for 525 to 600mm dia. bored R.C.C. cast in situ piles including withdrawal of shell, removal of earth to a distance of 50 metres etc. complete. Spec :(As directed by Engineer in Charge) (Item No. 22.52) |
| 10 | Item No 1.10 :- Chiseling through pile shells in hard strata like boulders, soft and hard rocks Beyond 550mm and upto and inclusive of 750mm dia. including removing and stacking the loose materials etc. complete and disposing of the unserviceable materials outside complete. (Item No. 22.40) |
| 11 | Item No 1.11 :- Chiseling through pile shells in hard strata like boulders, soft and hard rocks Upto and inclusive of 550mm diameter including removing and stacking the loose materials etc. complete and disposing of the unserviceable materials outside complete. (Item No. 22.39) |
| 12 | Item No 1.12 :- Providing placing and Driving in position 6 millimeter mild steel liner for R.C.C. Piles upto required depth with 12mm thick mild steel cutting edge of 0.50m length at bottom including fabricating cutting the mild steel sheet to required diameter and shape, welding the joints and driving with the help of required machineries including all materials labours and lifts etc. complete as directed by the Engineer in charge. Upto 3.00 meter deep liner (Item No. 22.57) |
| 13 | Item No 1.13 :- Providing placing and Driving in position 6 millimeter mild steel liner for R.C.C. Piles upto required depth with 12mm thick mild steel cutting edge of 0.50m length at bottom including fabricating cutting the mild steel sheet to required diameter and shape, welding the joints and driving with the help of required machineries including all materials labours and lifts etc. complete as directed by the Engineer in charge. Spec :(As directed by Engineer in Charge From 3.00 to 9.50 meter deep liner (Item No. 22.58) |
| 14 | Item No 1.14 :- Carrying out load test for 1.5 times the proposed safe working load on the pile in driven position upto 400mm diameter including construction of test cap, use of accessories and instruments including providing graphs as per I.S. code or Std.Specifications and dismantling the test cap after testing and cleaning the site complete. (Item No. 22.43) |
| 15 | Item No 1.15 :- Carrying out load test for 1.5 times the proposed safe working load on the pile in driven position above 550mm and upto 650mm diameter including construction of test cap, use of accessories and instruments including providing graphs as per I.S. code or Std.Specifications and dismantling the test cap after testing and cleaning the site complete. (Item No. 22.45) |
| 16 | Item No 1.16 :- Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15cm to 20cm including watering and compaction etc. complete. (Item No. 21.37) |
| 17 | Item No 1.17 :- Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/granite/quartzite/gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.54) |
| 18 | Item No 1.18 :- ... (Item No. 25.54, First Floor) |
| 19 | Item No 1.19 :- ... (Item No. 25.54, Second Floor) |
| 20 | Item No 1.20 :- ... (Item No. 25.54, Third Floor) |
| 21 | Item No 1.21 :- ... (Item No. 25.54, Fourth Floor) |
| 22 | Item No 1.22 :- Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/granite/quartzite/gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.35) |
| 23 | Item No 1.23 :- ... (Item No. 25.35, First Floor) |
| 24 | Item No 1.24 :- ... (Item No. 25.35, Second Floor) |
| 25 | Item No 1.25 :- ... (Item No. 25.35, Third Floor) |
| 26 | Item No 1.26 :- ... (Item No. 25.35, Fourth Floor) |
| 27 | Item No 1.27 :- ... (Item No. 25.35, Fifth Floor) |
| 28 | Item No 1.28 :- Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/granite/quartzite/gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.74) |
| 29 | Item No 1.29 :- ... (Item No. 25.74, First Floor) |
| 30 | Item No 1.30 :- ... (Item No. 25.74, Second Floor) |
| 31 | Item No 1.31 :- ... (Item No. 25.74, Third Floor) |
| 32 | Item No 1.32 :- ... (Item No. 25.74, Fourth Floor) |
| 33 | Item No 1.33 :- Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/granite/quartzite/gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 26.07) |
| 34 | Item No 1.34 :- ... (Item No. 26.07, First Floor) |
| 35 | Item No 1.35 :- ... (Item No. 26.07, Second Floor) |
| 36 | Item No 1.36 :- ... (Item No. 26.07, Third Floor) |
| 37 | Item No 1.37 :- ... (Item No. 26.07, Fourth Floor) |
| 38 | Item No 1.38 :- Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/quartzite/granite/gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete.(Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 26.26) |
| 39 | Item No 1.39 :- ... (Item No. 26.26, First Floor) |
| 40 | Item No 1.40 :- ... (Item No. 26.26, Second Floor) |
| 41 | Item No 1.41 :- ... (Item No. 26.26, Third Floor) |
| 42 | Item No 1.42 :- ... (Item No. 26.26, Fourth Floor) |
| 43 | Item No 1.43 :- Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/granite/quartzite/gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 26.19) |
| 44 | Item No 1.44 :- ... (Item No. 26.19, First Floor) |
| 45 | Item No 1.45 :- ... (Item No. 26.19, Second Floor) |
| 46 | Item No 1.46 :- ... (Item No. 26.19, Third Floor) |
| 47 | Item No 1.47 :- ... (Item No. 26.19, Fourth Floor) |
| 48 | Item No 1.48 :- Providing and fixing in position TMT-FE-500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (Item No. 26.33) |
| 49 | Item No 1.49 :- ... (Item No. 26.33, First Floor) |
| 50 | Item No 1.50 :- ... (Item No. 26.33, Second Floor) |
| 51 | Item No 1.51 :- ... (Item No. 26.33, Third Floor) |
| 52 | Item No 1.52 :- ... (Item No. 26.33, Fourth Floor) |
| 53 | Item No 1.53 :- Waterproofing Treatment to new Toilet/bathroom by using Polymeric Cementitious Membrane as approved by Engineer in charge, followed by 112mm thick brick bat coba covered with 20mm mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents. If there are lots of honeycombs and identified bad patches of concrete the same should be grouted as per the instructions of site incharge.(The grouting shall be paid separately). Clean the entire surface thoroughly and over this prepared surface, apply three coats of polymeric Cementitious waterproofing coating having a non-toxic, 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate(MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Provide and lay 112mm average thicknes of brick bat coba in cement mortar 1:5 over 12mm thickCM 1:3 bedding with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50 Kg bag of cement and finishing with 20mm thick cement plaster in cement mortar 1:3 by mixing one 330 grams pouch of above admixture per 50 Kg bag of cement, including all lead, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of wall and work up to a height of 300mm or as directed and including finishing the top layer of waterproofing treatement with false marking of 30cm x 30cm or as directed, curing and covering the whole treatment. MPBP Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties:1) Elongation %(ASTM D412-2016): @ 100% 2) Tensile Strength N/mm2(ASTM D412-2016): 3.3 3) Specific Gravity: 1.02 ± 0.02 4) Total Solids(ASTM D1644-2012): 43.98 5) Hardness Shore A(ASTM D2240-2015): 82 (Item No. 52.13) |
| 54 | Item No 1.54 :- ... (Item No. 52.13, First Floor) |
| 55 | Item No 1.55 :- ... (Item No. 52.13, Second Floor) |
| 56 | Item No 1.56 :- ... (Item No. 52.13, Third Floor) |
| 57 | Item No 1.57 :- ... (Item No. 52.13, Fourth Floor) |
| 58 | Item No 1.58 :- Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete (Item No. 27.05) |
| 59 | Item No 1.59 :- ... (Item No. 27.05, First Floor) |
| 60 | Item No 1.60 :- ... (Item No. 27.05, Second Floor) |
| 61 | Item No 1.61 :- ... (Item No. 27.05, Third Floor) |
| 62 | Item No 1.62 :- ... (Item No. 27.05, Fourth Floor) |
| 63 | Item No 1.63 :- ... (Item No. 27.05, Fifth Floor) |
| 64 | Item No 1.64 :- Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (Item No. 32.04) |
| 65 | Item No 1.65 :- ... (Item No. 32.04, First Floor) |
| 66 | Item No 1.66 :- ... (Item No. 32.04, Second Floor) |
| 67 | Item No 1.67 :- ... (Item No. 32.04, Third Floor) |
| 68 | Item No 1.68 :- ... (Item No. 32.04, Fourth Floor) |
| 69 | Item No 1.69 :- Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. (Item No. 32.15) |
| 70 | Item No 1.70 :- ... (Item No. 32.15, First Floor) |
| 71 | Item No 1.71 :- ... (Item No. 32.15, Second Floor) |
| 72 | Item No 1.72 :- ... (Item No. 32.15, Third Floor) |
| 73 | Item No 1.73 :- ... (Item No. 32.15, Fourth Floor) |
| 74 | Item No 1.74 :- Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete. (Item No. 32.32) |
| 75 | Item No 1.75 :- ... (Item No. 32.32, First Floor) |
| 76 | Item No 1.76 :- ... (Item No. 32.32, Second Floor) |
| 77 | Item No 1.77 :- ... (Item No. 32.32, Third Floor) |
| 78 | Item No 1.78 :- ... (Item No. 32.32, Fourth Floor) |
| 79 | Item No 1.79 :- ... (Item No. 32.32, Fifth Floor) |
| 80 | Item No 1.80 :- Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity.(With prior approval of S.E.) (Item No. 36.20) |
| 81 | Item No 1.81 :- ... (Item No. 36.20, First Floor) |
| 82 | Item No 1.82 :- ... (Item No. 36.20, Second Floor) |
| 83 | Item No 1.83 :- ... (Item No. 36.20, Third Floor) |
| 84 | Item No 1.84 :- ... (Item No. 36.20, Fourth Floor) |
| 85 | Item No 1.85 :- Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete. (Item No. 35.24) |
| 86 | Item No 1.86 :- ... (Item No. 35.24, First Floor) |
| 87 | Item No 1.87 :- ... (Item No. 35.24, Second Floor) |
| 88 | Item No 1.88 :- ... (Item No. 35.24, Third Floor) |
| 89 | Item No 1.89 :- ... (Item No. 35.24, Fourth Floor) |
| 90 | Item No 1.90 :- ... (Item No. 35.24, Fifth Floor) |
| 91 | Item No 1.91 :- Providing waterproof plaster in W.C. and bath 20mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing(and filling joints of Nahani trap and any outlet by properly) etc. complete. (Item No. 31.07) |
| 92 | Item No 1.92 :- ... (Item No. 31.07, First Floor) |
| 93 | Item No 1.93 :- ... (Item No. 31.07, Second Floor) |
| 94 | Item No 1.94 :- ... (Item No. 31.07, Third Floor) |
| 95 | Item No 1.95 :- ... (Item No. 31.07, Fourth Floor) |
| 96 | Item No 1.96 :- Providing water proof bedding for flooring of Bath and WC 25mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/-including ponding test etc. complete. (Item No. 31.05) |
| 97 | Item No 1.97 :- ... (Item No. 31.05, First Floor) |
| 98 | Item No 1.98 :- ... (Item No. 31.05, Second Floor) |
| 99 | Item No 1.99 :- ... (Item No. 31.05, Third Floor) |
| 100 | Item No 1.100 :- ... (Item No. 31.05, Fourth Floor) |
| 101 | Item No 1.101 :- Providing and laying in position flooring of telephone black/Amba White/Cat bary brown/Ruby red/Ocean Brown granite stone of approved shade and size 18mm to 20mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. (Item No. 33.34, First Floor) |
| 102 | Item No 1.102 :- ... (Item No. 33.34, Second Floor) |
| 103 | Item No 1.103 :- ... (Item No. 33.34, Third Floor) |
| 104 | Item No 1.104 :- ... (Item No. 33.34, Fourth Floor) |
| 105 | Item No 1.105 :- Providing and laying telephone black/Amba White/Cadburybrown/Ruby red/Ocean Brown granite stone of 18 to 20mm thick for door frame/dado/window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. (Item No. 33.68) |
| 106 | Item No 1.106 :- ... (Item No. 33.68, First Floor) |
| 107 | Item No 1.107 :- ... (Item No. 33.68, Second Floor) |
| 108 | Item No 1.108 :- ... (Item No. 33.68, Third Floor) |
| 109 | Item No 1.109 :- ... (Item No. 33.68, Fourth Floor) |
| 110 | Item No 1.110 :- Providing and laying vitrified mirror/glossy finish tiles decorative type having size 590mm to 605mm x 590mm to 605mm of 8 to 10mm thickness and confirming to IS. 15622-2006(group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. (Item No. 33.40) |
| 111 | Item No 1.111 :- ... (Item No. 33.40, First Floor) |
| 112 | Item No 1.112 :- ... (Item No. 33.40, Second Floor) |
| 113 | Item No 1.113 :- ... (Item No. 33.40, Third Floor) |
| 114 | Item No 1.114 :- ... (Item No. 33.40, Fourth Floor) |
| 115 | Item No 1.115 :- Providing and laying vitrified mirror/glossy finish tiles having size 590mm to 605mm x 590mm to 605mm of 8 to 10mm thickness and confirming to IS. 15622-2006(group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete (Item No. 33.41) |
| 116 | Item No 1.116 :- ... (Item No. 33.41, First Floor) |
| 117 | Item No 1.117 :- ... (Item No. 33.41, Second Floor) |
| 118 | Item No 1.118 :- ... (Item No. 33.41, Third Floor) |
| 119 | Item No 1.119 :- ... (Item No. 33.41, Fourth Floor) |
| 120 | Item No 1.120 :- Providing and fixing machine cut machine polished 18mm to 20mm thick telephone black/Amba White/Cat bary brown/RBI red/Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. (Item No. 33.35) |
| 121 | Item No 1.121 :- ... (Item No. 33.35, First Floor) |
| 122 | Item No 1.122 :- ... (Item No. 33.35, Second Floor) |
| 123 | Item No 1.123 :- ... (Item No. 33.35, Third Floor) |
| 124 | Item No 1.124 :- ... (Item No. 33.35, Fourth Floor) |
| 125 | Item No 1.125 :- ... (Item No. 33.35, Fifth Floor) |
| 126 | Item No 1.126 :- Providing and constructing granite kitchen platform with fixing of stainless steel sink 600mm x 450mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30mm thick supports with kadappah top 35 to 40mm thick and polished granite 16 to 20mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15cm height and top granite of 75 x 40cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete.(Platform top size 5.00m x 0.60m and height is 0.75 m) (Item No. 41.78, First Floor) |
| 127 | Item No 1.127 :- Providing and laying Antiskid Ceramic tiles of approved quality of size 30cm x 30cm and confirming to IS 15622-2006(Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. (Item No. 33.67) |
| 128 | Item No 1.128 :- ... (Item No. 33.67, First Floor) |
| 129 | Item No 1.129 :- ... (Item No. 33.67, Second Floor) |
| 130 | Item No 1.130 :- ... (Item No. 33.67, Third Floor) |
| 131 | Item No 1.131 :- ... (Item No. 33.67, Fourth Floor) |
| 132 | Item No 1.132 :- Providing and laying ceramic tiles having size 30cm. x 60cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/colour cement slurry cleaning curing etc. complete. (Item No. 33.27, First Floor) |
| 133 | Item No 1.133 :- Providing and fixing machine cut mirror polished 18mm to 20mm thick telephone black granite/Amba White/Cat bary brown/RBI red/Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish (Item No. 33.36) |
| 134 | Item No 1.134 :- ... (Item No. 33.36, First Floor) |
| 135 | Item No 1.135 :- ... (Item No. 33.36, Second Floor) |
| 136 | Item No 1.136 :- ... (Item No. 33.36, Third Floor) |
| 137 | Item No 1.137 :- ... (Item No. 33.36, Fourth Floor) |
| 138 | Item No 1.138 :- Providing and fixing solid core flush door shutter in single leaf 32mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. (Item No. 39.09) |
| 139 | Item No 1.139 :- Providing and fixing solid core flush door shutter commercial in single leaf 32mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete. (Item No. 39.10) |
| 140 | Item No 1.140 :- Providing and fixing Country cut teak wood double or single leaf second class fully panelled door shutter with 35mm thick style and rail with 25mm thick panels with openable fan light as per detailed drawings. Excluding the door frame 60mm x 100mm stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats.(Excluding the door frame) (Item No. 39.04) |
| 141 | Item No 1.141 :- Providing and fixing fiber glass reinforced polyster door shutter 30mm thick as per IS 14856(2000)(Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete (Item No. 39.58) |
| 142 | Item No 1.142 :- Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec.number: As directed by Engineer-in-charge. (Item No. 23.09) |
| 143 | Item No 1.143 :- Providing and fixing in position powder coated aluminium louvered windows/ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38mm x 1.22mm box type, 5mm thick sheet glass louvers, of approved quality etc. complete. (Item No. 39.68) |
| 144 | Item No 1.144 :- Providing and fixing in position(as per 1868/1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90mm at weight 0.637 Kilogram/running metre. with window frame bottom track section 92 x 31.75 x 1.30mm at weight 1.070 Kilogram/running metre.. Top and side track section 92 x 31.75 x 1.30mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25mm at weight 0.417 Kilogram/running metre. Inter locking section 40 x 18 x 1.10mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating without box (Item No. 39.44) |
| 145 | Item No 1.145 :- Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/square metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. (Item No. 40.02) |
| 146 | Item No 1.146 :- Providing and Fixing mat finish stainless steel(of 302 grade) railing with top pipe of 50mm dia. and vertical pipe of 38mm dia at 0.60m c/c or as required and horizontal pipes of 25mm dia in three rows, all pipes of 2mm thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75mm dia above newel post of 75mm diameter etc. complete(Prior approval of sample and brand by Ex.Engineer is necessary before use) (Item No. 40.08, First Floor) |
| 147 | Item No 1.147 :- Providing and laying in trenches 50mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (Item No. 42.66) |
| 148 | Item No 1.148 :- Providing and fixing on walls/ceiling/floor 15mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (Item No. 42.55) |
| 149 | Item No 1.149 :- Providing and fixing on walls/ceiling/floor 20mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (Item No. 42.56) |
| 150 | Item No 1.150 :- Providing and fixing on walls/ceiling/floor 32mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (Item No. 42.58) |
| 151 | Item No 1.151 :- Providing, laying and fixing, jointing Eco-drain 110mm SN 8 Nu-Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete. (Item No. 43.30) |
| 152 | Item No 1.152 :- Providing, laying and fixing, jointing Eco-drain 160mm SN 4 Nu-Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. (Item No. 43.31) |
| 153 | Item No 1.153 :- Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (Item No. 42.87) |
| 154 | Item No 1.154 :- Providing and fixing 100mm dia stabiliser pipe/P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. (Item No. 42.52) |
| 155 | Item No 1.155 :- Providing and fixing 15mm dia. screw down bib/stop tap of brass including necessary socket union nut complete. (Item No. 41.40) |
| 156 | Item No 1.156 :- Providing and fixing screw down for 20mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. (Item No. 41.44) |
| 157 | Item No 1.157 :- Providing and fixing screw down for 50mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. (Item No. 41.48) |
| 158 | Item No 1.158 :- Providing and fixing orissa type colour glazed earthenware 625 x 450mm. w.c. pan including trap, C.I. soil and vent pipe upto the out side face of wall including 100mm. dia. C.I. plug, bend, 15mm. thick 10 litre PVC flushing cistern with all necessary pipe connection etc. complete. (Item No. 42.35) |
| 159 | Item No 1.159 :- Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall, 100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. (Item No. 42.86) |
| 160 | Item No 1.160 :- Providing and fixing 100mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete. (Item No. 41.51) |
| 161 | Item No 1.161 :- Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. (Item No. 41.63) |
| 162 | Item No 1.162 :- Providing and fixing 15cm rigid PVC Nahani trap including PVC grating, bend, connectingpiece of UPVC pipe up to the outside face of wall, making the good damaged surface and testing etc. complete(Prior approval of sample and brand by Ex. Engr. is necessary before use) (Item No. 43.18) |
| 163 | Item No 1.163 :- Providing, constructing and fixing 450mm dia. Inspection chamber made up of Polypropylene/polyethylene material of thickness 3.5mm and height of 388mm with 160 or 200mm main inlet(s) outlet and 110 and/or 160mm branch inlets, with 450mm dia. Ultra shaft pipe of HDPE material having height of 460mm, having R.C.C. cover and frame fixing in 150mm thick in c.c.1:2:4, having crushed sand bed of 150mm thick of size 750mm dia. Including excavation and refilling the sides of chamber by sand crushed cushioning 150mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete. (Item No. 43.28) |
| 164 | Item No 1.164 :- Providing, constructing and fixing 600mm dia. Inspection chamber made up of Polypropylene/polyethylene material Having 315mm diameter inlet(s)/outlets and with eccentric reducers as per requirement to connect 160mm and 200mm pipes having thickness of 5mm and 600mm in height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5mm having R.C.C. cover and frame fixing in 150mm thick in c.c.1:2:4, having crushed sand bed of 150mm thick of size 750mm dia. Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150mm thickness, connecting all required UPVC fittings with rubber lubricant etc.complete. (Item No. 43.29) |
| 165 | Item No 1.165 :- Providing, constructing and fixing 250mm dia. Inspection chamber made up of UPVC material of thickness 3.5mm and height of 259mm with inlet and outlet of 110mm dia. with 75mm dia. U Trap, Ultra shaft pipe of Upvc material having height of 470mm and fixing Ultra 250mm dia. UPVC cover and frame in 150mm thick in c.c.1:2:4, having crushed sand bed of 100mm thick of size 550mm dia. Including excavation and refilling the sides of chamber by crushed sand cushioning 150mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete. (Item No. 43.27) |
| 166 | Item No 1.166 :- Providing and fixing chromium plated towel rod 16mm dia and 75cm. in length including all accessories complete. (Item No. 42.31) |
| 167 | Item No 1.167 :- Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. (Item No. 42.20) |
| 168 | Item No 1.168 :- Providing and fixing 45cm wide mild steel ladder of 40mm x 6mm mild steel flat stringers and steps of 18mm dia. mild steel bar for water tank including fixing it in(1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete.(Anti Corossive Paint) (Item No. 41.56) |
| 169 | Item No 1.169 :- Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.(Wooden centering will not be allowed.) With fine aggregate(Crushed sand VSI Grade) (Item No. 24.16) |
| 170 | Item No 1.170 :- Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate(natural sand/VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25mm, , cement content not to be less than 150kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor/by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. (Item No. 5.13) |
| 171 | Item No 1.171 :- Providing and laying in situ cement concrete M-30 with tremix treatment for 200mm thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen(excluding reinforcement) with coarse and fine aggregate(natural sand/VSI grade finely washed crushed sand) etc. complete with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. (Item No. 5.22a) |
| 172 | Item No 1.172 :- Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete.(Lift upto 1.5m.) By Mechanical Means (Item No. 21.02) |
| 173 | Item No 1.173 :- Providing and laying in situ/ready mix M-25 controlled reinforced cement concrete of trap metal for raft slab including \"V\" haunches, formwork, scaffolding, compaction by vibrating, finishing curing etc. complete. concrete batch mix plant/pan mixer with fine agreegates of required specifications(VSI sand finely washed etc) etc. complete.(excluding reinforcement). a) RCC Grade with reversible drum type mixer/concrete batch mix plant(pan mixer) . (Item No. 17.33) |
| 174 | Item No 1.174 :- Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/granite/quartzite/gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 26.19) |
| 175 | Item No 1.175 :- Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/granite/quartzite/gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.72) |
| 176 | Item No 1.176 :- Providing and fixing in position TMT-FE-500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (Item No. 26.33) |
| 177 | Item No 1.177 :- Providing & Fixing in position, Acoustical Panelling made from Fabric wrapped Compressed polyester fibre nonwoven 9mm panels on, 50 x 50mm sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 gsm synthetic wool 50mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings/finishing-items/paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour, finishing etc complete (Item No. 51.01) |
| 178 | Item No 1.178 :- Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. (Item No. 41.60) |
| 179 | Item No 1.179 :- Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete.(Lift upto 1.5m.) By Mechanical Means (Item No. 21.02) |
| 180 | Item No 1.180 :- Providing dry/trap/granite/quartzite/gneiss rubble stone soling 15cm to 20cm thick including hand packing and compacting etc. complete. (Item No. 21.38) |
| 181 | Item No 1.181 :- Providing and laying in situ/ready mix/ready mix M10 cement concrete of trap/granite/quartzite/gneiss metal in foundation including necessary centering, formwork, bailing out water, compacting and curing etc. complete.(with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/concrete batch mix plant(pan mixer) with natural/artifical sand) (Item No. 12.25) |
| 182 | Item No 1.182 :- Providing and laying box type flexible gabions of required size and rope of 10mm Ø polypropylene material four strand mesh of 150mm x 150mm size, filled with hand packed stones of 20 to 50 kilogram in weight; so as to give total mass required with all leads and lifts including fusing top of gabions, tying to each other and laying to required line, level, slope as per drawing, section as directed etc. complete under tidal conditions. ::(a) Gabions of size – 1.00 x 1.00 x 1.00 M (Item No. 49.22a) |
| 183 | Item No 1.183 :- Back filling behind abutment, wing wall and return wall as per drawings and technical specifications etc. complete.(by granular material) (Item No. 12.70) |
| 184 | Item No 1.184 :- Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/bolted/welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. (Item No. 23.04) |
| 185 | Item No 1.185 :- Providing and fixing colour coated Zincalume(R) AZ150(min 150 gms/sq.mt. total on each side) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45mm Base Metal Thickness(BMT)(0.5mm TCT), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy(55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND(R) steel quality super durable polyester paint coat(with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050mm effective cover width and nominal 25-30mm deep ribs with subtle square fluting in the five pan at nominal 180-250mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete.(weight of profile 4.52 Kilogram/square metre) (Item No. 38.34) |
| 186 | Item No 1.186 :- Providing and fixing of colour coated Zincaluminium(R) AZ150(min 150 gms/sq.mt. total on each side) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45mm Base Metal Thickness(BMT)(0.5mm TCT), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated withAluminium-Zinc alloy(55% aluminiumm 43.4% zinc 1.6% silicon) with COLORBOND(R) steel quality super durable polyster paint coat(with inorganic pigment). The paint shall have a total coating thickness of nominal 35mm, comprising of nominal 25mmexterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050mm effective cover width and nominal 25-30mm deep ribs with sublet square fluting in the five pan at nominal 180-250mmcenter-to-center. The end rib shall be designed for anti-capacity groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete.(weight of profile 4.52 Kilogram/square metre) 600mm girth(Surface Width). (Item No. 38.35) |
| 187 | Item No 2.01 :- Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete.(Lift upto 1.5m.) By Mechanical Means (Item No. 21.02) |
| 188 | Item No 2.02 :- Providing soling using 80mm size trap metal in 15cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. (Item No. 21.40) |
| 189 | Item No 2.03 :- Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 24.01) |
| 190 | Item No 2.04 :- Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/granite/quartzite/gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.15) |
| 191 | Item No 2.05 :- Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/granite/quartzite/gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 26.19) |
| 192 | Item No 2.06 :- Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/granite/quartzite/gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.74) |
| 193 | Item No 2.07 :- Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/granite/quartzite/gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.33, Sixth Floor) |
| 194 | Item No 2.08 :- Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/granite/quartzite/gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.52, Sixth Floor) |
| 195 | Item No 2.09 :- Providing and fixing in position TMT-FE-500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (Item No. 26.33) |
| 196 | Item No 3.01 :- Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete.(Lift upto 1.5m.) By Mechanical Means (Item No. 21.02) |
| 197 | Item No 3.02 :- Providing dry/trap/granite/quartzite/gneiss rubble stone soling 15cm to 20cm thick including hand packing and compacting etc. complete. (Item No. 21.38) |
| 198 | Item No 3.03 :- Providing and laying in situ/ready mix/ready mix M10 cement concrete of trap/granite/quartzite/gneiss metal in foundation including necessary centering, formwork, bailing out water, compacting and curing etc. complete.(with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/concrete batch mix plant(pan mixer) with natural/artifical sand) (Item No. 12.25) |
| 199 | Item No 3.04 :- Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/granite/quartzite/gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork, cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided(Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.13) |
| 200 | Item No 3.05 :- Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/granite/quartzite/gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.33) |
| 201 | Item No 3.06 :- Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/granite/quartzite/gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.52) |
| 202 | Item No 3.07 :- Providing, cutting, bending, hooking, tying and laying in position TMT FE 500 steel bars for reinforcement for all RCC works as per detailed drawings etc. complete. (Item No. 14.01) |
| 203 | Item No 3.08 :- Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete (Item No. 27.05) |
| 204 | Item No 3.09 :- Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete. (Item No. 32.32) |
| 205 | Item No 3.10 :- Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete. (Item No. 35.24) |
| 206 | Item No 3.11 :- Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 50mm thick with 3mm diameter mild steel bar reinforcement, of approved design on both side, fixing in cement mortar 1:3 and curing etc. complete (Item No. 26.46) |
| 207 | Item No 3.12 :- Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. (Item No. 23.01) |
| 208 | Item No 4.01 :- Providing earth work in embankment with approved materials obtained from other sources upto lead of 50m. including all lifts, laying in layers of 20cm. to 30cm. thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97 % of standard proctor density etc. complete(Material obtained from Other sources) (Item No. 2.28) |
| 209 | Item No 4.02 :- Providing dry/trap/granite/quartzite/gneiss rubble stone soling 15cm to 20cm thick including hand packing and compacting etc. complete. (Item No. 21.38) |
| 210 | Item No 4.03 :- Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate(natural sand/VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25mm, , cement content not to be less than 150kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor/by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. (Item No. 5.13) |
| 211 | Item No 4.04 :- Providing and laying in situ cement concrete M-30 with tremix treatment for 200mm thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4mm wide and 20mm deep with necessary refilling with polysuphide sealent(Pouring grade) confirming to BS : 5212-1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter(excluding reinforcement) with coarsen and fine aggregate Using V.S.I.Quality Artifitial Sand etc. complete with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. (Item No. 5.22b) |
| 212 | Item No 4.05 :- Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/colour of 2.5mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/lux and Qd of 100 mcd/sqm/lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). (Item No. 6.12a) |
| 213 | Item No 4.06 :- Supplying and Fixing of Molded Shank Raised Pavement Markers/Cat\"s Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50mm, 100mm and 102 +/-2mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/-5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/-2mm and height not less than 30+/-2mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. (Item No. 6.09) |
| 214 | Item No 4.07 :- Providing and fixing road junction/information sign boards of size 1.80 x 0.90 Meter Prepared 16 guageM.S.sheet on frame of M.S.angle of size 35 x 35 x 5mm with cross bracing of size 35x35x5mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border/letters/numeral/arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection including two angle iron post of size 65 x 65 x 6mm of 3.65m. long inflated at bottom, drilled on top and painted in white and black bands of 30cm. with 4 Nos. high strength G.I. bolts and nuts of size 10mm dia. and 20mm long. Sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with cement concrete 1:4:8 block of 60cm x 60cm x 75cm size as directed by Engineer-in-charge etc. complete. Mild Steel Board with Engineering Grade. (Item No. 6.41) |
| 215 | Item No 4.08 :- Road Delineators: Supplying and installation of delineators(Roadway Indicators, Hazard markers, Object markers) 80 to 100cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings (Item No. 6.15) |
| 216 | Item No 4.09 :- Metal Beam Crash Barrier -- Type-A, W : Metal Beam Crash Barrier(Providing and erecting a W metal beam crash barrier comprising of 3mm thick corrugated sheet metal beam rail, 70cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5mm spaced 2m centre to centre, 1.8m high, 1.1m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5mm, 330mm long complete as per clause 810)\" (Item No. 7.30) |
| 217 | Item No 4.10 :- Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete.(Lift upto 1.5m.) By Mechanical Means (Item No. 21.02) |
| 218 | Item No 4.11 :- Providing dry/trap/granite/quartzite/gneiss rubble stone soling 15cm to 20cm thick including hand packing and compacting etc. complete. (Item No. 21.38) |
| 219 | Item No 4.12 :- Providing and laying in situ/ready mix/ready mix M10 cement concrete of trap/granite/quartzite/gneiss metal in foundation including necessary centering, formwork, bailing out water, compacting and curing etc. complete.(with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/concrete batch mix plant(pan mixer) with natural/artifical sand) (Item No. 12.25) |
| 220 | Item No 4.13 :- Providing and laying in situ/ready mix M-20 controlled reinforced cement concrete of trap metal for raft slab including \"V\" haunches, formwork, scaffolding, compaction by vibrating, finishing curing etc. complete. concrete batch mix plant/pan mixer with fine agreegates of required specifications(VSI sand finely washed etc) etc. complete.(excluding reinforcement). a) RCC Grade with reversible drum type mixer/concrete batch mix plant(pan mixer) . (Item No. 17.32) |
| 221 | Item No 4.14 :- Providing cast in situ/ready mix M20 grade cement concrete for head walls of CD work/retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete.(with reversible drum type mixer/concrete batch mix plant(pan mixer) with SCADA (Item No. 11.29) |
| 222 | Item No 4.15 :- Providing and laying in situ/ready mix M-25 controlled cement concrete of trap/granite/quartzite/gneiss metal for RCC work in solid/deck slab etc. including ramming, vibrating, curing, formwork, centering and finishing in cement plaster excluding reinforcement etc. complete.(with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant/pan mixer and fine agreegates of required specifications(VSI sand finely washed etc) i) Height up to 5 m, normal rate. ii) Height 5 to 7.50 m, add 5 percent extra over basic rate. iii) Height 7.50 to 10 m, 7.50 percent extra. iv) Over 10m Height, add 10 percent extra for every 2.50m rise. (Item No. 14.15) |
| 223 | Item No 4.16 :- Providing, cutting, bending, hooking, tying and laying in position TMT FE 500 steel bars for reinforcement for all RCC works as per detailed drawings etc. complete. (Item No. 14.01) |
| 224 | Electrical Sub Estimate 1 - Providing Internal Electrification toProposed Court Building (Stilt + Ground Floor + 4 Floors) ( 5 Court Halls)at Mahad, Tal. Mahad, Dist Raigad.Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 225 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 226 | Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 227 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 228 | Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 229 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 230 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 231 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 232 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 233 | Supplying and erecting modular type switch one way 16 / 20 A, duly erected on provided plate and box with wiring connections complete with neon indicator. |
| 234 | Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected. |
| 235 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete |
| 236 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 237 | Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 238 | Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 239 | Supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 240 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 241 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 242 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 243 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 244 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 245 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No:WGPW/CW |
| 246 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No:WGPW/CW |
| 247 | Point wiring for independent plug, concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No WG-PW/SW |
| 248 | Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW |
| 249 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW |
| 250 | Supplying and erecting LED square / circular Max. 18 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 251 | Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W. |
| 252 | Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 253 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 254 | Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 255 | Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size. |
| 256 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 257 | Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF |
| 258 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF |
| 259 | Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. |
| 260 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 261 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC |
| 262 | Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system. |
| 263 | Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of one hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS |
| 264 | Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete |
| 265 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 266 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 267 | Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 268 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 269 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 270 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 271 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 272 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 273 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 274 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 275 | Providing & erecting 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 276 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core25 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 277 | Supplying, erecting& terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10 sq. mm. copperconductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 278 | Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core4sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 279 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 280 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware. |
| 281 | Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbonbased environment friendly back fill Ground Enhancing compoundcomplete with all materials, testing & recording the resultsas per specification no ESE -LA |
| 282 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessarycopperclampsfixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. |
| 283 | Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. |
| 284 | Supplying and erecting static energy meter with 240V 50 Hz. AC supply 5 to 30 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and displaykWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA) with transparent hinge type box completeerectedonpolished teak woodboardduly wiredwithrequiredsizeof weather proofPVC wires duly testedby electric supply company. |
| 285 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 286 | Supplying & erecting 10 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 287 | Supplying & erecting 100 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 288 | Supplying, erecting & commissioning MDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 289 | Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 290 | Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 3 x 8 extensions complete. |
| 291 | Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete |
| 292 | Supplying, installing, testing & commissioning IP telephone instrument as per specification complete. |
| 293 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 294 | Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC |
| 295 | Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 296 | Supplying, fixing, and configuring 20 Ports+4G Combo, Managed Layer 2, POE Switch erected in provided rack complete. |
| 297 | Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WGNWC/ GBS |
| 298 | Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack or as directed as per specification No. WG-NWC/ADSL |
| 299 | Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. |
| 300 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 301 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK |
| 302 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK |
| 303 | Supplying and fixing 17U floor mount rack (Dimension-DxWxH – 800x600x954 mm) as per specification No. WG-NAS/RAK |
| 304 | Supplying and fixing dual-band manageable wireless 3x3 Mesh Router, high performance, 802.11 n/ac unified, concurrent access point with POE in networking as per specification no. WG-NAS/LAP2 |
| 305 | Providing Supplying, & fixing of EPSON make 3LCD Projector with 3300 Imns , HDMIUSB . VGA Ports . Bright high-quality images with easy to use XGA model featuring 3LCD technology Resolution 1024x768, Contrast Ratio 15000: 1 Throw Ratio 1.44- 1.95:1 VideoColor, modes: Blackboard, Cinema, Dynamic. Presentation, sRGB 2 Watt inbuilt loudspeaker, Weight 2.4kg. Colour reproduction upto 1.07 billion colours Aspect ratio 4:3 (Rates are as per Sanct.letter No:-1685/ 2022 /Dated:-29.06.2022 )(Rate sanctioned By SE Pune for Proposed 100 Beded MCH Wing at GMC Miraj, Civil Hospital, Sangli estimate) |
| 306 | Providing supplying. & fixting of Motorized 4 x 6 mat finish screen with 2 \"black border ,Seamless compund milti-layers diffuse reflection fabric . Tabular Motor with smooth & quiter operation (Rates are as per Sanct.letter No:-1685/ 2022 /Dated :- 29.06.2022 )(Rate sanctioned By SE Pune for Proposed 100 Beded MCH Wing at GMC Miraj, Civil Hospital, Sangli estimate) |
| 307 | Proving Supplying & Fixing of celling mount kit Heavy Quality, adjustable with -/+ 15\" Tilting. 2 feet x 2 feet to fit EPSON make 3LCD Projector with adjustable Bracket(Rates are as per Sanct.letter No:-1685/ 2022/ Dated : - 29.06.2022 ) (Rate sanctioned By SE Pune for Proposed 100 Beded MCH Wing at GMC Miraj, Civil Hospital, Sangli estimate) |
| 308 | Sub Work No-2 Providing External Services allied with SubstationWorks toProposed Court Building (Stilt + Ground Floor + 4 Floors) ( 5 Court Halls)at Mahad, Tal. Mahad, Dist Raigad. Supplying, installation, testing and commissioning extendable/non-extendable outdoor type 22 kV 630A, load break isolator switch, compliant to IEC 62271 -100, 200 and 102, on provided MS channels/trench/foundation as per specification no SW-HTS / LBS |
| 309 | Supplying, installing, testing and commissioning SF 6 Insulated22kV, 630A, 16kA/3sec, 2 way outdoor, extensible motorised SCADA compatible RMU, internal arc testedas per electric supply company specification consisting of 1 no. feeder with 1 LBS and 1 no. feeder with 1 VCBcompliant to IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA |
| 310 | Supplying,erecting,testing and commissioning 22KV HT metering cubical (compact type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paintof required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no. of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 25/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 22000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, andprovision for incoming and outgoing cables complete duly tested by licensee with necessary test certificatesand erected on provided plinth/ cc foundation. |
| 311 | Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. 1)(50X50X5mm= Wt /Mtr3.8= Total Length28= Mtr, Total Wt=(3.8*28Mt=106.4Kg) 2)(25X25X5mm= Wt /Mtr1.8= Total Length=17 Mtr, Total Wt= 1.8*17 Mtr= 30.6Kg)Total wt=137Kg (For Shed) |
| 312 | Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns withgalvanization process compliance to IS 2629:1985 tobeused for fabricationofboxespanelboardsetc. including cutting, bending, drilling, welding, riveting etc. and paintingwithone coat of red leadpaint and 2 coats of enamel paint. (8*3=24Sq.Mtr) (For Shed) |
| 313 | Supplying and erecting 100 kVAr, 3 phase, 50 Hz., Power contactors Derated for microprocessor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC |
| 314 | Supplying , erecting & terminating XLPE insulated galvanised steel formed wire armoured (strip) cable, 22 kV(E), 3 x 120 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 315 | Providing and erecting Heat shrinkable indoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 316 | Providing and erecting Heat shrinkable outdoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 317 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 318 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 319 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 320 | Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 321 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP |
| 322 | Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 323 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. |
| 324 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 325 | Supplying, installing, testing & commissioning 3 phase, 22/0.433 kV, 50 Hz., 315 kVA,Mineral oil immersed and naturally cooled outdoor type, Copper woundNon-sealed transformerdelta/star connected with additional neutral brought out on load side, temperature rise shouldnot exceed 45℃ by thermometer in oil and 50℃ by the resistance methodin winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off Load +5 to -10 in steps of 2.5%,having 7 number of tap positions with standard accessories complete with test certificate with losses below 1076 Watts at 50% load, 3255 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL |
| 326 | Supplying and fixingPVC synthetic elastomerelectrically insulating matwith class C insulation conforming to IS: 15652 – 2006 tested having 3mm thickness up to 33 kV |
| 327 | Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. |
| 328 | SITC of Main Panel,The panel shall be comprising of following & IEC 61439, Panel should be fully compartmentallised, wall mounted withM.S. Channel dully painted, fabricated of 14/16swg CRCA sheets completely derusted, chemically treated and powder coated with approved shade, ON - Off Indicating LED lamp, locking arrangements, withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage, current, frequency, power factor , ON hrs, kWh, EB and DG set metering and LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden as per SLD having following items:- MainI/O 630 Amp FP MCCB. DGI/O 630 Amp FP MCCB. Bus bar chamber TPN & E with aluminium bars 630A Outgoing-630A FP MCCB- 2 N0s.200A FP MCCB - 7 Nos.100A FP MCCB - 3 Nos. 63A FP MCB C series - 4Nos. 32A FP MCB C series - 2 Nos. (RA Sheet Attached) |
| 329 | Supplying, installation & marking of surge arrestor / surge protection deviceat the main distribution board after the incoming breaker of type 1+2 testedforImax 100 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD |
| 330 | SITC of DISTRIBUTION Floor Panel,The panel shall be comprising of following & IEC 61439, Panel should be fully compartmentallised, wall mounted withM.S. Channel dully painted, fabricated of 14/16swg CRCA sheets completely derusted, chemically treated and powder coated with approved shade, ON - Off Indicating LED lamp, locking arrangements, withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage, current, frequency, power factor , ON hrs, kWh, EB and DG set metering and LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden as per SLD having following items:- MainI/O 630 Amp FP MCCB. Bus bar chamber TPN & E withaluminium bars Outgoing- 200A FP MCCB- 6 N0s. 100A FP MCCB- 3 N0s. .RA Sheet Attached) |
| 331 | SITC of Floor Panel,The panel shall be comprising of following & IEC 61439, Panel should be fully compartmentallised, wall mounted withM.S. Channel dully painted, fabricated of 14/16swg CRCA sheets completely derusted, chemically treated and powder coated with approved shade, ON - Off Indicating LED lamp, locking arrangements, withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage, current, frequency, power factor , ON hrs, kWh, EB and DG set metering and LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden as per SLD having following items:- MainI/O 200 Amp FP MCCB. 25 kA (Ics=100% of Icu) capacity Bus bar chamber TPN & E withaluminium bars 400 A.Outgoing- 100A FP MCCB- 6 N0s.63A FP MCB C series -4 Nos.32A FP MCB C series - 3 Nos. (RA Sheet Attached) |
| 332 | SUB- WORK - NO-3 Providing Fire Fighting, Fire Alarm System PA system toProposed Court Building (Stilt + Ground Floor + 4 Floors) ( 5 Court Halls)at Mahad, Tal. Mahad, Dist Raigad. Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 333 | Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850LPM at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 45kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP |
| 334 | Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180LPM at 70 to 50 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP |
| 335 | Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/ SSC/ DP |
| 336 | Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, inter connection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring &cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as followsa. Main fire pump(MFP) having capacity of 45 kW 1no (1 working)b. Jockey pump(JP) capacity of 5.5KW 2 nos(1 working +1 standby, alternate run per start in auto mode) D. 76HP main diesel engine driven fire pump |
| 337 | A3. For addition of capacity of main electric motor driven fire pump MFP (1 working) for hydrant system is more than 22kW, add as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgears and motor starters for main & jockey pumps along with necessary accessoriesfor main & jockey fire pumps MFP=(1working), JP = (1working + 1standby, alternate run per start in auto mode)For main electric motor driven fire hydrant system pump of 45kW capacity & relevant capacity jockey pump add Rs…. |
| 338 | B 4 For addition of fire sprinkler system to basic fire hydrant system control panel(FCP) which includes one main electric motor driven firepump MFP (1working) having __kW capacity& relevant capacity jockey pumps, add as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgearsbusbar and additional motor starters for main & jockey pumps along with necessary accessories with software & hardware for main & jockey fire pumps additional Sprinkler system MFP=(1working)@22kW, JP = (1working+1standby, alternate run per start in auto mode) @relevant capacity For main electric motor driven fire sprinkler system pump of 45kW capacity (1Working) & relevant capacity jockey pumps (1working+1standby, alternate run per start in auto mode,add Rs…. |
| 339 | D. For addition of 76HP main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode) & jockey fire pumps (1working+1standby, alternate run per start in auto mode) , The control for diesel engine comprises of automatic /manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps. |
| 340 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 341 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 342 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 343 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 344 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 345 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware. |
| 346 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP |
| 347 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 348 | Making cementconcrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps). |
| 349 | Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. |
| 350 | Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP |
| 351 | Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP |
| 352 | Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP |
| 353 | Supplying and erecting G.I. pipe ‘C’ class ERW 80 mm dia with necessary fittings complete as per specification no. FF-PP |
| 354 | Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP |
| 355 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP |
| 356 | Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP |
| 357 | Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system. |
| 358 | Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 359 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 360 | Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 361 | Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 362 | Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 363 | Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 364 | Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV |
| 365 | Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL |
| 366 | Supplying and erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FFFFA/NZ |
| 367 | Supplying and erecting 150 mm dia fire brigadeheadersuitable for supplying water in fire tank complete as per specification no. FF-FA/FBC |
| 368 | Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/FMC |
| 369 | Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT |
| 370 | Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 371 | Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG |
| 372 | Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 373 | Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP |
| 374 | Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve of size ( 400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200) mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 375 | Providing and fixing high-density polyethylene(HDPE) container one piece moulded triple layer water tank made out of high density polyethylene and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacityup to 20000 litres. |
| 376 | Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FFSPR. |
| 377 | Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. |
| 378 | SITC of Sprinkler Flexible drop pipes with 1500mm long(UL Listed) made of Corrugated SS Tubing to with stand 16 Bar pressure with welded reducer on one end to directly accommodate sprinkler & female check-nut on the other end to connect to the branch pipe with supports complete |
| 379 | SITC of self Luminous Exit Sign in accordance with BS5499as per sample approved by incharge (FIRE EXIT 300mm X 150mm) |
| 380 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity,interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP. |
| 381 | Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300μA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/ SD . |
| 382 | Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area\"s etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD. |
| 383 | Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \"Break Glass\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP. |
| 384 | Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. |
| 385 | Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU |
| 386 | Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM |
| 387 | Supplying,erecting, testing and commissioning of 2 core shielded cable complete asper specification no.FF-PA/MCC |
| 388 | Supplying,erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metreshielded cable and 3 Pin Professional XLR Connector, stereo jack complete asper specification no.FF-PA/MIC |
| 389 | Supplying, erecting,testing and commissioning 120 W amplifiersuitable to operate on 230VoltsA.C. / 12VoltsD.C. supply complete asper specification no. FF-PA/AFR |
| 390 | Supplying,erecting, testing and commissioning 15 to 30 Watts soundcolumn or ceiling mounted complete asper specification no. FF-PA/SOC |
| 391 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK |
| 392 | SUB- WORK - NO-4 Providing AC SystemtoProposed Court Building (Stilt + Ground Floor + 4 Floors) ( 5 Court Halls)at Mahad, Tal. Mahad, Dist Raigad.Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC |
| 393 | Supplying, installing, testing & commissioning split type variable speed invertertechnology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC |
| 394 | Supplying, installing, testing & commissioning split type room air conditioning unit 2.5TR to 2.7TR capacity with refrigerant R32 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/WAC |
| 395 | Supplying, installing, testing & commissioning split type room air conditioning unit 2.8TR to 3.2TR capacity with refrigerant R32 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC |
| 396 | Supplying 16 amp. 3 pin plug Top bakelite type of 230 V. A.C. supply. |
| 397 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. |
| 398 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete. |
| 399 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete. |
| 400 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system. |
| 401 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system. |
| 402 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater/AC system. |
| 403 | Supplying and erecting 25 mm dia. corrugated flexiblepolypropyleneconduit |
| 404 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 405 | Supplying, erecting & marking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 406 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 407 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 408 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 409 | Supplyinganderectingiron, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequered plates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterials dulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.( For AC OD Frame-) |
| 410 | SUB- WORK - NO-5 Providing passenger MR Lift Works toProposed Court Building (Stilt + Ground Floor + 4 Floors) ( 5 Court Halls)at Mahad, Tal. Mahad, Dist Raigad. Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 411 | Supplying and erectingmodular type switch 16Aduly erected on provided plate and box with wiring connections complete. |
| 412 | Supplying and erectingmodular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. |
| 413 | Supplying anderecting HMS PVC conduitFRLS grade 20 mm dia. with PVC accessorieson wall / ceiling as per specification No: WG-MA/CON. |
| 414 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. |
| 415 | Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 416 | Supplying and erecting mains with 1x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 417 | Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF |
| 418 | Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no FG-FAS/MSC |
| 419 | Supplying and erectingbulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 420 | Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 421 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 422 | Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 423 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 424 | Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 425 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 426 | Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO |
| 427 | Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO |
| 428 | Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core2.5sq. mm. copper conductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 429 | Supplying, erecting& terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10 sq. mm. copperconductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 430 | SITC of Electric Traction Passenger Liftwith Rated capacity :- 8 Passenger/544Kg Floors :- G+1 floor (2 Stops/2 Landings)Travel :- 3 to 4.2 mtrs Location of Lift Machine:- MR/MRL Rated speed :- 1.0mps VS Car/Landing door clear opening of 800 mm wide x 2000mm high· Clear Carsize1300mm wide x 1100 mm deep x2250mm high · Lift shaft available having clear size of1900 mm wide x 1900 mm (2 nos) &1900 mm wide x 2100 mm (1 nos) deep,1600 mm Pit depth, 4500 mm Overhead. · Doorstype :- COPO/TOPO Doors with framemade from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring,handrails,mirror,emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.·Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor andtravel direction protection, protection for phase loss at input or outputetc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility,auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters.The control panel duly wired with proper size & strength,copper wire forpower & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proofDome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machineof Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.·Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixingsteel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.\"· General: - Job includes entire procedure of obtaining all necessary erection permissions & \"\"License to Work the Lift\"\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.\" |
| 431 | SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete. |
| 432 | Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbonbased environment friendly back fill Ground Enhancing compoundcomplete with all materials, testing & recording the resultsas per specification no ESE -LA |
| 433 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessarycopperclampsfixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. 0.67*15*6= 60.3kg) |
| 434 | SUB- WORK - NO-6 Providing Pump system, Area Lighting and DG Set Work toProposed Court Building (Stilt + Ground Floor + 4 Floors) ( 5 Court Halls)at Mahad, Tal. Mahad, DistSupplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. X 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 435 | Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 436 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A,powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / CC foundation. |
| 437 | Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 438 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. ( Street Light Panel Foundation frame) |
| 439 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 440 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 441 | Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE |
| 442 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. & depth up to 90 cm) 50 mmoutside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. ( for Street Light Cable - 167 + for Pump Cable - 38) |
| 443 | Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 444 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 445 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP |
| 446 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no.EA-EP |
| 447 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete |
| 448 | Making cement concrete foundationin 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) |
| 449 | Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. |
| 450 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). Pump |
| 451 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 452 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 453 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 454 | Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 455 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW |
| 456 | Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 457 | Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF |
| 458 | Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no FG-FAS/MSC |
| 459 | Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. |
| 460 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 461 | Supplying, erecting & marking FPMCB 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 462 | Supplying, erecting & marking FPMCB63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 463 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 464 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame |
| 465 | Supplying, fixing and commissioning MCB type change over switch 4 pole, 63A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS |
| 466 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 467 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP |
| 468 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete (St Light Panel - 5 Kg + Pump - 5 kg + DG Panel - 5 kg) |
| 469 | Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 3.75 KW/5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 43 to 11m and discharge from 120 to 840 litres. per minute & pipe of Suction 65mm / Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP (1W - 1 S) |
| 470 | Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . |
| 471 | Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 472 | Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 473 | Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. |
| 474 | Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. DG Set Work |
| 475 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 476 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 477 | Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP ( DG Set Neutral) |
| 478 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. |
| 479 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP. |
| 480 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 250 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply,a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 42.30 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 425 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspectoras per specification no. GEN-DG |
| 481 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 200 kVA up to 250 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. |
| 482 | Supplying, installing, testing and commissioning FR, XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU (for DG Set control Cabeling) |
| 483 | Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. 7.5*3*0.45 |
| 484 | Making cement concrete foundationin 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included)(DG Set Foundation) 7.5*3*0.6 |
| 485 | SUB- WORK - NO-7Providing CCTV System toProposed Court Building (Stilt + Ground Floor + 4 Floors) ( 5 Court Halls)at Mahad, Tal. Mahad, Dist Raigad.Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 486 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 487 | Supplying and erecting 15m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 488 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 489 | Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC |
| 490 | Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 491 | Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete. |
| 492 | Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS |
| 493 | Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. |
| 494 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 495 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK |
| 496 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK |
| 497 | Supplying& erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S,maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64,Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB,MTBF 1000000 Hrs. HTTPS.RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD |
| 498 | Supplying& erecting 65\" professional LED display with 1920 *1080 ( Full HD) Display, suitable for 64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON |
| 499 | Supplying& erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following featuresImage Sensor : minimum 1/2.8\" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream,Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal,Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m.Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°.Power Supply : Support 12VDC & PoE,IP67, IK10 - Vandal Resistant.Built in micro SD/SDHC/SDXC card slot of minimum 128 GB,Built in microphone.minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled.Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM |
| 500 | Supplying& erecting of High definition 4/5 Megapixel IP IR Dome Camera with following featuresImage Sensor : minimum 1/2.8\" Progressive Scan CMOS,Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant,minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal,Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m.Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°.Power Supply : Support 12VDC & PoE,IP67, IK10 - Vandal Resistant.Built in micro SD/SDHC/SDXC card slot of minimum 128 GB,Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1.Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection.Operating temperature ( -30 to 60° C ) .Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol.RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM. |
| 501 | Supplying, installing, testing & commissioning of 64/80 Ch Network Video Recorder (NVR), suitable connect Min. 64 IP Cameras, up to 5 Megapixel Resolution, with HDMI 1/VGA 1 and HDMI 2/VGA 2 outputs provided, Atleast one HDMI output of 4K resolution, atleast one VGA output with output up to 1920 × 1080,Support H.265 or higher, H.264, MJPEG, Supports Redundant Dual Power,Incoming Bandwidth 320 Mbps with minimum 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O16/4, RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface,support multi brand network Cameras, ONVIF conformance,Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specificationss no. CCTV-NVR |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail