| 1 | Dismentling the existing E.I. work incl existingdefective , non functioning Panels,PBDB, LBDB, Main Switch etc by Co\"s own tools & tackles by maintening normalcy as far as possible as per direction of EIC. |
| 2 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand/ Siemensof the following sizes as to GS.(Normal power- 1 nos, DG power-1 nos )8way Enclosureupto 160 Amp |
| 3 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment ( Legrand / Siemensmake ) as to GS. 8 way Enclosure (for Normal Power & DG Power) |
| 4 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand/ Siemens ) as to GS2+12way Enclosure |
| 5 | Supplying and fixing 415 V four poleMCCB of breaking capacity 25kA/35kA with fixed thermal and fixed magnetic/adjustable thermaland fixed magnetic setting in existing DBs/ enclosure and necessary connection Make-Legrand,/Siemensas to GS. 100 Amp |
| 6 | 125 Amp |
| 7 | Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Legrand / Siemens, as to GS.415 V, 63A FP |
| 8 | 240 V, 40A DP |
| 9 | Supplying and fixing 240/415V,MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand/ Siemens as to GS.6A - 32A SP MCB |
| 10 | 63A TP MCB |
| 11 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded \"FRLS\"PVC insulated & unsheathed copper wire (approved make) partly in 20mm size PVC rigid conduit \"FR\" (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded \"FRLS\"PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar with holes fixed on bakelite/hard rubber insulation over the welded chairs incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65 inspection box, making earthing attachment, painting the MS box and mending goodthe damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed][E-15/5(d)]Average run 6 mtr |
| 12 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FRLS \" PVC insulated & unsheathed copper wire(Finolex/ Havells/KEI / Mescab /Gloster/approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FRLS\" PVC insulated & unsheathed copper wire(Finolex/ Havells/KEI / Mescab /Gloster/approved by EIC)as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box andmending good the damages to original finish On Board |
| 13 | Supply & Fixing 240 V, 2 x 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 200 x 150 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 14 | Supply & Fixing 240 V, 20A, plug socket with separate 20 APiano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150 x 100 x 65mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 15 | Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socketwith separate 2 nos. 6 A & 2 nos. 20A Piano key type switch,indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S &F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 16 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240 x 200 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required ( Computer / Medical Instrument Board ) |
| 17 | Supply and Drawing 1.1 KVsingle core stranded \"FRLS\"PVC insulated & unsheathed copper wire (make-Finolex/Havells/KEI/ Gloster/ Mescab )of following sizes in thick heavy gauge polythene pipe and necy. connection as required incl. cutting channel of (40mmx40mm)/(43mmx43mm)size on masonary wall with S&F heavy gauge 19mm/25mm dia 3mm thick polythene pipe by means of iron hooks and mending good damages to building works 2 x 1.5 sqmm + 1 x 1.5sqmm (forSeparate Plug) |
| 18 | 2 x 2.5 sqmm + 1 x 1.5sqmm (for Power plug ) |
| 19 | 2 x 4 sqmm + 1 x 2.5sqmm (forAC ) |
| 20 | 2 x 6 sqmm + 1 x4 sqmm( from TPN MCB DBto SPN MCB DB s ) |
| 21 | 4 x 6 sqmm + 2 x4 sqmm( for Auto Clave M/C ) |
| 22 | Supplying of following sizes Al. armoured PVC/XLPE(Havells/ Glostar /KEI/Polycab/ approved) as per direction of EIC2core 10 sqmm( for glowsign and Flood Light ) |
| 23 | 4core 35sqmm( from VTPN to MCBPBDB ) |
| 24 | 4 core 95 sqmm( from Panel to VTPN ) |
| 25 | Laying of one No. cable of following sizesin underground trench 460 mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammedAbove 35 sqmm and upto 185 sqmm |
| 26 | Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish |
| 27 | From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. |
| 28 | Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc. |
| 29 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required50 mm dia |
| 30 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry ofXLPE/PVC armoured cables as below : 2core 10 sqmm |
| 31 | 4core 35 sqmm |
| 32 | 4core 95 sqmm |
| 33 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 2core 10 sqmm |
| 34 | 4core 35 sqmm |
| 35 | 4core 95 sqmm |
| 36 | S & D 250 V 50 HZ18\" (450 mm) high flo oscillating type metal body Wall Bracket( Tornedo - 2 )fan operated by pull cord switch with inbuilt regulator ( Make - G/Orient/Approved) |
| 37 | Fixing only cabin fan on wall/ceiling by S&F rag bolts,nuts &washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length |
| 38 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S1.5 sq mm |
| 39 | 2.5 sq mm |
| 40 | 4.0 sq mm |
| 41 | 6.0 sq mm |
| 42 | S&F angular holder(Anchor) on 3\" wooden double round blockincl. S&F 9 Watt LED lamp Philips make.as per direction of EIC |
| 43 | SupplyandFixingofSquarerecessmountedLEDlight(36Watt, 230VAC, 50hZ,6500K NW,THD<10%, bultin2.5KV SPD)withall accessories[Make:PHILIPS,CROMPTON LCTLRNE-36-FO-CDL, BAJAJ, HALONIX, WIPRO, Panasonic, LEGARO, HAVELLES/ Jaquar. |
| 44 | Supplying & Delivery 4 feet single commercial LED typefluorescent light fittings complete with all accessories with 1 x 20 Wt.Master LED Tube lampsimilar to Philips make cat No. TMC-501 P 1xTLED 22 WP3241 corresponding to Wipro / Bajaj / Crompton as per direction of EIC |
| 45 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm ) flexible copper wire of 1.10 mt. length.( including existing fittings) |
| 46 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 47 | Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board |
| 48 | Supply & Delivery 240 V,50 Hz, Metal body Heavy duty Exhaust fan of following sizes and RPM (Make -- EPC/ Calcutta Fans or any approved and recognised brand by EIC) 12\" (30 cm), 1375 RPM |
| 49 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following dia incld. Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)12\" (30 cm), 920 RPM |
| 50 | S/F OLP - 30A A.C Starter suitable with G.I box flushed in wall with voltage check, Amp check, Time check incl. all connection. |
| 51 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S. |
| 52 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. |
| 53 | Supply & Delivery of 240V,50Hz, 16A Analouge Timer having Horizontal Dial Changeover Switch - with 100 h working Reserve-Minimum switching time: 15 minutes fixing on existing Timer DB as per direction of EIC.(Make-Legrand /GEC / Cabtree) |
| 54 | Supply & Delivery 250 V, 50 Hz , AC-3, 40 Amp DP Conctractor with (2 NOor 1 NO + 1 NC Aux. Contract ) fixing on Existing Timer DB ( Make -Legrand / L & T) |
| 55 | S&F Auto clave starter unit of size 16\" x 12\" x 6\" made from heavy gauge CRC sheet metal (16 SWG) with 1no. Front openable hinged type door fixed in wall on flate iron frame. The interconnection should be made by suitable sizes cu wire. The box should be painted by power coated paint & having following accessories:- a) 4 polepower contactor ML3 40 LT make -1 no. b) Add on aux. contact block 2 no. + 2nc (LT make ) - 1 no. c)40 A 4 pole MCB Isolator(Legrand)- 1no d)push bottom switch - 2 nos. e) LED indigator lamp (ESBEE)-3nos. f) 200 A capacity 4 way terminal - 1 no |
| 56 | Supplying and fixingof250 V AC timers fixed on wall withflat iron frame as per directionof EIC and the Box shuldbe comprising with the following accessorise ---i) Double-door SPN MCB Distribution Board with IP-42/43 protection 2+12 way Enclosureas reqd .( Make -Legrand / L & T ) –1 no ii) 230 V , 50 Hz ,16 Amp Single dial 1 x 24 Hrs.Timer ( Microrex QT31 )of quartz driven running reserve Day dial back up by nickle cadmium battery (Make - GEC / Legrand) –1 noiii) 250 V, 50 Hz , AC-3, 40 Amp DP Conctractor with (2 NOor 1 NO + 1 NC Aux. Contract ) ( Make -Legrand / L & T )– 1 noiv) 250 V,50 HZ ,40 Amp, DPMCBIsolator ( Make -Legrand/ L & T)– 1 nov) Auto / Manual By pass Toggle Switcharrangement – 1 no. vi) 250 V ,Diode type neon Indicator lamp ( Make -Legrand/ L & T)– 1 no vii)Bakelite base with FP bolt typestud/ Terminalblock inclS & F Neutral Bar etc with this box for termination of power .viii) The complete arrangement must be wiring by 2.5 Sq mmPVC insulated FRLS Cu wire withsuitablelengthinclsocketing /lugs etc as per requirement &direction ofEIC (Make -Legrand/L & T / Crabtree ) For AC machines |
| 57 | Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For Soft soil |
| 58 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (by ISI-Medium GI pipe as to GS. |
| 59 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall includingproviding drilled holes on the busbar complete with GI bolts,nuts, washers, spacing insulators etc. as required as to GS. |
| 60 | Connecting the equipments to earth busbar including S & F No. 10 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damagesas to GS. |
| 61 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS. |