| 1 | Repair & maintenance of Fisheries officeroffice building at Fish Farm Alsu Distt . Mandi (H.P.) SH:-Re-wiring and electrical installationthere in ) |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copperconductor single core cable etc as required.(a) Group-C as directed by engineer in charge |
| 3 | Supplying and fixing G.I. Modular box 3 Module with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connections etc. as required. |
| 4 | Supplying and fixing G.I. Modular box ofsize 3 Module with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required. |
| 5 | Supplying and fixing following rating Modular switch /socket/Bell Push on the existing switch box / cover including connections etc. as required. (Make: Legrand(Myrius),L&T(entice),Anchor(Roma Plus). 5 amp switch |
| 6 | Supplying and fixing following rating Modular switch /socket/Bell Push on the existing switch box / cover including connections etc. as required. (Make: Legrand(Myrius),L&T(entice),Anchor(Roma Plus).5amp Socket |
| 7 | Supplying and fixing following rating Modular switch /socket/Bell Push on the existing switch box / cover including connections etc. as required. (Make:-Legrand(Myrius),L&T(entice),Anchor(Roma Plus). Bell Push Modular |
| 8 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 2x1.5 Sq. mm + 1X1.5 sq.mm |
| 9 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 2x4 Sq. mm + 1X4 sq.mm |
| 10 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 4x4 Sq. mm.+ 2X4 sq.mm |
| 11 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 2x10Sq. mm.+ 1X6 sq.mm |
| 12 | Providing, installationtesting and commissioning of ceiling fan with regulator including wiring the down rods of standard length (up to 30cm) and 16/0.20mm twin twisted flexiblecotten braided copper cable including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc as required including carriage of material within all leads and lifts. ( Usha technics,Crompten,Havells H S Velocity make or its equivalent. ) or as approved by the Engineer-in-Charge.1200 mm sweep |
| 13 | Providing and installation exhaust fan of300mm (Metal body) size in the existing opening,including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:Make:- Usha,Bajaj,Crompton or its equivalent as approved by Er-in-charge |
| 14 | Supplying and Fixing LED Battan 36 watt High quility aluminium extruded with decorative end caps of superior quality ( Wipro Make ) as per item code LL22-511-XXX-65-G1 as required. Complete in all respect and as approved by the Engineer-in -Charge.Make-Wipro,Jaquar,Philips or its equivalent. |
| 15 | Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:- |
| 16 | Supplying and fixing bakelite batten/angle holder including connections etc. as required:- |
| 17 | Supplying and fixing 5 amps to 32 amps , 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.)Make L&T, Hager,ABB or its equivalent as per best satisfaction of Engineer-in -charge. Single pole |
| 18 | Supplyinganderection of 40/50/63 amps, 10 KA breaking capacity, 240volts, \"C\" curves, miniaturecircuit breaker of pole Double pole in the existing MCB DB complete with connections etc. as required:-Make L&T, Hager,ABBor its equivalent as approved by Engineer-in -charge. |
| 19 | Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required( a) Double door 12 way as directed by engineer in charge |
| 20 | Providing and installationof LED Street light 30W with bracket power coated pressure die cast aluminium high power led with heat resistant toughened glass with lens ,electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. as required.:Make ,wipro(LR26-371-XXX-65-XX),Panasonioc Philips or its equivalent as approved by Engineer-in -charge.( Five year warranty) |
| 21 | Supplying and fixing electrical switch board, having 3 No. of 5 amp. switches and socket on suitable size of metal box of12 modules on surface or in recess with suitable size phenolic laminated sheet cover in the front i/c providing and fixing3 No. 5 pin 5/6 amp socket outlet and 5/6 ampmodulartype switch, connection, painting etc.as req.(For Computer board) |
| 22 | Supplying and fixingtrue power make advanced earthing system havingcopper pipe 2 meter long 50 mm dia with terminal size 50x6 mm,internal strip size 25x3 with 25 Kg compound including exvation of pit and refiling the same and making earthing pit cover 13 inch dia as required complete in all respect. make :-True power,Earth plus,Ashloka or its equivalent as per best satisfaction of Engineer-in -charge. |
| 23 | Providing and laying earth connections from earth electrode with 6 SWG (4 mm dia.) G.I. wire on surface or in recess for loop earthing etc. as required. |