| 1 | Civil Work- CONSTRUCTION OF 900 MT GODOWN & PROCESSING SHED204.35 Sq Mt |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 mbeyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Manual Means |
| 3 | Providing and laying in situ cement concrete of 1:4:8 proportion with trap/ granite/ quartzite/ gneiss metal in foundation including necessary form work, compacting and curing etc. complete. (with reversible drum rtype mixer with SCADA with Natural / VSI standard Artificial Sand) |
| 4 | Providing and laying in situ/Ready Mixcement concreteM-20of trap / granite /quartzite/ gneissmetal for R.C.C. workin foundations like raft, strip foundations, grillage andfootings of R.C.C. columns and steel stanchionsetc. including bailing out water, formwork, laying/pumpingcover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand |
| 5 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand |
| 6 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand |
| 7 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. |
| 8 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 9 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/ pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 10 | Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineer inchargein layers of 15 cmto 20 cm including watering and compaction etc. complete. |
| 11 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. |
| 12 | Providing internal cement plaster 20mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. |
| 13 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 14 | Providing and laying cement concrete flooring 50 mm thick with M20 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally /square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete. With Natural Sand |
| 15 | Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to Newplastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc.complete. |
| 16 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear) |
| 17 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. |
| 18 | Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.). |
| 19 | Providing and fixing plain zinc sheeting of 0.80 mm thick (22 B.W.G.) over the ridge hip or valley to galvanized iron sheet roofing including all fastening and bolt galvanised iron screws and bolts, lead and bitumen washers etc. complete.(Weight of 6.8 Kilogram/sq.m.). |
| 20 | Providing and fixing 22 B.W.G. plain galvanised iron sheets on top of weather shed, including scaffolding, fixing by means of nut and bolts or as directed etc. complete. (Brackets of 70 x 45 mm to be paid separately) |
| 21 | LAB TESTING CHARGES Cement - Fineness,Standard Consistency, Setting Time (Initial & Final ), Compressive strength, Soundness |
| 22 | Concrete M-20 - Mix Design with all tests on basic materials |
| 23 | Concrete M-25, M20 and M-10 grade - Concretecompressive strength |
| 24 | Crushed metal - Water absorption, Specific gravity,Impact value,Crushing value |
| 25 | Brick - Crushing value, Water absorbation, & Specific Gravity |
| 26 | Steel - Tensile strength ,Yield stress, ultimate tensile stress, %elongation, weight per running meter,Bend/Rebend test.(Set of 3 Bars) |
| 27 | Murum - Plasticity Index |
| 28 | Sand Test -Sieve Analysis, Silt Connect Test |
| 29 | Aggregate Impact Value Test (A.I.V.) ( Grade I + Grade II), Water Absorption Test ( Grade I + Grade II),Flakiness Test (Grade II) |
| 30 | (a) For Sand |
| 31 | (b) For Metal & Murum |
| 32 | ELECTRIFICATION WORK :- Single core PVC insulated copper wire 15 sq.mm. |
| 33 | Bulb 60W Pin type |
| 34 | CFL 23 w Holder ltyupe |
| 35 | Switch MCCB 100A |
| 36 | MCB 20 Amp |
| 37 | Tubne Road 36 W |
| 38 | 6 M Modular PVC Box |
| 39 | Switch 15A |
| 40 | Socket 15 A |
| 41 | Choke 18 Watt for 4 pin CFl |
| 42 | 3 Core, 25 sq.mm. flexible PVC insulated cable |
| 43 | Connector strips 10A (12 Point) |
| 44 | Plug Top 25 A. 3 Pin |
| 45 | PVC Tape roll |
| 46 | Batten nail |
| 47 | Tube Starter 20-65 W |
| 48 | Terminal power strip, 15 Amps, 3 Socket 3 Switch |
| 49 | Prviding and managing 20 Trees in the same premises, under Management Strategies And Implementation Plan ( MSIP ) to ManageEnvironmental , Social , Health And Safety. |