| 1 | 13.37 Removing dry or oil bound distemper, water proofingcement paint and the like by scrapping, sand paperingand preparing the surface smooth including necessaryrepairs to scratches etc. complete. |
| 2 | 12.35 Distempering with 1st quality acrylic distemper (readymixed) having VOC content less than 50 grams/ litre, ofapproved brand and manufacture to give an even shade [Payment shall be made after submission of TestCertificate issued by the Manufacturer] : 12.35.1 New work ( two or more coats) over and including waterthinnable priming coat with cement primer. |
| 3 | 13.30 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under including cutting the patch in proper shape and preparing and plastering thesurface of the walls complete including disposal of rubbish to the dumping ground with all leads and liftsincluding finishing even and smooth and curingcomplete as per direction of the Engineer in charge:- 13.30.1 With cement mortar 1:3 ( 1 cement : 3 fine sand ). |
| 4 | Miscelleneous and ancilliary workscleaning works as per site condition (MR) |
| 5 | 9.24 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 9.24.1 4.0 mm thick glass panes |
| 6 | 12.47 Painting with synthetic enamel paint (two or more coats) of required colour of approved brand and manufacture on new work to give an even shade. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]. |
| 7 | 8.66 Providing and fixing oxidisedM.S. casement stays(straight peg type) with necessary screws etc.complete.8.66.3 200 mm weighing not less than 120 gms. |
| 8 | 8.94 Providing and fixing aluminium sliding door bolts ISI marked anodized (an odic coating not less than grade AC10asperIS:1868) transparent or dyedtorequiredcolour or shade with nuts and screws etc. complete :8.94.2 250x16 mm |
| 9 | 18.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the wallsand floors wherever required :18.2.2 W.C. pan with ISI marked black solid plastic seat and lid |
| 10 | 18.83 Providing and fixing on wall face unplasticised RigidPVC soil, waste & vent pipes (working pressure 6 kg /cm2) conforming to IS : 13592 Type A includingjointing with seal ring conforming to IS : 5382leaving10mmgapforthermalexpansion:18.83.1 Single socketed pipe - 110 mm OD |
| 11 | 10.40 Providing and fixing 1st class quality ceramic glazed walltiles conforming to IS : 15622- 2017 (thickness to bespecified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-incharge in skirting, risers of steps and dados, laid over 12mm thick bed of cement mortar 1 : 3 (1 cement : 3 finesand) jointed with ordinary cement slurry includingpointing with white cement mixed with pigment ofmatching shade etc. all complete as per direction of the Engineer in-charge. 10.40.1 450 mm X 300 mm in all shades and design |
| 12 | 10.42 Providing and laying 1st class quality vitrified floor tilesin different sizes (thickness to be specified by themanufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in allcolours and shades, laid over 20mm thick cement mortar1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints withwhite cement and matching pigments etc. all complete asper direction of the Engineer-in-charge.. 10.42.2 Double charged Stainfree vitrified tiles (Glossy)10.42.2.1 Size of tile 600 mm x 600 mm |
| 13 | 19.10 ProvidingandfixingG.I.pipesofmedimclassasper IS : 1239with latest amendment completewithG.I.fittings and clamps, including cutting andmakinggood the walls etc. complete as per CPWDspecification and direction of the Engineer- incharge. Internal work - Exposed on wall. 19.10.1 15 mm dia. nominal bore |
| 14 | Providing and fixing C.P.Brass bib covk of approved quality conforming to IS:8931: 15 mm nominal bore. |
| 15 | 8.19 Providing and fixing ISI marked flush door shuttersconforming to IS: 2202 (Part I) non-decorative type,core of block board construction with frame of 1stclass hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veeners on both faces of shutters. 8.19.1 35 mm thick including ISI marked Stainless Steel butthinges with necessary screws. |
| 16 | 18.10 Providing and fixing Stainless Steel AISI 304 (18/8)kitchen sink as per IS 13983 with C.I. brackets andstainless steel plug 40 mm including painting of fittingsand brackets, cutting and making good the wallswherever required:18.10.1 Kitchen sink with drain board 18.10.1.1 510x1040 mm bowl depth 250mm. |
| 17 | 8.114 Providing and fixing factory made UPVC door framemade of UPVC extruded, section having an overalldimension, as below (tolerance +/- 1mm) with wall thickness 2.0mm+/- 02mm. corners of the door frameto be jointed with galvanized brackets and stainlessscrews, joint mitred and plastic wilded. The hinge sidevertical of the frames reinforced by galvanized MStube of size 19 × 19 mm and 1 mm +/- 0.1 mm wallthickness and 3 nos stainless steel hinges fixed to the frame complete as per manufacturers specificationand direction of Engineer-in-Charge. 8.114.1 Extruded section Profile size 48x40 mm. |
| 18 | 8.115 Providing and fixing to existing door frames. 8.115.1 24 mm thick factory made PVC door shutters made ofstyles and rails of a UPVC hollow section of size 59x24mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred andjoined at the corners by means of M.S. galvanised/plastic brackets of size 75×220 mm having wallthickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserying galvanised MStube of size 20×20 mm and 1 mm ± 0.1 mm wallthickness. The lock rail made up of \"H\" Section, a UPVChollow section of size 100×24 mm and 2 mm ± 0.2 mm wall thickness fixed to the shutter styles by means ofplastic /galvanised MS \"U\" cleats. The shutter framefilled with a UPVC multi-chambered single panel of sizenot less than 620 mm, having overall thickness of 20mm and 1 mm ± 0.1 mm wall thickness. The panelsfilled vertically and tie bar at two places by insertinghorizontaly 6 mm galvanised MS rod and fastened with nuts and washers, complete as per manufacturer\"sspecification and direction of Engineer-In-Charge. (for W.C. and Bathroom door shutter). |
| 19 | 16.1.2 For shutters of doors, windows & ventilators includingproviding and fixing hinges / pivots and making provision for fixing fittings wherever required includingthe cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ): 16.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodiccoating of grade AC 15). |
| 20 | 16.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up ofgaps at junctions, i.e. at top, bottom and sides withrequired EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred andjointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineer in charge. (Glazing and paneling and dash fasteners to be paid for separately) :16.1.1 For fixed portion of approved quality:16.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 21 | 17.14 Grading roof for water proofing treatment complete asrequired as per direction of the Engineer-in-charge with :17.14.1 Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 22 | hinges with necessary screws. |