}

Tender For Idamalayar Hep: Renovation Of Dormitory At Idamalayar - Part A- Civil Work:2.6.1Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas(Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Inclu, Ernakulam-Kerala

Kerala State Electricity Board has published Tender For Idamalayar Hep: Renovation Of Dormitory At Idamalayar - Part A- Civil Work:2.6.1Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas(Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Inclu. Submission Date for this Tender is 11-04-2025. Building Work Tenders in Ernakulam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

48268034
Corrigendum : Tender For Idamalayar Hep: Renovation Of Dormitory At Idamalayar - Part A- Civil Work:2.6.1Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas(Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Inclu
Open Tender
Indian
Kerala
Ernakulam
11-04-2025

Tender Details

Tender For Idamalayar HEP: Renovation of Dormitory at Idamalayar - Part A- Civil Work:2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavatedearth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds ofsoil 2 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers notexceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 3 15.7.4Demolishing brick work manually / by mechanical means including stacking of serviceable material anddisposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.Incement mortar 4 15.56Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposalof rubbish to the dumping ground within 50 metres lead. 5 15.12.1Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats,architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below 6 15.9.2Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceablematerial and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charges:In cement mortar 7 15.23.1Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metreslead.For thickness of tiles 10 mm to 25 mm 8 50.6.2.1Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest availablesize confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1cement :6 coarse sand) etc complete 9 14.1.1Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, includingcutting the patch in proper shape, raking out joints and preparing and plastering the surface of the wallscomplete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar1:4 ( 1 cement : fine sand) 10 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 11 4.1.5Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mmnominal size) 12 od306685/2023_2024Providing and fixing false ceiling with calcium silicate sheet 8 mm thick at all height including providingand fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized withzinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm center to centre, one flangefixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleatfixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size andother end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of1200 mm center to center, including cost and conveyance, labour charges and all other incidentalcharges etc complete as per the direction of Engineer In-Charge 13 od306686/2023_2024supplying carpenters for repair of doors, windows, ventilators, shelves etc. as per the directions of thedepartment officers 14 11.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours andshades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the jointswith white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 15 8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specifiedby the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black ofany size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bedof cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm,including pointing in white cement mixed with pigment of matchingshade complete. 16 15.28.2Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50metres lead of :Asbestos Sheet 17 od306687/2023_2024dismantling , removing and lowering planked sheeting ,boarded floor, ceilings etc and stacking materialswithin a distance of 150 m 18 10.1Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer all complete. 19 10.16.1Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., includingcutting, hoisting, fixing position and applying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete.Hot finished welded type tubes 20 od306688/2023_2024Fabricating and fixing GI welded mesh coverings using 4 mm size welded mesh to prevent entry ofrodents including the cost of materials (excluding cost of frame work) and labour for fixing the same,painting two coats of synthetic enamel paint over a coat of iron primer etc. complete. 21 12.50Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation asapproved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 gramsper sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet andpolyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum toavoid scratches during transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm)with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shape wherever required. 22 12.51.1Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) totalcoated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinccoating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on bothside of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screwscomplete:Ridges plain (500-600 mm) 23 21.1.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built upstandard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS :733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up thegaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereverrequired including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steelscrews, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodisedtransparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) 24 21.1.2.1For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and makingprovision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasketrequired (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed torequired shade according to IS : 1868, Minimum anodic coating of grade AC 15) 25 21.3.1Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDMrubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer -in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0mm thickness 26 13.80Providing and applying white cement based putty of average thickness 1 mm, of approved brand andmanufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 27 13.43.1Applying one coat of water thinnable cement primer of approved brand and manufacture on wallsurface:Water thinnable cement Primer 28 13.52.1Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as permanufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.Onsteel work 29 od306689/2023_2024Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Oneor more coats on old work(if the desired colour and even finish is not attained in one coat , more coatshave to be applied) after rubbing with sand paper and brush and cleaning the surface etc. as perspecifications and as per directions of departmental officers at site.-Inside wall finishing-Details of cost for1 sqm. (Modified from 13.98.1) 30 od306690/2023_2024Finishing outside walls one or more coats applied @ 1.67 ltr/10 sq m(if the desired colour and even finishis not attained in one coat , more coats have to be applied) with Premium Acrylic smooth exterior paint ofrequired shade on old work after rubbing with sand paper and wire brush and cleaning the surface etc. asper specifications and as per directions of departmental officers at site-Details of cost for 1 sqm ( As PerDSR Data No: 13.111.1) 31 14.34Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessarybrass screws etc. to suit shutter thickness complete 32 4.1.3Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) 33 13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two ormore coats on new work 34 50.9.1.1Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framedand fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs ordash fastener shall be paid for separately), using good quality Anjili wood /jack wood 35 50.9.3.1Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows,30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size withnecessary screws, excluding paneling which will be paid for separately, all complete as per direction 0fEngineer in- charge. using Anjili/ Jack wood 36 50.9.4.1Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters fordoors, windows and clerestory windows (Area of opening for panel inserts excluding portion insidegrooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40mm thick using good quality Anjili/ Jack wood 37 od310961/2023_2024Supplying and fixing PVC door (frame and shutter) of approximate size 90 cmx 210 cm including cost offittings such as butt hinges, tower bolt,locking arrangements, handles including labour. 38 4.1.4Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mmnominal size) 39 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position andbinding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 40 5.1.2Providing and laying in position specified grade of reinforced cement concrete, excluding the cost ofcentering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarsesand :3 graded stone aggregate 20 mm nominal size 41 8.2.2.1Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machinecut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarsesand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, includingrubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at alllevels.Granite of any colour and shadeArea of slab upto 0.50 sqm 42 5.3Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings,balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floorfive level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement :1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 43 17.10.2.3Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets andstainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the wallswherever required:Kitchen sink without drain board470x420 mm bowl depth 178 mm 44 50.9.11.1Providing and fixing Thomson Multi wood board or equivalent make paneling 12 mm thick, to frame,backing or studding with screws etc. complete ( Frames, backing or studding to be paid separately) asper the direction of site Engineer-in-charge. 45 od107819/2024_2025Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grademade by block making machine with strong vibratory compaction, of approved size, design & shape,laid in required colour and pattern over and including 50 mm thick compacted bed of 6mm metal allcomplete as per the direction of Engineer-in-charge 46 60.7.1DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good qualityblasted rubble including packing to compactness to lines and levels cost and conveyance of all materialslabour charges etc. complete as per direction of Departmental officers at site 47 Part B- Sanitary Works: 18.7.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & coldwater supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes 48 18.7.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & coldwater supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testingof joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominalouter dia pipes 49 18.51.1Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms.15 mm nominal bore 50 18.53.1Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved qualityconforming to IS: 893115 mm nominal bore 51 50.17.1.1Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etccomplete as per the direction of site Engineer-in-charge 52 50.17.1.3Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials andlabour charges etc complete as per the direction of site Engineer-in-charge. 53 50.17.1.5Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost ofmaterials and labour charges etc complete as per the direction of site Engineer-in-charge. 54 50.18.9.9.1Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching,refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 55 50.18.9.22.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 110 mm dia Elbow 56 50.18.9.22.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement- 110 mm dia Bend 57 50.18.9.22.6Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 110x110x110 mm dia Door tee 58 50.18.9.22.8Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVCsolvent cement -110 dia vent cowl 59 50.18.9.22.10Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVCsolvent cement -110 mm dia End Cap 60 17.2.1Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seatand lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting andmaking good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seatand lid 61 18.22.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 62 18.17.3Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mmnominal bore 63 50.18.7.3.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall 64 50.18.7.4.2Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall 65 50.18.7.5.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge 40 mm dia 6Kgf/cm2 - Internal work - Exposed on wall 66 50.18.7.6.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall 67 50.18.9.17.1Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . Thisincludes jointing of pipes with one step PVC solvent cement and testing of joints complete as perdirection of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 68 50.18.9.20.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 63 mm dia Elbow 69 50.18.9.20.2Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement -63 dia 45 degree Elbow 70 50.18.9.20.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 63 mm dia Bend 71 50.18.9.20.5Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVCsolvent cement - 63x63x63 mm dia Tee 72 50.18.9.20.7Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 63 mm dia vent cowl 73 50.18.9.20.10Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 63x50 mm dia Reducer 74 50.18.9.22.2Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 110 mm dia 45 degree Elbow 75 50.18.9.22.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVCsolvent cement 110x110x110 mm dia Tee 76 17.7.6Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass wasteof standard pattern, including painting of fittings and brackets, cutting and making good the wallswherever require:White Vitreous China Angle back wash basin size 400x400 mm with single 15 mm C.P.brass pillar tap 77 Part C -Electrification Work1.21.1Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm 78 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm 79 od315262/2023_2024supply and fixing of ISI marked round type 25 mm pvc junction box 4 way 80 od315263/2023_2024Supply and fixing of ISI marked round type 25 mm pvc junction box 3 way 81 od315264/2023_2024Supply and fixing of ISI marked round type 25 mm pvc junction box 2 way 82 od327412/2023_2024supply and fixing of ISI marked round type 25mm steel junction box of 1way 83 od315265/2023_2024Supplying and fixing of ISI marked round type 20mm PVC junction box 1 way 84 od315266/2023_2024Supplying and fixing of ISI marked round type 20 mm pvc junction box 4 way 85 od315267/2023_2024Supply and fixing 20mm of ISI marked round type junction box 3 way 86 od315268/2023_2024Supply and fixing of 20 mm ISI marked 2way junction box 87 1.17.1Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm 88 1.17.2Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm 89 1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm 90 1.17.4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm 91 1.17.5Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm 92 1.17.6Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm 93 1.17.7Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.7 x 1.5 sq. mm 94 1.17.8Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.8 x 1.5 sq. mm 95 1.17.9Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm 96 1.17.11Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm 97 1.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm 98 1.17.13Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm 99 1.17.14Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm 100 1.17.20Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm 101 1.17.22Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm 102 1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.5/6 amps switch 103 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.15/16 amp switch 104 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 105 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 106 1.24.8Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.Bell push 107 1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plateswitch box including connections but excluding modular plate etc. as required. 108 1.26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modularplate as required. 109 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.1 or 2 Module (75mmX75mm) 110 1.27.3Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.4 Module (125mmX75mm) 111 1.27.4Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.6 Module (200mmX75mm) 112 1.27.6Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.12 Module (200mmX150mm) 113 1.22.2Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable sizeof phenolic laminated sheet cover in front including painting etc as required.100 mm X 100 mm X 60 mmdeep 114 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincludingconnection etc as required. 115 1.38Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 116 od319043/2023_2024Supply ,installation, connection, testing commissioning of exhaust fan in the existing opening, includingmaking good the damage,,etc as required up to 450 mm sweep 117 1.58Supplying and fixing PVC batten/ angle holder including connection etc. as required 118 2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12way, Double door 119 2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole 120 2.11Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 121 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB completewith connections, testing and commissioning etc. as required.40 amps 122 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. as required.40 amps 123 2.14.3Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. as required.63 amps 124 2.12.2Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB completewith connections, testing and commissioning etc. as required.63 amps 125 od315270/2023_2024Installation, testing and commissioning of pre - wired, LED TUBE 20W , complete with all accessories .directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor,single core cable and earthing etc. as required. 126 od315271/2023_2024Supplying and fixing 3 leaf fan of leading manufacture as approved by the engineer in charge 127 od315272/2023_2024Supplying and fixing 9 w LED Bulb of leading manufacture as approved by the engineer incharge 128 od315273/2023_2024Supply and fixing of 50 Watt LED steet light output > 105lumen/W 4000-6000 K with IP 66 protection LEDChip make Cree/Lumilled/Nichea with power factor >0.95 at full load, internal surge protection up to 8KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD <10%,power factor >0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartmentshould be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third partylab to be produced mentioning chip manufacturer) 129 od317603/2023_2024Earthing with 21mm dia ,1.5meter long ,500 micron copper coting earthing rod and using 25kg graphitecarbonite earthing compound 130 5.13Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm diaG.I. pipe from earth electrode including connection with copper thimble excavation and re-filling asrequired. 131 5.14Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 04-04-2025 Date Corrigendum Date 11-04-2025

Key Value

Document Fees
INR 5900 /-
EMD
INR 50000.0 /-
Tender Value
INR 79.74 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail