| 1 | Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS(Brand approve by EIC) |
| 2 | 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) [ 1 (d1) / E- 9 ] |
| 3 | 2x (4 sqmm) + 1 X (2.5 Sq.mm) [ 1 (v) / E- 9 ] |
| 4 | 2x (2.5 sqmm) + 1 X (1.5 Sq.mm) [ 1 (S) / E- 9 ] |
| 5 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc including supplying sockets, tapes. [ 9 / F 5 ] |
| 6 | 10 Sq.mm |
| 7 | 6 Sq.mm |
| 8 | 2.5 Sq.mm |
| 9 | 4 sqmm |
| 10 | Supplying and fixing PVC Rigid Conduit \"FR\" [Precision Make]on wall, ceiling with saddles and other accessories as required and mending good damages to building works.[7 / E 16 ] |
| 11 | 25 mm size |
| 12 | 20 mm size |
| 13 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.( Make - Legrand ) up to 160 A.( Make - Legrand/L&T/HAVELLS ). [ 15 / D- 11 ] |
| 14 | 4 Way |
| 15 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA / 35kA with fixed thermaland fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection..( Make - Legrand/L&T/HAVELLS ). [10 / D-8] |
| 16 | 100 Amp |
| 17 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.( Make - Legrand/L&T/HAVELLS ). [ 7 / D- 6] |
| 18 | 63 A TP |
| 19 | 32 A TP |
| 20 | 16 A SP |
| 21 | Supply & Delivery of4 Core XLPEInsulated & Sheathed Armoured Aluminium Conductor cables [ Make Gloster /Polycab /Havells/Finolx/RR kable/Mascab] NS |
| 22 | 4 Core 35 Sq. mm |
| 23 | Laying of4 CoreXLPEInsulated & Sheathed Armoured Aluminium Conductor cables following size cable on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting. [2b / F- 1 ] |
| 24 | 4 Core 35 Sq. mm |
| 25 | Supplying and fixing compression type gland complete with brass gland,brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below[7(c)/F4 ] |
| 26 | 4Core 35 Sq. mm |
| 27 | Supplying and Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc.[ 8(b) /F5] |
| 28 | 4Core 35 Sq. mm |
| 29 | Supply & Fixing 240 V, 25 A, Modular starter (Brand approved by EIC) on 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [ E-19/20 +E-17/2a] |
| 30 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy.connections with PVC Cu wire and earth continuity wire etc. [5a/E-17] |
| 31 | Supply & Fixing 240 V, 3 Pin 25 A, modular type plug top with indicator as per G.S.[5b/E-17] |
| 32 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (D-9/11) |
| 33 | 2 Way |
| 34 | 4 Way |
| 35 | S & F of 240 Volt, 20 watt 4 ftLED tube light only PC/Aluminium housing ( Make - Crompton /Philips/wipro) on existing batten.NS |
| 36 | S&F of 32Atimer controlled starter DB for 2nos single phase AC in SS double door 16-way DB enclosure (Make:L&T/ Legrand /ABB) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish.All connections should be made by copper wire of 4mm² & 1.5 mm² and finishing with dowells solderless socket by crimping method incl necessary connection & provision for earthing attachment incl Ferruling & marking with S&F following Electrical accessoriesas per direction of EIC:- [NS] (A) 32A DP MCB c curve breaking capacity 10kA (Make:L&T)-- 1no (B) 24Hr x 7days programmable Digital timer (Make:L&T Cat no 67DDT0) -- 1no(C) 22 A 3-pole power contactor (Make:L&T cat no MNX22/240V) -- 2 nos(D) 10A,250V AC ON-OFF-ON SPDT toggle switch (Make-Kaycee Model No:KT1032BY) - 2 nos (E) 230V AC LED indication lamp (Make-L&T) RED COLOUR-- 2 Nos(F) Din rail mounted Terminal Block for Outgoing & Incoming(Make:Elmax Model:KUT4) -- 6 nos(G) 6A SP MCB c curve breaking Capacity 10kA-- 1 no(Make:L&T) |
| 37 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below(For Morrum Soil: ISI-Medium GI pipe) [G-1/2a] |
| 38 | Excavation of soil for installation of Earth Electrode and filling & ramming. (Soft Soil) [G-1/1a] |
| 39 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.[G-2/4a] |
| 40 | Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl.drilling holes, with bolts, nuts, washers etc. [G-2/5d] |
| 41 | Connecting the equipments to earth busbar including S & F 7/14 SWG GI Standard (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.[G-2/5b] |
| 42 | Supply & Delivery of Inverter Split type A.C. machine having Cooling capacity not less than 6900 W, ISSER 3.8 to 4.39, BEE rating not less than 3 star, Noise level not more than 50 db. This Split Air - Conditioning machine fitted withRotary compressors, LCD remote & all other accessories suitable for Refrigerant - R32/R410A. (Make: O-General/ Daikin/Hitachi /Mitsubishi Electric/Mitsubishi Heavy Indistries as per approved by EIC / authority) [NS] |
| 43 | Installation, testing & commissioning of the above said split ACmachine incl supply & Fixing required angle iron structure on wall for placing outdoor unit & mending good the damages as per Direction of EIC. [N.S.] |
| 44 | Supply & Installation of Extra Add-on items -HVAC graded 5/8\"\"( for suction) & 1/4\"\" ( For Discharge) copper refrigerant pipe with 9 mm thick nitrile rubber isulation including sgaddle, Screw, isulation tape, Fastner etc for above AC machine as per direction of EIC. [N.S.] |
| 45 | Supply & laying 1.1 kv grade,3 Core ,4 sqmm flexible copper cable with screw, Saddle,nut bolt etc all necessary items needed for connection.( from starter to AC outdoor connection) ( Make- havells /KEI /Polycab /Finolex as per approved by EIC) [N.S.] |
| 46 | Supply & laying 20 mm dia, PVC Pipe (heavy type) incl. Fitting accessories for water drainage.[N.S.] |
| 47 | Supply & Delivery of R-32/ R-410A Refrigerant.[N.S.] |
| 48 | Add 18% GST (on Item No. 01.00 to 27.00). |
| 49 | Add 1% CESS (on Item No. 01.00 to 27.00). |
| 50 | N.B.: 1) Sl. No. 27.00 is variable depending on the total cost of the actual work on which 18% GST to be calculated during measurment of the work (Item No. 01.00 to 27.00).2) Sl. No. 28.00 is variable depending on the total cost of the actual work on which 1% CESS to be calculated during measurment of the work (Item No. 01.00 to 27.00). |