| 1 | Dismantling of ACSR or AAC conductors and removing old material from site for taking credit. |
| 2 | DismantlingSteel tubular poles of any size and removing old material fromsite for taking credit and making good the disturbed surfaces all as specified/directed by Engr-in-Charge |
| 3 | Dismantling insulators any type, any size and revoming old material from site for taking credit |
| 4 | Dismantling stay assembly any type, any size and revoming old material from site for taking credit (demolition of concrete, etc. and excavation measured separately) |
| 5 | Dismantling and taking out old unsv XLPE cable any size alongwith DWC pipe and setting aside for credit complete. |
| 6 | Excavation in trenches n exc 1.5m wide and n exc 1.5m deepand making goodsurface for laying /removing of cable all as specified and directed by Engr in charge as in |
| 7 | (a) Soft/loose soil |
| 8 | (b) Hard/dense soil |
| 9 | Excavating in trenches,hard/dense soilexc 1.5 m wide and in depth beyond the first 1.5 mfor foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan andd getting out Complete all as specified and directed by Engr-in-Charge. |
| 10 | Returning filling in excavated soil in trenches, watering and well ramming in layers n exc 25 cm complete all as specified. |
| 11 | Removal of surplus excavated spoil to distance n exc 50metre all as specified and directed |
| 12 | M & L for bituminous road cutting to a width of 45 cm and depth 50 cm for laying ofpipe for laying of UG cables and making good with PCC (1:3:6) type cI (using 20mm grade stone aggregate) |
| 13 | M&L PCC(1:4:8) type C-2 using 40mm graded stone aggregates as in foundadion filling and mass concrete ( for foundation bed concrete in stay poles or any other directed site ) complite all as specific and directed |
| 14 | M&L PCC(1:3:6) type C-2 using 40mm graded stone aggregates as in foundadion filling and mass concrete( for foundation bed concrete in stay poles or any other directed site ) complite all as specific and directed |
| 15 | M&L PCC(1:2:4) type B-1 using 20mm graded broken stone aggregates ( for coping over ground level in stay poles or any other directed site ) incld Formwork complite all as specific and directedby Engr-in-Charge. |
| 16 | Supplyingand layingGI tubing light grade of size 40mm dia bore for encasingcables for mechanical protection , laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or alongpoles or as street light poles or as street light mounting bracketwith complete accessories such as bends/sockets/reducers/saddlesincl necessary threading/drilling worksall as specified and directed by Engr-in-charge. |
| 17 | Supplyingand layingGI tubing light grade of size 50mm dia bore for encasingcables for mechanical protection , laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or alongpoles or as street light poles or as street light mounting bracketwith complete accessories such as bends/sockets/reducers/saddlesincl necessary threading/drilling worksall as specified and directed by Engr-in-charge. |
| 18 | Supply , laying and testing cable XLPE insulated screened pvc bedded galvanised steel strip or wire armoured , electric power cables ( heavy duty) with stranded aluminium conductor 1100 volts grade in trenches/ passing through pipe/fixing on walls, floors etc incl connection with proper sizes lugs and gland, suitable clamp of cross sectional area2 core 10 Sqmm all as specified and directed. |
| 19 | All as per item 16 above but of the size 4 core 16 Sqmm |
| 20 | All as per item 16 above but of the size 3.5 core 25 Sqmm |
| 21 | All as per item 16 above but of the size 3.5 core 70 Sqmm |
| 22 | All as per item 16 above but of the size 3.5 core 95 Sqmm |
| 23 | Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene with smooth internal and profiled external surface for non pressure under ground cableincl couplers & bends complete all as specified. |
| 24 | Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 77 mm and inner dia 63 mm polythylene with smooth internal and profiled external surface for non pressure under ground cableincl couplers & bends complete all as specified. |
| 25 | M & L and erect in true vertical position (or to be fixed in an inclined position as strut pole) steel tubular swaged poles complete with MS base plate of 6 mm thick of size 300 mm x 300 mm, finial taper plug, pole cap, bolts, nuts and washers and screwed pole made out of FRW MS tubing conforming to IS-2713 (Part-II) 1980 type 410-SP-31 ( 9 meters long ) pole including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, etc complete all as specified and directed |
| 26 | Supply, installation, testing and commissioning weather and vermin proof factory made CPRI approved LT feeder pillar box, out door cubicle/KIOSK typetotally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm grouted in CM, 45 cm below ground level and 60 cm above roundsuitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminum bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set, size 1.2 x 1.0 x 0.5 Mtr (approx) including connecting the following:- |
| 27 | (a) Aluminiumbus barrectangular 600 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01 job(b)MCCB 250 Amps, TPN, 415 Volts, 50 Hz ,50 KA- 01 No ( Incoming) (c)MCCB 160 Amps, TPN, 415 Volts, 50 Hz ,25 KA - 02 No ( Outgoing) (d)MCCB 63 Amps, TPN, 415 Volts, 50 Hz ,16 KA - 01 No ( Outgoing) (e)MCCB 40 Amps,TPN, 415 Volts, 50 Hz ,16 KA - 02 No ( Outgoing) (f) Three pole Contactor 63 A Current Rating 70A General use 10A, 415V with coil- 01 N0 |
| 28 | (g)RYB LED Indicator Lamp- Set of Three-01(h) Volt meter 0-500 Volt with selector switch(l) Amp meter 0-600 Amp with selector switch with CT-03 Nos(m)Provision of cubicle to accommodate the above mentioned accessories.(n)Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable. |
| 29 | Supply, installation, testing and commissioning weather and vermin proof factory made CPRI approved LT feeder pillar box, out door cubicle/KIOSK typetotally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm grouted in CM, 45 cm below ground level and 60 cm above roundsuitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminum bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set, size 1.2 x 1.0 x 0.5 Mtr (approx) including connecting the following:- |
| 30 | (a) Aluminiumbus barrectangular 400 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves.-01 job(b)MCCB 200Amps, TPN, 415 Volts, 50 Hz ,36 KA- 01 No ( Incoming) (c)MCCB 100Amps, TPN, 415 Volts, 50 Hz ,25 KA- 01 No ( Outgoing)(d) MCCB 40Amps, TPN, 415 Volts, 50 Hz , 16 KA- 06 No ( Outgoing)(d) MCB SPN 32Amps, SPN , 415 Volts, 50 Hz ,16 KA- 03 No ( Outgoing) |
| 31 | (e)RYB LED Indicator Lamp- Set of Three-01(f) Volt meter 0-500 Volt with selector switch(g)Amp meter 0-600 Amp with selector switch with CT-03 Nos(h)Provision of cubicle to accommodate the above mentioned accessories.(j)Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable. |
| 32 | Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 33 | M & L for fabrication of junction box made out of fibre material complete with TPN ,aluminium bus and suitable for one number MCB (SP) including one No MCB (SP) 10 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular polecomplete all as specified and as directed by Engr-in-Charge. Make: Havells/Sintex. |
| 34 | Supply and fixing Service bracket made up ofGI tubing light grade of size 40mm dia bore for 1.5 mtr long one nos of 45* bent suitable size of nut bolts, two nos of clamps one coat of primer & two coat of paints. Complete all as specified and directed. |
| 35 | S&F of PVC insulated cable with copper condcutor 1.5 sqmm three core drwan through pole from pole junction box to street light connector and testing complete. |
| 36 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel,Excavation and earth work or drilling hole for,electrode, P.C.C. pit and C.I. cover, Funnel with watering pipe, wire mesh and copper lugs etc. as specified,G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injuryor tempering, Test point and extra length of main earthing lead beyond 7.5 metres, Connecting lead from test point to main switch or switch board or equipment to be earthed On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 37 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead Streep 25 X 4 dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel,Excavation and earth work or drilling hole for,electrode, P.C.C. pit and C.I. cover, Funnel with watering pipe, wire mesh and copper lugs etc. as specified,G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injuryor tempering, Test point and extra length of main earthing lead beyond 7.5 metres, Connecting lead from test point to main switch or switch board or equipment to be earthed On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |