| 1 | Designing of Fire detection and alarm system, wet riser and sprinkler Systemfor the reconfiguration of Terminal buildingincluding preparation and submission of shop drawings, as-built drawings submission of NOC from state fire deptartment / regulatory authority etc. as per latest IS and NBC standards. |
| 2 | Supply, Installation, Testing & commissioning of UL / EN listed intelligent addressable multi criteria detector with inbuilt fault isolator / isolator base withvisible LED suitable for 2 wires loop connection, complete with plug into common separate base & housingcomplete with connections etc. and shall be compatible with existing Siemens makefire alarm control panel etc. and to be fixed below / above false ceiling roof and concealed space with necessary support complete as required and as per direction of Engineer in charge. |
| 3 | Supply, Installation, Testing & commissioning of UL / EN listedintelligent addressable Manual call station suitable for semi flush mounting, IP 54, with inbuilt fault isolator / isolator module compatible with existing Siemens make fire alarm control panel including the word Fire appearing on the front with connections etc. complete as required and as per direction of Engineer in charge. |
| 4 | Supply, installation, testing and commissioning of UL / EN listed addressable Hooter-cum-strobe with inbuilt fault isolator / isolator module with adjustable sound level compatible with existing Siemens make fire alarm control panelcomplete with termination etc.and to be fixed at wall/ surface etc. complete as required and as per direction of Engineer in charge. |
| 5 | Supplying, installation, testing & commissioning of UL / EN listed Response Indicator i/c Mounting Boxes installed on surface/ recessed having two LED complete with all connections and compatible with existing Siemens make fire alarm control panelwith termination/ connection etc.and to be fixed at wall/ surface etc. complete as required and as per direction of Engineer in charge. |
| 6 | Providing, installation, testing & commissioning of UL / EN listed addressable Monitor Module (input module) compatible with existing Siemens make fire alarm control panel complete with connection/ interconnection etc complete as required and as per direction of Engineer in charge. |
| 7 | Providing, installation, testing & commissioning of UL / EN listed addressable Control Module / Relay Module (output module) compatible with existing Siemens make fire alarm control panel complete with connection/ interconnection etc complete as required and as per direction of Engineer in charge. |
| 8 | Supplying of 2Cx1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by XLPE Insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath etc complete as required and as per direction of Engineer in charge. |
| 9 | Laying of 2Cx1.5 sqmm fire survival armoured cable, 600/1000V rated in the existing surface / wall with suitable GI saddle complete as required and as per direction of Engineer in charge. |
| 10 | Supplying, Installing, Testing and Commissioning ofUL / EN listed XDL-C LOOP CARD compatible with existing existing Siemens make fire alarm control panelwith connection/ interconnection etc complete as required and as per direction of Engineer in charge. |
| 11 | Supplying, Installing, Testing and Commissioning ofUL / EN listed Addressable motorised auto align Beam Detector with transmitter, receiver, etc. including providing suitable monitor module for integrating with existing Siemens make fire alarm control panel etc complete as required and as per direction of Engineer in charge. |
| 12 | Supply and fixing of metal junction box for mounting of detectors / devices complete with connections etc. as required and as per direction of Engineer in charge. |
| 13 | Programming and operationlize of the newly installedaddressable type multifunctional detectors, Hooter, MCP, response indicator, beam detectors etc in the existing Siemens make fire alarm control panel complete as required and as per direction of Engineer in charge. |
| 14 | Providing, fixing, testing & commissioning of 15mm dia size suitable for sustaining the seat & water hammer effect, quartzoid bulb type sprinklers (UL, FM approved) of rating 68 degree centigrade with required accessories : |
| 15 | a) Pendent Sprinkler |
| 16 | b) Horizontal side wall sprinkler |
| 17 | c) Concealed sprinkler |
| 18 | d) Upright Sprinkler |
| 19 | Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.a)1200 mm |
| 20 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 21 | 25 mm dia |
| 22 | 32 mm dia |
| 23 | 40 mm dia |
| 24 | 50 mm dia |
| 25 | 65 mm dia |
| 26 | 80 mm dia |
| 27 | 100 mm dia |
| 28 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 29 | 80 mm dia |
| 30 | 100 mm dia |
| 31 | Providing, installation, testing and commissioning of CI dual plate non return valve PN 16 of following sizes confirming to complete with rubber gasket, GI bolt, nuts,washers etc. as required. 100 mm dia |
| 32 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal |
| 33 | Supplying&fixing63mmdiagunmetalshortbranch pipewith20mmnominalinternal diameter sizenozzle conforming to IS 903suitable forinstantaneous connection to interconnect hose pipe coupling as required :Gun metal |
| 34 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun Metal |
| 35 | Supplyingand fixing of Double door MS hose cabinet of sizenot less than 0.9 x 0.6 x 0.5 mtr made out of MS sheet 2mm thick suitable to accommodate hydrant with valve, 2 nos 15mtr. long hose pipe, 1 no. branch pipe, etc having central opening and 6 mmthick glazedglass doors (02 nos) suitably marked on the outside with the letter\"FIRE\"i/cnecessary lockingarrangement, mounting legs / concrete pedestal andduly painted with one coat of primer and two coats ofsynthetic enamel paint of post office red shade complete as required. |
| 36 | Supply, installation , testing and commissioning of pressure gauge of 150 mm dia with syphon tubing, mounting accessories,0-21 kg/ sq.cm range with 15 mm dia stop cock valve, piping etc as required. |
| 37 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 38 | Cutting of existing MS pipe for testing and connecting temporary dummy joint in the existing fire hydrant line various location at terminal building and rejointing MS pipe with the help of Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. as required and as per direction of Engineer in charge. |
| 39 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |