| 1 | Part A: Civil works |
| 2 | Earth work in hard soil or gravelly soil within 50m intial lead & 1.50 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and including cost ofall labour, T & P, sundries and labour cess etc complete and as per the direction of Engineer-in-charge. |
| 3 | Fillingfoundation& plinthwith sand, well watered & rammed including cost,conveyance, royalty, T&P, sundries, lead, lift, delift and labour cessetccomplete and as per the direction of Engineer-in-charge. |
| 4 | Dismantling and removing 2.5cm. thick artificial stone flooring including stacking the useful materials for reuse and removing the debries within 50mtr leadincluding all labour, T&P, sundries and labour cess etc completeingroundfloorandfirstfloor and as per the direction of Engineer-in-charge. |
| 5 | Removing old lime or cement plaster from walls including racking out joints 12mm. deep and removing the debries within 50mtr leadincluding all labour, T & P, sundries,lead, lift, delift and labour cess etc complete in ground floor &1st floor and as per the direction of Engineer-in-charge. |
| 6 | Dismantling and removing doors & windows and ventilators including removal of frames,hinges, fastenings and stacking the same for reuse & removing the debries within 50m lead including all labour, T&P, sundries & labour cess etc completein ground floor & 1st floor and as per the direction of Engineer-in-charge. |
| 7 | Dismantling brick or stone masonry in lime or cement mortar under 3mtr. height including stacking the usefulmaterials for reuse and removing the debries within 50mtr lead includingall labour,T & P, sundries,lead, lift, delift and labour cess etccompleteingroundfloor&1stfloor and as per the direction of Engineer-in-charge. |
| 8 | Dismantling and removing all RCC chajja, shelves, fins & parapet including stacking the useful materials for reuse and removing the debris with 50m initial lead including all cost of labour, T&P, sundries, & labour cess etc complete and as per the direction of Engineer-in-charge. |
| 9 | Scraping old paint with scapers,sand papering& washing with soap water or soda including scaffolding uptoanyheight including allcost of labour, T&P, sundries,scaffolding&labour cess etc complete and as per the direction of Engineer-in-charge. |
| 10 | Close deep chipping and cleaning to R.C.C. surface for receiving cement plaster or cement concrete including all labour, T&P, sundries and labour cess etc completeingroundfloor&1stfloor and as per the direction of Engineer-in-charge. |
| 11 | Cement concrete (1:3:6) with 40mmsize HGCB metal including cost, conveyance, royalty,lead, lift, delift, all labour, T&P, sundries, labour cess and curing etc complete and as per the direction of Engineer-in-charge. |
| 12 | Providing M.S grills approximately35.28Kg /sqmmadeoutofM.Sangleframeofcrosssection40mm x 40mm x 5mm,3verticalmembers& 2horizontalmembers, 4 nosoffixingclampsof0.20 mtr longeach ofsameanglesection,12 numbersof 12sqmm MSbarsof1.50mtrlong eachashorizontal barsand14numbersof12 sqmm MSbarsasvertical members @ 1.20mtrlong each, primingtheMSgrill withredoxideprimerandpaintingtwocoatswithanyapprovedenamelpaint&fixingthesamein position withcementconcrete(1:2:4)with12mm HGCB chipsfor4nosofclampgroovesetccomplete including allcostof materials,labour,T & P,sundries,fabricationcharges, fixingcharges&labourcessetccomplete and as per the direction of Engineer-in-charge. |
| 13 | Cement concrete (1:2:4)for R.C.C works with 12mm size HGCB chips including cost, conveyance , royalty, all labour, T&P , sundries, lead, lift, delift, labour cess and curing etc completeingroundfloor&1stfloor and as per the direction of Engineer-in-charge. |
| 14 | Providing & fixingWoodplasticComposite section4\" x 2.50\" x 210\" workframed and fixed( wrought & putup) in trusses , purlins, frames of doors& windows, ventilators, beamsand fixed the same in position with six numbers of10 mmdia x 140 mmlong screwedsteelboltwithPVC plugofsamelengthincludingdrilling10 mmdiaholeindoor /windowchaukathsincluding all cost ofallrequiredmaterials , labour, T&P , sundries, labour cess and curing etc complete and as per the direction of Engineer-in-charge. |
| 15 | Providing,fittingandfixinginposition32 mmthicksingleleaved / Doubleleavedwudfrill pine doorshutter includingcostofdoorshutter,allhardware fittings likeone numbersofwoodenhingedcleat, Twonumbersof ISIchromiumplatedhandles 125 mm x 175mm x 32 mm, Two numbrerISI chromiumplated towerbolts200mmx10 mm, four numbersofS.SRigma butthinges125 mm x 75 mm x 2.6mm, One numbers ofdoorsetHLAMAAGMBN ,one numberofdoorstopperandalltypesofrequiredscrewsetccompleteincludingalllabour, T & P, sundries, labour cessetccomplete and as per the direction of Engineer-in-charge. |
| 16 | Providing and fixing factory made uPVC white colour casement / sliding /overhung window shutters made of extruded profiles of frames and sash will be mitered cut and fusion welded at all corners including drilling of holes for fixing hard wares and drainage of waters etc making arrangement for fixing hardwares EPDM gasket 1.2+/- 0.2mm thick galvanized steel profile to be inserted in required profile frame will be fixed to the wall with 8x100 mm long fasteners all complete as per direction of Engineer in charge (rates including of all rates including hardware fittings glazing complete as per direction of Engineer in charge of approved brand and design (Fenesta/ LG hyusen/equivalent) Sliding wind or with two/three track (2/4 shutter) sliding frame 67/52mm with sliding glazing bead 35mmx18mm with sliding interlock for window (one vertical in each shutter 45.5x28mm with 5mm glass of approved quality and with touch lock , steel roller 8 nos, crescent lock 2 nos (white powder coated ) all complete and as per the direction of Engineer-in-charge. |
| 17 | Rigid and smooth centering and shuttering for RCC works including false work and dismantling them after casting including cost ofallmaterials complete including all labour, T&P, sundries, lead,lift,delift andlabourcess etc complete and as per the direction of Engineer-in-charge. |
| 18 | RCC foundation, plinth bandand footing bases of cloumns , mass concrete and precast RCC slab etc |
| 19 | Cement concrete (1:2:4)for P.C.C works with 12mm size HGCB chips including cost, conveyance , royalty, all labour, T&P , sundries, lead, lift, delift, labour cess and curing etc completeingroundfloor&1stfloor and as per the direction of Engineer-in-charge. |
| 20 | Supplying, fitting and placing uncoated HYSD bar TATA Tiscon Fe-500D/ SAILISI bar Reinforcement complete as per drawing and technical specification including cost, conveyance ,all labour, T&P , sundries, labour cessetc completeingroundfloor and as per the direction of Engineer-in-charge.. |
| 21 | Brick work with fly ash brick23cmx11cm x8cm size having crushing strengthnot less than 75kg/sqcm with dimensional tolerance ±2% in cement mortar (1:6)in foundation & plinth and superstructureincludingcost,conveyance, royalties, all labour,T & P, sundries, labour cess and curing etc complete in ground floor and first floor and as per the direction of Engineer-in-charge. |
| 22 | 16mm thick cement plaster in cement mortar (1:6)including admixure of Dr. Fixit pidi proof (LW+) over brick or stone masonryincludingcost, conveyance,royalty, lead, lift, delift,alllabour, T&P, sundries, labour cess andcuringetc completeingroundfloorand1stfloor and as per the direction of Engineer-in-charge. |
| 23 | 12mm thick cement plaster (1:4) to R.C.C. roof andchajjaetcincluding admixure of Dr. Fixit pidi proof (LW+) including cost, conveyance, royalty, all labour, T&P, sundries, labour cess and curing etc complete and as per the direction of Engineer-in-charge. |
| 24 | Providing and fixing 20mm thick granite tiles in floors, treadsor stepsandlandingusing approved shade , quality, and size of granite slabatall heighton 25mm thick bed of cement mortar of mix (1:4)jointedwithneatcementslurry mixedwithpigmenttomatchtheshadesofthetilesincludingrubbingandpolishingcompleteincluding cost of granitetile, conveyance,royalty,alllabour ,T&P,sundries, laoding, unloading, stacking of materialsatsite ,curing andlabourcessetccomplete and as per the direction of Engineer-in-charge. |
| 25 | Providing and fixing vitrified tile flooring using double charged fully vitrified tiles of premium grade having thickness of 8cm to 10cm confirming to ISI-13756 Of 600mm*600mm coloured / printed series (homogeneous) of approved quality, Johnson /Kajaria/Rak/ Somany or equivalent in all floors & dados of all heights on 20mm thick bed of cement mortar of mix(1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required qualities of pigment of approved mark to match the shades of vitrified tile if required watering and curing for 21 days including cost ofall material , labour T&P, sundries,lead,liftdelift& labour cess etc complete in groundfloor &firstfloor and as per the direction of Engineer-in-charge. |
| 26 | Providing andfixing30cm x 30cm / 40cm x 40cmspecialplain / printedseriesceramic antiskid floor tilesofpremiumgradehavingthickness7mmto8mmconfirmingtoIS 13755infloors, treadsorstepsandlandingson 25 mmthickbed ofcementmortar(1:4)jointedwithneatcementslurrymixedwithpigmenttomatchtheshadesofthetilesincludingrubbingandpolishingcompleteincludingcost oftiles, alllabour,T & P, sundries, allothermaterials,conveyance, royalty,lead,lift, delift, labour cessandcuringetccomplete ingroundfloorand1stfloor and as per the direction of Engineer-in-charge. |
| 27 | Providing andfixing20cm x 30cm / 20cm x 20cmspecialplain / printedseriesceramicwalltilesofpremiumgradehavingthickness6.5mmto6.7mmconfirmingtoIS 13753 indadosskirting andrisersofstepson12 mmthickcementplaster(1:3)jointedwithneatcementslurry mixedwithpigmentstomatchtheshadeofthetilesincludingrubbingandpolishingcompleteincludingcost, conveyance, royalty, alllabour, T & P, sundries,lead,lift, delift, labour cessandcuringetccomplete ingroundfloorand1stfloor and as per the direction of Engineer-in-charge. |
| 28 | Providing,fittingandfixinginposition25 mmthicksingleleavedWPC doorshutter includingcostofdoorshutter,allhardware fittings likeone numbersofwoodenhingedcleat, Twonumbersof ISIchromiumplatedhandles 125 mm x 175mm x 32 mm, Two numbrerISI chromiumplated towerbolts200mmx10 mm, three numbersofbutthinges100 mm x 70 mm x 2.60mm, Two numbers ofchromiumplatedslidingdoorbolt (Aldrop). 250 mmx 12 mm,one numberofdoorstopperandalltypesofrequiredscrewsetccompleteincludingalllabour, T & P, sundries, labour cessetccomplete and as per the direction of Engineer-in-charge. |
| 29 | Providing and finishing wall surfacewithBirlawhitewallsealwaterproofingputtyofAsian/ Berger/ Shalimar make and finished smooth and even surface to receive painting including cost of paint,scaffolding charges, labour , T & P, sundries,labour cess etc complete ingroundfloor& 1stfloor and as per the direction of Engineer-in-charge. |
| 30 | Wall painting two coats withplastic emulsion paint of approved shade of Berger/ Asian/ Shalimar / Nerolac / Dulux orequivalent make on old work to give an even shade atallheight includingcost of paint, brush, putty,all labour, T&P, scaffolding, sudries, labour cess etc complete in ground floor and first floor and as per the direction of Engineer-in-charge. |
| 31 | Paintingtwo coats to outside wallssurfacewithexteriorweathercoat paint ofapprovedshadeofAsian/Berger/Shalimar / Nerolac / Duluxoranyequivalent make onnew work to give an even shade atallheightincluding cost ofweathercoatpaint, brush, putty, all labour, T&P, sundries,scaffolding and labour cess etc complete in ground floor and first floor and as per the direction of Engineer-in-charge. |
| 32 | Providing, fitting &fixingof 80 mmthickcementconcrete paverblockinfloorsofapprovedmakelaidon20 mmthickcementmortar(1:4) (1 cement :4 coarsesand)and fillingthejointswithsandincludingcost ofallmaterials, conveyance, royalty, alllabour,T & P, sundries, lead, lift, delift, labourcessandcuringetccomplete and as per the direction of Engineer-in-charge. |
| 33 | Priming one coat with red oxide primer including cost of primer, brush, all labour, T&P, sundries, labour cess etc complete in ground floor and as per the direction of Engineer-in-charge. |
| 34 | Painting two coats to doors & windows with any approved enamel paintofAsian/ Berger/Shalimar/Nerolacmake including cost of paint, brush, all labour, T&P, sundries, labour cess etc complete in ground floor and first floor as per the direction of Engineer-in-charge. |
| 35 | P.H. Works |
| 36 | Dismantlingsquattingtypewaterclosetandurinalplatesandmendinggoodthedamagestothefloorincludingalllabour, T & P, sundriesandlabourcessetccompletein groundfloor&firstfloor and as per the direction of Engineer-in-charge. |
| 37 | Providing&fixing 20\" x 16\" (500 x 400) mmporcelain washhandbasinwithapairofC.IbracketincludingcuttingwallsandmakinggoodthedamagesinC.C (1:2:4) asperspecificationallcompleteincludingcostofallmaterials,labour,T & P, sundries,curingandlabourcessetccompleteingroundfloorand1stfloor and as per the direction of Engineer-in-charge. |
| 38 | Porcelain20\" x 16\" ( 500 x 400) mm WashHandBasin. |
| 39 | Providing and fixing 600mm x 450 mm bevelled edge mirror of superior glass / Belgium fixed to wooden plugs with chromium plated brass screws and washers complete including all costofmaterials, labour, T&P sundries & labour cess etc complete and as per the direction of Engineer-in-charge. |
| 40 | Providing and fixingstandardsized ChromiumPlatedtowelrailcompletewithChromiumPlatedbrassbracketsfixedtowoodenplugswithChromiumPlatedbrassscrewscomplete as per specifications,including all cost ofmaterials,labour, T&P sundries & labour cess etc complete and as per the direction of Engineer-in-charge. |
| 41 | Providing and fixingwashdown watercloset ( EuropeantypeW.CpanHindware make )withintegral\"S\"or \"P\"trap confirmimgtoIS2556 : Part8 - 2004, tothefloorwithwoodenplugandchromiumplatedscrewsincludingjointing thetrapwithsoilpipeincementmortar ( 1:1) etcallcompleteincluding all cost of materials, labour, T&P,sundries & labour cess etc complete and as per the direction of Engineer-in-charge. |
| 42 | Whitevitreouschina washdown watercloset (EWC) |
| 43 | Providingandfixingplasticseat&coverHindwaremake forwashdownwaterclosetwithchromiumplated brasshingesandrubberbuffersallcomplete including all cost of materials, labour, T&P,sundries & labour cess etc complete and as per the direction of Engineer-in-charge. |
| 44 | Providing&fixing PVClowlevelflushingcistern ofHindwaremakewith manuallycontrolleddevice(handle&lever)withallfittingsandfixtures including cost, conveyance all labour, T&P,sundries, lead, lift, delift,labour cess etc complete and as per the direction of Engineer-in-charge. |
| 45 | Providing&fixingsteelkitchensink singlebowlMousumisize 24\" x 18\" x 10\"includingcuttingholesinwalls,granitetileandmakinggoodthedamagesetcallcompleteincluding costofa goodqualitychromiumplatedsinkfaucet, angularstopcockand15mmdiaPVCconnectingpipe,conveyance all labour, T&P,sundries, lead, lift, delift,labour cess etc completeasperspecification and as per the direction of Engineer-in-charge. |
| 46 | Providing&fixing 32 mmdiaPVCwastepipe forwashbasinorsinkwithbrasschecknut includingcost,conveyance, all labour, T&P,sundries, lead, lift, delift,labour cess etc complete and as per the direction of Engineer-in-charge. |
| 47 | Providing&fixing 15 mmdia pillartapscapstanheadscrewdownhigh pressurelettered\"Hot\"and\"Cold\"withlongscrews,shanksandbacknutsincludingcost,conveyance, all labour, T&P,sundries, lead, lift, delift,labour cess etc complete and as per the direction of Engineer-in-charge. |
| 48 | Providing&fixing 15 mmdia PVCinletconnectionpipe andmakingconnectionwithpillarcocks/ sinkfaucetsandsupplymains forwashhandbasin/ kitchensinketccomplete includingcost,conveyance, all labour, T&P,sundries, lead, lift, delift,labour cess etc complete and as per the direction of Engineer-in-charge. |
| 49 | Providing&fixing 100 mmdia chromiumplatedshowerwith15 mmor20 mminletincluding costofshower arm15 mm x 225 mmwithflangeround ,conveyance, all labour, T&P,sundries, lead, lift, delift,labour cess etc complete and as per the direction of Engineer-in-charge. |
| 50 | Providing and fixing standard sized glass shelf with chromium plated brass bracket and guard rail complete fixed to wooden plugs with chromium plated brass screws including cost of material , labour T&P, sundries, & labour cess etc complete and as per the direction of Engineer-in-charge. |
| 51 | Providing&fixing 100 mmdiaC.P grating infloorincludingcost,conveyance, all labour, T&P,sundries, lead, lift, delift,labour cess etc complete and as per the direction of Engineer-in-charge. |
| 52 | Providing&fixing 15 mmdia C. Plongbodybibcockincludingcost,conveyance, all labour, T&P,sundries,labour cess etc complete and as per the direction of Engineer-in-charge. |
| 53 | Providing&fixing 15 mmdia C. Plongbodytwowaybibcockincludingcost,conveyance, all labour, T&P,sundries,labour cess etc complete and as per the direction of Engineer-in-charge. |
| 54 | Providing&fixing pvchealthfaucetwith 1.00 mtrtubewithhookincludingcost,conveyance, all labour, T&P,sundries,labour cess etc complete and as per the direction of Engineer-in-charge. |
| 55 | Providing&fixing 15 mmdia C. Pangularstop cockincludingcost,conveyance, all labour, T&P,sundries,labour cess etc complete and as per the direction of Engineer-in-charge. |
| 56 | Providing&fixingC. Psoapholder / discincluding cost,conveyance, all labour, T&P,sundries,labour cess etc complete and as per the direction of Engineer-in-charge. |
| 57 | Providing&fixinggoodquality toothbrushholderincludingcost,conveyance, all labour, T&P,sundries,labour cess etc complete and as per the direction of Engineer-in-charge. |
| 58 | DismantlingG.Ipipesincludingstackingofpipes within50 mtrleadincluding all labour, T&P,sundries,labour cess etc complete and as per the direction of Engineer-in-charge. |
| 59 | Providing&fixingtowallorceilingandfloorUPVCpipes classconfirmingto ASTM-D- 1585/89 (Sch-80)and pipefittingsof thefollowingnominalborewithclampsincludingmakinggoodthewalls,ceilingandfloorallcomplete includesjointingofpipes& fittingswith UPVCsolventcementandtestingofjointscompleteincludingcost, conveyance, all labour, T&P,sundries, lead, lift, delift,labour cess etc completeasperspecification and as per the direction of Engineer-in-charge. |
| 60 | 20 mmdiaUPVC pipes. |
| 61 | 25 mm diaUPVC pipes. |
| 62 | Providingandfixingof25mmdiaUPVCballvalve Schedule - 80Ashirbadorequivalentwithtwonosofunions includingcostofallmaterials,alllabour, T 8 P,sundriesandlabourcess, testing etccompleteingroundfloorand1stfloor and as per the direction of Engineer-in-charge. |
| 63 | Detailsofcostfor onenoof25 mmUPVCballvalve. |
| 64 | Detailsofcostfor onenoof20 mm dia UPVCballvalve. |
| 65 | Providingandfixing onwall face 110mmdiaunplasticisedrigidUPVCpipe (4 Kg / sqcm) ventilationandrainwaterpipesofFinolex / Ashirbad / OriplastconfirmingtoIS : 14735type\"A\"includingjointingwithsolventcementsinglesocketedpipesforventilation& rainwatersystem includingallcostoflabour, T & P, sundries,PVCclamp,nail,scaffoldingandlabourcessetccomplete and as per the direction of Engineer-in-charge. |
| 66 | Cuttingholes throughthebrickor lateritemasonrywall fortaking80 mm /110 mm diaP.V.Cventilation&rainwaterpipes &mendinggoodthedamagesincluding cost, conveyance , royalty, all labour, T&P,sundries, lead, lift, delift,labour cess,scaffoldingand curing etc completeingroundfloorand1stfloor and as per the direction of Engineer-in-charge. |
| 67 | Providingandfixing onwall face 75mmdiaunplasticisedrigidUPVCpipe (4 Kg / sqcm) Soil andwastewaterpipesofFinolex / Ashirbad / OriplastconfirmingtoIS : 14735type\"B\"includingjointingwithsolventfit,singlesocketedpipesfordrainageofwastewaterfromkitchen&bathroomsincludingallcostoflabour, T & P, sundries,PVCclamp,nail,scaffoldingandlabourcessetccomplete and as per the direction of Engineer-in-charge. |
| 68 | Supplyingallmaterials,jointingofmaterialsincluding all labour, T & P, sundries,labourcess andfixingofUPVCSWRpipesincluding all fittingsetccomplete and as per the direction of Engineer-in-charge. |
| 69 | 110 mm x 87. 5°plainbend. |
| 70 | 110 mm x 87. 5°door bend. |
| 71 | 110 mmsingleTeewithdoor. |
| 72 | 110 mmdia WCBendwithlipring . |
| 73 | 110 mmdiaUPVCventcowl. |
| 74 | 75 mmx 87.5°Doorbend. |
| 75 | 110 mmPVCClamp. |
| 76 | 75 mmPVCClamp. |
| 77 | Providing, alignment& fixingofcollapsiblegrillshutterapproximateweight65 .00 kgpersqm inpositionwithcementconcrete (1:2:4) using 12 x2 mmand bracedwithflat irondiagonals 20 x 5 mmsizewithtop&bottomrailof \"T\"iron 40 x400 x6 mmwith40mm diasteelpullyscompletewithbolts, nuts, lockingarrangements,stoppers, handles,carriage,fixingchargesandlabourcessetccomplete and as per the direction of Engineer-in-charge. |
| 78 | Electrical Re-installation to Training Hostel Qtr. No. F-54/1, F-54/2, F-54/3, F-54/4, F-55/1, F-55/2, F-55/3 and F-55/4 at Power House Colony, UKHEP, Bariniput |
| 79 | LIGHT POINT: Surface wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor with ISI marked with 20mm dia non-metallic PVC flexible conduit with 5 Amp, 250V Modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover with suitable size, MS box with 1.5 Sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in Charge. (Make of wire Finolex/ L&T/ Anchor/ Polycab/ Havels/ V Guard) |
| 80 | a) Group-A |
| 81 | b) Group-B |
| 82 | c) Group-C |
| 83 | FAN POINT: Surface wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor with ISI marked with 20mm dia non-metalic PVC flexible conduit with 5 Amp, 250V Modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover with suitable size, MS box with 1.5 Sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in Charge. (Make of wire Finolex/ L&T/ Anchor/ Havels/ Polycab/ V Guard) |
| 84 | a) Group-A |
| 85 | b) Group-B |
| 86 | c) Group-C |
| 87 | CALL BELL POINT: Surface wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor with ISI marked with 20mm dia non-metallic PVC flexible conduit with 5 Amp, 250V Modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover with suitable size, MS box with 1.5 Sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in Charge. (Make of wire Finolex/ L&T/ Polycab/ Anchor/ Havels/ V Guard) |
| 88 | c) Group-C |
| 89 | Surface wiring to submain in 2 X 1.5 Sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in 20mm dia non-metallic heavy duty PVC flexible conduit 1.6mm thick alongwith 1 X 1.5 Sq.mm. FR PVC insulated single core multistrand copper conductor as earth wire as required. ( Make- Finolex/ L&T/ Anchor/Polycab/ Havels/ V Guard) |
| 90 | Surface wiring to submain in 2 X 2.5 Sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in 20mm dia non-metallic heavy duty PVC flexible conduit 1.6mm thick alongwith 1 X 1.5 Sq.mm. FR PVC insulated single core multistrand copper conductor as earth wire as required. (Make- Finolex/ L&T/ Polycab/ Anchor/ Havels/ V Guard) |
| 91 | Surface wiring to submain in 2 x 4 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC flexible conduit 1.6mm thick alongwith 1 X 1.5 Sq.mm. FR PVC insulated single core multistrand copper conductor for loop earthing as required. ( Make- Finolex/ L&T/ Polycab/ Anchor/ Havels/ V Guard) |
| 92 | Supply & fixing of 5 pin 5/6 Amp modular socket outlet on the existing switch box/ cover including connections as required |
| 93 | Supply & fixing of 5 pin 5/6 Amp modular switch on the existing switch box/ cover including connections as required |
| 94 | Supply & fixing of 5 Amp modular Bell Push ISI Marked switch on the existing switch box/ cover including connections as required. |
| 95 | Extension Board 5/6 Amp: Supply & fixing of modular base & cover for 6 module on surfacewith suitable size of phenolic laminated sheet cover infront including providing and fixing 5 pin 5/6 amps modular Socket outlet and 5/6 amps modular switch, connection, painting etc as required. |
| 96 | FOR POWER PLUG/ 32AMP MCB/ DP SWITCH/DP MCB: Supply & fixing of 16/18 SWG metal box of size 200mm x 150mm x 75mm deep (nominal size) on surface with suitable size of phenolic laminated sheet cover infront of it as required. |
| 97 | FOR GYSER POINT: Supply & fixing of modular base & cover for 4 module on surface with suitable size of phenolic laminated sheet cover infront including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required. |
| 98 | FOR AC POINT: Supply & fixing of 32 amp DP MCB on the exisitng switch box/ cover including connections as required. |
| 99 | FOR KITCHEN ROOM:Supply & fixing of 32 amp DP switch on the exisitng switch box/ cover including connections as required. |
| 100 | Supply and fixing of modular base angle holder of ISI marked, including connection etc as required. |
| 101 | Installation, testing & commissioning of pre-wired fluorescent fitting/ compact fluorescent fitting of all sizes complete with all accessories and tube etc directly on ceiling wall, including connection with 1.5 Sq.mm. FR PVC insulated single core multistrand copper conductor and earthing as required. |
| 102 | Installation, testing & commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 Sq.mm. FR PVC insulated single core multistrand copper conductor and earthing as required. |
| 103 | Installation, testing & commissioning of 10 Amp Step Type ceiling fan Regulator (make Anchore / Roma) in the existing switch box including connection with 1.5 sqmm FR PVC insulated single core multi strand copper conductor, earthing the regulator as required. |
| 104 | BOARD FOR BDB BOX: Supply & fixing of 16/ 18 SWG metal box of sizes 250mm X 300mm X 100mm deep on surface with suitable size of phenolic laminated sheet cover infront of it as required. |
| 105 | BDB BOX: Supply & fixing of 8 Way single pole Double Door MCB DB with sheet steel enclosure, distribution board, on surface, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required. (But without MCB/ RCCB/ ISOLATOR) |
| 106 | BOARD FOR MAIN SWITCH: Supply & fixing of 16/ 18 SWG metal box of sizes 250mm X 300mm X 100mm deep on surface/ recess with suitable size of phenolic laminated sheet cover infront of it as required. |
| 107 | MAIN SWITCH: Supply, installation, testing and commissioning of63 Amp DP Main switches Rotary type(IS 13940 Part-3, 1993) on the existing surface/ wall mounting and complete with HRC fuse links, interconnections, earthing etc as required as per direction of Engineer in Charge. Make (SEIMENS/ HPL/ ANCHOR/ L&T/ HAVELS/ C&S/ RK). |
| 108 | Supply & fixing of 6 Amp to 32 Amp rating 240V \"B\" series miniature circuit breaker suitable for lighting and other loads of single pole and neutral in the existing MCB DB ISI marked complete with connections, testing and commissioning as required. |
| 109 | Earthing with G.I. Earth pipe 3 mtr long 40mm dia ISI marked including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal and salt as required. |
| 110 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in surface PVC conduit with 2 way modular type switch with ISI marked, phenolic laminated sheet suitable size ISI marked G.I box(18 SWG) and earthing point with 1.5 sq. mm FR PVC insulated single core multistrand copper conductor for loop earthingetc as required ( make of wire - Finolex/ L&T/ Anchor/Havels/ V Guard. |
| 111 | Exhaust fan (300 mm), make of Usha / Havels etc. |
| 112 | Exhaust fan ( 200 mm ) , make of Usha / Havells etc. |
| 113 | 48\"\" A/C Ceilling fan make of Usha/ Crompton |
| 114 | 4 feet 20 watt LED tube light make of Crompton/ havells etc. |
| 115 | 15 Watt LED Foot Light |
| 116 | 10 Ltr storage water heater make of crompton/havells/ hindware etc |
| 117 | Labour Charges for fixing 10 Ltr water heater |
| 118 | 6 sqmm PVC insulated Aluminium black flat twin core wire |
| 119 | G.I. wire 10 SWG as tension wire for service wire |
| 120 | 4\"\"I Bolt for service wire |
| 121 | Labour Charges for fixing Service Pipe |
| 122 | Bare copper wire 8 SWG for Earthing |
| 123 | 190 watt LED Street light make of Bajaj / Havels/ crompton etc. |
| 124 | 2\"\" GI Pipe stand, clamp, nut & bolt for fixing 190 watt LED Street Light. |
| 125 | Labour Charges for fixing 190 watt LED Street Light |