Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-04-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 14-04-2025 |
| 2 | 02-04-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-04-2025 |
| 3 | 19-03-2025 | Correct BOQ | BOQ | 02-04-2025 |
| 4 | 19-03-2025 | Amendment to Critical Dates | Date | 02-04-2025 |
| Sl. No. | Item Description |
| 1 | Site clearance of soft /loose soil of vegitations, bhuses and shrubs etc. |
| 2 | Excavation in trenches, n exc 1.50 mtr wide and n exc 1.50 mtr in depth, for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 Sqm on plan and n exc 1.50 mtr in depth and getting out in hard densesoil complete all as specified by Engineer-in-Charge. |
| 3 | Material and labourforPCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concretecomplete all as specifiedby Engineer-in-Charge |
| 4 | Returning filling in soft/loose soil,including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specifiedby Engineer-in-Charge. |
| 5 | Removing excavated material / soil exc 250 m but n. exc 500 m and depositing whereasdirectedby Engineer-in-Charge. |
| 6 | M&L for Muroom/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and watering and well ramming by mechanically complete all as specified and as directed by Engineer-in-charge. |
| 7 | M&L forhard core of gauge n exc 63 mm broken stone or boulders deposited spread and levelled in layers n exc 15 Cm thick, watered and rammed to a true surface broken stone or boulders complete all as specifiedby Engineer-in-Charge. |
| 8 | Material and labourfor cement concrete type B11:2:440mm thick(20mm graded stone aggregates)for floors finishes complete all as specifiedby Engineer-in-Charge |
| 9 | Material and labour for mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, slabs, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirming to TMT bars complete all as specifiedby Engineer-in-Charge |
| 10 | Ditto as per item no09but 6mm to 8mm diain stirrups, spaces and binderscomplete all as specified complete all as specifiedby Engineer-in-Charge |
| 11 | Material and labour for reinforced cement concrete(Nominal) mixtype B1 1:2:4 20 mm graded stone aggregate for Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, under reamed piles and mass concrete complete all as specified and as directedby Engineer-in-Charge |
| 12 | Material and labour for reinforced cement concrete(Nominal mix)type B1 1:2:4 20 mm raded stone aggregate for columns, pillars, piers, posts and strutscomplete all as specified and as directedby Engineer-in-Charge |
| 13 | Material and labour for reinforced cement concrete(Nominalmix) type B1 1:2:420mm graded stone aggregate for slab supported on walls, beams and columns in floors, roofs landings, balconies, canopies, deck slab sand in shelves and the likecomplete all as specified and as directedby Engineer-in-Charge |
| 14 | Material and labour for reinforced cement concrete(Nominalmix) type B1 1:2:420mm graded stone aggregate for chajjas/ roof projections mass concrete complete all as specified and as directedby Engineer-in-Charge |
| 15 | Material and labour for reinforced cement concrete ((Nominalmix type B1 1:2:4 20mm graded stone aggregate forbeams/roof beam, cantilevers, bressumers, lintel over 1.5m spancomplete all as specified and as directedby Engineer-in-Charge |
| 16 | Formwork to side of concrete foundation, footing, bases of column raft and raft beams, side and soffits (if any)of foundation and plinth beams and similar work; vertical or to batterflat withrougth finished surfaceof concrete complete all as specifiedby Engineer-in-Charge |
| 17 | Formwork to side of pillars, posts. struts, piers, column and stsnchions finished surfaces of concretesquare, rectangular or polygonal. |
| 18 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) of fair finished flat surface of concrete complete all as specifiedby Engineer-in-Charge |
| 19 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc flat withfair finished of concrete. |
| 20 | Demolition of brick work or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specifed and directedby Engineer-in-Charge |
| 21 | Material and labour for brick work with Sub class \"B\" bricks, straight or curved on plan exc 6m mean radius built in Cm (1:6) all as specifiedby Engineer-in-Charge |
| 22 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water etc. |
| 23 | Material and labour for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished fair and even without using extra cement complete all as specifiedby Engineer-in-Charge |
| 24 | M &L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement, complete all as specifiedby Engineer-in-Charge |
| 25 | M &L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement,including water proofingliquid complete all as specified. Note water proofing compound mesured and paid separately. |
| 26 | M &L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement,including water proofingliquid complete all as specified.Note water proofing compound mesured and paid separately. |
| 27 | Supplyonly Liquidwater proofing compound MakeFosrock ,Dr fixit or equivalent . |
| 28 | Material labour for applying two coats of Dr Fixit damp guardepoxy painting as in two layers on plastered surface ofRCC wall /brick wall internal surface and external surfacecomplete all as specified and as directedby Engineer-in-Charge |
| 29 | Material and labour for rendering 5 mm thick in cement mortar 1:3 as in ceilingsurfaces, finished fair and evenwithout using extra cement complete all as specified. |
| 30 | M&L for preparation of new plastered surface of ceiling andapplyingthree coat of white wash complete all as specified and as directedby Engineer-in-Charge |
| 31 | M&L for newly plasterdinternally surfaceof walls two coats of oil emulsion distemper with 1st quality(ready mixed) having VOC content less than 50gms/litre, of approved manufacturer, of required shade and colour complete, as permanufacturer\"s specification.Note: necessarysaftey precautions , ladder/scaffoliding etc arranged by contractor. |
| 32 | Material and labour fornewly plateredexternal surface of walls with Acrylic smooth anti fungal exterior paint of required shade preparing and applying two coats applied @1.67lts/10sqm over and including over alkali resistance primimg paintone coat of primer smooth finish etc of approved make & shade on walls and other places complete all as specified and as directedby Engineer-in-Charge.Note: necessarysaftey precautions , ladder/scaffolding etc arranged by contractor. |
| 33 | M&L forcomplete removal of existing treatment ofold surface/priming plasterd and otherwall /ceiling surfaces and praparing and applying two coat of oil emulsion distember over alkali resistance primimg paint primer over two coats of white cement based wall care putty smooth finish etc of approved make & shade on walls and other places complete all as specified and as directedby Engineer-in-Charge. |
| 34 | Dismantling stone slabs and tiles of any description or thickness in kitchen platform and similar work laid, bedded and pointed in cement mortar complete all as specified and directedby Engineer-in-Charge |
| 35 | S&F machine cut and machine polished,green marble, 16-18mm thick in single piece as in cooking platform bedded, window cill, Jambs, Trade, Riser, landingetc jointed and pointed with neat grey cement slurry and pointed with coloured or white cement with pigment to match over and including rounding to edges and polishing andbacking coat of rendering 10 mm thick in CM 1:4 all as specified and directedby Engineer-in-Charge. |
| 36 | Dismantling of floor, hearth or wall tiling including cement mortar bedding complete all as specified and directedby Engineer-in-Charge. |
| 37 | M&Lfor non Skid ceramic coloured tiles 7 to 8 mm thick (desined pattren) (square/ rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15mm thick in CM (1:4)for laying floor tiles complete all as specified and as directedby Engineer-in-Charge. |
| 38 | S&F glazed ceramic coloured tiles (300mmx 450mmx7 mm) in vertical surfaces jointed in neat cement slurry and pointed in white cement. Incl cutting the tiles to the required size whereven required incl mitring the corners etc over 10 mm thick backing coats of cement plaster in CM (1:4) complete all as specified and directedby Engineer-in-Charge. |
| 39 | Demolition of cement concrete in groundfloors not exe 15cm thick of any description and in any position not otherwise specifically providedcomplete all as specified and directedby Engineer-in-Charge |
| 40 | Material and labour for providing 75mm thick plain cement concrete (1:3:6) type C-2 , using 20mm graded stone aggregate , laid in 1:20 slope in alternate bays as in plinth protection, surface finished even and smooth without using extra cement, complete all as specifiedby Engineer-in-Charge. |
| 41 | Taking down existing doors/windows/ventilators (without taking off shutters and guard bars) of n exe 1.5 sqmcomplete all as specified and as directedby Engineer-in-Charge |
| 42 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45*70 mm comprising of virgin PVC polymer fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screwsand resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. |
| 43 | S&FFactory Made 30mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Flush Door Shutter of required size comprising of virgin PVCand Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) having good screw holding capacity Minimum Compissive of 50 N/mm2,of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant complete all as specifiedby Engineer-in-Charge. |
| 44 | S&F Factory made single extruded WPC (Wood PolymerComposite)solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance tospread of flame of Class A category with property of being termite/borer proof,water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with nceessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 45 | S&F 30mm thickfactory made wire mesh solid WPC door shutter consisting of Density 500 Kg /Cbm Manufactured by an ISO-9001-2015 certified Company , Door to be panelled with SS mosquito Mesh 0.48mm dia and 1.40m aprtureand XTN aluminium Mesh for additional strength and safety purpose. (confirming as per IS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity includingDoor to be fixed to frame with 3 nos. M.S powder coated butt hinges size 100mmx25mmx2mm and 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares should be fixed with 19x6mm size steel screws etc. Complete as per direction of Engineer-in -charge, manufacturer\"s specification & drawings.Note:Make \"RAJSHRI\" Brand |
| 46 | S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheetmetal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be waterproof, termite proof, elegant and should have excellent screws holdingstrength to fix hinges and hold doors properly for a long life) complete all as specifiedby Engineer-in-Charge |
| 47 | S&FFactory Made 24 mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Flush Door Shutter of required size comprising of virgin PVCand Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) having good screw holding capacity Minimum Compissive of 50 N/mm2,of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant complete all as specified. |
| 48 | S&F Powder coated aluminum three track, three shutter (equal width) type window miniumum 50 micron with frame made of aluminum sections of size 91.80 x 31.75 x 1.0mm and shutters made out of aluminum sections 39.4 x17.7 x 1.0mm without sash bars including necessary jointing cleats, glazing clips, rubber packing, anodised snap beadings, screws aluminum fittings lockings arrangements etc including 4.00mm thick sheet glass for glazed shutters and stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm for wire gauge shutter all as specified and as directed,and as directedby Engineer-in-Charge. |
| 49 | S&F powder coated aluminum ventilator partly fixed and partly louvered type without sash bar section as per minimum 50 micron including necessary jointing, clip, rubber packing, anodised snap beading crews and 4mm thick pin headed glass etc complete all as specifiedby Engineer-in-Charge. |
| 50 | S&F in stainless steel sliding door bolt of 300mm longmedium weight complete all as specified and directedby Engineer-in-Charge |
| 51 | S&F in stainless steel butt hinges, 100mm,medium weight complete all as specified and directedby Engineer-in-Charge |
| 52 | S&F inextruded stainless steel handles, fabricated type of size 150mm in any position complete all as specified and directed by Engineer-in-Charge. |
| 53 | S&F instainless steel, barrel tower bolts of extruded section of size 200mm complete all as specified and directed by Engineer-in-Charge. |
| 54 | Demolition and removing sunken slab filling of brick bats/cinder/light weight concrete including plastering on sunken floor/sides of floor slab/tiles of toilets in all the floors including all the water and sanitary fixtures and removing all rubbish/debris outside MoD land as per instruction complete all as specifiedand directed by Engineer-in-Charge. |
| 55 | The suken floor RCC slab including sides to the full extent of sunken portion in upper floor shall be prepared and plastered with 15 mm thick cement plaster in CM 1:3 with water proofing compound as per manufacturer\"s instructions and finished even and smooth without using extra cement. When the plaster is cured and dried up, apply a uniform coat of blown grade bitumen 85/25 @ 1.2 kg/Sqm confirming to IS 702 over a coat of primer @ 0.70 Kg.Sqm over plastered surface complete all as specified and as directed by Engineer-in-Charge. |
| 56 | Note :- Integral water proofing compound shall be measured and paid separately as \"Supply only\". |
| 57 | Water proofing treatment to Sunken floor slabe complete as specified bellow and as directed by Engineer-in-Charge. |
| 58 | (a) Provide and lay 4mm thick APP modified torch applied prefabricated five layer water proofing membrane weight not less than 3.60 Kg/Sqm. |
| 59 | (b) Apply a uniform coat of blown grade bitumen 85/25 @ 1.2 Kg/Sqm confirming to IS 702 of the surface area complete all as specified by Engineer-in-Charge. |
| 60 | M&L for PCC lean concrete 1:5:10 type E2 laidfor sunken floors complete all as specified and directed by Engineer-in-Charge. |
| 61 | M&L for 40 mm thick PCC 1:2:4 type B0 (12.5 mm graded )stone aggregate as padding concrete over lean concrete complete all as specified by Engineer-in-Charge |
| 62 | M&L for removal ofdamagedAPP mambraneof roof and roughening surfaces of concrete slab by picking, sweeping clean and washing down with water to remove dust etc and applying evenly cement slurry at the rate of 3kg / sqm over cleaned roof surfaces complete all as specified and as directed by Engineer-in-Charge. |
| 63 | Material and labour for PCC 1:2:4 type BO (using 12.50mm graded stone aggregate) for roof,kerbs or mud stops, roundedor chamfered on eds etc including mixing of admixture fosroc SP 430 of M/S Fosroc chemical @ 250ml per 50kg of cement over existing roof and in padding concrete to maintain required slope and minimum thickness being 25 mm complete all as specified and as directed by Engineer-in-Charge.Note:- WPC will be measured and paid separetly under respective item. |
| 64 | Supply only of admixture fosroc SP 430 Chemical all as specified and as directed by the Engineer-in-Charge. |
| 65 | Material and labour for screed bed layer 10 mm thick in CM 1:4 onconcrete surfaces of roof, mixed with integral water proofing compound @ 3% by weight ofcement,finished even and smooth without using extra cementcomplete all asspecified and directed. Note:- WPC will be measured and paid separetly under respective item. |
| 66 | Supplyliquidwater proofing compoundmake Fos roc or equivalent make |
| 67 | Material and labour for cleaning the entire roof surface thoroughly to remove all loose particles,dust/dirt particles and applying withone coat of industrial bitumen 85/25 grade at the rate of 1.20 kg/sqm over the plastered surfaces of roof over and included APP based polymeric membrane minimum weighing 3kg/sqm and minium 3mm thick reinforced with polyester non woven fabric (weight not less than 150 gms/ sqm) laid on primed surfaces by gas flame torch application and applying evenly industrial bitumen 85/25 grade at the rate of 1.20kg/sqmover APP membrane complete all as specified and as directed by Engineer-in-Charge.Note:- Make/ brand ofAPP modified membrane with all associated items shall be any one of Super Thermolay of STP Ltd or Torch Sheild \"P-3160\" of Pidilite Industries Ltd or Hyper Plas Polyster of IWL (INDIA) Limited or Super Sheild of M/s Shalimar Bituchem India Pvt Ltd or Torch Tor of Torch Tor Membranes and Bitumen Products Pvt Ltd. |
| 68 | Material and labour fortwocoatsAluminium paint over APPbased polymeric membrane complete all as specified and as directed by Engineer -in -charge. |
| 69 | Dismantling of water tanks exc 500 & n exc 1000 ltr capacity and removingfrom site complete all as specified and directed by Engineer-in-Charge. |
| 70 | S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 ltrs capacitytriple layered hoisted and fixed in positionincluding 25mm dia float ball brass valve and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified by Engineer-in-Charge |
| 71 | Cutting to brick wallschases, pinning in. making good to facings where required andpointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified by Engineer-in-Charge. |
| 72 | Taking down 15mm dia bore GI steel tubing and connection including cleaning and making good dismantled surface complete all as specified by Engineer-in-Charge. |
| 73 | S&F CPVC pipes, SDR 11, 20mm outer dia conforming to IS-15778 with all fittings such as Tee, bends, elbows, unions sockets and end oieces etc to receive the fittings and fixed with concealedsolvent on walls/ceiling or laying in floors complete all as specified by Engineer-in-Charge. |
| 74 | S&F CPVC pipes, SDR 11, 25mm outer dia conforming to IS-15778 with all fittings such as Tee, bends, elbows, unions sockets and end oieces etc to receive the fittings and fixed with solvent on walls/ceiling or laying in floors complete all as specified by Engineer-in-Charge. |
| 75 | Taking down 20 mm dia bore GI steel tubing and connection including cleaningand making good dismantled surface complete all as specified by Engineer-in-Charge. |
| 76 | S&F 20 mmGI tubing medium grade with all fittings such as Tee, bends, elbows, unions sockets and end oieces etc to receive the fittings and fixed with solvent on walls/ceiling or laying in floors complete all as specified by Engineer-in-Charge. |
| 77 | S&F Vitreous china wash down water closet (Padestal pattern) pan white including bolts and flush pipe, pedestal pan and trap including connections to drain (or outgoing pipe) and flushing pipe etc including seat coverclosed type complete fixed in repairs complete all as specified by Engineer-in-Charge. |
| 78 | S&F Ceramicwater closet western toilet /commodewall/floor mounted dual typepan, in built dual flushing cistern white including bolts and flush pipe, drain (or outgoing pipe) and flushing pipe andetc including seat coverclosed typeetc complete all as specified by Engineer-in-Charge. Make:Cera , Jhonson ,Hindustan Parryware,or equivalent |
| 79 | S&F in repairs vitreous china water closet \"Orissa\" pattern of size 580mm X 440mm, white with integral foot rest(excluding flushing cistern), but including PVC flush pipe and provision of lime concrete bedding complete all as specified and as directed by Engineer-in-Charge. |
| 80 | S&F 10 litre PVC valve less, duel function syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified by Engineer-in-Charge. |
| 81 | S&F in repair Vitreous China urinals, bowl type (back to corner wall type), complete including providing and fixing plus, bedding urinal against wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (inclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified by Engineer-in-Charge. |
| 82 | S&F in repairs 600 X 450mm bevelled edge mirror, 5mm thick selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed with wooden plugs to wall with chromium plated brass screws and cup washers complete all as specified and as directed by Engineer-in-Charge. |
| 83 | S&F ceramic white wall hungcum counterWash basins,of size 13.6x11.8x5.1 inchor equavalentsizeWT cuba wall hung basin , including cutting for and pinning in ends of brackets or erecting stand but inclusive of fixing of supply and waste pipe, Including fancy type cromium plated pillar tap complete all as specified by Engineer-in-Charge. Make:Kemjo , suprem ,Cera , Jhonson ,Hindustan Parryware,or equavalent |
| 84 | S&F Vitreous china white flat back of size 450x300mm wash basins, vitreous china (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe fixed in repairs complete all as specified by Engineer-in-Charge. |
| 85 | S&F in repairFlush pipe of polyethylene of low or high density or PVC, 32mm dia for low level cistern complete all as specified by Engineer-in-Charge. |
| 86 | S&F Flush pipe of polyethylene of low or high density or PVC, 32mm dia for low level cistern complete all as specified by Engineer-in-Charge. |
| 87 | S&F in repairs hand shower (Health Faucet), ABS body chromium plated with15mm dia, pipiewith 1.25m long flexible tube and ABS wall hookincluding making connection s and fixed ibn positioncomplete all as specified by Engineer-in-Charge. |
| 88 | S&F in repairtoilet paper holder of stain less steelfixed to walls with cromium plated ( )brass screws complete all as specified by Engineer-in-Charge. |
| 89 | S&F in repairChromium plated shower rose with armwith or with out swivel joints ,any size ,including fixing to steel pipe or union etc complete all as specified by Engineer-in-Charge. |
| 90 | S&F in repairs Bib taps, fancy type, chromium platedwith crutchsc-rewed down, screwed for iron pipe or for brass ferrule and fixed 15 mm bore complete all as specified and as directed by Engineer-in-Charge. |
| 91 | S&F in repair Pillar taps, fancy type, chromium plated, screwed down, high pressure, with or without lettered ‘Hot\" or ‘Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed 15 mm bore complete all as specified and as directed by Engineer-in-Charge. |
| 92 | S&F in repair 15mm stop cock, cast copper alloy, fancy type chromium plated, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 93 | S&Fin repair soap dish of any typefixed to plugs with chromium platedwith brass screws complete all as specified and directed by Engineer-in-Charge. |
| 94 | S&F Flush pipe of polyethylene of low or high density or PVC, 32mm dia for low level cistern complete all as specified by Engineer-in-Charge. |
| 95 | S&FChromium plated shower rose witharms or with out swivel joints ,any size ,including fixing to steel pipe or union etc complete all as specified by Engineer-in-Charge. |
| 96 | S&F PVC (SWR) bends of 110mm bore with access door complete all as specified by Engineer-in-Charge. |
| 97 | M&L for PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110 mm bore including taking downcomplete all as specified by Engineer-in-Charge. |
| 98 | S&F PVC (SWR) Nahani /Floor trap, 75/110 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and as directed by Engineer-in-Charge. |
| 99 | M&L for PVC (SWR)75mmpipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors or wallsin cluding taking downcomplete all as specified by Engineer-in-Charge. |
| 100 | S&F PVC (SWR) bends of 75mm bore with access doorcomplete all as specified by Engineer-in-Charge . |
| 101 | S&F PVC (SWR) branch piece double Y equal or unequalof 75/110mm bore in radius complete all as specified by Engineer-in-Charge . |
| 102 | S&F in repair 100mm stain less steel gratingscomplete all as specified by Engineer-in-Charge. |
| 103 | M&L for cutting into existing manholes for connecting new drains, of 150mm dia welding good to pipe incl rendering, cutting out existing benching for and forming branch channel (1/2 round on 3/4 section in cement concrete 1:2;4 type B1 smooth finished and reforming benching as reqired. |
| 104 | M&L for reinforced concrete pipes class NP-2 ,200 mm dia laid and jointed coplete with collars including demolition and breaking up Existing SGSW/RCCpipes concrete bed including packing under and haunchingjointed in cement mortar and taking out of trenches if requiredetc,complete all as specifed and directed by Engineer-in-Charge. |
| 105 | M&L concrete bed to 200 mm dia pipes of cement mortar 1;3;6 type C-2 including packing under and haunching against the side of pipes after they are laid and tested complete all as specifed and directed by Engineer-in-Charge. |
| 106 | Demolition of concrete (un re-inforced)of any descriptionand in any positionnot other wisespecially provided for complete all as specifiedand as directed by Engineer-in-Charge |
| 107 | M&L Plain Cement Concrete Type B11:2:4(using 20 mm graded granite stone aggregate) in mass concrete etccomplete all as specified and directed by Engineer-in-Charge. |
| 108 | M&L for75mm thickplain cement concrete 1:4:8 mix,type D2 (using 40 mm graded stone aggregates) as in subbase to floor complete all as specified and as directed by Engineer-in-Charge. |
| 109 | M&L forchequered cement concrete with glossy finish tiles with grey cement and pigments 30cm x30cm x 22-25mm thick set and jointed in neat cementslurry in floors over and including 20mm screed bed in CM (1:6) complete all as specified and as directed by Engineer-in-Charge. |
| 110 | M& L for 80mm thickruber moulded glossy finishedconcrete interlockingpaver block any shape andsize conforming to IS 15658-2006 ,M-40 grade laid over sand cushioningafter consolidation set and level with grey cement and pigment , etc complete all as specified and as directed by Engineer-in-ChargeNote: sand cushion will be measured separetely. |
| 111 | M& L for sand cusionfilling under floorsincluding wateringand consolidation complete all as specified and directed by Engineer-in-Charge. |
| 112 | Excavating post holes or similar holes, each not exceeding 0.50 Cu. M, getting out in Hard/ Dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 100m &making good surfacecomplete all as specified and directed by Engineer-in-Charge. |
| 113 | M&L Plain Cement Concrete Type C21:3:6(using 20 mm graded granite stone aggregate) in foundations, filling and mass concretecomplete all as specified and directed by Engineer-in-Charge. |
| 114 | Dismantlingof wrought iron or mild steel work of any description not other wise providedfor complete all as specified by Engineer-in-Charge. |
| 115 | S&F for Expanded metal, weight exc 4kg/sqm cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples/welding supplied and fixed complete to steel members complete all as specified by Engineer-in-Charge |
| 116 | Dismantling structural steel work including doors, gates but excluding framed truss etc. |
| 117 | S&F Roof trusses (framed), trussed, posts, purlins, rafter,rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified by Engineer-in-Charge. |
| 118 | S&Ffor plates (plain or chequered ) channels , square cut or notched (ordinary and counter sunk) forming holes, without any attachement confirming .Fe410-Wgde-E-250 Quality A complete all as specified by Engineer-in-Charge. |
| 119 | S&F for Pre- Painted galvatume aluminiumzinc coating GI basedcorrugated steel sheet/plain sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws,complete all as specified and directed by Engineer-in-Charge. Note: Contractor provide galvalume sheet as per required shape with out any extra profit. |
| 120 | M&L for Preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of anticorrosive paint(Epoxy) over a coat ofprimercomplete all as specified and directed by Engineer-in-Charge. |
| 121 | Taking down 40 or 50mm dia bore GI steel tubing and connection including cleaning and making good dismantaled surface complete all as specified by Engineer-in-Charge. |
| 122 | S&F50mm dia boremedium grade GI steel tubing with all fittings and fixed complete to walls and ceilingsor laid in floors complete all as specified by Engineer-in-Charge. |
| 123 | S&F in repair 50mm boregun metal globe or gate valve ,with iron wheelhead ,screwed both ends or for iron pipie and fixed complete allspecified by Engineer-in-Charge |
| 124 | M & L for Point wiring with 2.5 (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and includingproviding PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 2.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed. (a) One light point or one fan pointor bell point controlled by one switch |
| 125 | (b) One socket 3 pin outlet 5 amp on independent board. |
| 126 | (c) One 3 pin socket outlet 5 amp on the same board board with other switches. |
| 127 | All as per item No.2 here in before but wiring with cables of size 4 sqmm for wiring & cables of size 4 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed. (Note : cutting chases & making good of disturbed surfaces shall be measured and paid separately). |
| 128 | S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type complete all as specified and directed. |
| 129 | S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed. |
| 130 | S&F in repairs switch socket combination 2 in 1,5 amp flush type. |
| 131 | S&F in repairs socket outlet 2 in 1, 3/5 pin 5 amp multi purpose, flush type. |
| 132 | S & F Ceiling rose, 3 way PVC insulated bodycomplete all as specified and directed by engineer in charge. |
| 133 | M&L lamp holder, PVC/ poly carbonate type with black plate suitable for batten fittings. |
| 134 | Supply and fix in replacement of LED Tube light of 18/20 watt (4\") with batten integrated channel complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.Make:BajajCAT Part No BCLAB 20W WH LED P (4ft)or equivalent to CG/Philips/Wipro complete all as specified and directed . |
| 135 | Supply and fix in replacement of LED Tube light of 10 watt (2\") with batten integrated channel complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.Make:BajajCAT Part NoBCLSB 10 WH (2ft)or equivalent to CG/Philips/Wipro complete all as specified and directed . |
| 136 | Supply and fixing new adore LED lamp 9 Watt confirming to Cat NoLHLDBWHB4L8R009 of Havell\"s or euivalent in Philips / Bajaj |
| 137 | Supply and fix Inverter Bulb LED lamp 9 Watt confirming to Cat No LHLDEGEDML8009 of Havell\"s or euivalent in Philips / Bajaj |
| 138 | Supply & fix in replacement of ,New generation energy saving and environmental friendly long life LED street ligh 60 Wattmade up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 .Make:Bajaj equivalent to CG/Philips/Wipro complete all as specified and directed |
| 139 | S&F in MCB DB SPN 4 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surfaceall as specified and directed |
| 140 | S&F in repairs MCB SPN 40 to 63 AMP,240 Volts 10KA \"C\" curve , Complete all as specified and directed. |
| 141 | S&F in repairs MCB SP 5 To 32 AMP,single pole 240 Volts 10KA \"C\" curve, Complete all as specified and directed. |
| 142 | M&L for sub main wiring drawing through PVC casing and capping with four runs of single core 4 sq mm and Four runs of 4.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts gradeall as directed.Note:- Four run of 4 sqmm wire and Two run of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter. |
| 143 | M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition. |
| 144 | Supply and installation of Earthing rods as per following specifications(a) Earthing rod, 25mm pure copper hollow Earthing Rod with strip I pipe Design Length 3m. Copper Terminal of 100x50x5(b) BFC Compound The BFC is carbide based having very high electrical conductivity. BFC having high moisture retaining capacityBFC is hygroscopic, nonmagnetic and non - corrosive in nature and in ROHS compliant (c ) InstallationThe Earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5mThe Bore drilling will be done with the help of pneumatic boring machine.]50KG BFC will be placed in the bore to cover the Earthing rod from all sides. BFC will be poured in slurry form in properly mixed condition. Earth pit cover square 300x300x240mm to be provided to cover the Earth pit.The Earth pit cover shall be made of Reinforced FRP and should be capable of carrying .The weight of 5 tones. Make : U-Protect,Ashok,JEFF Techno.Note : Electrode must be testedfor short crcuit test of minimum 40ka at CPRI/NABL 2) After installation companytesting & checked test with earth value certificate provide by contractor. |
| 145 | Supply & Fixing for copper strip 20 x 3.15mm includingwith saddles and fixing screws etc for roof conductors and down conductors above ground for earth continuityto wall on batten or recess or chases or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. NOTE: Cement cube for fixnig the strip shall be deemed to be included in qoted rates. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy