| 1 | WORKS |
| 2 | Dismantling Stone Masonry Rubble stone masonry in cement mortar. |
| 3 | Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level.In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc.Depth upto 1.5 m |
| 4 | Filling with locally available river sand at all levels including watering ramming consolidating and dressing complete including cost of sand. |
| 5 | Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m. |
| 6 | Supplying Chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 8 | Random rubble masonry with hard stone in foundation and plinth :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 9 | Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars |
| 10 | Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : |
| 11 | Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 12 | Centring and shuttering upto two stories or height upto 7.5 metre aboveplinth level including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform. |
| 13 | Centring and shuttering upto two stories or height upto 7.5 metre aboveplinth level including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 14 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (As per design mix) |
| 15 | Reinforced cement concrete work in beams, suspended floors,roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-25 Grade Concrete (1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) -As per design mix) |
| 16 | Brick work with bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 |
| 17 | Half brick masonry with FPS bricks of class designation 75 in superstructure above plinth level upto two stories:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 18 | Cement plastering including T&P, scaffolding, material and complete labour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : including Providing /mixing of synthetic fibers compulsorily complying with IS 16481:2022 of 06 mm/12 mm length to be mixed @ 0.25% by weight of Cement i.e. 125 gms per 50 kg Cement up to 900 gms per cum of Concrete/ mortar 1:4 (1 cement : 4 fine/ coarse sand) |
| 19 | Cement plastering including T&P, scaffolding, material and complete labour, including cost of water, curing, racking of joints etc. with 15 mm cement plaster on the rough side of single or half brick wall of mix : including Providing /mixing of synthetic fibers compulsorily complying with IS 16481:2022 of 06 mm/12 mm length to be mixed @ 0.25% by weight of Cement i.e. 125 gms per 50 kg Cement up to 900 gms per cum of Concrete/ mortar 1:4 (1 cement : 4 fine/ coarse sand) |
| 20 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 21 | Extra for using Marble printed / Granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finished tiles. |
| 22 | Extra for using size above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finished tiles in place of 300mm x 300mm size. |
| 23 | Providing and fixing 1st quality ceramic glazed vitrified tiles of colour standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorption less than or equal to 0.08% confirming to IS : 13753 & IS : 15622 in floor, steps etc laid on bed on neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on wall and pillar) Size 600mm x 600mm |
| 24 | Kota stone slab flooring 25mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : Area of each slab 2001 to 5000 sqcm |
| 25 | Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 26 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Green / Black1501 Cm2 to 3600 Cm2 Tiles |
| 27 | Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work |
| 28 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 29 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer. |
| 30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). |
| 31 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. |
| 32 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 33 | Providing and fixing double paitam (rebated) stone doors windows and ventilator frames of approved quality in cement sand mortar 1:4: size 125x100 mm |
| 34 | Providing and fixing factory made ISI marked steel glazed doors,windows and ventilators side /top /centre hung with beading and all members such as F7D, F4B, K11 B and K12 B etc. completeof standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and rivetted with 15x3mm lugs, 10cm long, embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of hinges, pivots, float glass panes with glazing clips and special metal sash putty of approved make and a priming coat of approved steel primer excluding the cost of metal beading and other fittings except necessary hinges or pivots complete as per approved design. |
| 35 | Stainless steel wire mesh of average width of aperture 1.56 mm and nominal dia. of wire 0.45 mm |
| 36 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenolormaldehyde resin in glue both sides including approved ISI marked Stainless Steel butt hinges fittings with necessary screws complete as per annexure \"A\" : 30 mm thick Decorative teak veneer both side |
| 37 | Random rubble dry stone Kharanja (soling) under floor. |
| 38 | Providing and Fixing Unplasticized poly Vinyl Chloride (UPVC) SWR pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make. |
| 39 | 75mm dia |
| 40 | 110mm dia |
| 41 | P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round ofsize 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100mm length extended on each side . All as per pre approved byEngineer in-charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 42 | Stone slab roofing on ground floor with fine grained stone slab 90mm average thickness from approved quarry including filling of joints slab in cement sand mortar 1:4 with ceiling pointing in cement sand mortar 1 : 3 complete as per specification for span: Up to 2.00 metre. |
| 43 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75mm deep chase |
| 44 | Grading roof for water proofing treatment with water proofingcompound Cement mortar 1:4 (1cement : 4 coarse sand) |
| 45 | Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :With bricks |
| 46 | Providing and fixing stainless steel ( Grade 304) railing made ofHollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (wherever required) andfitting the same with necessary stainless steel nuts and boltscomplete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, onthe top of the floor or the side of waist slab with suitablearrangement as per approval of Engineer-in-charge, (for paymentpurpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 47 | Supplying, erecting and fixing in position specified precast RCCbench made of RCC grade M-30 consisting of 2 Nos. “L” shapedbase support of thickness 100 mm back height 1000mm, front height450 mm, base width 420mm and 5 Nos. RCC planks of size of1500x100 x 50 mm and 1 Nos RCC planks of 150x200x50mmincluding joining all parts with galvanised nuts and bolts of suitablesize. All bolts to be sealed after assembly with nice finish andappearance and level complete in all respect as per direction ofengineer in-charge. Every bench should have a manufacturer’s logoof appropriate size Engraved at suitable place. |
| 48 | Providing corrugated G.S. sheet roofing including vertical/ curvedsurface fixed with polymer coated J or L hooks, bolts and nuts 8 mmdiameter with bitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead and including a coat of approved steelprimer and two coats of approved paint on overlapping of sheetscomplete upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and includingcutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275gm/m² |
| 49 | Providing, laying and spreading of granular sub-base by providing coarse graded Material (Table 400-2), spreading in uniform layers with motor grader on prepared surface, mixing BY MIX IN PLACE METHOD with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MoRT&H specification clause - 401 including all material, labour, machinery, lighting, guarding and maintenance of diversion. Grading - III Material |
| 50 | Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing complete as per clause 601, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. |
| 51 | Providing and fixing of 60mm thick precast cement concreteinterlocking paver block casted with rubber moulds in approvedreflective colour and design having minimum compressive strength of 300 kg/ sq cm. The CC paving blocks be laid on average 50mm thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer in-charge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. |
| 52 | Providing and laying M-30 Grade Edge blocks of size 0.30 Mtr x0.30 Mtr x 0.15 Mtr complete as per the shape and pattern approved by the engineer in-charge. |
| 53 | Construction of embankment with approved material obtained from borrow pit with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8-10 tonne to meet requirement of table 300-2 including cost of compensation for earth taken from private land complete as per MoRT&H specification clause 305. (Lead taken upto 5 km) |
| 54 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulated unsheathed flexiblecopper conductor 1.1 kV grade and 1.5 sq. mm nominal size FRPVC insulated unsheathed flexible copper earth conductor 1.1 kVgrade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virginmaterial PVC conduit & it\"s ISI marked (IS:3419-1988) accessories,round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box withearth terminal, 10A Modular switch, Modular face plate with gridplate, 3 pin ceiling rose / Holder /3 way connector, screws, makingconnections, testing etc. as required. For specification of copperConductor, Phenolic Laminated sheet\"s & Electrical/ Wiringaccessories refer Chapter-53, 54 & 56 for additional technicalparameters of product / work refer Annexure \"A\" attached with thisBSR |
| 55 | Short point (up to 3 mtr.) |
| 56 | Medium point (up to 6 mtr.) |
| 57 | Long point (up to 10 mtr..) |
| 58 | Providing & Fixing of modular type switch/ bell push duly ISI marked(IS :3854) with CM/L no. printed and made out of unbreakable andfire retardant vergin UV Stabilized Polycarbonate with brassterminals and captive screws & silver alloy contact tip with IP-20rating ,minimum width of switch toggle( PUSH PART ) should notless then 20mm, including all as per pre approved by Engineer incharge,making connections, testing etc. as required. For additionaltechnical parameters of product / work refer Annexure \"A\" attachedwith this BSR 10 A one way switch |
| 59 | 16 Amp. 1 Module switch With Led Indicator |
| 60 | Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , including all as per pre approved by Engineer incharge,making connections, testing etc. as required. For additionaltechnical parameters of product / work refer Annexure \"A\" attachedwith this BSR 6 A 3/5 pin shuttered socket |
| 61 | 6/16 A shuttered socket |
| 62 | Providing & Fixing of modular type 120 W Step Fan regulator dulyISI marked (IS 11037:1984 ) with CM/L no. printed made out ofunbreakable and fire retardant vergin poly carbonate with brassterminals and captive screws & silver alloy contact tip with IP-20rating , including all as per pre approved by Engineer incharge,making connections, testing etc. as required. For additionaltechnical parameters of product / work refer Annexure \"A\" attachedwith this BSR 5 step fan regulator 2 Module 360 dgree rotating |
| 63 | Blanking plate |
| 64 | Providing & Fixing of following size mounting grid plates with coverplates made from fire retardent UV established high-performanceengineering plastic suitable for all universal metal boxes for frontinstallation & removal direct fit type complete in all respect.All as perpre approved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached withthis BSR .4 Module |
| 65 | 8 Module |
| 66 | 12 Module |
| 67 | Providing & Fixing of Wiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR4/5 Module |
| 68 | 6 / 8 module |
| 69 | 10/12 Module |
| 70 | Supplying and drawing FR PVC insulated & unsheathed flexiblecopper conductor as per PWD specification for electrical Works withISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wireshould be made from 99.90 % purity copper, class 5 stranding inacc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for lesschances of oxidization, insulation PVC type A/C/D , flame retardantas per IS 10810-53, better amperage rating as per IS:3961 part 5, inexisting surface or recessed PVC/ MS conduit/casing cappingmaking connections with Copper Lugs of suitable size,Ferrules,testing etc. as required. OEM Must have its own in houseNABL lab setup for all testing facilities for wires. For additionaltechnical parameters of product / work refer Annexure \"A\" attachedwith this BSR 1 x 1.5 sq.mm |
| 71 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 72 | 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. |
| 73 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 74 | Providing & Fixing of BEE Star rated copper wounded double ballbearing capacitor start, aluminium body & Metallic blade ceiling fanConforming to all the performance requirements laid down in IS374:2019 including all amendments, as applicable ; & Carry BISlicensing (i.e. ISI marking) with down rod up to 80 cm with secondarysupport safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvcinsulated flexible copper conductor making connection testing etc.as required. All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure\"A\" attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 75 | Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing 900/1400 RPM single phase Exhaust fanconforming to IS:2312 ISI marked in existing opening includingmaking connections testing etc. as required. All as per pre approvedby Engineer in-charge. For additional technical parameters ofproducts/ work , refer Annexure \"A\" attached with this BSR . 450 mm sweep(900/1400 RPM) |
| 76 | Providing & Fixing of IP-20 LED Recessed / Surface Mounted,Round / Sqaure SMD Mid Power LED Downlight with power coateddie-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screenprinting on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work ,refer Annexure \"A\" attached with this BSR .Minimum lumen output 330 lm |
| 77 | Providing & Fixing of IK08 IP-66 protected high power LED floodlight system with single piece Pressure diecast aluminium housing,toughened glass diffuser with suitable lenses on LED to achievevarious beam angles, of high power LED of 3 to 5 watt each .Integrated potted driver as a unique BIS R number having efficiencymore than 85 % and in compliance to BIS certified and Trade markcertificate. The System level Luminaire efficacy >=125 lm/ wt. LEDdriver Input Voltage AC 120 to 270 V AC with High voltage Cutoff@>=300 V AC and Auto resetting Safety .Power Factor >0.95 ,THD(I) <10% , driver current <=750mA. driver should be Phase tophase protection of 440 V for 4 Hrs. Electrical Connector , SurgeProtection Min >=4KV internal and 10KV external but inside drivercompartment, System life of 50000 Burning hours with 70% of InitialLumens maintained, CRI>70 and CCT 5700K ±355K.Manufactures Word Mark/Name Engraved/Embossing/Screenprinting on die cast housing to allow traceability/authenticity. Fixtureshall be IS 10322 Complianced.OEM Must have its own in houseNABL lab setup for all testing facilities for LED fixtures.(LM79/LM80) Certificate/ report with liable warranty ofproduct/accessories from OEM shall be submitted. All as per preapproved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached withthis BSR .High Power LED Flood Light Minimum lumen output 12400 lm |
| 78 | Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holderwith CM/L no. printed and made out from industrial gradePolycarbonate or fire resistant ABS material, brass terminal &captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in-charge. For additionaltechnical parameters of products/ work , refer Annexure \"A\"attached with this BSR . |
| 79 | Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pinceiling rose with CM/L no. printed and made out from industrialgrade Polycarbonate or fire resistant ABS material, brass terminal &captive screws including making connection testing etc. asrequired.All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure\"A\" attached with this BSR . |
| 80 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as required in recess including cutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports byany NABL accredited lab for the conduit shall be submitted before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . MMS ( IS:9537 P - III ) PVC conduit 25 mm |
| 81 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10kA breaking capacity (B/ C/D tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC, minimum phase termination capacity of35sq.mm. , conductor line load reversibility , IP 20 contact protectionand fitted in existing distribution board/sheets, minimum electricaloperation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80A & above rating including making connections, testing etc. asrequired. OEM shall have submit NABL / CPRI / ERDA accrediatedlab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work referAnnexure \"A\" attached with this BSRSingle pole MCB 6 A to 32 A rating |
| 82 | 40 A rating |
| 83 | Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilizationcategory, 4KV impulse withstand voltage, true contact indication,Red colour dolly / lever shall have single mould covering overallpoles for operation , two position din rail mounting, minimum phasetermination capacity of 35sq.mm. IP 20 contact protection and fittedin existing distribution board / sheet including making connections,testing etc. as required. OEM shall have submit NABL / CPRI /ERDA accrediated lab type test reports & All as per pre approvedby Engineer in-charge.For additional technical parameters of product/ work refer Annexure \"A\" attached with this BSRDouble pole isolator63 A rating |
| 84 | Providing & Fixing of Recessed/surface mounting heavy dutyhorizontal type Double Door ( Metal / Glazed )Distribution board withMetal end box made out from Galvanized steel / CRCA sheet notless then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1& 3, powder painted complete with reversible door (for double doorDB only )100 amp. insulated copper bus bar/shorting link , copperneutral link, copper earth link , color coded interconnecting wire setof suitable rating and din bar,masking sheet, making internal DBterminations with copper lugs, Ferrules, detachable gland plate,including making connections, testing etc. as required. OEM shallhave submit NABL / CPRI / ERDA accrediated lab type testreports & All as per pre approved by Engineer in-charge. Foradditional technical parameters of product / work refer Annexure \"A\"attached with this BSR Metal door (single phase) IK-09 and IP-43 with Metal end box 16 Way (16+2) |
| 85 | 8 Way (8+2) |
| 86 | Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate ofsize 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below theground level with 20 mm dia. G.I. \"B\" class watering Pipe ,includingall accessories like nut, bolts, reducer, nipple, wire meshed funnel,and Heavy duty weather proof poly-propylene earth pit chamber withlockable Jam free lid suitable for safe working load 5000 Kg or moreof size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. andHeight 250 to 300 mm. and embodying the pipe complete withalternate layers salt and coke/ charcoal, testing of earth resistancefor value of 5 ohms or less as required & must record by engineerin-charge during site visit and ensure to enter in measurmentbook.All as per pre approved by Engineer in-charge. For additionaltechnical parameters of products/ work , refer Annexure \"A\"attached with this BSR . |