| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingthe excavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingas directed,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 3.00 m.) By Manual Means Bd.A.1 Page Number 259 |
| 2 | Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterialupto distanceof 50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthe bedforthefoundationandnecessarybackfilling,ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Manual Means |
| 3 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/quartzite/ gneiss metal for foundation and bedding including bailing out water, Steelcentering,formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredand curingcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Typemixer/concreteBatchmixplant(Panmixer)etc.complete. Withfineaggregate(CrushedsandVSI Grade) Bd. E. 1 Page Number 287 |
| 4 | Providing and laying in situ /Ready Mixcement concreteM-20of trap / granite /quartzite/ gneiss metalfor R.C.C.work infoundationslikeraft,stripfoundations,grillageand footingsofR.C.C.columnsand steel stanchionsetc. including bailing out water,Steelcentering formwork, laying/pumping cover blocks, compaction and curingrougheningthesurfaceifspecialfinishistobeprovided(Excluding reinforcementandstructuralsteel)etc.complete,withfullyautomaticmicroprocessorbasedPLCwith SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Bd.F.3 Page Number 298 and B.7, Page Number38 |
| 5 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering,formwork,coverblocks,laying/pumping,compactionfinishing the formedsurfaceswithcement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumTypemixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Bd.F.5 Page Number 300 and B.7, Page.Number 38 |
| 6 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20 oftrap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirected including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening thesurfaceifspecialfinishistobeprovidedand curingetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade) Bd.F.6 Page Number 300 and B.7, Page Number38 |
| 7 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/ quartzite/ gneiss metalforR.C.C. slabsand landings as perdetailed designsand drawingsincludingsteelcentering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic microprocessorbasedPLCwithSCADAenabledreversibleDrum Typemixer/concreteBatchmixplant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Bd.F.8 Page Number 302 and B.7, Page Number38 |
| 8 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.chajjaasperdetaileddesignanddrawingsincludingsteelcentering,formwork,coverblocks, laying/pumping,compactingand rougheningthesurfaceif specialfinishistobeprovidedandcuring complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLC with SCADAenabled reversible DrumType mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade) Bd.F.9 Page Number 303 and B.7, Page Number38 |
| 9 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels,chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings andschedules.including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Bd.F.17, Page Number 306 |
| 10 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar 1:6 infoundationsandplinthofinnerwalls/inplinthexternalwallsincludingbailingoutwatermanually, striking joints on unexposedfaces, raking out joints on exposedfaces and watering etc. Complete. Bd.G. 1 Page Number 313 |
| 11 | Fillinginplinthandfloorswithcontractors material/broughtfromoutsideandapprovedbyEngineer incharge inlayersof15cm to20cmincludingwateringandcompactionetc. complete. Bd.A.11 Page Number 263 |
| 12 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6 insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. Complete Bd.G.5 Page Number 315 |
| 13 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop ironstrips25mm X1.6mm placed ateverythirdcourse,properlybentandbondedatendsscaffolding, racking out joints and watering etc. complete. Bd.G.7 Page Number 316 |
| 14 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:5without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. |
| 15 | Providing internal cement plaster 20mm thick inSingle coats in cement mortar 1:5without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete Bd.L.4 Page Number 368 |
| 16 | Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness andconfirming to IS. 15622-2006( groupBla) of approved make, shade and pattern for flooring in required position laid on a bed of1:4cementmortarincludingneat cementfloat,fillingjoints,curingandclearing etc. complete. |
| 17 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and patternfordadoandskirting inrequiredpositionfixedin1:4cementmortarincludingneatcementfloat, filling joints, curing and clearingetc. complete Bd.M. 12 Page Number385 |
| 18 | Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (groupDII-A)and7to8mm thickforflooring inrequiredpositionlaidonabedof1:4cementmortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. Bd.M.12 Page Number 385. |
| 19 | Providingandlayingceramictilesof havingsize30cm.x30cm.andconfirmingto corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Bd.M.13 Page Number 386. |
| 20 | Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. As directed by Engineer in charge. |
| 21 | Providing andfixing frame with/without ventilatorof size as specifiedwithCountrynon teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. As directed by Engineer in charge. |
| 22 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldingsandlipping,wroughtironholdfasts,chromiumplated fixtures and fastenings, with brass mortiselock,chromiumplatedhandlesonboth sides, and finishing with French Polish etc. complete. |
| 23 | Providing and fixing steel window C.R.C. sheet as per I.S. 1513 : 1986. gauge sect. 65 x 40 x 25 mm shutter single sheet of 24 gauge single leaf joinedby fusion welding at appropriate points with vertical grooves of 15 mm wide and 15 mm deep at a distance of 45 mm. The first andlastribshouldbe60mmawayfrom verticaledgeoftheshutter.theshuttershallbe welded, with angle to from the periphery of the shutter. At the center of the frame there shall beangleweldedtobifurcatetheframeintosegmentswithtwoleaf shuttersquare12mm square guard bars at 120 mm center with all accessories As directed by Engineer in charge. |
| 24 | Providingandfixingsteelventilatorfullyglazedpartlyfixedasperdetaileddrawingwithhotdip zinc coatingincludingfabricatingglazingwith plain /obscured glasspans 5mmthickandapprovedtype quality and iron oxidized fixtures and fastening with guard square bars 12 mm 10 cm c/c and oil painting 2 coats etc. complete. BD-T-53Page Number 509 As directed by Engineer in charge. |
| 25 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plasteredsurfaces includingscaffoldingifnecessary,preparingthesurfacebythoroughlycleaningoil,grease,dirtandother foreign matter and sand papering as required etc. complete. As directed by Engineer in charge. |
| 26 | Providingandapplyingwashableoil-bounddistemperofapproved colourand shadetooldand new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. Bd.P.5 Page Number 413 |
| 27 | Providingandapplyingtwocoatsofwaterproofcementpaintofapprovedmanufactureandof approved colourtotheplasteredsurfacesincludingscaffoldingifnecessary,cleaningandpreparingthesurface, watering for two days etc.complete. Bd.0.8 Page Number 406 |
| 28 | Providing and applying two coats of lead/zinc base oil paint/ bituminious paint of approved colourtonew structural steel work and iron work in buildings including scaffolding ifnecessary,cleaningand preparing the surface etc.complete. (excluding primer coat). Bd.0.3 Page Number 404 |
| 29 | ProvidingandfixingOrissatypewhiteglazedearthenware575mmwaterclosetpan including S trap withearthenware footrests,castironsoilandventpipe uptooutside face ofthe wall 1:2:4brick batlime concrete bedding without flushing tank and its accessories etc. complete. As directed by Engineer in charge. |
| 30 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and withnecessary fixtures andfitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. As directed by Engineer in charge. |
| 31 | ProvidingandfixingwhiteglazedearthenwareWashHandBasinof55cm.x40cm.size including coldwaterpillartap/coldandhotwaterpillartapbrackets,rubberplugsandbrasschain,stoptapand necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. Bd.V.30 Page Number 565 |
| 32 | Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and builtcorrugatedinclusiveofdeliveryuptodestinationhoistingand fixing of accessories such as inlet,outletoverflowpipeinclusiveofalltankscapacity between 200 to 1000 liters As directed by engineer-in- charge. |
| 33 | Providing and fixing on walls / celling/floor 20 mm dia UPVC pipe with necessary fitting remaking good the demolished portion etc |
| 34 | Providingandfixing15mm dia.screwdownbib/stoptapofbrassincluding necessarysocketunionnut complete. |
| 35 | Providing 25 mm to 30 mm thick partition of polished black kadappa stone slab of approved quality including giving required size and shape etc. Fixing in cement mortar 1:3 curing and cement etc. complete. a) One side polish Bd.M.35 B/P Number393 |
| 36 | Providingsoakpitofsize 120cm x120cm x120cmincluding excavatingandfilling with brick-bats. Bd.V.46, Page Number 576 |
| 37 | ROYALTY CHARGES :- Supply of Rubble, Murum, Soil, 60mm./40mm. metal (Hand broken), royalty charges are not included in the rates.[As per Govt. of Maharashtra, Revenue and Forest Departments Gazette No.146 Dt.04 June ,2021. States that the royalty charges ofRs.211.95/Cu.M. ) are considered. The surcharge levied on Royalty shall also be payable to the contractor. +2 % SurchargeROYALTY CHARGES FOR OTHER MINERALS |
| 38 | Laboratory testing charges are not considered in the Rate Abstracts. Where ever required separate item shall be taken in the estimate for material testing charges, on the basis of testing frequency and charges fixed by Vigilance & Quality Control Circle, for the current year and shall form part of tender.testing of material by Quality control and certified quality must be use by contractor. CONCRETE Compressive Strength of C. C. Cube (Set of 3 Cubes) |
| 39 | Compressive Strength of Bricks |
| 40 | PART II- ADD 18% GST |
| 41 | 0.50% FOR LABOUR INSURANCE |