| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge. All kinds of soil. |
| 2 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth lead upto 50 metres. |
| 3 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 4 | Supplying and stacking at site: (a) 90 mm to 45 mm size stone aggregate. |
| 5 | 63 mm to 45 mm size stone aggregate. |
| 6 | Local Sand @ 25% of Item No. 4a |
| 7 | Stone screening 11.2 mm nominal size (Type B) |
| 8 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . |
| 9 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 11 | DRAINEarth work in excavation |
| 12 | P.C.C. 1:4:8 |
| 13 | B/W in 1:4 Cement Coarse Sand |
| 14 | R.C.C. work |
| 15 | Centering & shuttering |
| 16 | M.S. work in R.C.C. |
| 17 | 12 MM thick plaster (1:3) coarse sand |
| 18 | 12 MM thick plaster (1:3) coarse sand |
| 19 | 12 MM thick plaster (1:3) coarse sand |
| 20 | LANDSCAPINGSupplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment). |
| 21 | Carrigae of sludge upto 5 K.M. |
| 22 | Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured instacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm |
| 23 | Carrigae of manure upto 5 K.M. |
| 24 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. |
| 25 | Spreading of sludge, dump manure or/and good earth in requiredthickness (cost of sludge dump manure or/and good earth to bepaid separately). |
| 26 | Digging holes in ordinary soil and refilling the same with theexcavated earth mixed with manure or sludge in the ratio of 2:1by volume (2 parts of stacked volume of earth after reduction by20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing, including removal of rubbish and surplus earth, if any with all leads and lifts ( cost of manure, sludge or extra good earth if needed to be paid for separately).Holes 0.9 m dia. and 0.90 m deep. |
| 27 | Providing & stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. |
| 28 | Providing & stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35cm as per direction of the officer-in-charge. |
| 29 | Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). With grass Turf. |
| 30 | The provision and installation of a marble bench with precise dimensions of 1500 mm in length, 450 mm in width, and 600 mm in height, complete with detailed carving and ornamentation. The carving and ornamentation must be executed by skilled artisans to ensure intricate and precise details that match the design specifications.Installation includes preparing a suitable foundation, which involves excavation, concrete pouring, and leveling to ensure a stable base. It must be securely fixed to this foundation, with all necessary support structures in place to maintain stability. The marble selected for this bench must be of high quality, suitable for the intended environment, and in accordance with the design and drawing to be approved by the Architect in chargeby the means of shop drawing and sample preparation by the contractor. |
| 31 | Providing and fixing a stainless steel (SS) dustbin with dimensions of 487 mm (width), 399 mm (depth), and 1138 mm (height). The dustbin must be constructed from high-grade stainless steel with a polished finish to ensure durability and corrosion resistance. The foundation preparation will include excavation to the required depth, pouring a level concrete base, and securely fixing the dustbin using a sturdy base plate to ensure stability and prevent tipping.The dustbin will be clad with 75 mm thick marble on all sides, in accordance with the design specifications. The marble must be of high quality, free from defects, and suitable for the intended environment. All edges and joints will be smoothly finished and aligned, with the appropriate adhesive used for secure attachment. The installation must ensure proper leveling, alignment, and secure fixing to the foundation to guarantee stability and tamper resistance. After installation, all surfaces will be cleaned, and a f conducted by the Engineer/Architect to ensure compliance, design and drawing to be approved by the Architect in chargeby the means of shop drawing and sample preparation by the contractor. |
| 32 | Water Cooler with inbuilt RO+UV with water storage capacity of 80 ltr., cooling capacityof 60 ltrs, No. of faucets -02 no. of stage for filter cum purifier-7, Material-SS, Type of installation-Indoor, weight 85 Kg, warrenty-12 Months Aquaguard or Equivalent |
| 33 | COST OF PLASTER WORK ON WALLS |
| 34 | COST OF PAINT ON WALLS |
| 35 | Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitablestrength with following components complete as required:-a) Solar Photovoltaic Module of capacity 540 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversionefficiencyshallnotbelessthan23%.PVmodulesusedinsolarpowerplants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 05 years and 80% at the end of 25 years.b)PowerConditioningUnit(PCU)of350-800VDCInputvoltagerangeand400VAC,three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 99%, total harmonic distortion less than 1% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d)FixingofArrayjunctionbox&MainjunctionboxwithIP65protectionandtermination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f)Connections&Interconnectionsbysupplying&fixingrequiredsizeXLPEinsulatedcopper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.System capacity 40KW Solar Modules High-efficiency panel (>540 Wp, or 23% efficiency or more ) Inverter High-efficiency Inverter ( 99% ) Estimated System Output Approx 56,000.00 KWh annually Solar PV Modules 74 x High-Efficiency 540 Wp ModulesInverter: 1 x 40 kW On-Grid Inverter (99% efficiency)Cabling: High-quality DC and AC cables Installation & Commissioning Included Structural & Electrical ComponentsIncluded 40 KWP Installation & Commissioning Included |
| 36 | Carving Granite Work in Sandstone including Providing & fixing with Engraving 30 mm thick Sandstone |
| 37 | Proviidng and fixing of Stone Murals |
| 38 | ZIVA FLUSH DOWN LIGHT polycarbonate opal concave diffuserr Mounting Type Recessed 18 Watt CCT 5700 K dimension 155MMX34MM CUT OUT 90MMwith Code IVAFLRDDLR18WLED857S Make Havells,Philips or Equivalent |
| 39 | LUMILINE PLUS PRO BATTEN LIGHT polycarbonate diffuser Mounting Type on Wal CCT6500 K 10 Watt dimension 550MMX23MMX33MM ILUMILINEPLUSPROBS10WLED865SPCSSINDMake Havells, Philips or Equivalent |
| 40 | BOLLARD LIGHT 34 Watt Bamboo Led bollard/ CS JUNCTION BOX 3 WAY Make Havells,Philips or Equivalent |