| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, upto any depth, including getting out the excavated soil and disposal of surplus excavated soils as directed by Engineer in charge i/c carriage of material in all leads and lifts. All kinds of soil. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth upto all lead and liftas directed by Engineer-in-charge including carriage of material in all leads and lifts.. |
| 3 | Excavating, supplying and filling of good earth (including royalty) by mechanical transport upto all lead & lift also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete i/c carriage of material in all leads and lifts. |
| 4 | Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer in charge i/c carriage of material in all leads and lifts. |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form work for complete including carriage of material in all leads and lifts. |
| 6 | Suspended floors, roofs, landings, balconies and access platform. |
| 7 | Lintels, beams,plinth beams, girders, bressumers and cantilevers. |
| 8 | Columns, Pillars, Piers, Abutments, Post and Struts |
| 9 | Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses , plinth and string courses fillets, kerbs and steps etc. |
| 10 | Edges of slabs and breaks in floors and walls, under 20Cm wide |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) i/c carriage of material in all leads and lifts. |
| 12 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns,piers, abutments, pillars, posts struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. upto 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) i/c carriage of material in all leads and lifts. |
| 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering finishing and reinforcement. 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size)i/c carriage of material in all leads & lifts. |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 Cement 1.5 oarse sand 3 graded stone aggregate 20 mmnominal size) i/c carriage of material in all leads and lifts. |
| 15 | Steel reinforcement for R.C.C work including straightening, cutting,bending, placing in position and binding all complete above plinth level. TMT bars of grade Fe-500D or morei/c carriage of materils in all leads and lifts. |
| 16 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections i/c carriage of material in all leads and lifts. |
| 17 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)i/c carriage of material in all leads and lifts. |
| 18 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement : 4 coarse sand) i/c carriage of material in all leads and lifts. |
| 19 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete i/c carriage of material in all leads and lifts. |
| 20 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (a)In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works i/c carriage of material in all leads and lifts. |
| 21 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. complete i/c carriage of material in all leads and lifts. Size of tile 600X600 mm (Kajaria,NITCO/ Somany /Johnson or equivalent). |
| 22 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. i/c carriage of material in all leads and lifts.Size of tile 600X600 mm (Kajaria,NITCO/ Somany /Johnson or equivalent). |
| 23 | Providing and fixing 10mm thick anti skid water proof stain and impect resistent heavy duty vetrified tiles any size/colour manufactured of approved shade and colour in flooring, treads of steps and landings laid over 12mm thick cement mortar 1:3 (1 cement : 3 sand) jointed with cement slurry mixed with pigment to match the shade of tiles as required complete including carriage of material in all leads & lifts. (Kajaria,NITCO/ Somany /Johnson or equivalent). |
| 24 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete i/c carirage of material in all leads and lifts. |
| 25 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60 mm thick C.C. paver block of M-35 grade with approved colour design & pattern (Confiming to BIS Specification). |
| 26 | Providing and fixing 0.60mm thickprepainted steel sheet in roofing withhot dipped metallic zinc coated sheetwith top coat of regular modifiedpolyster (RNP) organic coating of 20microns over 5 microns primer coatingto back coat of polyster of 5 micronsover 5 microns primer coating i/c fixingwith prepainted iron J or L hooks, boltsand nuts 6mm dia metre withprepainted limpet and rubber washerscomplete with all accesoriees asrequired as per the direction ofEngineer-in-charge i/c carriage of material in all leads and lifts. |
| 27 | Providing and fixing ridges or hips 60cm overall with 0.60mm thick prepainted steel sheets in roofing withhot dipped metalic zinc coated sheetswith top coat of regular modifiedpolyster organic coating of 20 micronsover 5 microns primer coating + back coat of polyster of 5 microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts &nuts 6mm dia & prepainted G.I. limpetand bitumen washers complete with allaccessories as required as per thedirection of Engineer in Charges i/c carriage of material in all leads and lifts. |
| 28 | Providing and fixing valley 60 cm overall0.60mm thick prepainted steel sheet inroofing with hot dipped metalic zinccoated sheet with top coat of regularmodified polyster organic coating of 20 micron over 5 microns primer coatingback coat of polyster of 5 microns over 5 microns primer coating i/c fixing withprepainted iron J or L hooks, bolts andnuts 6mm dia with prepainted G.I.limpet and bitumen washers completewith all accessories as required as perthe direction of Engineer-in-charge i/c carriage of material in all leads and lifts. |
| 29 | Provding and fixing M.S. BP sheet 1.66 to 2 mm thick in eaves board/ facia/ soffits/ ceiling including cutting, fixing and welding to steel roof members and applying a coat of red lead primer complete as per the instruction of Engineer-in- charge (base members of steel work shall be meadured and paid for separately) including carriage of material in all leads & lifts. |
| 30 | Making Khurras 45 X 45 Cm with average minimum thickness of 5 cmcement concrete 1:2:4 over PVC sheet 1mx1mx1m x400 mircron finished with 12 mm cement plaster 1:3and coat of neat cment, rounding the edges and making and finishing the outlet complete i/c carriage of material in all leads and lifts. |
| 31 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 32 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Bend 87.5° 110 m dia. |
| 33 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.including carriage of material in all leads and lifts:-110 mm diameter |
| 34 | 15 mm cement plaster on rough side of single or half brick wall of mix upto all heights/depthsin mement Mortor 1:6 (1 cement: 6 coarse sand).i/c carriage of material in all leads & lifts |
| 35 | 20 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) upto allheightsi/c carriage of material in all leads & lifts. |
| 36 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) upto any height /Depthi/c carriage of material in all leads & lifts. |
| 37 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer including carriage of material in all leads & lifts |
| 38 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm including carriage of material in all leads & lifts. |
| 39 | Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on decorated wall surfaces (one coat ) to give an even shade after throughly brushing the surface to remove all dirt , loose or softned paint i/c carriage of material in all leads and lifts. |
| 40 | Extra over item No. 34.00 for every subsequent coat of water proofing cement paint of approved brand and manufacture i/c carriage of material in all leads and lifts. |
| 41 | Finishing with Delux Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting steel work with Delux Multi surface paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.80ltr/10 sqm of approved brand and manufacturer i/c carriage of material in all leads and lifts. |
| 42 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete i/c carriage of material in all leads and lifts. |
| 43 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 Sq.meters and under, including cutting the patch in proper shape,raking out joints and preparing and plaaster the surface of the wall complete, including disposal of rubbish to the dumping ground all complete as per direction of Engineer in charge. With cement mortar 1:4 (1cement:4 coarse sand).i/c carriage of material in all leads and lifts. |
| 44 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 mtrs lead as per direction of Engineer in charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix).i/c carriage of material in all leads and lifts. |
| 45 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge i/c carriage of material in all leads and lifts. |
| 46 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 47 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer in-charge. (Old CC paver blocks shall be supplied by the department free of cost) i/c carriage of material in all leads and lifts. |
| 48 | Providing and fixing G.I pipes complete with G.I fittings and clamps i/c cuttingand making goof the walls etc. i/c carriage of material in all leads and lifts.Jindal/TATA or its equivalent |
| 49 | 15 mm dia nominal bore. |
| 50 | 20 mm dia nominal bore. |
| 51 | Making connection of G.I distribution branch with G.I main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. Complete i/c carriage of material in all leads and lifts. (a) 25 to 40 mm nominal bore.Jindal/TATA/UNIK or its equivalent |
| 52 | Providing and fixing full way valve (brass) of approved quality, high of low pressure, with palstic floats complete i/c carriage of material in all leads and lifts.(Leader/Zoloto or equivalent) |
| 53 | 15 mm nominal bore. |
| 54 | 20 mm nominal bore. |
| 55 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank i/c carriage of material in all leads and lifts. |
| 56 | Providing and fixing white vitreous china pedastal type water closet (European type W.C pan) with seat and lid, 10 litre low level white PVC flushing cistern, including flush pipe, with manually controlled device ( handle lever), confirming to IS :7231 with all fittings and fixtures complete, incuding cutting and making good the walls and floors wherever required.(a) W.C pan with ISI marked solid plastic seat with lid i/c carriage of material in all leads and lifts.(Hindware/Cera or its equivalents) |
| 57 | Providing and fixing white wash basin with C.I brackets, 15mm C.P brass pillar taps, 32 mm C.P brass waste of standard pattern, including paiting of fittings and brackets, cutting and making goof the walls wherever require i/c carriage of material in all leads and lifts.(a) White Vitreous China Flat back wash basin size 550X400 mm with single 15 mm C.P brass pillar tap. (Hindware/Cera or its equivalents) |
| 58 | Providing and fixing white vitreouschina pedastal for wash basin completely recessed at the back for the reception of pipe and fittings i/c carriage of material in all leads and lifts.(Hindware/Cera or its equivalents) |
| 59 | Providing and fixing P.V.C connection pipe with bras unions. (a) 30cm length / 45 cm length (I) 15mm Nominal size bore (confirming to BIS Specifications) including carriage of material in all leads & lifts. |
| 60 | Providing and fixing P.V.C waste pipe for sink or wash basin includingP.V.C waste fittings complete. (a) Flexible pipe 32 mm dia |
| 61 | Providing and fixing white vitreous chinasquatting plate urinal with integral rim longitudinal flush pipe i/c carriage of material in all leads and lifts.(Hindware/Cera or its equivalents) |
| 62 | Providing and fixing 8mm dia C.P/S.S jet with flexible tube upto 1 metre long with S.S triangular plate ot European type W.C of quality and make as approved by Engineer-in-charge.confirming BIS specification |
| 63 | Providing and fixing C.P brass toilet paper holder i/c carriage of material in all leads and lifts.confirming BIS specification |
| 64 | Providing and fixing 600X120X5mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P brass brackets and guard rail complete fixed with 40 mm long screws, rawl puls etc. Complete i/c carriage of material in all leads and lifts.confirming BIS specification |
| 65 | Providing and fixing C.P brass bib cock of approved quality confirming to IS:8931 i/c carriage of material in all leads and lifts. .(a) 15 mm nominal bore.ESS ESS/JAQUAR/JAL or equivalent |
| 66 | Providing and fixing C.P brassangle valve for basin mixer and geyser points of approved make confirming to IS:8931 .i/c carriage of material in all leads and lifts.ESS ESS/JAQUAR/JAL or equivalent (a) 15 mm nominal bore. |
| 67 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.Pbrass screws and washers complete. confirming to BIS specifcation including carriage of material in all leads and lifts. |
| 68 | Providing and fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including fixing with approved adhesive etc. Complete i/c carriage of material in all leads and lifts.(Finolex/Superme/Vectus) |
| 69 | 90 mm dia |
| 70 | 110 mm dia |
| 71 | Providing and fixing PVC plain bend ISI marked including fixing with approved adhesive etc. Complete i/c carriage of material in all leads and lifts.(Finolex/Superme/Vectus) |
| 72 | 90 mm dia |
| 73 | 110 mm dia |
| 74 | Providing and fixing PVC single equal branch with oval access door, ISI marked insertion rubber, washer 3 mm thick bolts and nuts complete including fixing eith approved adhesive etc. Complete i/c carriage of material in all leads and lifts.(Finolex/Superme/Vectus) |
| 75 | 90mm dia |
| 76 | 110 mm dia |
| 77 | Providing and fixing PVC floor trap ISI marked or self cleaning design including fixing eith approved adhesive, cost of cutting and making good the wall and floors etc. complete. i/c carriage of material in all leads and lifts.(Finolex/Superme/Vectus) 110X90mm |
| 78 | Providing and fixing 100 mm dia cromium plated stainless steel gratingconfirming to BIS specifcation including carriage of material in all leads and lifts. |