Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition Works |
| 2 | Removing tiled flooring in all types of wall tiling or flooring i.e. Shahabad, Kotah, Cement, vitrified,Marble mosaic, Glazed, Ceramic tiles etc. including scaffolding, stacking and disposal of unserviceable material with all lead and lifts as per direction of Engineer-in-charge / PMC. |
| 3 | Removing the existing cement plaster with POP/Putty of any thickness without causing dust nuisance and stacking the debris with all lead and lifts as per direction of Engineer-in-charge / PMC. |
| 4 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material with all lead and lifts as per direction of Engineer-in-charge / PMC. |
| 5 | Demolishing waterproofing/brick bat by manually/ by mechanical means including disposal of unserviceable material with all lead and lifts as per direction of Engineer-in-charge / PMC. |
| 6 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking the material and handed over to the MPCb and disposal of unserviceable material with all lead and lifts as per direction of Engineer-in-charge / PMC. |
| 7 | Dismantling old sanitary fitting & fixures of all types i.e. W.C., urinals, wash basin etc. including its pipes and stacking of serviceable materialand handed over to the MPCb and disposal of unserviceable material with all lead and lifts etc complete as per direction of EIC / PMC. |
| 8 | Removing old electrical fitting & fixtures of all types i.e. lights, fans, detectors, exhaust fan, switch, socket, equipments, switchgears, DB, and bus bar, Telephone / LAN / WAN / TV cables, FAPA etc. including its cable, wiring, piping and stacking of serviceable material and handed over to the MPCb and disposal of unserviceable material with all lead and lifts etc complete as per direction of EIC / PMC. |
| 9 | Removing all types of ceiling i.e. Gypsum, perforated ceiling tile, calcium silicate, mineral fibre etc. including stacking the material and handed over to the MPCb and disposal of unserviceable material with all lead and liftsetc complete as per direction of EIC / PMC. |
| 10 | Removing wooden, glass or A.C.partition including frame work and stacking the material and handed over to the MPCb and disposal of unserviceable material with all leads, lifts etc. completeas per direction of EIC / PMC. |
| 11 | Dismalting old existing Loose & Fixed furniture works including table, side table, workstation, chair, storeges, blinds, wallpaper, softboard, modular partition, pelmet, wooden ramp or any other item to clear the site etc including stacking the material and handed over to the MPCb and disposal of unserviceable material with all lift & leads etc. complete as per directed of EIC / PMC. |
| 12 | Removing all type of RCC works with reinforcment if required includes Slab, P.C.C. etc including concealed conduits, wiring, electrical boxes disposal of unserviceable material with all lift & leads etc. complete as per directed of EIC / PMC. |
| 13 | Removing all types ofHVAC Equipment\"s / works of any size including insulation, supports, grills with chiller pipes of any dia, ducting, stands,ncluding stacking the material and handed over to the MPCb and disposal of unserviceable material with all lift & leads etc. complete as per directed of EIC / PMC. |
| 14 | Dismantling the existing fire fighting equipment such as sprinkler hoose reel, sprinkler pipes, yard hydrant, sprinkler pump, hydrant pump,sprinkler jockey, hydrant jockey,siamese connection, breaching connection,wet riser, NRV etc including piping, wiring and storing the same including stacking the material and handed over to the MPCb and disposal of unserviceable material with all lift & leads etc. complete as per directed of EIC / PMC. |
| 15 | Civil Works includes Mansonry, Flooring, waterproofing,RCC repairs etc. |
| 16 | Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of ACC /UltraTech confirming to IS 2185 Part III 1984 of any size in extra fine jointing mortar of fixo block of Western / ACC / UltraTech in superstucture including, striking joints, racking out joints watering and scaffolding etc.complete as per directed of EIC / PMC. |
| 17 | Providing Autoclaved Aerated Concrete Block masonary of ACC /UltraTech conforming to IS:2185 (Part3) - 1984 in extra fine jointing mortar of fixoblock of Western / ACC / Ultra Tech in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete as per directed of EIC / PMC.. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) |
| 18 | Providing first class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints pointing in C.M. 1:3 and watering in pillars of rectangular or square shape as shown on the drawing or as directed etc.complete as per directed of EIC / PMC.. |
| 19 | Providing internal cement plaster 20 mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces in all positions including scaffolding, and curing complete as per directed of EIC / PMC. |
| 20 | Providing internal cement plaster 6 mm thick in single coat in cement motar 1:4 without neeru finish to concrete surface in all positions including scaffolding, curing complete as per directed of EIC / PMC. |
| 21 | Providing sand face plaster externally to concrete, stone or brick surface using approved screened sand including preparing the base, watering and applying base coat of 15 mm thk in cement mortar 1:4 using water proofing compound at the rate of 1 Kg per cement bag and curing the same for not less than two days and keeping the surface of base coat rough to recive the sand faced treatment not to exceed 8 mm thk in cement mortar 1:4 and finishing the surface by taking out grains and curing for 14 days and scaffolding etc. complete as per directed of EIC / PMC. Note: the rate shall include scaffolding. |
| 22 | Providing and fixing chicken mesh made out of 22 / 24 gauge wire with openings of 25 mm x 25mm or less as approved over junctions of RCC brickwork or any other similar materials, nailing the chicken mesh with wire nails at 200-250 mm c/c prior to plastering, all labour and materials complete as per directed of EIC / PMC. |
| 23 | Toilet & Wet Areas Waterproofing (viz-steam room, toilet, shower, kitchen etc) - Providing and Applying waterproofing and filling for Toilet & other wet areas in following parts as per the specifications listed below and as approved by the engineer-in-charge with a guarantee of 10 years : TREATMENT TO FLOOR AND WALLS:The waterproofing material to be used shall be Formdex Uniflex. It is a cementitious, two-component, polymer-modified, flexible, heavy duty, waterproofing & protective membrane. Formdex Uniflex is 100% compatable to all masonary substrates & is efflorescence free & can be applied to both horizontal and vertical surfaces.Formdex Uniflex is flexible having elongation at break 309% (ASTM D 412), Tensile strength of 1.2N/mm2 (ASTM D 412), Adhesion to substrate - 0.85 N/mm2 (ASTM D 4541), Resistance to water penetration @ 3.0kgf /cm2 (DIN 1048 - part-5), Crack bridging - passed 2mm ( ASTM C 836), Shore hardness - 78 (ASTM D 2240) & passes resistance to certaing chemicals / acids as per ASTM D 412.Cleaning the surface for treatment by removing dust, dirt etc by wire brushing & water jetting. Making Cement mortar coving at the junction of wall & floor. Providing and carrying out FORMDEX UNIFLEX two component polymer based, cementitious water proofing treatment to floor and walls of the wet areas, in two coats brush / roller applied @1.0kg/sqm/coat and reinforcing with chopped strand fiber glass mat at upturns and around detailing as per the manufacturer\"s specifications as per directed of EIC / PMC. |
| 24 | PROTECTIONSCREED TO FLOOR:Providing, mixing and laying for protection CM 1:4 screed of 15mm thick, added with integral waterproofing admixture as per manufacturer\"s specification to horizontal surface with required finish as per the direction of EIC / PMC. |
| 25 | PROTECTIONPLASTER:Providing, mixing and laying CM 1:4 Plaster 15mm thick, added with integral waterproof admixture, to vertical walls with required finish as per the direction of EIC / PMC. |
| 26 | SUNK FILLING TREATMENT:Providing, mixing and laying sunk filling with Brick bat coba with CM 1:5 of required thicknes & finishing the top layer with CM 1:4, finishing as per the direction, curing etc.complete as per the direction of EIC / PMC. |
| 27 | Flooring & Vertical wallAll surface area should cleaned up to visible of hair cracks. Cleaning of RCC member should be done by hacking tool, wire brush & air blower etc. Open cracks & construction joints should be sealed with cement mortar with additive . All clean & treated area should tested for water tighness by flooding water. All wet spots & water leakage area should mark for treatment as per the direction of EIC / PMC. |
| 28 | Providing and making 1:4 cemet mortar coving added with polymer at the junction of floor and wall etc complete as per direction of EIC / PMC. |
| 29 | If slab condition if found to be poor grouting and treatment by the followoing method will be required. Providing and applying neat cement slurry grouting including expandable additive as directed by consultants in the proportion of 1:1 by weight with the pressure grouting method by drilling and providing PVC socket pipes around the concrete surface junctions etc. and sealing the drill with Grout around the socket, to fill up cracks, fissures, cavities, void, honey comb to make substrate consistent, homogeneous and resistant to water seepage/penetration and sealing top of the socket with Grout for top 1” depth etc. complete as per the direction of EIC / PMC. |
| 30 | Grouting & Sealing around the periphery joints of pipes passing through on the floor & walls by filling Non Shrink grout micro concrete in the gap between the cut cuts in the slab & the pipe surface. etc. complete as per the direction of EIC / PMC. |
| 31 | Providing and fixing drain collar of required size around the pipe sandwitched with waterproofing membrane. etc. complete as per direction of EIC / PMC. |
| 32 | Providing and laying vitrified rustic matt stone finish tiles of Pavit, Somany, H&R Johnson of approved size and 8 to 10 mm thickness and confirming to IS.15622-2006 (GroupBla) of approved shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete as per direction of EIC / PMC.(Basic Rate of Tiles 100/Sqft) |
| 33 | Providing and laying vitrified mirror/glossy finish tiles of Pavit, Somany, H&R Johnson of approved size and 8 to 10mm thickness and confirming to IS.15622-2006 (groupBla)of approved shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete as per direction of EIC / PMC.(Basic Rate of Tiles 135/Sqft) |
| 34 | Providing & fixing in position Vitrified Tile Dado of Pavit, Somany, H&R Johnson in approved shape, thickness & colour and pattern in dado truly in plumb upto part or full height of wall with machine cut top edge as per the drawings over cement, sand. backing coat plaster of 15mm / required thickness in CM 1:4 proportion, including fixing with cement paste of required consistency to avoid any possibility of hollowness behind thetiles, filling the joints with white cement and matching color pigments including curing, scaffolding etc. complete as per drawing, specifications and as directed by the Engineer - In - Charge / PMC. (Basic Rate of Tiles 100/Sqft) |
| 35 | Granite platform top.. Providing and constructing 600 mm Wide Granite Pantry/Toilet Platform by using 18 mm thick (+/- 2 mm tolerance ) mirror polished granite stone from Floorapia, A Cube Stone World, MRM at top to be laid on marble stone base with vertical both side polished marble stone supports with marble, with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite, set in cement mortar 1:4, all exposed edges to be rounded and polished. Also providing vertical facia of granite as shown on drawing. Rate to include making opening for wash basin and pillar tap with all exposed edges polished . All joints shall be made water tight in perfect line, level & slope as desired including curing, polishing & cleaning all joints and floating in coloured cement mortar. Granite shall be of approved colour & shall be as per Architects approved lot. (Only plan area will be measured. Wastage due to dimensional difference, pattern, cutting sizes available will be to the contractors account). Rate to include all holes & openings required for fixtures and fittings. All as per drawing and instructions from Engineer in charge / PMC. SS Sink / Wash Basin to be Paid Separately . |
| 36 | Providing and fixing in position & in stepped manner one side mirror polished machine cut Granite slab from Floorapia, A Cube Stone World, MRM Jamblining for Door / Window frames / ledge wall top of width upto 350mm of 18mm thickness (+/- 2 mm tolerance) in cement mortar bedding (1:4) of required thickness. Joints, edges to be floated and finished on neat cement of the same colour as the slab. After setting, the slabs (if read) are to be machine polished at site to obtain perfect finish. All exposed edges to be rounded & polished. The rate to include all necessary chipping of brickwork / concrete so that the slab is 12mm projects from plaster / POP surface with rounding of edges, polishing etc. complete as shown on drawing & as per directions of Engineer In charge / PMC. Note: No payment will be made for overlapped portion of the jamblining. |
| 37 | Chipping the R.C.C. surface and cleaning the rusted reinforcement and exposed surface by wire brush mechanical device or any other established method and applying rust removing solution of approved make and quality with cotton waste swab to reinforcement and allowing to dry the same for 24 hours, brushing of loose particle and applying 1st coat of rust preventive coating of polymer and cement slurry in 1:1.5 proportion with soft brush without adding water including applying another coat of rust preventing after 4 hours allowing Air Curing for 48 hours etc. including scaffolding etc. complete as per directions of Engineer In charge / PMC. |
| 38 | Providing and applying priming cum bonding coat of polymer of approved make and quality as approved by Engineer-in-charge and cement slurry in 1:1 proportionate by weight to concrete area by brush or any other established method etc. complete as per directions of Engineer In charge / PMC. |
| 39 | Providing and applying 30 mm thick self curing Ceremic Polymer Microconcrete of approved make having Compressive strength above M30, nonshrink, impermeable, filling mortar to load carrying R.C.C member in two layers on cleaned concrete surface, including honeycomb area (usingmanual/mechanical means). Mixing mortar of NicosilC80 and fresh 53 grade cement with required water cement ratio for desired consistency and applying andf/ inishing by manual trawelling, curing after curing initial setting time etc,as per manufacturers specification etc. complete as per specification and as directed by engineer-incharge / PMC. Work shall be executed by certified applicator only and work shall be guaranteed for 5 years and guarantee shall be provided on Rs.500/-stamppaper. (Bondcoat mentioned below is to be done before coating) |
| 40 | Providing and laying Cast in situ/Ready Mixcement concrete M-15of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) etc. complete as per directions of Engineer In charge / PMC. |
| 41 | Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original etc. complete as per directions of Engineer In charge / PMC. |
| 42 | Providing and laying in position Granite stone flooring from Floorapia, A Cube Stone World, MRM of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete as per directions of Engineer In charge / PMC. |
| 43 | Providing and fixing machine cut machine polished Granite stone from Floorapia, A Cube Stone World, MRM of approved shade and size 18 mm to 20 mm for treads and risers of steps and staircases of approved colour and shade with full moulding, nosing and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. as per directions of Engineer In charge / PMC. |
| 44 | Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete as per directions of Engineer In charge / PMC. |
| 45 | Providing and laying matt finish ceramic tiles from Pavit, Somany, H&R Johnson of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete as per directions of Engineer In charge / PMC. |
| 46 | Providing and laying 4 mm to 6.5 mm thick PVC plank flooring of SMJ, Merino, Welspun made of 100% virgin PVC/ SPC backing with minimum 0.50 mm thick wear layer in required design and pattern in linear and curvilinear portions of the building. The planks are to be connected with glue free click connect joinery system and junction of the adjoining floors are to be finished with \"T\" or any other approved profile of aluminum/ wooden/ S.S. of approved make as per manufacturer\"s specifications. The entire work is to be completed as per the direction of the EIC/PMC. Basic rate of PVC Plank: Rs.2,500/- Per Sqmt |
| 47 | Providing and fixing double scaffolding system (cuplocktype) on the exterior side of building / structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S.tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamp sand staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and / or pointing and / or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge / PMC. Note:-(1)The elevational area of the scaffolding shall be measured for payment purpose. (2)The payment will be made once only for execution of all items for such works. |
| 48 | Providing and fixing Jute Kantan (Tarat) screen to the scaffold-ing for external guniting as directed including removing the same after the work is over etc. complete as per directions of Engineer In charge / PMC. |
| 49 | Providing and fixing mild steel grill works for window, ventilator, compound grill weight 20 kg per Sqm as per drawing including necessary fixture, weilding and painting with one coat of anti corrosive paint etc complete as per directions of Engineer In charge / PMC.. |
| 50 | Providing and erecting 1.5 m high wire fencing with seven rows of barbed wire supported on mild steel angles (50 mm x 50 mm x 6 mm) at 2.5 m centre to centre including excavating pits for foundation, fixing posts in cement concrete 1:4:8 blocks of size 45 x 45 x 45 cm, fastening the wire and painting the mild steel angles with one coat of red lead primer and two coats of painting etc. complete as per directions of Engineer In charge / PMC.. |
| 51 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete as per directions of Engineer In charge / PMC.. |
| 52 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 oftrap/ granite / quartzite/ gneiss metal for slab, columns, beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete as per directions of Engineer In charge / PMC. (Excluding reinforcement and structural steel). |
| 53 | Providing and fixing in position TMT -FE-500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules .including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete as per directions of Engineer In charge / PMC. |
| 54 | Repairs to RCC Damaged members such as slab, beam, columns and non- structural members such as chajjas, drop pardi etc. by using Readymix Polymer Modified Mortar (upto size mentioned below in mm thick). The damage member is to be chipped of loose concrete with all safety measures such as propping, protective covering. The steel exposed should be removed of loose rust from the reinforcement bars by wire brushing, ligth hammering etc. and applying sulphate and chloride free inorganic single component rust remover (Rusticide or equivalent) confirming to IS 9077. After 24 hours of application of rust remover, loose particles shall be removed by brush. Over it, bonding coat slurry of high performance acrylic polymer Polyalk EP or other euivalent in proportion of 1kg Polyalk EP with 0.5 Kg of cement to to applied for bonding of Ready mix Polymer Modified Mortar. The Polymer Modified mortar can be sprayed or trowel applied. When applying by hand it must be forced tightly into the substrate to ensure complete contact with the substrate. Work to be executed by certified applicator only and work shall be guaranteed for 5 years the guarantee shall be legally mentioned on stamp paper. |
| 55 | 25mm |
| 56 | 50mm |
| 57 | For replacing distressed/loose/ cracked/ porous carbonated, loose part of concrete with fiberous micro-concrete and repairing the damaged surface of concrete, fix the formwork / shuttering across the profile of damaged structural element, pour the free flow ready mix micro concrete withwater as per manufactures specifications in the formwork. Microconcrete should be mixed in steel tray homogeneously makeup concrete is based on type of structural element and its location. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor etc. |
| 58 | 50mm |
| 59 | Providing and laying 10,12 & 15 mm thk Vitrified Material paver tiles of Pavit Decor or Equivalent approved make in all colours and shade in flooring, skirting, dado,riser of steps, laid with includingrequiredthickness of cementmortar1:4beddingfloatedwithneatcementslurry,fillingthe joints with matching color pigment mixed with cement laid to perfect line and level & pattern. No extra payment will be made towards wastage due to material pattern & design. payment shall be made on finished floor/wall area only. Rate shall be applicable to all levels & heights etc complete as per direction of EIC / PMC. |
| 60 | Providing and Laying factory made coloured chamfered edge Cement concrete paver / grass blocks of required strength,thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over upto 50mm thick compacted bed of fine fine aggregate (natural sand/crushed sand VSI grade finely washed etc.), compacting and proper embedding/laying of inter locking paver blocks into the fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and cutting of paver blocks as per required size and pattern, finishing and sweeping extra fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and complete as per manufacturer spsecifications & direction of Engineer-in-Charge / PMC. 60mm thick CC paver block of M-35 grade concrete with approved colour and design & pattern. |
| 61 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete as per direction of EIC / PMC. (I.S. 62481979) (With mechanical gear) |
| 62 | Carpentry Works. |
| 63 | Providing and fixingin position Aluminium Frame Work of Square hollow sections of given size for partitions, paneling, boxing, soffits etc. with vertical & horizontal members at not more than 600 mm center to center. All complete including necessary additional supports, bracing, runner etc. so that lateral movement is arrested. as per instructions of Architect. Frame work will be measured and paid as per actual measurement on site. Rates quoted shall include the cost of providing and fixing supports up to ceiling. All complete as per detail drawing, as specified and as directed by EIC / PMC. |
| 64 | Size 50 x 50 x 1.62 mm |
| 65 | Size 50 x 25 x 1.62 mm |
| 66 | Providing & Fixing in position on existing frame work including all materials, labour etc complete. Item to be completed in all respects as per drawings & instructions from Engineer - In - Charge / PMC. |
| 67 | 9mm thk Marine plywood |
| 68 | 12mm thk Marine plywood |
| 69 | 19mm thk Marine plywood |
| 70 | PVC Starke Board |
| 71 | 8 mm thk calcium silicate board |
| 72 | 6 mm thk calcium silicate board |
| 73 | 12.5 mm thk gypsum board |
| 74 | 12.5 mm thk Rejection Acoustic board |
| 75 | Providing and fixing 3mm - 4mm thick group matching Decorative Veneer of approved quality and make, of required size and width as per site condition including surface preparation pasting with approved adhesive and finishing it evenly to get flat surface. The cost of openings for switches, AC Facia, any other cutout etc. shall be included in the rates quoted. complete as per detail drawing & directions by Architect. No extra payment will be made towards providing any pattern .The item includes finishing the surface with 3 or more coats of melamine polish as per the direction by EIC / PMC. (Basic Rate for veneer: Rs.225 per sft.) |
| 76 | Providing and fixing 1.5 MM thick group matching Laminate of approved quality and make, of required size and width as per site condition including surface preparation pasting with approved adhesive and finishing it evenly to get flat surface. The cost of openings for switches, AC Facia, any other cutout etc. shall be included in the rates quoted. complete as per detail drawing & directions by Architect. No extra payment will be made towards providing any pattern etc complete as per direction of EIC / PMC..(Basic Rate for laminate: Rs.55 per sft.) |
| 77 | Providing & fixing in position 460 mm deep storage / Wardrobe unit along with partitions etc with 1) sides,top,bottom shelves made out of 19 mm marine plywood 2)6 mm thk. marine ply backing panels3) Shutters made out of 19 mm thick block board &6 mm thick teakwood leaping with egde moulding of approved profile if any shall be provided in all exposed ply edge surfaces & be finished with melamine polish / PU coating.4) Finish 1mm thk laminate inside &out side as per below mention. 5) hardwares such as heavy duty hinges of size 100 x 19 x 25 mm, brass body locks(Elpro make) with extra large group key of approved quality, magnetic ball catchers, handles of dia 12mm x 128mm, towerbolt 150mm etc. All exposed woodwork to be finished with 3 coats of melamine polish / PU coating & all internal surface finished with approved 1 mm thk laminate. All as per detailed drgs and instructions of EIC / PMC. Size in front elevelation will be measured for payment. |
| 78 | Low height storage with laminate finish (LST) |
| 79 | Over head storage laminate finish |
| 80 | Full height storage with laminate finish (FST) |
| 81 | Low height storage with Veneer finish (LST) |
| 82 | Full height storage with Veneer finish (FST) |
| 83 | Full height storage with glass shutter |
| 84 | Providing and fixing glazed partition made out of 10 mm thk clear glass with designs pattern as shown in drawing. Glass should fixed with required size of teakwood / wooden beading / moulding which finished with 3 coats of melamine polish / adhesive or any other fixing material to complete the works. Rate including cost of glass edge maching etc complete as per direction of EIC / PMC. |
| 85 | Providing & Fixing of Geze Dela System GD-45S i.e.. Single glazed modular system consists of Aluminium section of 30x45x2 mm thick, with adaptable profile for 6 mm Groove system to accommodate the carpet & the uneven surfaces. All sections duly anodised up to 20-25microns with 6063-T6 grade and required accessories i.e. glass to glass aluminium I/H sections, T section & 90 degree L sections & Glass packing to adjust the floor level. Ceiling profile, Floor profile and wall profile are 30 mm visible face and 45 mm wide with 10mm tougheneded glass & insertion of Thermoplastic gasket to adhere the glass firm & airtight. The sound reduction Value is from 32 to 35 Db etc complete as per direction of EIC / PMC. |
| 86 | Supply and installation of toilet cubicles of width and depth as per specifications/site drawings. Cubicle height to be 2003 mm.Made from solid grade compact high pressure laminate as per IS:2046 and EN438- manufactured under high specific pressure > 5 MPa and temperature 120°C with bunch of kraft papers impregnated with thermosetting phenolic resin and decorative papers made of cellulose fiber impregnated with thermosetting melamine resin which provide superior scratch, abrasion, heat, chemical, impact, graffiti & moisture resistance along with anti-bacterial properties. Panels have a black core that when machined, presents a distinctive black edge.Doors:All doors will be of single colour and made of 12 mm thick HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the pilasters. Stainless steel made coat hook and door knob are provided with each door.Pilasters:All pilasters will be made of 12 mm thick HPL compact panel with chamfered edge and completed with stainless steel made thumb turn Lock set (comprised of Thumb turn and occupancy indicator). Aluminum made door stopper profiles with rubber linings for dampening the noise while door closing will be provided at the vertical ends of the pilasters. |
| 87 | Dividers:All intermediate partitions or dividers will be made of 12 mm thick HPL compact laminate panels. They are affixed with stainless steel made U-channel at their ends for ultimate stability of the system. Design no. as specified by Arch. / Engr. in suede finish. Size of panels to be as per drawing.HARDWARE & ACCESSORIES • Semi-spherical (Top) head frame structure for surface protection. Size to be 50mmx32mmx1.8mm.• Corner joinery section, Size to be 40mmx16.5mmx1.8mm. • U-Channel Wall joinery section, Size to be 22mmx16mmx1.8mm. Door stopper section, Size to be 21mmx12.5mmx1.6mm. • Adjustable Palm Design Pedestal Footing of base diameter 60mm made from Stainless steel grade 316 giving a clearance height of 150 mm. Surface finish to be Lacquer type. • Spring loaded Butt Hinges made from Stainless steel grade 304. Surface finish to be matt type. Covers to be lacquer coated. • Coat hook with rubber stopper made from Stainless steel grade 304. Surface finish to be lacquer type. • Round Door knob diameter 30 mm with grooves for better hand grip made from Stainless steel grade 304. Surface finish to be lacquer type. • Rotating Thumb-turn locking system with privacy indicator made from Stainless steel grade 304. Surface finish to be lacquer type. • Stainless steel grade 304 screws.• Anti-rotation Nylon polyamide grade6- expandable wall plugs.• The Work shall complete as per drawing, under supervision of engineer in charge and company experts • Extruded grade aluminum alloy and epoxy powder coated (color as per specifications): |
| 88 | • Stainless steel grade 304 screws.• Anti-rotation Nylon polyamide grade6- expandable wall plugs.• The Work shall complete as per drawing, under supervision of engineer in charge and company experts • Extruded grade aluminum alloy and epoxy powder coated (color as per specifications):Toilet Cubicles:Std Sizes : Std Sizes W x D x H): 900 mm x 1550 mm x 2003 mm, (Height is including 150 mm gap from bottom) Door Width- 610 mm |
| 89 | Supply and installation ofPD DOOR series cubicles of width and depth as per specifications/ site drawings. PD Door height to be 1980/2100mm.DoorMade from solid grade compact high pressure laminate as per IS:2046 manufactured under high specific pressure > 5 MPa and temperature 120°C with bunch of kraft papers impregnated with thermosetting phenolic resin and decorative papers made ofcellulose fiber impregnated with thermosetting melamine resin which provide superior scratch, abrasion, heat, chemical, impact, graffiti & moisture resistance along with anti-bacterial properties. Panels have a black core that when machined, presents a distinctive black edge. Panel thickness 12mm. Design no. as specified by Arch. / Engr. in suede finish. Size of panels to be as per drawing. |
| 90 | HARDWARE & ACCESSORIES • Specially designed D-shape wall mounted pole made from extruded grade aluminum alloy 6063/HE9/T-6 and epoxy powder coated (color as per specifications) for surface protection. Size to be 46x41x2T. • Matching profile and color Nylon Polyamide-6 caps to cover aluminum Poles.• Self closing Hinges (Gravity mechanism) made from Nylon Polyamide grade-6. Color to be as per specifications.• Round Coat hook with base diameter 53mm made from Nylon polyamide grade-6. Color to be as per specifications.• Round Door knob diameter 48mm with thumb-recess made from Nylon polyamide grade-6. Color to be as per specifications.• Latch locking system with privacy indicator made from Nylon polyamide grade-6. Color to be as per specifications.• Anti-noise rubber padding.• SS grade-304 screws.• Anti-rotation Nylon polyamide grade-6 expandable wall plugs etc complete as per direction of EIC / PMC. |
| 91 | PD Doors Series :Std Sizes(H x W): 2100mm x 750mm(Height is including 150mm gap from bottom) |
| 92 | Supply & Installation of 3M Fasara pre-patterned, polyester with UV resistant clear adhesive, installation to be done on clean glass, by Authorized Installers only. 3M Architectural Markets Warranty for a period of 60 months for interior application, 12 months for exterior application to be submitted along with invoice etc complete as per direction of EIC / PMC. |
| 93 | Providing and fixing thermal/acoustic insulation with Resin Bonded Fibre glass wool conforming to IS : 8183 having density 32kg/cum, 50mm thick wrapped in 200G Virgin Polythene bags placed in between partitions and wall panelling and held in position by criss-crossing GI wire. It should be ensured that the fibre glass wool is wire-braced (chicken mesh) to prevent it from ‘lumping down’ over a period of time. The actual surface area of the insulation only will be measured for payment etc complete as per direction of EIC / PMC. |
| 94 | Painting Works |
| 95 | Providing and applying plaster/wall punning with plaster of paris (with plaster of paris material of Ambuja/MorChap or equivalent make) in 10 to 13 millimeter thickness to previously plastered surface/or on newly bricksurface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc.complete as per direction of EIC / PMC. |
| 96 | Providing and applying plastic emulsion paint conforming to IS:5411-1991 part I of superior quality of approved make, colour and shade to the old & new surfaces in two coats over primers, including scaffolding, preparing the surfaces to receive the paint and applying putty etc. complete as per direction of EIC / PMC. |
| 97 | Providing and applying three coats white/colour wash on old and new plastered or masonry surfaces or concrete surface and asbestos cement sheets conforming to IS:6278-1991 including scaffolding and preparing the surface by brushing and brooming etc. complete as per direction of Engineer - in charge / PMC. |
| 98 | Providing and applying two coats of Exterior Acrylic paint of approved make and of approved colour to the plastered surfaces including cleaning, prepairing the plaster surface ,applying primer coat as per manufacturer\"s specifications, , scaffolding if necessary, etc.complete.Providing and applying two coats of Exterior Acrylic paint of approved make and of approved colour to the plastered surfaces including cleaning, prepairing the plaster surface ,applying primer coat as per manufacturer\"s specifications, , scaffolding if necessary, etc.complete as per direction of Engineer - in charge / PMC. |
| 99 | Providing and applying TEXTURED paint of approved colour & shade to old and new surface including scaffolding preparingthe surface to finishing with 2 coats etc complete as per direction of Engineer - in charge / PMC. |
| 100 | Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) etc complete as per direction of Engineer - in charge / PMC. |
| 101 | Providing & Applying superior quality of Zinc coat wall texture Paint of approved make & shade, using roller to get approved textured surface in 3 or more coats including preparation of surfaces, applying cement primer of approved make & shade etc. complete as per directed of Engineer - in charge / PMC. |
| 102 | Providing and applying two coat of synthetic super enamel paint of approved colour to new / old structure steel work including scaffolding if necessary and cleaning and preparing the surface by solvent, degreasing and derusting by manual scraping / mechanically by sand blasting / shot blasting flame cleaning / by chemical methods completeincluding primer coat etc. complete / PMC. |
| 103 | Doors & Windows Works |
| 104 | Providing and fixing best quality superior Indian teak wood frame for doors, windows and ventilators including all moulding, rebating, jointing, hold fasts of MS flats of minimum size 20 x 3 mm, having length of 225 mm for doors & 150 mm for windows and finishing with 3 coats of French polish or one coat of primer and synthetic enamel paint in two coats as directed etc. complete. |
| 105 | Providing & Fixing of Geze Dela Partition System Stile Door having size of 75x40 with door profile GD-75T ie. 6063-T6 Virgin grade duly Anodized Aluminium Door Sections having sizes of 75x30x1.5mm thick,, 10 mm tougheneded Glass including Geze make Door Closer TS3000V, 4nos Flush Hinges, SS Offset D type Pull Handle 25 x 450mm with narrow Stile Dead lock, Door Seal & Gaskets etc complete as per detail drawing as specified & as directed by Engineer-incharge / PMC.Finish:BlackSingle Swing Door Size: 900 x 2400mm |
| 106 | Providing & Fixing of Geze Dela Partition System Stile Door having size of 75*40 with door profile GD-75T ie. 6063-T6 Virgin grade duly Anodized Aluminium Door Sections having sizes of 75x30x1.5mm thick, 10 mm tougheneded Glass including Geze make Door Closer TS3000V, 8 nos Flush Hinges, SS Offset D type Pull Handle 25 x 450mm with narrow Stile mortise Dead lock, Flush Bolt, Door Seal & Gaskets etc complete as per detail drawing as specified & as directed by Engineer-incharge / PMCFinish:Black (Double Swing Door Size: 1800 x 2400mm) |
| 107 | Providing & fixing door in position 48mm thk Partly Glazed Partly Solid door shutter of 45mm thk. door shutter finish with 1.5mm thk. Laminate on both sides with 12mm thk toughened glass panel approved beading, grooves, approved moulding, lipping patti including necessary hardware, approved adhesive, fitting & fixture Handel, Lock, Floor Spring/door closer, door stopper, tower bolt, hinges etc. melamine polish to all exposed surfaces etc complete as per detail drawing as specified & as directed by Engineer-incharge / PMC. (48mm thk =1.5 + 45 +1.5 mm thick Laminated Flush doors). Note - The rate of hardware will be paid seperately. |
| 108 | Providing & fixing 50.5mm thk. Flush door finish with one side 1.5 mm thk. Laminate and one side 4 mm thk Veneer as per approved pattern, moulding, beeding. All edges should finish with teak wood lipping with melamine polish. All complete as per instructions & approval of EIC.Hardware such as door handles, hinges, door closures/floor spring, dead lock, PVC door buffer , door stopper, tower bolt, latches etc. complete as per detail drawing as specified & as directed by Engineer-incharge / PMC. (50.5mm thk =4mm thhk veneer + 45 +1.5 mm thick Laminated Flush doors). Note - The rate of hardware will be paid seperately. |
| 109 | Providing & fixing door in position Solid Flush door shutter of 45mm thk. door shutter finish with 1.5mm thk. Laminate on both sides with approved beading, grooves, approved moulding, lipping patti including necessary hardware, approved adhesive, fitting & fixture Handel, Lock, Floor Spring/door closer, door stopper, tower bolt, hinges etc. melamine polish to all exposed surfaces etc complete as per detail drawing as specified & as directed by Engineer-incharge / PMC. (48mm thk =1.5 + 45 +1.5 mm thick Laminated Flush doors). Note - The rate of hardware will be paid seperately. |
| 110 | Providing & fixing door in position Solid PVC Starke board door shutter of 30mm thk. door shutter finish with 1.5mm thk. Laminate on both sides with approved beading, grooves, approved moulding, lipping patti including necessary hardware, approved adhesive, fitting & fixture Handel, Lock, Floor Spring/door closer, door stopper, tower bolt, hinges etc. melamine polish to all exposed surfaces etc complete as per detail drawing as specified & as directed by Engineer-incharge / PMC. (33mm thk =1.5 + 30 +1.5 mm thick Laminated Flush doors). Note - The rate of hardware will be paid seperately. |
| 111 | Providing & fixing 45mm thk. Flush door finish with 4mm thk. Veneer on both sides as per approved pattern finish with polish, moulding, beading patti etc. All edges should finish with teak wood lipping with melamine polish. All complete as per instructions & approval of EIC. Note: The rate of all doors shall exclude all hardware such as door handles, hinges, door closures/floor spring, dead lock, PVC door buffer, door stopper, tower bolt, latches etc. as required. |
| 112 | 2 Hour Insulated, Flame, Smoke Radiation check Lead Lined Fire Door 57mm 2HR FRL (120/120) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. with prior approval of concerned Superitending Engineer |
| 113 | Providing ofmake 120 min Fire rated lead lined doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 with standard \heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology (\"Non Combustible by Nature\"). Lead lined to check radiation. Code No; 2 Hour Insulated, Flame, Smoke Radiation check Lead Lined Fire Door 57mm 2HR FRL (120/120) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2.Door Frame: Providing Frames for Lead Lined Fire resistant door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 140 X 70 mm with 45mm thick two layered 3mm Lead Line Sheets with 10mm overlap from either side & spray quoted with 2 coats of In tumescent paint of minimum 200 micron, with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed in the groove of the Frame for fire and hot and cold smoke sealing, etc. complete as per direction of Engineer in Charge / PMC. |
| 114 | Shutter - : Providing of 57mm thick asbestos free composite, \"TUFWUD\" brand - 3 criteria - fire, heat and smoke check Lead Lined Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9mm Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x30 mm with 30mm thick infill of ceramic fibre (density 128 Kgs/CMT) vermiculite mix, 3mm thick Lead Sheet on one side faced & 3mm Fire retardant High Density Fibreboard, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of Intumescent paint of minimum 300 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping etc. complete as per direction of Engineer in Charge / PMC. |
| 115 | Providing & fixing vision panel of 1 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside the shutter structure with 10 mm inside the shutter on all sides with Uglazing. An additional insulated powdercoated \"Z\" channel of 16 swg MS sheet to be fixed for reinforcement of the joints. With clear fire resistant glass panes 11mm thick having minimum 120 minutes fire Description etc. complete as per direction of Engineer in Charge / PMC. |
| 116 | Providing & fixing Trap Doors made out of required framework, 19mm thk plywood finished with material 1.5 mm thk laminate from outside and 1mm thk laminate from inside. Site modification as per requirement has to be undertaken without any extra cost etc complete as per direction of Engineer in Charge / PMC. |
| 117 | Providing and fixing of factory made uPVC Sliding window & door complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 \"P\" Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be fusion welded. After placing 12 mm toughened glassin in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. |
| 118 | Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use etc complete as per direction of Engineer in Charge / PMC.3 Track with Mesh- 2 or 3 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm. (Note Glass sash depend as per site condition) |
| 119 | Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 \"P\" Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. |
| 120 | uPVC Window and Door Profiles are warranted for a period of ten (10) years against non- uniform discoloration,wrapping and rotting under general use etc complete as per direction of Engineer in Charge / PMC.a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm. |
| 121 | Providing and fixing mild steel grill work for window, ventilator weighing 20 kg per Sqm. As per drawing including necessary welding and painting with one coat of Red Oxide Zinc Chromate primer and two coat of synthetic enamel paint etc complete as per direction of Engineer in Charge / PMC. |
| 122 | Providing and fixing in position 12 mm thick Toughened Fully Clear Glass Door by using various glass patch fittingsto be fixed with necessary fittings on the ceiling duly finished without giving any load on the false ceiling by using necessary hardwarewhat ever necessary and required numbers to complete the job in all respect. Rate including cost of door with approval hardware such as patch fitting lock, handle, Floor Spring of approved make. Contractor is advised to submit working drawing with detailspatch fitting, sizes of glass panels etc and take approvals of consultants before execution of works. complete as per detail drawing, as specified and as directed by Architect. |
| 123 | Providing and fixing MS collapsiable gate with black enamel pint for main door icluding cost of all materials and laboures etc compelete as per direction of Engineer in Charge / PMC. |
| 124 | Supply and fixing of Two ball bearing flat button hinge with screws No.8 x 32mm for wooden doors Size : 4\"x3\"x3mm Material : Stainless Steel 304 Finish: Satin as per manufacturers specification and as directed by the Engineer in Charge (GEZE 98850001/DORMA 3090F/ ASA ABLOY) |
| 125 | Supply and fixing of Patch fitting Set 1 for frameless single glass door consisting of: Bottom patch with satin SS cover, Top patch with satin SS cover, Top pivot plate Bottom lock, w/o cylinder with satin SS cover with Lock keeper plate, PC Profile Cylinders, L=60mm, 3 Keys(GEZE/ DORMA /ASA ABLOY) PL/PL 10,20,30,40,50 etcas per manufacturers specification and as directed by the Engineer in Charge |
| 126 | Supply and fixing of GEZE TS 3000V/DORMA TS92/ASA ABLOY DC 500 Asymmetric Rack and Pinion Door Closer with slide arm, EN1154, CE Marked, With Hold-open, EN2-4 Size, Spring Adjustable, suitable for doors of 850-1100mm, with variable closing and latching speeds. Supplied complete with templates, screws for fixing and accessories as per manufacturers specification and as directed by the Engineer in Charge |
| 127 | Supply and fixing of GEZE 98163016, Dorma TGDID 300x22, ASA ABLOY) Pair of D type Stainless steel 304 pull handle size 22 x 300mm includes Stainless Steel back to back fixing accessories for Glass/Metal/Wood door. Supplied complete with templates, screws for fixing and accessories as per manufacturers specification and as directed by the Engineer in Charge. |
| 128 | Supply and fixing of (GEZE 98163105, DORMA TGDIH, ASA ABLOY) Pair of H type entrance pull handle made of SS304 with SSS finish, back to back fixing, suitable for Glass/Metal/Wood door of 38-55mm thickness, total length of 1000mm with CTC of 1000mm and 25mm dia . Supplied complete with templates, screws for fixing and accessories as per manufacturers specification and as directed by the Engineer in Charge. |
| 129 | Supply and fixing of 52mm dia with 38mm fixing centers supplied with stainless steel structure 8mm thick (GEZE 168501/ Dorma 6612/ ASA ABLOY) 5 pin Euro profile knob cylnder with 3 keys, 70mm length ( GEZE 9168501/ DORMA 3515/ASAABLOY) |
| 130 | Supply and fixing of( GEZE, DORMA, ASA ABLOY) Rectanglular Flush pull,Size: H102mm x W45mmMatrial: Stainless. Rectangular Concealed flushpull made of SS304 with SSS finish, self fixing. Supplied complete with templates, screws for fixing and accessories as per manufacturers specification and as directed by the Engineer in Charge. |
| 131 | Supply and fixing of GEZE / Dorma / Assa Abloy Yale Dead bolt for access door (Shaft Door) Shaft Lock. Supplied complete with templates, screws for fixing and accessories as per manufacturers specification and as directed by the Engineer in Charge. |
| 132 | Supply and fixing of GEZE 98536301/DORMA PHA/ ASA ABLOY Single point panic device for single leaf door. Fire tested Suitable upto 1200mm width Door. Supplied complete with templates, screws for fixing and accessories as per manufacturers specification and as directed by the Engineer in Charge. |
| 133 | Supply and fixing of GEZE 98536302/ DORMA PHT 05/ ASA ABLOY External Trim for Panic device. Supplied complete with templates, screws for fixing and accessories as per manufacturers specification and as directed by the Engineer in Charge |
| 134 | Supply and fixing of GEZE/DORMA/ASA ABLOY SS 304 Lever action Flush Bolt with 19mm projecting bolt. Length 600mm for Steel / wooden door in satin chromefinish. Supplied complete with templates, screws for fixing and accessories as per manufacturers specification and as directed by the Engineer in Charge. |
| 135 | Supply and fixing of GEZE / Dorma / Assa Abloy Yale Standard half moon door stop with black rubber and in SSS finish, 45mm dia. Supplied complete with templates, screws for fixing and accessories as per manufacturers specification and as directed by the Engineer in Charge. |
| 136 | Supply and fixing of GEZE TS500NV, DORMA BTS 75, ASA ABLOY Double action hydraulic floorspring EN1154 certified, EN2-4 size, suitable for 850-1100mm door size and 150 kgs door, CE marked, fire rated for 2 hrs, spring adjustable with varibale latching and closing speeds, SSS finish cover plate and standard german spindle. Supplied complete with templates, screws for fixing and accessories as per manufacturers specification and as directed by the Engineer in Charge |
| 137 | Providing &fixing Dust proof socket - SSSwith screws for fixing and accessories as per manufacturers specification and as directed by the Engineer in Charge |
| 138 | Providing & fixing Automatic sliding door of GEZE ECdrive T2 for double leaf sliding door application (Max passage width upto 3000mm, Max leaf weight 2 x 120Kgs) - standard version, without radar1Pc xGEZE EC Drive T2 VP-Kit, 1Length xRunning Track ProfileEC Drive T2 L=3200mm EV1 finish, 1Length xModule carrier Profile Left =360mm and Right= 895mm EV1 finish, Cover profile for EC DriveT2 L=3200mm EV1 finish, 1Pc xEnd cover for EC Drive T2, 1Length xToothed belt, 7mts, 1 Pc X Mechanical Program Switch (MPS) flush mounted, with knob, 1Pc xSurface mount box for MPSStablizer for Automatic Control unit. ECdrive T2 Accessories for Frameless glass door, single leaf, 12mm glass thickness consisting of: 1Pc x DoorSuspension, 1Pc xAdjustable floor guide for glass doors, 1Pc xclamping Rail, outside 1500 mm, 1Pc xclamping Rail, inside 1500 mm, 1Pc xESG Top Clamp Rail 300 mm, 1Pc X Glazing gasket for 12mm glass 1000mm. GEZE combined detector GC 363 RCombined detector for the activation and protection of automatic sliding doors. EM Lock & Key switch - Single/Double Door application (Security application) (per set) |
| 139 | False Ceiling Works |
| 140 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. |
| 141 | Providing and Fixing Soft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular) Edge Tiles of size 15mm Exposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ?85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 66% GW and 74% RW. The tile shall be laid on precoated G.I channel 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7 Kilograms/M2 with a minimum pull out strength of 100 Kilograms. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. |
| 142 | Providing & Fixing horizontal level suspended ceiling comprising of Knauf GI Microlook Lay-in Plain metal ceiling consisting of 600x600mm (Nominal Size) Lay-in tiles of 120 gsm galvanized steel as per IS 277 (2003) suitable for architectural finishes in 0.5 mm thickness as per IS:513 (1994) in Global white color with Square Tegular/Microlook 90˚ edge having 8mm drop and 5.5mm flange. The difference between the 2 diagonal dimensions of the tile to be less than 1mm. Tiles shall be flattened by precision leveller to minimize sag to less than 1/400mm. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000 hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000 hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E<1 using Excite/BYK Gardner instrument and gloss level 25±5% at 60˚ as per ASTM D523. The tile shall have a Light Reflectance of ≥ 63% in accordance with ASTM 1477-98 and Fire Performance of Class 0/1 as per BS 476 Part 6 & 7 in module size of 600x600mm. All border cut tiles shall be laid, using Knauf lay-in end cap for installation to have a Microlook effect on perimeters. |
| 143 | Providing and Fixing horizontal level suspended metal ceilings comprising of Metalworks C-Plank system manufactured by Knauf Ceiling Solutions with Rectangular planks made of Aluminium (Grade AA 3xxx, H14 temper) in coated thickness of 0.7mm ± 0.03mm as per IS:2676 (1981), post coated to Wood Finish, suitable for architectural finishes and Interior applications, with double grid concealed system and butt joint planks. The plank width shall be 300mm (nominal), length ranging from 600mm to 3000mm. The plank shall have plain unperforated finish with bevel edge of suitable profile. The plank shall be electrostatically powder coated using RoHS compliant pure polyester powder to achieve coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E<1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. The grids shall comprise carrier bar of 120gsm galvanised steel (GI) slotted profile of 3000mm L x 62mm H x 30mm W x 1.0mm T. Accessories shall include Carrier bar splice. (GI), Carrier bar hanger (GI), spring clamp (Spr. St.), wall anchor (GI), extruded Alu RA4F wall angle (1.2mm T) in Global White color, and pressure spring. |
| 144 | Providing and fixing Wooden rafter or ceiling at all height including providing and fixing of aluminium frame work and rafter made up of ply using9/12/19 mm with complete hardware fitting etc complete as per direction of Engineer - in - charge |
| 145 | Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, |
| 146 | all as per manufacture’s specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame along with trap doors wherever required of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with: 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process |
| 147 | Miscellaneous Works |
| 148 | Supplying, Providing & fixing in position upto 350 mm wide laminate finish pelmets / jamblining made out of 19mm thick marine plywood finished with approved finish mention below and 3 coats of French polish for inside surface as per the direction by Architect. Item to be completed in all respect as per the drawing & instruction from EIC / PMC. |
| 149 | Supplying, Providing & fixing in position upto 350 mm wide Veneer finish pelmets / jamblining made out of 19mm thick marine plywood finished with approved finish mention below and 3 coats of French polish for inside surface as per the direction by Architect. Item to be completed in all respect as per the drawing & instruction from EIC / PMC. |
| 150 | Providing and fixing in position 12mm thk soft board panelling with approved adhesive, partition surface including fabric cover, wood beading finished with melamine polish of approved shade etc. complete as per drawings & directions by EIC / PMC. |
| 151 | Providing & arranging in position dust bins out of perforated(min Size 350 mm dia x 400 mm Height). Item to completed in all respect as per drg & directions of EIC / PMC. |
| 152 | Providing and fixing BLACKOUT Fabric with composite material of High Tenacity Polyester Yarn Fabric with PVC Coating & Fungistatic Treatment of Hunter Douglas,B99 Serge Ferrari,MAP,Softlite Impex,Mado approved makemanual Roller blinds with end brackets, components, bottom bar & fabric with manual operation and warranty of minimum 5 years and Greenguard Certificate – UL 2818 Gold Certificationas per specifications. Fabric to be as per approved sample. manual system to include chain ball operation.Composition: 39% Polyester / 61% PVC,Weight: 540 g/m2 (+/-5%),as per Fungistatic Treatment: Degree 0, Excellent (EN ISO 846-A)Fire Retardancy:B1/DIN 4102-1,METHOD 2/NFPA 701,EuroCLASS B-s2,d0,Reflection solar radiation: 25% to 69%, Solar Absorption: 28%-31%,Solar Transmission-0%,Tensile Strength (Wrap/Weft)-160/170 daN / 5cm,Quality Management 1SO9001. All complete as per approval of designer & instruction of Engineer-in-charge / PMC. |
| 153 | Providing, fixing, applying by Company Trained Technicians, premium Wall Covering (WallFabric), as per details in attached specifications, or as per detailed specifications and colours attached, or approved equivalent, of approved colour, texture and design, including base and sub-base preparation(on top of existing P.O.P surface), all complete, in a neat and workman like manner, as per directions of Engineer-In-Charge / PMC. |
| 154 | Providing & fixing Artificate / Picture frame like Artifical Picture Frame, murals etc. as per shown in drawing & manufacturers specification etc complete as per direction of EIC / PMC. |
| 155 | Providing and fixing in position 25 x 50 mm mouldings out of T.W Moulding complete as per profile given in the detail drawing or as explained out of wooden sections of sizes given below. All should be finished with melamine polish of approved shade & color with minimum 3 coats. This item will operate only for those mouldings which are to be fixed independent of any other item as mentioned in the Bill of Quantities and not measured under any other item etc. complete as per detail drawing, as specified and as directed byEIC / PMC. |
| 156 | Providing and fixing in position 50 x 50 mm mouldings out of T.W Moulding complete as per profile given in the detail drawing or as explained out of wooden sections of sizes given below. All should be finished with melamine polish of approved shade & color with minimum 3 coats. This item will operate only for those mouldings which are to be fixed independent of any other item as mentioned in the Bill of Quantities and not measured under any other item etc. complete as per detail drawing, as specified and as directed byEIC / PMC. |
| 157 | Providing and fixing composite material of High Tenacity Polyester Yarn Fabric with PVC Coating, Aluminium Backing, & Fungistatic Treatment of Hunter Douglas,Serge Ferrari,MAP,Softlite Impex,Mado approved makemanual Roller blinds with end brackets, components, bottom bar & fabric with manual operation and warranty of minimum 5 years and Greenguard Certificate – UL 2818 Gold Certification as per specifications. Fabric to be as per approved sample. manual system to include chain ball operation. Composition: 39% Polyester / 61% PVC with Aluminium Backing,Weight: 290 g/m2 (+/-5%) as per Fungistatic Treatment: Degree 0, Excellent (EN ISO 846-A)Fire Retardancy:B-s2,d0/EN 13501-1, CLASS A/ASTM E84., Color: as per selected color Openness factor: 3%, Reflection solar radiation: 9% TO 65%, Light transmission: 2%-4%,Solar Absorption : 22% - 88%,Solar Transmission-3% -13%,Tensile Strength (Wrap/Weft)-160/170 daN / 5cm.All complete as per approval of designer & instruction of Engineer-in-charge / PMC. |
| 158 | Providing, Suppying & Installing of Mobile Storage System consisting of -:1) 4 Nos. of Mobile Unit Double face each of size Length 1830mm x Width 800mm x Height 2150mm.2) 1 Nos. of Mobile Units Single face each of size Length 1830mm x Width 457mm x Height 2150mm.3) 1 Nos. ofFixed Units Single face of size Length 1830mm x Width 457mm x Height 2150mm.The system will be of Knock Down System, Unit will have 5 Nos. adjustable shelves. The unit to have mechanical assisted drive. The whole system should be made of various component each of them should be treated by antirust treatment before applying the approved coloured powder coating. The whole system should be as per the approved drawing and detailed specification mention in the tender document with 12 months Guarantee. The rates coated should be inclusive of all taxes, freifgt and transportation etc complete as per direction of Engineer - in - charge. |
| 159 | Proving and applying pest control services including manpower, equipments and cosumable chemical on 7th floor Rear Wing complete as per directed and scope of work etc complete as per direction of Engineer - in - charge / PMC. |
| 160 | Removing of existing unit & Re - Installing of Mobile Storage System in Record room with all leads and lifts consisting of -:1) Mobile Unit Double face 2) Mobile Units Single face 3) Fixed Units Single face Unit will have 5 Nos. adjustable shelves. The unit to have mechanical assisted drive. The whole system should be made of various component each of them should be treated by antirust treatment before applying the approved coloured powder coating. The whole system should be as per the actual site visit done by agency, approved drawing and detailed specification mention in the tender document with 12 months Warranty. The rates coated should be inclusive of all taxes, freifgt and transportation etc complete as per direction of Engineer - in - charge. |
| 161 | Structural Glazing (Building Façade) |
| 162 | Providing, supplying, fabricating and fixing panel of aluminium composite panel cladding in approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core following NBC part 4 Fire and Life Safety (having 2 hours fire resistance in accordance to ASTM E119-12 and EN13501-1 Class B S1 D0) sandwiched between two Aluminium sheets (each 0.5mm thick of AA3105/AA5005 grade). The Aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF/Lumiflon based fluoropolymer resin (having 70:30 ratio of PVDF and Acrylic) coating of approved colour and shade on top face and polymer (Service) coating on bottom face as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods, aluminium frame etc. Overall weight of the ACP shall not be less than 7.5Kg per SQM. Installation of ACP panels will be done by recommended Aluminum T section of 100x50x2 mm thick and L section 50x50x2mm thick held by Aluminum Wall Bracket with Wind load and Dead load slot as per design, anchored by standard anchor fasteners etc complete as per direction of EIC / PMC. |
| 163 | Supply and Installation of High Pressure Laminate of 6mm thick Exterior grade F- Quality panels of standard size with both side décor . The Panels shall be perforated as per the design of the Architect. FunderMax Exterior panels are duromer high pressure laminates (HPL) as per EN 438- 6 type EDF manufactured with norm conformity of EN 438-7 using patented NT Technology (NT is Non fading high performance acrylic polyurethane surface Technology). Panels will be double hardened including acrylic polyurethane resin and thermally cured under high pressure. These Panels will have CE-Mark necessary for their use in building applications. Installation of FunderMax panels will be done by MBE Rivets (with Fixed and Sliding Points) with recommended Aluminum T section of 100x50x2 mm thick and L section 50x50x2mm thick held by Aluminum Wall Bracket with Wind load and Dead load slot as per design, anchored by standard anchor fasteners along with Thermal Separator. Installation of FunderMax Panels will be done using Rear Ventilated Principles only, which is ensured by providing ventilation gap minimum 200 cm2/ per Meter (for free flow of air behind the façade) for the façade and using the framework with no horizontal section etc complete as per direction of EIC / PMC . |
| 164 | Designing, Fabricate, and installation of Glazzio UnitizedStructural Glazing system comprising ofMale & Female mullion , Transom, Head and Cill with Andoised finish of 20 Micronscoatings (Colour as per architect intent).The male / female mullions and transoms are installed on MS (HDG) brackets preinstalled at site to the slabs (As indicated in the concept drawing) with the help of base line provided by the Main contractor at all floor level and later using Total station or Theodolite these points are shifted at all floor levels and brackets are aligned at each floors to plumb.The System and glass shall be designed to withstand a wind pressure of 1.5 kpa. and deflection L/175 at specified levels,elevation & heights.The unitised system is designed to have internal drainage system within the extruded sections.In this system cut to size and fabricated insulated glass units are glazed into the aluminium framing members at factory using structural sealant along with all necessary hardwares and later transported as final product to site.All fixtures, as Anchors, Nutbolt, and Screws shall be SS304 grade,all other accessaries as spacer tape, Structural/ Weather silicone (dow corning / G.E.SILICONE) of approved make, withEPDM gasket.System includding with all necessary hardwares labors etc.fully glazed panel to be installed at site etc. complete as per drawings & directions by EIC / PMC. |
| 165 | Note-1 :The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL (National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable seperately. Performance Testing of structural glazing system ( Tests to be conducted in the NABL certified laboratories):1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr“2. Static Water Penetration Test. (50pato 1500pa) as per ASTME- 331-09 testing method for a range upto 2000 ml.“3. Dynamic Water Penetration (50pato 1500pa) as per AAMA 501.01-05 testing method for a range upto2000 ml“4. Structural Performance Deflection and deformation by static air pressure test ( 1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm“5. Seismic Movement Test (Upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test“ |
| 166 | Providing & fixing 24mm thk DGU vision glass panel of(SAINT GOBAIN, ASAHI, PILKINGTON )1) 6mm Low e double silver coated glass HS+12mm Air Gap (Mill Finish Spacer with 6mm Silicon Byte)+6mm Clear HS. 2) Glass should mandatorily have the below properties: VLT> 45%, Solar Heat Gain Coefficient (SHGC)<0.263) All glasses both performance and clear glasses should have iron content levels of less than 700 PPM and shall strictly adhere to this quality standard 4) The glasses should follow the below thickness tolerances for different glass thicknesses5mm & 6mm: +/-0.2 mm completed in all respect as per drg & directions of EIC / PMC. |
| 167 | Designe, Supply and install Suspended spider glazing systems customm designed. The design shall accommodate glass panel of 21.52MM thk. laminated Clear toughened glass (10mm clear + 1.52 pvb + 10mm clear glass) and its dead load. The spider fittings on glazing system shall be of Stainless steel spiders OZONE/DORMA/DLCO/KINGLON/GEZE with flat head bolt assembly supported on ss structure to be made the cost is include the ss structure for support. etc complete as per direction of Engineer - in - charge |
| 168 | Providing and fixing of Sun Control System of Luxalon SL-2 Louvers or equivalent (at all heights, levels, and locations as directed) in 84R Plain Panel hunter douglas or equivalent of approved colour consisting of panel 84 mm wide x 16mm deep x 0.6mm thick with round edges panel Panels shall be clipped at a distance of 74 mm to baked enameled Aluminium SL-2 panel stringer 38mm wide and 98mm deep x 0.95 mm thick in a standard length of 5mtrs made of double baked enameled Aluminiu m Alloy white to hold the panel in a module of 74 mm centre to centre. The prongs on SL-2 stringers shall be to accommodate an angle of 66.30 Degrees between two panels. SL-2 stringers shall be fixed at 150 mm from panel ends and at a distance of maximum 600 mm center to center across the panel span from glass level. The carrier shall be fixed to a suitable structure by means of rigid fixing details. as per approved shop drawing and specifications and as directed by the Engineer - in - Charge, the sun pergola will be glass panel grid to be finalise maximum to 1200mm the depth of supergola will be maximum 700mm as per drawings approved. The alumnium box framing to be done to hold sun pergola is inclusive in the cost.. All complete as per approval of designer & instruction of Engineer-in-charge / PMC. |
| 169 | Design, Providing, fabricate and installation of GRC Panel Cladding system to withstand the wind pressure 1.5 KPA. The anchor fasteners will be of SS grade and the MS HDGL brackets will be used as per the grid level. The design shall accommodate the building movements, thermal movements and seismic movements. The GFRC panel thickness will be up to 50mm thk. All as per detailed drawing and instruction of Engineer – in - charge. Any M.S. structure required behind the, system will be included in same item. as per directions of Engineer-In-Charge / PMC. |
| 170 | Providing & fixing Top hung Openables with Structural Glazing to comprise of heavy duty friction stay (Cotswol, Giesse, Securistyle, kinglong)to take the load of glass and frame with minimum Four point lockingsystem or more as per requirement (Alualfa, Giesse, Securistyle, kinglong). etc complete as per direction of EIC / PMC. |
| 171 | providing, supplying and fixing smoke seal Supplied by International 2 Hour Fire Rated Product from SIDE - RISE - UK- with complete Installation on each floor etc. complete as per detail drawing, as specified and as directed byEIC / PMC. |
| 172 | Water Proofing Works |
| 173 | Removing existing terrace waterproofing with brick bat coba / screed from the terrac slab with help of breaker, hammer & chisel upto the slab lavel & stacking and disposing the debris etc complete as per direction of EIC / PMC. |
| 174 | TREATMENT TO TERRACE CONCRETE DEFECTS LIKE CONSTRUCTION JOINTS COLD JOINTS, HONEY COMBS & POROUS CONCRETE.All construction joints, honey combs, cold joints, after casting shall be treated by hacking open the affected area to sound concrete, fixing nozzles and grouting the same, under pressure with cement slurry mixed with plasticizer, and non shrink additive. etc complete as per direction of EIC / PMC . |
| 175 | TREATMENT TO TERRACE / PODIUM SLAB:The waterproofing system to be used shall be Formak 629 of M/s. Hitchins - Singapore a Liquid applied elastomeric Waterproofing System. The system shall be single component ready-mixed heavy-bodied polyisoprene based waterproofing membrane consisting of three layers, with a nominal thickness of 0.8-1.0 mm minimum. The reinforcement if used, shall be either 225gsm or 300gsm emulsion bond chopped strand fibre-glass mat. Formak 629 shall be flexible and passes the 3mm mandrel, and shall be able to bridge cracks upto 2.0mm (ASTM C 836).When Formak 629 is not reinforced, it shall have at least 527% Elongation (ASTM D 412), having Water vapor transmission of 122.32g/m2/24hours & No water penetration at 5bar (DIN-1048-Part-5). At all detailings like pipe protrusions, rain-water-down-pipes, edges and corners, application of the Formak 629 system shall be sufficiently dressed up and reinforced with fibre-glass reinforcement. Upon completion of the application of the Formak 629 system, the entire surface shall be checked for uniformity to ensure proper application of the system. etc. complete as per drawings & directions by EIC / PMC.Cleaning the surface for treatment by removing dust, dirt etc by wire brushing & water jetting. Surface cracks shall be raked out in \"V\" groove & sealed with non-shrink polymer mortar. |
| 176 | Providing and carrying out FORMAK 629 Polyisoprene based waterproofing system in one coat of Formak 629 primer and two coats of FORMAK 629 @ 0.6 kg /sqm / coat to slab and walls upto 0.30 mtr from slab in two coats brush applied and reinforcing with chopped strand fiber glass mat at upturns, cracks and around detailing as per the manufacturer\"s specifications. |
| 177 | Geotextile layer - P & laying a protective separation layer of non-woven needle-punched polyester geotextile mat of 120 gm/sqmminimum shall be loose laid over Waterproofing Membrane with minimum overlap of 75 mm before laying of screed / Brick bat coba. |
| 178 | Providing and laying brick bat coba with an average thickness of 115 mm in required slope finish with IPS. |
| 179 | Providing and fixing Providing and errecting bamboo scafolding All complete as per approval of designer & instruction of Engineer-in-charge / PMC. |
| 180 | Removing of existing ACP/china mosaic tile from the building façade / floor/wall & stacking and disposong the material as directed. as per directions of Engineer-In-Charge / PMC. |
| 181 | TREATMENT TO EXTERNAL WALL WITH WATERPROOF COATING :The wall waterproofing coating system to be used shall be of Hitchins - Singapore SEALFLEX Elastomeric Wall Waterproofing Coating System. It is a heavy-duty, high build, elastomeric wall coating system for external walls and other vertical substrates. It gives a strong, durable and elastic membrane that bridges small cracks and tolerates some movement of the substrate.It is ideally suitable for less sound substrates such as concrete or plaster that contains hairline cracks or that is subjected to movement within itself. The system shall consist of a suitable primer, a 100 % acrylic elastomeric bodycoat and a topcoat, and the total dry film thickness shall be approximately 320 microns . The system shall pass the 3.0mm Mandrel (SS 5), with elongation of more than 300 % (ASTM 412) and subjected to accelerated weathering test (SS 500) with no visible defects after 2,000 hours in the QUV Weatherometer.Its carbon dioxide diffusion resistance shall be 4.4 x 105 u (SS 500).It shall have a water vapour transmission rate of 48.3 gm/m2/24 hours (ASTM E96). Wet Scrub resistant, Alkali resistance & Algae resistnce as (SS 500) per standerd. etc. complete as per detail drawing, as specified and as directed byEIC / PMC. |
| 182 | Providing and carrying out FORMAK 629 Polyisoprene based waterproofing system in one coat of Formak 629 primer and two coats of FORMAK 629 @ 0.6 kg /sqm / coat to slab and walls upto 0.30 mtr from slab in two coats brush applied and reinforcing with chopped strand fiber glass mat at upturns, cracks and around detailing as per the manufacturer\"s specifications. |
| 183 | Loose Furinture (Table & Chair) Works. |
| 184 | Providing andplacing in position Reception Tableof required shape and size, vertical, top and bottom made of 19mm thk BWP marine grade plywood finished with approval Veneer on both side,the edge of top finished 12 x30 MM thick matching wood beading,the top finished in PU above 18mm thick glass top. The Reception table verticle,flap,Foot restare in 19mm thk BWP marine grade plywood finished with Approval Veneer internal side and external above 6mm thick toughfnedcolor back painted glassthe edge of finished 12 x30 MM thick veneer matchingbeading.provision Flap shutter shall be provided for Services, electrical,cabling cutouts as per the drawing. All the exposed wood work are to be finished with three or more coatsmelamine polish. The entire item is to be completed in totality as per the drawing and directions of the EIC/PMC. |
| 185 | Providing and fixing in position Sample reception Table as per the approved design, size and profile given in the detailed drawing consisting of:Table top – 25mm thick to be made of 18mm + 6mm thick BWPmarine grade plywood covered with 1mm thick approved laminate. Modesty Panel –18mm thick is to be made ofBWP marine grade plywood covered 1mm thick laminate. the modesty, Gable ends 25mm thick are to be made of two layers of 19 mm thick BWPmarine grade plywood covered with laminate on both the sides. The edge of the table top is to be finished with 30x25mm profiled moulding of matching wood. Allwooden surfaces are to be finished with three or more coats of melamine polish. Pedestail unit in 19,12,9MM thick marine grade plywoodwith 3 nos. ofdrawer, Both sidefinishl laminate finish etc, Electrical/ LAN cables tray are to be made as detailed in the drawing. Item includes hardware like soft closing drawer channel, cable manager etc. The entire item is to be completed in totality as per the architectural drawing and directions of the EIC/ PMC. |
| 186 | Providing and supply Lab table with sink of C-Frames manufactured from standard hollow metal sections adhering to standards of SEFA-8M, SEFA-10, EN-14727 and EN-13150.; confirming to I.S. Code 7138:1973 (Indian Standard specification for steel tubes for furniture) and all sheet metal components to be of CRCA confirming to IS Code 513:1994. The suspended under-bench welded units shall be supported on heavy-duty steel frames fully carrying the load of worktops.. Its superior strength is combined with aesthetically appealing end caps shall give maximum flexibility and modularity while making a layout. C-frame shall be constructed from a rectangular pipe with a cross section of 60mm x 30mm and shall be 2 mm thick and shall be without a vertical front leg to give a clean look. The C- frame legs shall be supplied with adjustable feet (tolerance from -5mm to +20mm) to correct the unevenness of flooring. The tubular enclosed type construction shall discourage dust accumulation and unwanted development of bacteria & fungus. Drainage gradient shall be well adjusted throughout the length of table and shall have horizontal supports for drainage systems. The structure shall have a removable back panel to provide access for maintenance throughout the length of table. The C-frame shall also have skirting at back bottom side. The C-frame shall be suitable for sitting and standing nominal heights of 750mm & 900mm respectively. The nominal table depths shall be 620 mm, 770 mm and 920 mm for wall side and 1540mm, 1840mm for Island tables. |
| 187 | The Corner Units shall fit well with 770mm & 920mm table depths. All frame- work is to be pre-treated 9 tank pre-treatement process with superior pure epoxy powder coated finish. The underbench cabinets must be welded in nature and main construction must be of 1.2mm. Make - Godrej / Kewaunee / Bicasa.Under Structure:Providing and supply of Horizontal Members : These shall be made from rectangular pipes of 2mm thickness. Cross- sectional dimensions of the pipe should be 60 x 30 x 2 mm. They shall be made of CRCA MS and coated with pure epoxy powder. These connect two C-Frames together as shown using C-clamps/U-clamps. Together with the C-Frames and Horizontal Members connected together, the skeletal structure of the work-bench is formed on which the worktop can be placed and the hanging-type storage cabinets can be suspended. Horizontal Members determine the width of the lab workbench as they form the member (distance) between two adjacent C-Frames. Providing and supply of Panels: All other panels used as End cover of the tables in case of Island tables and wall tables to cover the space between two tables or between the table and the wall. The cover panels to be made of 1.0 mm thick CRCA sheet as per IS Code 513:1994Electrical Trucking :Providing and supply of Electrical Trunking : Used for housing electrical switches and sockets, data and voice points, its top panel, bottom panel of the trunking shall be made from 1.0 mm thick CRCA MS panel. It shall be available in both, single sided and double sided configurations. |
| 188 | Granite:Providing and supply of Granite Work Top : It shall be 19mm (+/- 2mm) thick Jet Black Granite worktop. The exposed edges of the worktop shall be chamfered and smoothened. The bottom of the worktop shall be polished and there shall be a V- groove throughout the length of the exposed edges to protect the cabinets from coming in contact with the spillages |
| 189 | Size 2000 x 900 mm |
| 190 | Size 1800 x 900 mm |
| 191 | Size 2800 x 900 mm |
| 192 | Size 3400 x 900 mm |
| 193 | Providing and supply Lab working table of C-Frames manufactured from standard hollow metal sections adhering to standards of SEFA-8M, SEFA-10, EN-14727 and EN-13150; confirming to I.S. Code 7138:1973 (Indian Standard specification for steel tubes for furniture) and all sheet metal components to be of CRCA confirming to IS Code 513:1994. The suspended under-bench welded units shall be supported on heavy-duty steel frames fully carrying the load of worktops.. Its superior strength is combined with aesthetically appealing end caps shall give maximum flexibility and modularity while making a layout. C-frame shall be constructed from a rectangular pipe with a cross section of 60mm x 30mm and shall be 2 mm thick and shall be without a vertical front leg to give a clean look. The C- frame legs shall be supplied with adjustable feet (tolerance from -5mm to +20mm) to correct the unevenness of flooring. The tubular enclosed type construction shall discourage dust accumulation and unwanted development of bacteria & fungus. Drainage gradient shall be well adjusted throughout the length of table and shall have horizontal supports for drainage systems. The structure shall have a removable back panel to provide access for maintenance throughout the length of table. The C-frame shall also have skirting at back bottom side. The C-frame shall be suitable for sitting and standing nominal heights of 750mm & 900mm respectively. The nominal table depths shall be 620 mm, 770 mm and 920 mm for wall side and 1540mm, 1840mm for Island tables. |
| 194 | The Corner Units shall fit well with 770mm & 920mm table depths. All frame- work is to be pre-treated 9 tank pre-treatement process with superior pure epoxy powder coated finish. The underbench cabinets must be welded in nature and main construction must be of 1.2mm. Make - Godrej / Kewaunee / Bicasa.Under Structure:Providing and supply of Horizontal Members : These shall be made from rectangular pipes of 2mm thickness. Cross- sectional dimensions of the pipe should be 60 x 30 x 2 mm. They shall be made of CRCA MS and coated with pure epoxy powder. These connect two C-Frames together as shown using C-clamps/U-clamps. Together with the C-Frames and Horizontal Members connected together, the skeletal structure of the work-bench is formed on which the worktop can be placed and the hanging-type storage cabinets can be suspended. Horizontal Members determine the width of the lab workbench as they form the member (distance) between two adjacent C-Frames. Providing and supply of Panels: All other panels used as End cover of the tables in case of Island tables and wall tables to cover the space between two tables or between the table and the wall. The cover panels to be made of 1.0 mm thick CRCA sheet as per IS Code 513:1994Electrical Trucking :Providing and supply of Electrical Trunking : Used for housing electrical switches and sockets, data and voice points, its top panel, bottom panel of the trunking shall be made from 1.0 mm thick CRCA MS panel. It shall be available in both, single sided and double sided configurations. |
| 195 | Granite:Providing and supply of Granite Work Top : It shall be 19mm (+/- 2mm) thick Jet Black Granite worktop. The exposed edges of the worktop shall be chamfered and smoothened. The bottom of the worktop shall be polished and there shall be a V- groove throughout the length of the exposed edges to protect the cabinets from coming in contact with the spillages |
| 196 | Size 2000 x 900 mm |
| 197 | Size 2600 x 900 mm |
| 198 | Size 2600 x 1500 mm |
| 199 | Providing and fixingRunning Counter 6000mm in width. Table top is to be made of 19mm thick MarinePlywood IS710 plywood finished with 1mm thick laminate and drawer unit, tea tray, pencil tray, pullout tray, pedestal unit, footrest. All drawers to be in plywood with 19 mm in front & 12mm thk in rear & sides and bottom in 6 mm thk. Plywood Internal surfaces to be Laminate. . The modesty vertical 350MM, with s.s.stand mat finish. Item includes hardware like soft closing drawer channel, cable manager etc.The entire item is to be completed in totality as per the drawing and directions of the EIC/PMC |
| 200 | Providing, manufacturing & supplying square side/center table of ø600 X 450mm size. Table top made of 10 ±0.3 mm thick black tinted Toughened glass UV glued with bushes made in SS 202 grade for focing with understructure.The overall height of the table shall be 450/400 mm including Metal Stracture with duly powder coated. as per enclosed architectural drawing& directions of EIC/PMC. |
| 201 | Providing & arranging in position Main desk of size 1800 x 600 x 750 mm and side desk of size 1200 x 450 x 700/750 mm units in 25mm Thk Prelaminated Particle Board with 2mm PVC Edge Lipping on all exposed edges.Understructure : MS Powdercoated LegsIntermediate Legs : MS Powdercoated legs and supporting MS cross beams. Wire Management : MS Flip down Cable tray with 450mm Aluminium Flipup. MS Powdercoated horizontal cable tray with separator clips for power and data, switchplate to mount the switches and sockets as per requirement. Vertical wire entry cover with removable metal cover between the intermediate legs for wire uptake to MS cable tray from floor and 450mm Aluminium Flipup for switch access. Main Screen : 12mm Fabric Screen (Ht. 450mm)Modesty Panel : 18mm Thk Prelaminated Particle Board with PVC Edge Lipping on all exposed edgesProviding and fixing low height storage of, fabricated out of 18mm prelam board outside and balancing laminate from inside. Shelves also to be finished in balancing laminate. Cost of the storage units to be inclusive of finger groove detail for handles, SS hinges, tower bolts, ball catches, locks, and all necessary hardware all complete as per drawing and detail and as per the instructions of the architect. |
| 202 | Providing & arranging in position Main desk of size 2500 x 800mm units in 25mm Thk Prelaminated Particle Board with 2mm PVC Edge Lipping on all exposed edges.Understructure : MS Powdercoated LegsIntermediate Legs : MS Powdercoated legs and supporting MS cross beams. Wire Management : MS Flip down Cable tray with 450mm Aluminium Flipup. MS Powdercoated horizontal cable tray with separator clips for power and data, switchplate to mount the switches and sockets as per requirement. Vertical wire entry cover with removable metal cover between the intermediate legs for wire uptake to MS cable tray from floor and 450mm Aluminium Flipup for switch access. Main Screen : 12mm Fabric Screen (Ht. 450mm)Modesty Panel : 18mm Thk Prelaminated Particle Board with PVC Edge Lipping on all exposed edges. |
| 203 | Providing & arranging in position Main desk of size 3000 x 600mm units in 25mm Thk Prelaminated Particle Board with 2mm PVC Edge Lipping on all exposed edges.Understructure : MS Powdercoated LegsIntermediate Legs : MS Powdercoated legs and supporting MS cross beams. Wire Management : MS Flip down Cable tray with 450mm Aluminium Flipup. MS Powdercoated horizontal cable tray with separator clips for power and data, switchplate to mount the switches and sockets as per requirement. Vertical wire entry cover with removable metal cover between the intermediate legs for wire uptake to MS cable tray from floor and 450mm Aluminium Flipup for switch access. Main Screen : 12mm Fabric Screen (Ht. 450mm)Modesty Panel : 18mm Thk Prelaminated Particle Board with PVC Edge Lipping on all exposed edges. |
| 204 | Providing & arranging in position Main desk of size 2000 x 750mm units in 25mm Thk Prelaminated Particle Board with 2mm PVC Edge Lipping on all exposed edges.Understructure : MS Powdercoated LegsIntermediate Legs : MS Powdercoated legs and supporting MS cross beams. Wire Management : MS Flip down Cable tray with 450mm Aluminium Flipup. MS Powdercoated horizontal cable tray with separator clips for power and data, switchplate to mount the switches and sockets as per requirement. Vertical wire entry cover with removable metal cover between the intermediate legs for wire uptake to MS cable tray from floor and 450mm Aluminium Flipup for switch access. Main Screen : 12mm Fabric Screen (Ht. 450mm)Modesty Panel : 18mm Thk Prelaminated Particle Board with PVC Edge Lipping on all exposed edges. |
| 205 | Providing and fixing Single Bed of Size 2025Lx1000Dx650H with matress and pillow. Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2 mm. The legs should have corner brackets welded to it at two levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to join the side panels and headboard to the leg. Three nos. of Horizontal stiffeners are provided at equal intervals. The stiffeners are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. The middle Horizontal Stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. All Metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 Microns DFT.Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The overall width of the side panel is 150mm. The side panels have 18mm thick prelam particle board Baton running for required length to add rigidity to the structure. Head Board :- The head board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 650mm. Foot Board :- The foot board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 450mm.Bed Base: - The Bed Base is made up of 12mm thick Prelam Particle Board with both sideWhite laminate. |
| 206 | \"The basic structure of the study table shall be made out of 18 mm ply with all open edges covered with beading. The top shall be of 12 mm th. ply + 6 mm th. ply patta on outer side with 25x12 wooden beading outside to achieve required thickness.The table will have 2 no of drawer(100+ 175 \"\"mm HT) at top level, made out of 12 mm th. ply sides & 12 mm th. Ply front facia, sliding on channels.\" |
| 207 | Manufacturing & supplying Center table for Ante Room having 1000x600 mm size, table top made of 12 mm thick toughened clear float glass with bevelled edges, placed over teakwood frame work having tapering verticalsupports made eout of 50mm dia teakwoodcross section and alround horizontal wooden ties 4 nos. 50x19mm at top and 1 no. of size 25x19mm at bottom. The overall height of the table shall be 600mm including polishing all teakwood/ veneered surface with melamine polish complete as per enclosed architectural drawing & direction of EIC/Architect. |
| 208 | Providing, manufacturing & supplying square side/center table of ø600 X 450mm size. Table top made of 304 SS conical pipe with 12mm tougned Glass.The overall height of the table shall be 450/400 mm including Metal Stracture with duly powder coated. as per enclosed architectural drawing& directions of EIC/PMC. |
| 209 | Providing & arranging in position Executive Cabin Table Finished with Veneer in table size 2750 mm x 1200 mm x 750 mm) side table (size 1500 mm x 450 mm x 700 mm) desk units in 19mm thk. Marine plywood including side unit, drawer unit, tea tray, pencil tray, pullout tray, footrest. All drawers to be in plywood with 19 mm in front & 12mm thk in rear & sides and bottom in 6 mm thk. Plywood Internal surfaces to be laminate. Table tops, drawer unit fronts & sides to be finished as per drawings. The front modesty panel etc shall be finished as per drawings & instructions of the EIC/Consultant all complete. All trays in writing desks, side units to have concealed stoppers. All pencil trays shall have small compartments for keeping miscellaneous stationaries. All beadings, mouldings & exposed woodwork to be in teak wood. Foot rest shall be made out of 19 mm plywood frame work with 6 mm top and shall be finished with matching veneer all molding shall be finish in 3 coats of melamine polish. All the tables shall have keyboard drawers to accommodate keyboards and mouse wherever necessary as per drawing. Rate include of all hardware,like hinges, drawer channel, handles, lock, moulding, lipping patti etc. drawings and also shall include CPU unit as shown in the drawings approved by EIC. No seperate payment shall be made for this. Tables all exposed surface finished with a approved veneer in approved pattern as per drawings. All exposed surface of side unit to be finished with a approved veneer. |
| 210 | Providing & fixing in position side unit made out of 19 mm thk. Marine ply, with shelves, drawers, shutters etc. as per drawings, finished with approved veneer from outside & laminate from inside. Item to be completed in all respects as per drawing & instructions from EIC. The item shall include a set of drawer and openable shutters, as per the drawing and details. All shelves, openable shutters, drawer box, drawer front etc. shall be made out of 19 mm thick plywood. Drawer sides shall be in 12 mm thk Plywood. Drawer bottom shall be in 6 mm thk. Plywood. All exposed surfaces to be finished With veneer of approved shade and make. All complete with necessary hardware,like key board, CPU,Trolly, cable manger etc complected as per drawing & approval of Engineer - In - charge. |
| 211 | Providing and fixing in position Meeting Room Table ofvarious sizes as per the approved design and profile given in the detailed drawing consisting of :Table top - 43mm thick to be made of two layers of 19mm thick Marine Grade Plywood IS 710 plywood covered with 4mm thick approved veneer on top and 1mm thick approved laminate at the bottom of table provisioncable tray in 19mm thick Commercial Plywood IS303:2003 finished black colour laminate,The edge of the table top is to be finished with 50x43mm moulding of matching wood. All the exposed surfaces of the veneer and matching wood moulding to be finished with polyester resin polish(PU). The under structure of the table is to be made of powder coated M.S. legs of approved section and profile. Provision for power track is to be provided as detailed in the drawing. The Vertebrae (oval) to be provided for power cables. Necessary cut-out to be provided forpower track etc. The entire item is to be completed in totality as per the architectural drawing and directions of the EIC/Architect.Basic rate for Veneer: Rs.1,700/- Per Sqmt. |
| 212 | Providing & arranging in position PA Table Finished with Veneer in table size 1500 mm x 900 mm x 750 mm) side table (size 1000 mm x 450 mm x 700 mm) desk units in 19mm thk. Marine plywood including side unit, drawer unit, tea tray, pencil tray, pullout tray, footrest. All drawers to be in plywood with 19 mm in front & 12mm thk in rear & sides and bottom in 6 mm thk. Plywood Internal surfaces to be laminate. Table tops, drawer unit fronts & sides to be finished as per drawings. The front modesty panel etc shall be finished as per drawings & instructions of the EIC/Consultant all complete. All trays in writing desks, side units to have concealed stoppers. All pencil trays shall have small compartments for keeping miscellaneous stationaries. All beadings, mouldings & exposed woodwork to be in teak wood. Foot rest shall be made out of 19 mm plywood frame work with 6 mm top and shall be finished with matching veneer all molding shall be finish in 3 coats of melamine polish. All the tables shall have keyboard drawers to accommodate keyboards and mouse wherever necessary as per drawing. Rate include of all hardware,like hinges, drawer channel, handles, lock, moulding, lipping patti etc. drawings and also shall include CPU unit as shown in the drawings approved by EIC. No seperate payment shall be made for this. Tables all exposed surface finished with a approved veneer in approved pattern as per drawings. All exposed surface of side unit to be finished with a approved veneer. |
| 213 | Providing & fixing in position side unit made out of 19 mm thk. Marine ply, with shelves, drawers, shutters etc. as per drawings, finished with approved veneer from outside & laminate from inside. Item to be completed in all respects as per drawing & instructions from EIC. The item shall include a set of drawer and openable shutters, as per the drawing and details. All shelves, openable shutters, drawer box, drawer front etc. shall be made out of 19 mm thick plywood. Drawer sides shall be in 12 mm thk Plywood. Drawer bottom shall be in 6 mm thk. Plywood. All exposed surfaces to be finished With veneer of approved shade and make. All complete with necessary hardware,like key board, CPU,Trolly, cable manger etc complected as per drawing & approval of Engineer - In - charge. |
| 214 | Providing & fixing linear table made up of 25mm Thk Prelaminated Particle Board with 2mm PVC Edge Lipping on all exposed edges.Understructure : MS Powdercoated LegsIntermediate Legs : MS Powdercoated legs and supporting MS cross beams. Wire Management : MS Flip down Cable tray with 450mm Aluminium Flipup. MS Powdercoated horizontal cable tray with separator clips for power and data, switchplate to mount the switches and sockets as per requirement. Vertical wire entry cover with removable metal cover between the intermediate legs for wire uptake to MS cable tray from floor and 450mm Aluminium Flipup for switch access. Main Screen : 12mm Fabric Screen (Ht. 450mm)Modesty Panel : 18mm Thk Prelaminated Particle Board with PVC Edge Lipping on all exposed edges. |
| 215 | Providing and fixing in position board room Table of size ( 11400 X 3200 MM) mm as per approved design and shape given in the detailed drawing consisting of:Table Top – 65mm thick to be made of two to three requirdlayers of 19 + 19 +12 mm thick Marine Plywood covered with 4 mm thickApproval Burl veneer on top and 1 mm thick approved laminate at the bottom. Edge of the Table Top is to be finished with matching wooden moulding of size 65 X 65mm. Entire Table Top is to be finished withlamination Polish / polyester resin polish (PU). above expolsed top fixing 18mm thick onex with edge polish etc complected.\"Modesty panel of the Table is to be made of 19+12 mm Thick Marine Plywood and 4 mm thick veneer of approved make. All veneer and wooden surfaces are to be finished with three or more coats of melamine polish.Additional supports below the Table Top at suitable intervals are to be made of two layers of 19+19 mm thick Marine Plywood cladded with 4 mm thick veneer and matching wooden moulding of size 46 x 12 mm finished with three or more coats of melamine polish.Cable Cubby Boxing/ Cable Tray/s below the Table Top and at foot level are to be made of 19 mm thick Marine Plywood with 4 mm thickveneer finished with three or more coats of melamine polish. Inside of the Cable Trays are to be finished with 1mm thick approved laminate.Foot rest is to be made ofBrass rod of 50 mm dia / 19mm thk marine ply finish with 4mm thk veneer as per the drawing and instructionsof EIC/ PMC.\"The entire item is to be completed in totality with necessary materials/ labour as detailed in the drawing including necessary cut-outs for Monitors/ LAN/ Electrical outlets/ Goose neck microphonesas per drawing and instructions of EIC/ PMC.Ball Bearing, Cut out for Cable Cabeez, Soft Closing hinges. (Haffele, Hettich) |
| 216 | Supply, installation & commissioning of the work station as per dimension given in the drawing and with the following specifications. The item include the partitions also along with the work station as per drgs & detail specificationsi. Main Table: Top shall be fabricated out of 25 mm thk MDF finished with laminate of approved colour and shade all as per drawings. Also anodized / powder coated leg in approved color shall be provided for support as per drg/Client requirement. Main Table Size: As per drawing.ii. Side Table: Top shall be fabricated out of 25 mm thk MDF with shelves & sliding/openable shutters finished with laminate with Aluminiumprofile handles and Sliding channels in Aluminium as per Client/Architect approval Complete in all respects. Side tableconfiguration: As per attached drawing.STRUCTURE(As per drawing.): Supply and installation of Low Level partition of 1050 mm ht. Main partition and return frame shall be fabricated out of anodised aluminium / MS powder coated section to form min 50 mm thk partition with skirting/open skirting area at bottom as well as over or under tabletop with provision for raceway along with arrangement to pass the cable in vertical/Horizontal direction to reach table, cover of raceway shall be of openable type with necessary provisions/ cutout as required for electrical switches/ sockets as required. Return partition shall be min 50 mm thk with |
| 217 | Aluminum frames / MS powder coated section with necessary interlocking caps & trims top & sides of approved shade/ color. The structure shall be provided with leveling screws for adjusting the height to match the level. The main Frame works should be of aluminum / MSwith the joineries / supports for sturdiness is acceptable after review and approval by architect/Client. Partitions are in combination of approved color laminated panel, back painted glass with magnetic board, laminated panels with frosted white glass etc. so vendor to provide thepartitions as per drawing for which he should take approval before manufacturing. Vendor shall take approval from architect/Client for various color/shade combinations before manufacturing.FINISHESi. Partition finishes shall be out of prelaminated MDF both sides for main & return partition with laminate of approved shade/ quality. ThePartition shall be of panel type and the number of divisions shall be as per selection by Architect / Client.ii. The part of the partition shall be provided with white back painted glass of minimum 4mm thk.iii. The trims to be provided to be of approved colors and multiple color options as per architects selection and instructions. The design will as per drgs approved by the Architect or as per selection.Keyboard Pull out tray and retrofit mouse tray to be provided in Metal Tray in MS CRCA sheet. |
| 218 | L type -1 (size 1500 x 600 x 750mm & 1250 x 600 x 750mm |
| 219 | JSA, Sr & Jr. Clerk and supporting staff Desk Table ( Size 1500 X900 X 750) |
| 220 | Providing & arranging in position Lab Head Incharge & SSO Table Finished with Laminate in table size 2000 - 2500 mm x 1000 - 1200 mm x 750 mm) side table (size 1100 - 1300 mm x 450 mm x 700 mm) desk units in 19mm thk. Marine plywood including side unit, drawer unit, tea tray, pencil tray, pullout tray, footrest. All drawers to be in plywood with 19 mm in front & 12mm thk in rear & sides and bottom in 6 mm thk. Plywood Internal surfaces to be Laminate. Table tops, drawer unit fronts & sides to be finished as per drawings. The front modesty panel etc shall be finished as per drawings & instructions of the EIC/Consultant all complete. All trays in writing desks, side units to have concealed stoppers. All pencil trays shall have small compartments for keeping miscellaneous stationaries. All beadings, mouldings & exposed woodwork to be in teak wood. Foot rest shall be made out of 19 mm plywood frame work with 6 mm top and shall be finished with matching laminate all molding shall be finish in 3 coats of melamine polish. All the tables shall have keyboard drawers to accommodate keyboards and mouse wherever necessary as per drawing. Rate include of all hardware,like hinges, drawer channel, handles, lock, moulding, lipping patti etc. drawings and also shall include CPU unit as shown in the drawings approved by EIC. No seperate payment shall be made for this. Tables all exposed surface finished with a approved laminate in approved pattern as per drawings. All exposed surface of side unit to be finished with a approved laminate. |
| 221 | Providing & fixing in position side unit made out of 19 mm thk. Marine ply, with shelves, drawers, shutters etc. as per drawings, finished with approved laminate from outside & inside. Item to be completed in all respects as per drawing & instructions from EIC. The item shall include a set of drawer and openable shutters, as per the drawing and details. All shelves, openable shutters, drawer box, drawer front etc. shall be made out of 19 mm thick plywood. Drawer sides shall be in 12 mm thk Plywood. Drawer bottom shall be in 6 mm thk. Plywood. All exposed surfaces to be finished With laminate of approved shade and make. All complete with necessary hardware,like key board, CPU,Trolly, cable manger etc complected as per drawing & approval of Engineer - In - charge. |
| 222 | Providing & arranging in position Meeting desk of size 1800 x 900mm units in 25mm Thk Prelaminated Particle Board with 2mm PVC Edge Lipping on all exposed edges.Understructure : MS Powdercoated LegsIntermediate Legs : MS Powdercoated legs and supporting MS cross beams. Wire Management : MS Flip down Cable tray with 450mm Aluminium Flipup. MS Powdercoated horizontal cable tray with separator clips for power and data, switchplate to mount the switches and sockets as per requirement. Vertical wire entry cover with removable metal cover between the intermediate legs for wire uptake to MS cable tray from floor and 450mm Aluminium Flipup for switch access. Main Screen : 12mm Fabric Screen (Ht. 450mm)Modesty Panel : 18mm Thk Prelaminated Particle Board with PVC Edge Lipping on all exposed edgesProviding and fixing low height storage of, fabricated out of 18mm prelam board outside and balancing laminate from inside. Shelves also to be finished in balancing laminate. Cost of the storage units to be inclusive of finger groove detail for handles, SS hinges, tower bolts, ball catches, locks, and all necessary hardware all complete as per drawing and detail and as per the instructions of the architect. |
| 223 | Providing & arranging in position Cabin Table Finished with Laminate in table size 1800 mm x 1000 mm x 750 mm) side table (size 1000 mm x 450 mm x 700 mm) desk units in 19mm thk. Marine plywood including side unit, drawer unit, tea tray, pencil tray, pullout tray, footrest. All drawers to be in plywood with 19 mm in front & 12mm thk in rear & sides and bottom in 6 mm thk. Plywood Internal surfaces to be Laminate. Table tops, drawer unit fronts & sides to be finished as per drawings. The front modesty panel etc shall be finished as per drawings & instructions of the EIC/Consultant all complete. All trays in writing desks, side units to have concealed stoppers. All pencil trays shall have small compartments for keeping miscellaneous stationaries. All beadings, mouldings & exposed woodwork to be in teak wood. Foot rest shall be made out of 19 mm plywood frame work with 6 mm top and shall be finished with matching laminate all molding shall be finish in 3 coats of melamine polish. All the tables shall have keyboard drawers to accommodate keyboards and mouse wherever necessary as per drawing. Rate include of all hardware,like hinges, drawer channel, handles, lock, moulding, lipping patti etc. drawings and also shall include CPU unit as shown in the drawings approved by EIC. No seperate payment shall be made for this. Tables all exposed surface finished with a approved laminate in approved pattern as per drawings. All exposed surface of side unit to be finished with a approved laminate. |
| 224 | Providing & fixing in position side unit made out of 19 mm thk. Marine ply, with shelves, drawers, shutters etc. as per drawings, finished with approved laminate from outside & inside. Item to be completed in all respects as per drawing & instructions from EIC. The item shall include a set of drawer and openable shutters, as per the drawing and details. All shelves, openable shutters, drawer box, drawer front etc. shall be made out of 19 mm thick plywood. Drawer sides shall be in 12 mm thk Plywood. Drawer bottom shall be in 6 mm thk. Plywood. All exposed surfaces to be finished With laminate of approved shade and make. All complete with necessary hardware,like key board, CPU,Trolly, cable manger etc complected as per drawing & approval of Engineer - In - charge. |
| 225 | Providing & arranging in position Cabin Table Finished withLaminate in table size 1500 mm x 900 mm x 750 mm) side table (size 900 mm x 450 mm x 700 mm) desk units in 19mm thk. Marine plywood including side unit, drawer unit, tea tray, pencil tray, pullout tray, footrest. All drawers to be in plywood with 19 mm in front & 12mm thk in rear & sides and bottom in 6 mm thk. Plywood Internal surfaces to be Laminate. Table tops, drawer unit fronts & sides to be finished as per drawings. The front modesty panel etc shall be finished as per drawings & instructions of the EIC/Consultant all complete. All trays in writing desks, side units to have concealed stoppers. All pencil trays shall have small compartments for keeping miscellaneous stationaries. All beadings, mouldings & exposed woodwork to be in teak wood. Foot rest shall be made out of 19 mm plywood frame work with 6 mm top and shall be finished with matching laminate all molding shall be finish in 3 coats of melamine polish. All the tables shall have keyboard drawers to accommodate keyboards and mouse wherever necessary as per drawing. Rate include of all hardware,like hinges, drawer channel, handles, lock, moulding, lipping patti etc. drawings and also shall include CPU unit as shown in the drawings approved by EIC. No seperate payment shall be made for this. Tables all exposed surface finished with a approved laminate in approved pattern as per drawings. All exposed surface of side unit to be finished with a approved laminate. |
| 226 | Providing & fixing in position side unit made out of 19 mm thk. Marine ply, with shelves, drawers, shutters etc. as per drawings, finished with approved laminate from outside & inside. Item to be completed in all respects as per drawing & instructions from EIC. The item shall include a set of drawer and openable shutters, as per the drawing and details. All shelves, openable shutters, drawer box, drawer front etc. shall be made out of 19 mm thick plywood. Drawer sides shall be in 12 mm thk Plywood. Drawer bottom shall be in 6 mm thk. Plywood. All exposed surfaces to be finished With laminate of approved shade and make. All complete with necessary hardware,like key board, CPU,Trolly, cable manger etc complected as per drawing & approval of Engineer - In - charge. |
| 227 | Manufacturing & supplyingDining table of 1200 x 900 mm size. Table top to be made of Made out of BWR plywood with 1.0mthk laminated with duly edgebend and table top supported on framework of Conical pipe metal duly powder coated as per architectural drawing & direction of the EIC/PMC |
| 228 | Manufacturing & supplyingDining table of 3150 x 900 mm size. Table top to be made of Made out of BWR plywood with 1.0mthk laminated with duly edgebend and table top supported on framework of Conical pipe metal duly powder coated as per architectural drawing & direction of the EIC/PMC |
| 229 | Manufacturing & supplyingDining table of 2400 x 600 x 1050 mm size. Table top to be made of Made out of BWR plywood with 1.0mthk laminated with duly edgebend and table top supported on framework of Conical pipe metal duly powder coated as per architectural drawing & direction of the EIC/PMC |
| 230 | Manufacturing & supplyingDining table of 2600 x 600 x 1050 mm size. Table top to be made of Made out of BWR plywood with 1.0mthk laminated with duly edgebend and table top supported on framework of Conical pipe metal duly powder coated as per architectural drawing & direction of the EIC/PMC |
| 231 | Providing and Supplying, Fixing Chairman & MS Task Chair with Headrest,Mechanism -Bock Body weight Limiter MechanisamLumbar support - Complete automatic Lumbar support with no manual adjustments. Back - upholstered leather, foam cushions back. Seat - upholstered leather seat cushions. Arm rest - 3DAdjustable armrests connected to the backrest. External frame - Polished Aluminium.castor - Five star base with Hard castor for carpet flooring Headrest - Independent and not connected to the back of the chair. The entire item is to be completed in totality as per the architectural drawing and directions of the EIC/ PMC. |
| 232 | Providing and Supplying, Fixing Chairman & MS visitor Task Chair without Headrest,Mechanism -Bock Body weight Limiter MechanisamLumbar support - Complete automatic Lumbar support with no manual adjustments. Back - upholstered leather, foam cushions back. Seat - upholstered leather seat cushions. Arm rest - 3DAdjustable armrests connected to the backrest. External frame - Polished Aluminium.castor - Five star base with Hard castor for carpet flooring Headrest - Independent and not connected to the back of the chair. The entire item is to be completed in totality as per the architectural drawing and directions of the EIC/ PMC. |
| 233 | \"Providing and Supplying Fixing, Chairman & MS around meeting table Task Chair with Headrest,Mechanism -Bock Body weight Limiter MechanisamLumbar support - Complete automatic Lumbar support with no manual adjustments. Back - upholstered leather, foam cushions back. Seat - upholstered leather seat cushions. Arm rest - 3DAdjustable armrests connected to the backrest. External frame - Polished Aluminium.castor - Five star base with Hard castor for carpet flooring Headrest - Independent and not connected to the back of the chair. The entire item is to be completed in totality as per the architectural drawing and directions of the EIC/ Architect. |
| 234 | \"Providing and Supplying Fixing, PA & Lab head Incharge High Back Chair. SEAT ASSEMBLY: The seat is made up of 1.5±0.1 cm thick hot-pressed plywood upholstered with fabric and moulded polyurethane foam.SEAT SIZE: 51.8cm (W) x 49.7cm (D) BACK ASSEMBLY: The Back is injection moulded in glass filled Polypropylene which is 2 upholstered with Mesh fabric. The back consist of adjustable Lumbar support made of injection moulded Polypropylene having an adjustment of 5.0 10.1 cm.BACK SIZE: 47.9 cm(W) x 66.9 cm (H)HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane seat foam is moulded with density 45+/-2 kg/m and hardness 14 ± 2 kgf as per IS:7888 for 25% compression.ARMRESTS (ADJUSTABLE):The height adjustable armrest is made of Polypropylene and can be adjusted to 6.010.1cm height it also has swivel and To and Fro adjustment with moulded PU armtopACTIVE BIO-SYNCHRO MECHANISM: The adjustable tilting mechanism is designed with the following features360° revolving type Front-pivot for tilt with feet resting on ground & continuous lumber support ensuring more comfortTill tension adjustment can be operated in seating position5 position Tilt limiter giving option of variable sit angle to the chairSeat/back tilting ratio of 1:2 The mechanism housing is made up of HPDC Aluminium & black powder coated (DFT 40 to 60 micron)HEADREST The Headrest sub-assembly is made up of injection moulded glass filed Polypropylene which is upholstered with moulded HR polyurethane loam and fabric has an adjustment of 3.00.1cm & it is assembled over GRETA 20F The complete headrest assembly is retro fic to the main chairPNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment with an adjustment stroke of 10.0±0.3cm.PEDESTAL ASSEMBLY: The pedestal is injection moulded in black 30% glass-filled Nylon and fitted with 5 nos. twin wheel castors. The pedestal pitch-center dia is 166.1±0.5 cm.(76.1 ± 1.0 cm. with castors).TWIN WHEEL CASTORS: The twin wheel castors are Injection moulded in black Polyamide having 6.01 0.1cm wheel Diameter.WIDTH (W) - 76.0cmDEPTH (D) - 76.0cmHEIGHT (H) - 114.0 cm- 123.5cmSEAT HEIGHT - 43.5 - 54.0cmThis product should be certified by Indoor Advantage GOLD, GREENGUARD GOLD, BIFMA LEVEL 2 & GREENPRO. as per the architectural drawing and directions of the EIC/ PMC |
| 235 | \"Providing and Supplying Fixing, PA & Lab Head Incharge & conference room Mid back Chair SEAT ASSEMBLY: The seat is made up of 1.5±0.1 cm thick hot-pressed plywood upholstered with fabric and moulded polyurethane foam.SEAT SIZE: 51.8cm (W) x 49.7cm (D) BACK ASSEMBLY: The Back is injection moulded in glass filled Polypropylene which is 2 upholstered with Mesh fabric. The back consist of adjustable Lumbar support made of injection moulded Polypropylene having an adjustment of 5.0 10.1 cm.BACK SIZE: 47.9 cm(W) x 66.9 cm (H)HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane seat foam is moulded with density 45+/-2 kg/m and hardness 14 ± 2 kgf as per IS:7888 for 25% compression.ARMRESTS (ADJUSTABLE):The height adjustable armrest is made of Polypropylene and can be adjusted to 6.010.1cm height it also has swivel and To and Fro adjustment with moulded PU armtopACTIVE BIO-SYNCHRO MECHANISM: The adjustable tilting mechanism is designed with the following features360° revolving type Front-pivot for tilt with feet resting on ground & continuous lumber support ensuring more comfortTill tension adjustment can be operated in seating position5 position Tilt limiter giving option of variable sit angle to the chairSeat/back tilting ratio of 1:2 The mechanism housing is made up of HPDC Aluminium & black powder coated (DFT 40 to 60 micron)HEADREST The Headrest sub-assembly is made up of injection moulded glass filed Polypropylene which is upholstered with moulded HR polyurethane loam and fabric has an adjustment of 3.00.1cm & it is assembled over GRETA 20F The complete headrest assembly is retro fic to the main chairPNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment with an adjustment stroke of 10.0±0.3cm.PEDESTAL ASSEMBLY: The pedestal is injection moulded in black 30% glass-filled Nylon and fitted with 5 nos. twin wheel castors. The pedestal pitch-center dia is 166.1±0.5 cm.(76.1 ± 1.0 cm. with castors).TWIN WHEEL CASTORS: The twin wheel castors are Injection moulded in black Polyamide having 6.01 0.1cm wheel Diameter.WIDTH (W) - 76.0cmDEPTH (D) - 76.0cmHEIGHT (H) - 114.0 cm- 123.5cmSEAT HEIGHT - 43.5 - 54.0cmThis product should be certified by Indoor Advantage GOLD, GREENGUARD GOLD, BIFMA LEVEL 2 & GREENPRO. as per the architectural drawing and directions of the EIC/ PMC |
| 236 | Providing, supplying and placing of Mid Back Chair. Seat / Back Assembly: The seat is made up of 1.5 +- 0.1 cm.thick hot-pressed plywood and upholstered with fabric upholstery covers and moulded Polyurethane foam. The seat has extra thick foam on front edge to give comfort to popliteal area. The Back is injection moulded in glass filled Polypropylene which is upholstered with Mesh fabric. The back consist of adjustable lumbar support made of injection moulded Polypropylene having an adjustment of 5.0 ±0.1 cm. The chair seat & back size are *SEAT SIZE - 53.5 cm. (W) x 51.0 cm. (D)*MESH BACK SIZE - 51.0 cm. (W) x 70.0 cm. (H) HIGH RESILIENCE (HR) POLYURETHANE FOAM The HR polyurethane seat foam is moulded with density 45±2 kg/m³ and hardness 16±2 kgf as per IS:7888 for 25% compression. ARMRESTS: The height adjustable armrest is made of glass filled Nylon and can be adjusted to 6,0±0.1cm height. It also has swivel and To and Fro adjustment with moulded PU armtop. CENTER TILT SYNCHRO MECHANISM WITH SEAT SLIDE & MULTI LOCK: The mechanism is designed with the following features:360° revolving type, 3 position locking with anti shock mechanism, Seat depth adjustment of 6.0 ±0.5cm. can be locked in 6 positions, Tilt tension adjustment.PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment with an adjustment stroke of 9.5 ± 0.3cmPEDESTAL ASSEMBLY: The pedestal is High Pressure Diecast polished Aluminium and fitted with 5 nos, twin wheel castors. The pedestal pitch-center dia is Ø65.0 ± 0.5 cm.(75.0 ±1.0 cm, with castors).TWIN WHEEL CASTORS: The twin wheel soft castors are injection moulded in black Nylon with PU lining, having 6.0± 0.1cm wheel Diameter.This product should be certified by Indoor Advantage GOLD, GREENGUARD GOLD,BIFMA Level 2 & GREEN PRO. etc complete as per direction of EIC / PMC |
| 237 | Providing & supplying Low Back chair SEAT ASSEMBLY: The seat is made up of 1.5±0.1 cm thick hot-pressed plywood upholstered with fabric and moulded polyurethane foam.SEAT SIZE: 51.8cm (W) x 49.7cm (D) BACK ASSEMBLY: The Back is injection moulded in glass filled Polypropylene which is 2 upholstered with Mesh fabric. The back consist of adjustable Lumbar support made of injection moulded Polypropylene having an adjustment of 5.0 10.1 cm.BACK SIZE: 47.9 cm(W) x 66.9 cm (H)HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane seat foam is moulded with density 45+/-2 kg/m and hardness 14 ± 2 kgf as per IS:7888 for 25% compression.ARMRESTS (ADJUSTABLE):The height adjustable armrest is made of Polypropylene and can be adjusted to 6.010.1cm height it also has swivel and To and Fro adjustment with moulded PU armtopACTIVE BIO-SYNCHRO MECHANISM: The adjustable tilting mechanism is designed with the following features360° revolving type Front-pivot for tilt with feet resting on ground & continuous lumber support ensuring more comfortTill tension adjustment can be operated in seating position5 position Tilt limiter giving option of variable sit angle to the chairSeat/back tilting ratio of 1:2 The mechanism housing is made up of HPDC Aluminium & black powder coated (DFT 40 to 60 micron)HEADREST The Headrest sub-assembly is made up of injection moulded glass filed Polypropylene which is upholstered with moulded HR polyurethane loam and fabric has an adjustment of 3.00.1cm & it is assembled over GRETA 20F The complete headrest assembly is retro fic to the main chairPNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment with an adjustment stroke of 10.0±0.3cm.PEDESTAL ASSEMBLY: The pedestal is injection moulded in black 30% glass-filled Nylon and fitted with 5 nos. twin wheel castors. The pedestal pitch-center dia is 166.1±0.5 cm.(76.1 ± 1.0 cm. with castors).TWIN WHEEL CASTORS: The twin wheel castors are Injection moulded in black Polyamide having 6.01 0.1cm wheel Diameter.WIDTH (W) - 76.0cmDEPTH (D) - 76.0cmHEIGHT (H) - 114.0 cm- 123.5cmSEAT HEIGHT - 43.5 - 54.0cmThis product should be certified by Indoor Advantage GOLD, GREENGUARD GOLD, BIFMA LEVEL 2 & GREENPRO. as per the architectural drawing and directions of the EIC/ PMC |
| 238 | Providing & Supplyingdining chair of Monobloc moulded shell with SS base etc complete as per direction of EIC / PMCW: 450 X D: 450 X H: 800 |
| 239 | Providing & Supplyingdining chair of Metal base with laminaed seat and back etc complete as per direction of EIC / PMCW: 380 X D: 400 X H: 1000 |
| 240 | Providing & supplying Lounge Chair of Built-in shaped sponge Sponge: Fully shaped sponge Fabric, base frame to be made out of metal frame stracture with duly powder coated and joint metal wood finishas per drawing and reference images and instruction from Architects. |
| 241 | Providing & Supplying Single seater sofa which is made out of Metal / Wood stracture frame with high density foam with approved architect Fabric / Tech Leather. Base frame is inMetal powder coated base etc complete as per direction of EIC / PMC |
| 242 | Providing, Manufacturing & supplying three seater sofaof over all size2100 x 800 x 825mm made of teakwood frame, seat to be made of 75mm thickPUfoam, moulded with 25mm thick PU foam to the required shape supported on horizontal high tensile MS-springs and cotton strings,back made of 75mm thick PU foam, moulded with 25mm thick PU foam to the required shape supported on rubber strips. The sofa chair shall be upholsteredwithfabric of approved quality & finish costing not less than Rs.1,000/- per meter Base : to be made out of S S Framewith duly polishas per enclosed architectural drawing& directions of EIC/PMC. |
| 243 | Providing, Manufacturing & supplying Single seater sofaof over all size 800 x 800 x 825mm made of teakwood frame, seat to be made of 75mm thickPUfoam, moulded with 25mm thick PU foam to the required shape supported on horizontal high tensile MS-springs and cotton strings,back made of 75mm thick PU foam, moulded with 25mm thick PU foam to the required shape supported on rubber strips. The sofa chair shall be upholsteredwithfabric of approved quality & finish costing not less than Rs.1,000/- per meter Base : to be made out of S S Framewith duly polishas per enclosed architectural drawing& directions of EIC/Architect. |
| 244 | Providing, supplying and placing of two seater sofa. SEAT FOAM : The seat is made up of PU foam in Density 28 ±2 kg/cu.mtr with an additional top layer of supersoft PU foam in Density 32 ± 2 kg/cu, upholstered with fabric or leatherette.BACK FOAM : The back is made up of PU foam in Density 28 ± 2 kg/cu. mtr with two additional top layer of supersoft foam of density 32±2 kg/cu. mtr, upholstered with fabric or leatherette.UNDERSTRUCTRE : Understructure is made up of 1.2±0.1 cm. thick hot pressed plywood [moisture resistance & termite proof as per IS:303] & pinewood of cross sections devoid of major knots & surface defects. 6 nos. per seat & 3.8mm Dia zigzag spring assembly is mounted over understructure for cushioning purpose.LEG ASSEMBLY : It is a welded Assembly made in Stainless steel (grade SS 202) tube & plate with plastic endcap. etc complete as per direction of EIC / PMC |
| 245 | Providing, supplying and placing of three seater sofa. SEAT FOAM : The seat is made up of PU foam in Density 28 ±2 kg/cu.mtr with an additional top layer of supersoft PU foam in Density 32 ± 2 kg/cu, upholstered with fabric or leatherette.BACK FOAM : The back is made up of PU foam in Density 28 ± 2 kg/cu. mtr with two additional top layer of supersoft foam of density 32±2 kg/cu. mtr, upholstered with fabric or leatherette.UNDERSTRUCTRE : Understructure is made up of 1.2±0.1 cm. thick hot pressed plywood [moisture resistance & termite proof as per IS:303] & pinewood of cross sections devoid of major knots & surface defects. 6 nos. per seat & 3.8mm Dia zigzag spring assembly is mounted over understructure for cushioning purpose.LEG ASSEMBLY : It is a welded Assembly made in Stainless steel (grade SS 202) tube & plate with plastic endcap.etc complete as per direction of EIC / PMC |
| 246 | Plumbing Works. |
| 247 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 248 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings,remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 249 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete. |
| 250 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 251 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 252 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. |
| 253 | Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. |
| 254 | Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. |
| 255 | Providing and fixing C.P. BIB cock with wall flange of approvedmake including necessary sockets/ union nut etc. complete as directed by Engineer in charge. |
| 256 | Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make includingn ecessary sockets/unionnut etc. complete. |
| 257 | Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug,bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 258 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 259 | Providing and fixingsink cock with regular swinging spout (Wall / floor Mounted Model) with wall flange having flow rate up to6.0 Litr/Minute of of approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) |
| 260 | Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. |
| 261 | Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc complete |
| 262 | Providing and fixing white european type wall-hung, of size 360mm x 360mm x 575mm with flush valve of approved make including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge. |
| 263 | Providing and fixing white glazed urinal with Pressmatic auto closing valvehaving flow rate up to 4.0 Litr/Minute of approved make with P.V.C. waste pipewith fittingarrangementetc.complete as directed by Engineer in charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) |
| 264 | Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. |
| 265 | Providing and fixing Table top white wash basin of size 120x635x405mm rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. |
| 266 | Providing and laying in walls/ceilings/floors 50 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 8.57 kg/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 267 | Providing and laying in walls/ceilings/floors 80 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 8.57 kg/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 268 | Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) |
| 269 | Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 270 | Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. |
| 271 | Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. |
| 272 | Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. |
| 273 | Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. |
| 274 | Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete. |
| 275 | Providing and fixing screw down for 65 mm. dia. wheeled stop tap of brass including necessary sockets/union nut complete. |
| 276 | Providing and fixing screw down for 80 mm. dia. wheeled stop tap of brass including necessary sockets/union nut complete. |
| 277 | Providing,layingandfixingP.V.C.pipeof40mmdia.withfittingssuchasbends,tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removingexistingpipelineifnecessaryandconveyingandstackingthesameinPWD chowky or as directed etc. complete. |
| 278 | Providing,layingandfixingP.V.C.pipeof50mmdia.withfittingssuchasbends,tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removingexistingpipelineifnecessaryandconveyingandstackingthesameinPWD chowky or as directed etc. complete. |
| 279 | Providing,layingandfixingP.V.C.pipeof75mmdia.withfittingssuchasbends,tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removingexistingpipelineifnecessaryandconveyingandstackingthesameinPWD chowky or as directed etc. complete. |
| 280 | Providing, laying andfixing P.V.C. pipe of 110mm. dia. withfittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removingexistingpipelineifnecessaryandconveyingandstackingthesameinPWD chowky or as directed etc. complete. |
| 281 | Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. |
| 282 | ProvidingandconstructingBrickMasonryInspectionChamber90cmx45cmx90cm including1:4:8cementconcretefoundation1:2:4cementconcretechannelshalfround G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete. |
| 283 | ProvidingandconstructingBrickMasonryInspectionChamber60cmx45cmx90cm including1:4:8cementconcretefoundation1:2:4cementconcretechannelshalfround G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75Kilogramwith lid and frame fixed in cement concrete. |
| 284 | Providing and laying 100 mm dia salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete. |
| 285 | Providing and laying 150 mm dia salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete. |
| 286 | Providing and laying 225 mm dia salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete. |
| 287 | Providing and laying concrete pipes of I.S.NP. class of 100mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 288 | Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 289 | Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 290 | Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 291 | Supplying & erecting minimum three & above star rated Centrifugal water pump (Monoblock), 415 V, three phase 50 cycles A.C. supply of 11.25 KW/ 15 HP with discharge 1480/540 Litres per Minute (LPM) for head of 24/74 m and 80 mm suction/ 65 mm delivery pipe, on provided C.C. foundation as per specification No. WP-CGP |
| 292 | Supplying & erecting Minimum three & above star rated Centrifugal water pump (Monoblock), 415V, three phase 50 cycles A.C. supply of 2.25 KW/3 HP with discharge 600/110 Litres per Minute (LPM) for head of 13/43 m and 65 mm suction/ 50 mm delivery pipe on provided C.C. foundation as per specification No. WP-CGP |
| 293 | Providing and fixing in position Soap Dispenser as per instructions from EIC/Architect |
| 294 | Providing and fixing Flush Valve of approved quality etc complete. As per direction of Engineer - in - Charge. |
| 295 | Providing and Fixing of Mirrors in Toilets of approved Indian quality, copper plated with 10 mm thick plywood backing in the masonry etc. complete.As per direction of Engineer - in - Charge. |
| 296 | Supplying, Providing and fixing in position of approved make first quality, recessed, roller type or box type white glazed toilet paper holder with flap etc complete as per direction of Engineer - in - charge. |
| 297 | Providing and fixing Chromium Plated Alluminium Towel Rail 750 mm (2\"6\") long, 20mm (3/4\") dia and of approved quality fixed on chromium plared bracket including providing teak wood gutties in masonry etc complete as per direction of Engineer - in - charge |
| 298 | Providing and fixing in position Double coat hooks as per instructions from EIC/Architect |
| 299 | Providing and fixing in position Hand dyrer as per instructions from EIC/Architect |
| 300 | Providing and fixing in position Urinal partition made up of 10mm thk frosted glass with chrome finish bracket for fixing of glass as per instructions from EIC/Architect |
| 301 | Electrical Works. |
| 302 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. withnecessary accessories in wall/floor with chiselling appropriately as perspecification No: WG-MA/CC. |
| 303 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. withnecessary accessories in RCC work/false ceiling/false flooring as per specificationNo. WG-MA/CC. |
| 304 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. withnecessary accessories in wall/floor with chiselling appropriately as perspecification No: WG-MA/CC. |
| 305 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia withnecessary accessories in RCC work/false ceiling/false flooring as per specificationNo. WG-MA/CC. |
| 306 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. withnecessary accessories in wall/floor with chiselling appropriately as perspecification No: WG-MA/CC. |
| 307 | Supplying and laying HMS PVC conduit FRLS grade 32mm dia. withnecessary accessories in RCC work/false ceiling/false flooring as per specificationNo. WG-MA/CC. |
| 308 | Concealing of provided G.I. pipe/H.G. screwed conduit/PVC pipe inwall/floor/false ceiling complete as per specification No:WG-PW/CW |
| 309 | Supplying and erecting 20mm dia. corrugated flexiblepolypropyleneconduit |
| 310 | Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit. |
| 311 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVCinsulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places as per specification No: WG-MA/BW |
| 312 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW. (Note-3-Rates of earth wire shall be calculated as one half rate of mains of bunch of two wire) |
| 313 | Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 314 | Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other placesas per specification No: WG-MA/BW |
| 315 | upplying and erecting mains with 3x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 316 | Supplying and erecting Ceiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/PVC junction box. |
| 317 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 318 | Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 319 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 320 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 321 | Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. |
| 322 | Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 323 | Supplying and erecting modular type computer Jack RJ45 with safety shutter,duly erected on provided plate and box with wiring connections complete. |
| 324 | Supplying and erecting modular type bell indicator, duly erected on provided plate and box with wiring connections complete. |
| 325 | Supplying and erecting modular type buzzer 220 / 250V, duly erected onprovided plate and box with wiring connections complete. |
| 326 | Supplying and erecting modular type (two module) electronic step regulatorfor fan,duly erected on provided plate and box with wiring connections complete |
| 327 | Supplying and erecting modular type blanking plate one module, duly erectedon provided plate & box. |
| 328 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 329 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 330 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 331 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 332 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 333 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 334 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 335 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW |
| 336 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW |
| 337 | Point wiring for independent plug, concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as perspecification No WG-PW/SW |
| 338 | Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW |
| 339 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid inprovided PVC casing capping/conduit as perspecification No. WG-TW |
| 340 | Supplying & erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid inprovided PVC casing capping/conduit as per specification No. WG-TW |
| 341 | Supplying, erecting & commissioning MDF Box 150x150 pairs made from min.1.5mm thick MS sheet as per specification no. WG-TW |
| 342 | Supplying, erecting & commissioning 20 pairs FR junction box with mouldedplastic enclosure as per specification no. WG-TW |
| 343 | Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of6 x 32 extensions suitable upto 96 extensions complete. |
| 344 | Supplying and installing cat-6 LSZH cable suitable for networking as per specification no. WG-COC/NC |
| 345 | Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80,CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f.>0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 346 | Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W,CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV,Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 347 | Supplying and erecting LED square / circular Max. 11 W downlighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. rippleof 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 348 | Supplying and erecting LED square / circular Max. 14 W downlighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. rippleof 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 349 | Supplying and erecting LED square / circular Max. 18 W downlighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. rippleof 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 350 | Supplying and erecting bulk head LED fitting max. 10W with high transitivitydiffuser with system lumens output of min. 1100 lumens, min. efficacy of 110lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f.>0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life classof 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVCBlock / wooden board with 3 years warranty. |
| 351 | Supplying and erecting LED Strip light 5m Length Max. 45 W IP20 class having minimum lumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f.>0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50,including driver with 1 year warranty. |
| 352 | Supplying LED concealed type foot / step light with aluminium body for indoor / outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush withsurface with 1 year warranty. |
| 353 | Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCTupto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs.at L70B50, including driver with end caps on provided PVC Block / woodenboard with 3 years warranty. |
| 354 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCTupto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs.at L70B50, including driver, with end caps on provided PVC Block / woodenboard with 3 years warranty. |
| 355 | Supplying and erecting 3 Watts LED Eyeball type Light to highlight paintings. 38 degree Beam angle-110 Lumens -700mA |
| 356 | Supplying and erecting 25W LED Linear LED Light. Uniquely clean & simple lighting system offering continuous, uniform lines of light across ceilings. The aluminium extruded recessed light meant for POP/Gypsum ceilings gives continuous lines of light distribution with the possibility of various shapes (recess mounting clamps included). ( |
| 357 | Supplying and erecting integrated LED Circular Pendant downward 3 rings (2000⌀ , 1200⌀, 600⌀). Structure finish of gold. Diffuser material of polycarbobate. Opal diffuser finish and warranty of 5 years. Class1. IP20. Including drivers all required accessories. Maximum power of light source 182.5W. Color temperature of 3000K. Color rendering 90. Hours of life 50000h. Voltage frequency range 90-305/50-60Hz. (Model to be confirmed with architect.) |
| 358 | Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 800mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser,havingsystem lumens output of Min. 800 Lumens, min.efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. > 0.90,operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as perspecification NoFG-ODF/FLS2. |
| 359 | Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. |
| 360 | Supplying and erecting Street light bracket for erection of Single fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC |
| 361 | Providing & erecting 4 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no.OH-PL/OPL |
| 362 | Supplying and erecting integrated LED Post Top 45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser,having system lumens output of Min.4500 Lumens, min. efficacy of 100lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs. at L50B50 ,including driver complete with 2 Year warranty as per specification No FGODF/FLS2. |
| 363 | Supplying and erecting integrated LED round burial light 6W IP65 & IK10 class having pressure die-cast housing, having system lumens output of Min.500 Lumens, min. efficacy of 85 lumen/W, CRI>80, CCT upto 6500K,THD<10%, p.f. >0.90, operating range of 100-240V, inbuilt surge protection of4 kV, Life class of 50,000 Hrs. at L50B50, including driver, salt spray tested for500 Hrs. including making of recess of appropriate size for flushing into surfacewith 2 Year warranty as per specification NoFG-ODF/FLS2. |
| 364 | Supplying and erecting Concealed type foot/step light Max. 5W having IP67.IK10 rated Pressure die cast housing having system lumens output of Min. 500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 5000K, Beam Angleof 110 deg., THD<10%, SDCM<5, p.f. >0.95, operating range of 230-270V,surge protection of 2.5 kV, Life class of 25,000 Hrs. at L70B50, including driverby making necessary arrangement/recess in wall to make it flush with surface with 2 Year warranty. |
| 365 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected,complete. |
| 366 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF |
| 367 | Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slabwith making the site as original. |
| 368 | Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paintand two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level ofthe slab. |
| 369 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly paintedfor fan complete erected with PVC three core flexible cable 1 sq. mm copperPVC wire. |
| 370 | Supplying, erecting, testing and commissioning self contained water cooler 230 / 250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. APWCR/WC |
| 371 | Supply Installation testing & commissioning of 50 kVA rates output UPS with voltage range 415 VAC, 3phase, 5 wire (3PH+2N).Output voltage regulation of ±1 % (static).Output Frequency of 50 Hz ± 0.5 Hz. Pure Sine waveform. Crest factor 3:1. Continous duty.Output factor 0.8. Total harmonic distortion at 100% non-linear load : = 5% & Total harmonic distortion at 100% linear load : = 3%. Inductive, capacitive, resistive type of load. Provided with maintainance bypass. Input voltage range 415VAC ± 10 %, 3-phase, 5-wire. Frequency Range of 50Hz ± 5 % with input power factor > 0.96. Battery backup for 30 minutes on 80% Load. Sealed maintenance free batteries with battery rack connectors. Operating temperature for UPS shall be up to 40 deg C with operating relative humidity 10 % to 90 % RH. Efficiency of >/= 90%. Switching time < 10 ms. Ingress protection of IP20 or better. LCD display with display parameters of Battery voltage, Charging status, outputvoltage, output current, input voltage, input current, event log etc. Rectifier o/p short circuit protection, inverter output short circuit protection, overvoltage protection. Communication interface Shall be able to transmit data to remote PC over RS485/ethernet link: supporting cards,cable and software shall be provided. EMC compliance: IEC/EN 62040-2, IEC/EN61000-3-11 or equivalent. Safety compliance: IEC/EN 62040-1-1, or equivalent. |
| 372 | Supplying & erecting single phase, 240V, street light control panel up to themax load of 6kW, SPN MCB 40A, powder coated CRCA 14 SWG sheet,outdoor type, having IP54, IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, controlwiring, metering device, etc. for automatic operation, with over current, short circuit, earth fault protection on provided iron frame/ CC foundation. |
| 373 | Supplying, erecting & marking FP MCB 40A to 63A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specification no.SW-MCB |
| 374 | Supplying, erecting & marking TP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no.SW-MCB |
| 375 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 376 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 377 | Providing & erecting 4 Pole MCCB, 415V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line load bias in provided enclosure / panel as per specification no.SW-MCCB |
| 378 | Supplying & erecting triple pole and neutral distribution board (TPNDB),SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type)as per specification no. SW-SWR/MCBDB |
| 379 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 12 ways / 36 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type)as per specification no. SW-SWR/MCBDB |
| 380 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 381 | Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO |
| 382 | Supplying, fixing and commissioning 4 pole RCBO 63A, with over current, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO |
| 383 | Note - The LV switchboard shall be type tested assemblies, all type tests as defined in latest IEC 61439-1&2. Also it should comply IEC 61641 Internal arc withstand for 100 kA for 0.3 Sec. LT panels must be built up from compartment housing, circuit breakers, control-gear, relays, busbars, controls and other items of equipment as per BOQ. Low Voltage switchgear & control gear must comply IEC 60 947 /IS 13947.The Short circuit current with minimum duration of 1sec. for LV switchgear panels shall be as indicated in SLD.The LV Main Switchboard shall be identical in mechanical construction to the LV Switchboard which had been type-tested by an acceptable, multi-fold design with impact test IK07-IK10.The design temperature for the equipment provided in the main low voltage switchboards shall be +50°C. the switchboard shall be of form 4b, for form of separation onlymetallic compartmentalization shall be used, Hylem / PVC sheets shall not be allowed.Switch board panels and cubicles shall be fabricated with CRCA Sheet Steel of thickness not less than 2.0 mm. Busbars shall be made of high conductivity, and high strength Aluminum E91 grade Busbars shall be of rectangular cross sections , not more than 6mm thickness better suitable for full load current for phase bus bars and half/ full rated current for neutral bus bar or as stipulated in schedule of quantities. Busbar shall be suitable to withstand the stresses of fault level as specified in schedule of quantities. |
| 384 | The material and the spacing of the Busbar supports should be same as per the type tested assembly. Busbar shall be tin plated with silver contacts.The cables and control wires shall be suitable for withstanding 105 deg C. Paint shall be RAL 7032 powder coated or as per the directives of engineer in charge.Allpanels must be designed, tested & manufactured as per IEC61439- 1 & 2 & IEC 61921 refrence standard. ( Panels shall be designed as per SLD attched ) |
| 385 | Providing, erecting & Supplying LT Panel 1 - 2 No. - 800 Amps each four pole horizontal drawout type air circuit breaker of fault breaking capacity 50 KA (Ics = Icu 100% up to 433 V) EDO fitted with interlocked door,automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators andframe earthing contact. confirming to IS :139472,1993 as amended up to date complete with following accessories for each ACB. Supplying and erecting 1No. ON LOAD four pole automatic transfer switch, 415V, 800A, 50 Hz with enclosure, flexibility of neutral connection, line and loadreversibility, changeover with phase barriers, source separator, terminal coversalong with staggered termination for cable connection and ATS controller withprovision of time delay protection of OV, UV, phase sequence changing, singlephasing and event logging, connected with provided leads complete complying toIS/IEC 60947-3 Part-1/6.Multifunction meter equivalent to conserv EM 6400 with RS-485 communication port.Phase indicating lamps backed upwith MCBON/OFF/Trip indicating lampon incomer feeder for indicating the status of feeder. Protective devices The Transformer incoming ACB shall be provided with the following protective devices.Combined Under voltage and over voltage relay ,3 Phase with Time delay setting. |
| 386 | Separate CT\"s shall be provided for protective system and measuring system. 2 no. of CT on Yellow phase for Automatic power factor correction relay onthe incomingbreaker. Bus Bar - 800 Amps TPN copper bas bar with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc for with standingfaultlevelof26MVA for 1second - 1set. All outgoing feeders shall be provided with one sets ofON/OFF lamps with protection MCB, and Ammeter 1 No of 630A, 4P,50 KA Microprocessor basedMCCB with built in overload, short circuit and instantaneous short circuit protection.The feeder shouldconsist of RYB LED lamps for phase indication and ON/ OFF /TRIP LED lamps (Red ,Green and Amber color).2 No of 400A, 4P,50 KA Microprocessor basedMCCB with built in overload, short circuit and instantaneous short circuit protection.The feeder shouldconsist of RYB LED lamps for phase indication and ON/ OFF /TRIP LED lamps (Red ,Green and Amber color). |
| 387 | Providing, erecting & supplying LT Panel 2 -1 No. - 630 Amps each four pole horizontal drawout type air circuit breaker of fault breaking capacity 50 KA (Ics = Icu 100% up to 433 V) EDO fitted with interlocked door,automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators andframe earthing contact. confirming to IS :139472,1993 as amended up to date complete with following accessories for each ACB. Multifunction meter equivalent to conserv EM 6400 with RS-485 communication port.Phase indicating lamps backed upwith MCBON/OFF/Trip indicating lampon incomer feeder for indicating the status of feeder. Protective devices - The Transformer incoming ACB shall be provided with the following protective devices.Combined Under voltage and over voltage relay ,3 Phase with Time delay setting.Separate CT\"s shall be provided for protective system and measuring system. 1 no. of CT on Yellow phase for Automatic power factor correction relay onthe incomingbreaker. Bus Bar - 630 Amps TPN copper bas bar with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc.All outgoing feeders shall be provided with one sets ofON/OFF lamps with protection MCB, and Ammeter |
| 388 | 1 No of 500A, 4P,50 KA Microprocessor basedMCCB with built in overload, short circuit and instantaneous short circuit protection.The feeder shouldconsist of RYB LED lamps for phase indication and ON/ OFF /TRIP LED lamps (Red ,Green and Amber color).8 No of 160A, 4P,25 KA Thermal Magnetic basedMCCB with built in overload, short circuit and instantaneous short circuit protection.The feeder shouldconsist of RYB LED lamps for phase indication and ON/ OFF /TRIP LED lamps (Red ,Green and Amber color).2 No of 100A, 4P,25 KA Thermal Magnetic basedMCCB with built in overload, short circuit and instantaneous short circuit protection.The feeder shouldconsist of RYB LED lamps for phase indication and ON/ OFF /TRIP LED lamps (Red ,Green and Amber color).1 No of 80A, 4P,25 KA Thermal Magnetic basedMCCB with built in overload, short circuit and instantaneous short circuit protection.The feeder shouldconsist of RYB LED lamps for phase indication and ON/ OFF /TRIP LED lamps (Red ,Green and Amber color).1 No of 80A, 4P,25 KA Thermal Magnetic basedMCCB with built in overload, short circuit and instantaneous short circuit protection.The feeder shouldconsist of RYB LED lamps for phase indication and ON/ OFF /TRIP LED lamps (Red ,Green and Amber color).1 No of 80A, 4P,25 KA Thermal Magnetic basedMCCB with built in overload, short circuit and instantaneous short circuit protection.The feeder shouldconsist of RYB LED lamps for phase indication and ON/ OFF /TRIP LED lamps (Red ,Green and Amber color).6 Nos of 63A, 4P, Miniature Circut breaker at 10 KA . |
| 389 | Providing , erecting & supplying UPS Panel 1 No of 125A, 4P,25 KA Thermal Magnetic basedMCCB with built in overload, short circuit and instantaneous short circuit protection.The feeder shouldconsist of RYB LED lamps for phase indication and ON/ OFF /TRIP LED lamps (Red ,Green and Amber color).The feeder should also consist of 100/5Amps CT\"s along with Load Manager.Multifunction meter equivalent to conserv EM 6400 with RS-485 communication port.Phase indicating lamps backed upwith MCBON/OFF/Trip indicating lampon incomer feeder for indicating the status of feeder. Protective devices The Transformer incoming ACB shall be provided with the following protective devices.Combined Under voltage and over voltage relay ,3 Phase with Time delay setting.Separate CT\"s shall be provided for protective system and measuring system. 1 no. of CT on Yellow phase for Automatic power factor correction relay onthe incomingbreaker. |
| 390 | Bus Bar - 160 Amps TPN aluminium bas bar with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc.All outgoing feeders shall be provided with one sets ofON/OFF lamps with protection MCB, and Ammeter 3 No of 100A, 4P,25 KA Thermal Magnetic basedMCCB with built in overload, short circuit and instantaneous short circuit protection.The feeder shouldconsist of RYB LED lamps for phase indication and ON/ OFF /TRIP LED lamps (Red ,Green and Amber color). |
| 391 | Providing, Supplying and erecting UPS Panel 2 -1 No of 100A, 4P,25 KA Thermal Magnetic basedMCCB with built in overload, short circuit and instantaneous short circuit protection.The feeder shouldconsist of RYB LED lamps for phase indication and ON/ OFF /TRIP LED lamps (Red ,Green and Amber color).The feeder should also consist of 100/5Amps CT\"s along with Load Manager.Multifunction meter equivalent to conserv EM 6400 with RS-485 communication port.Phase indicating lamps backed upwith MCBON/OFF/Trip indicating lampon incomer feeder for indicating the status of feeder. Protective devices The Transformer incoming ACB shall be provided with the following protective devices.Combined Under voltage and over voltage relay ,3 Phase with Time delay setting.Separate CT\"s shall be provided for protective system and measuring system. 1 no. of CT on Yellow phase for Automatic power factor correction relay onthe incomingbreaker. |
| 392 | Bus Bar - 125 Amps TPN aluminium bas bar with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc.All outgoing feeders shall be provided with one sets ofON/OFF lamps with protection MCB, and Ammeter 10 Nos of 63A, 4P, Miniature Circut breaker at 10 KA . |
| 393 | Providing, Supplying & erecting Floor Panel -1 No of 160A, 4P,25 KA Thermal Magnetic basedMCCB with built in overload, short circuit and instantaneous short circuit protection.The feeder shouldconsist of RYB LED lamps for phase indication and ON/ OFF /TRIP LED lamps (Red ,Green and Amber color).The feeder should also consist of 160/5Amps CT\"s along with Load Manager.Multifunction meter equivalent to conserv EM 6400 with RS-485 communication port.Phase indicating lamps backed upwith MCBON/OFF/Trip indicating lampon incomer feeder for indicating the status of feeder. Protective devices The Transformer incoming ACB shall be provided with the following protective devices.Combined Under voltage and over voltage relay ,3 Phase with Time delay setting.Separate CT\"s shall be provided for protective system and measuring system. 1 no. of CT on Yellow phase for Automatic power factor correction relay onthe incomingbreaker. |
| 394 | Bus Bar - 200 Amps TPN aluminium bas bar with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc.All outgoing feeders shall be provided with one sets ofON/OFF lamps with protection MCB, and Ammeter 2 No of 100A, 4P,25 KA Thermal Magnetic basedMCCB with built in overload, short circuit and instantaneous short circuit protection.The feeder shouldconsist of RYB LED lamps for phase indication and ON/ OFF /TRIP LED lamps (Red ,Green and Amber color).10 Nos of 40/63A, 4P, Miniature Circut breaker at 10 KA .5 Nos of 25/32A, DP, Miniature Circut breaker at 10 KA . |
| 395 | Supplying, erecting, testing & commisioning 250 kVAr, 3 phase, 50 Hz., APFC Panel with derated power contactor of suitable rating for capacitor switching Application for each step controlled by microprocessor based APFC relay consisting of 2,3,5,10,20,20,20,20 or suitable steps of MPP /APP type capacitorwith 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with detuned aluminium wound reactor of 7/ 14% for each step, APFC Panel shall suitable rating MCCB as incomer and each branch/step shall have separate isolation with MCCB/MCB of Suitable rating for protection, compliance to IEC 61439 and power quality IEC 61921 standard. |
| 396 | Fire Fighting Panel |
| 397 | Providing, Supplying and erecting Fire Fighting Panel -1 No of 400A, 4P,36 KA Micro-Processorc basedMCCB with built in overload, short circuit and instantaneous short circuit protection.The feeder shouldconsist of RYB LED lamps for phase indication and ON/ OFF /TRIP LED lamps (Red ,Green and Amber color).The feeder should also consist of 400/5Amps CT\"s along with Load Manager.Multifunction meter equivalent to conserv EM 6400 with RS-485 communication port.3 Nos. phase indicating lamps backed upwith MCBON/OFF/Trip indicating lampon incomer feeder for indicating the status of feeder. Protective devices Separate CT\"s shall be provided for protective system and measuring system. Bus Bar - 400 Amps TPN copper bas bar with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc.All outgoing feeders shall be provided with one sets ofON/OFF lamps with protection MCB, and Ammeter Providing & erecting 3No. 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magneticsetting with provided leads, provision for installation of shunt/UV/trip alarm contact.MCCB should have phase barriers both sides, with insulation withstand capacity 800V,no line-load bias in provided enclosure/panel as per specification no. SW-MCCB |
| 398 | Providing & erecting 4No. 4 Pole MCCB 415V, 63A, rated short-circuit breaking capacity 36kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magneticsetting with provided leads, provision for installation of shunt/UV/trip alarm contact.MCCB should have phase barriers both sides, with insulation withstand capacity 800V,no line-load bias in provided enclosure/panel as per specification no. SW-MCCBSupplying and erecting Star Delta Starter suitable for 415V. Three phase, 50 cycles with overload element with necessary materials and connected to supply upto 100 H.P. - 2 No.Supplying and erecting Star Delta Starter suitable for 415V. Three phase, 50 cycles with overload element with necessary materials and connected to supply upto 15 H.P. - 2 No. |
| 399 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no. CB-LT/AL |
| 400 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 240 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no. CB-LT/AL |
| 401 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no. CB-LT/AL |
| 402 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no. CB-LT/AL |
| 403 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no. CB-LT/AL |
| 404 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no. CB-LT/AL |
| 405 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no. CB-LT/AL |
| 406 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no. CB-LT/AL |
| 407 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no. CB-LT/AL |
| 408 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipeas per specification no. CB-LT/CU |
| 409 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipeas per specification no. CB-LT/CU |
| 410 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipeas per specification no. CB-LT/CU |
| 411 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipeas per specification no. CB-LT/CU |
| 412 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipeas per specification no. CB-LT/CU |
| 413 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipeas per specification no. CB-LT/CU |
| 414 | Supplying & laying (including excavation) reinforced cement concrete pipe of IS458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slopeincluding providing and fixing collars in cement mortar 1:2 and curing etc.complete. |
| 415 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 500 mm width & 100mm height comprising all required standard accessories. |
| 416 | Providing & erecting hot dipped galvanised perforated type cable tray manufactured from 16 SWG GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 417 | Providing & erecting hot dipped galvanised perforated type cable tray manufactured from 16 SWG GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 418 | Supplying, installation and testing of maintenance free earthing comprising ofElectrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon basedenvironment friendly back fill ground enhancing compound required to fill up theexcavated earth with required quantity complete, and recording the resultsSpecification no. EA-MOBI |
| 419 | Supplying and erecting copper strip of high purity required size used for earthingon wall and/or any other purpose with necessary copper clamps fixed on wallpainted with bituminous paint with joints required. As per specification no. EA-EP. |
| 420 | Supplying and erecting GI strip of high purity required size used for earthing onwall and/or any other purpose with necessary GI clamps fixed on wall paintedwith bituminous paint with joints required. As per specification no EA-EP. |
| 421 | Supplying and erecting GI wire of high purity of required sizes used for earthingor any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/conduit with screws complete. |
| 422 | Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipeerected on provided foundation complete. |
| 423 | Supplying, erecting, testing and commissioning 11KV HT metering cubical(compact / vertical type) approved by MSEDCL / licensee fabricated with 2mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating /epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening ofmeter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 10/5A to 50/5A, VA10 or 15, Class 0.5S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.5 suitablefor provided trivector meter, and provision for incoming and outgoing cable scomplete duly tested by licensee with necessary test certificates and erected onprovided plinth/ cc foundation. |
| 424 | Supplying, erecting, testing & commissioning 11 kV, 630A, 21kA/3sec, 3 wayoutdoor, extensible motorised SCADA compatible RMU, internal arc testedconsisting of 2 nos. feeder with 2 LBS and 1 no. feeder with 1 VCB. compliant toIEC 62271 -100, 200 and 102,as per specification no. SW-HTS/RMU SCADA |
| 425 | Supplying, installing, testing & commissioning compact substation with 3 phase, 11/0.433 kV, 50 Hz., 500 kVA, Mineral Oil immersed Copper wound, without gas cushioning , hermetically Sealed transformer having indoor type transformer bushings, with HT side (incoming side) load break switch of appropriate capacity and LT side (outgoing side) MCCBs (4 pole) of appropriate capacity , with inbuilt metering cubical, using type A winding insulation (kraftpaper), standard accessories complete with test certificate with losses below 1510 Watts at 50% load, 4300 Watts at 100% load for transformer, as per IS:1180(part 1) : 2014 , with necessary permissions of Electrical Inspectors perspecification no SS- TR-SL. |
| 426 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 500 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 81.90 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters,switchgears, indicators connected with suitable wires/cables, the complete setenclosed in composite Acoustic enclosure as fully assembled integral unit made of16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75dB at 1.0 m, provided with first filling of oil, diesel not less than 690 Ltr etc. onprovided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG |
| 427 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 400 kVA up to 500 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etcas per specification no. GEN-AMF. |
| 428 | Supplying, installing, testing and commissioning of 25 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 75Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate,canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB ,MCB etc. wiring up to solar Inverter in casing and capping, display board, signboard, two distinct earthing, lightning arrester, structure, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG. |
| 429 | Supplying and installation of Solar PV Module cleaning unit consisting of nozzles spray, necessary pipes, valves, post, electronic panel board concealed withweather proof cabinet, spreading water periodically for removal of dust, relatedmotor pump, controller, timer and nozzles set suitable for covering 25 KW Solar PV Module. (Approx. 35 Sq. Mtr. PV Module area). |
| 430 | Supply, Installation, testing & commissioning of 500 kVA, Automatic Voltage Stabilizer comprising following features:-a) Cooling-ONAN Typeb) Input Voltage:- 350 to 480Vc) Output Voltage:- 440V +1%d) Input Frequency:- 47 to 53 Hze) Control Type:- Digital Micro Controllerf) Correction Speed:- 70V per Secg) Auto/Manual Reset with time delay & programmedh) Electronic Overload & short circuit protectioni) Surge arresterj) Single phase preventionk) Digital metering at input & outputl) Input Voltage:- 380 to 480Vm) Audio alarm |
| 431 | Supplying and embedding of 75 mm wide X 40 mm deep x 1.6 mm thick sizes of underfloor trunking made up of minimum 1.6 mm thick Pre Galvanised / Hot dipped G.I sheet (minimum 275 GSM) including connecting pieces, floor fixing supports, chipping and levelling that portion of the floor etc in the floor in recess etc as per specifications complete as required. |
| 432 | Supplying and embedding of 100 mm wide X 40 mm deep x 1.6 mm thick thick sizes of underfloor trunking made up of minimum 1.6 mm thick Pre Galvanised / Hot dipped G.I sheet (minimum 275 GSM) including connecting pieces, floor fixing supports, chipping and levelling that portion of the floor etc in the floor in recess etc as per specifications complete as required. |
| 433 | Supplying and embedding of 150 mm wide X 40 mm deep x 1.6 mm thick thick thick sizes of underfloor trunking made up of minimum 1.6 mm thick Pre Galvanised / Hot dipped G.I sheet (minimum 275 GSM) including connecting pieces, floor fixing supports, chipping and levelling that portion of the floor etc in the floor in recess etc as per specifications complete as required. |
| 434 | Supplying and embedding of 225 mm wide X 40 mm deep x 1.6 mm thick thick thick thick sizes of underfloor trunking made up of minimum 1.6 mm thick Pre Galvanised / Hot dipped G.I sheet (minimum 275 GSM) including connecting pieces, floor fixing supports, chipping and levelling that portion of the floor etc in the floor in recess etc as per specifications complete as required. |
| 435 | Supplying and fixing 4 way junction box with height adjustable and fly over type of 150 x 150 mm sizes Hot Dip Galvanised Steel made out of minimum 1.6 mm thick sheet steel and top metal cover alongwith suitable vertical tap-off arrangement for drawing of Data, Telephone and Power cables from floor trunking including chipping and levelling that portion of the floor i/c site cover for junction box with powder coated as per direction of Engineer in charge etc as per specifications complete as required. |
| 436 | Supplying and fixing 4 way junction box with height adjustable and fly over type of 300 x 300 mm sizes Hot Dip Galvanised Steel made out of minimum 1.6 mm thick sheet steel and top metal cover alongwith suitable vertical tap-off arrangement for drawing of Data, Telephone and Power cables from floor trunking including chipping and levelling that portion of the floor i/c site cover for junction box with powder coated as per direction of Engineer in charge etc as per specifications complete as required. |
| 437 | Supplying and fixing 4 way junction box with height adjustable and fly over type of 225 x 225 mm sizes Hot Dip Galvanised Steel made out of minimum 1.6 mm thick sheet steel and top metal cover alongwith suitable vertical tap-off arrangement for drawing of Data, Telephone and Power cables from floor trunking including chipping and levelling that portion of the floor i/c site cover for junction box with powder coated as per direction of Engineer in charge etc as per specifications complete as required. |
| 438 | Supplying, erecting, testing and commissioning of 10kW, 3 x 3.3 KW AC Electric Vehicle charger (suitable for 2/3/4 wheeler) having minimum IK08/IP 54 Protection suitable for three phase, 415V AC, 50Hz incoming and 3nos. output as per IEC 60309 industrial sockets having capacity of outputcurrent of 16A 240V AC at each socket with 3.5\"TFT touch screen for human interface & LED Light for status indication and metering for measurement ofconsumed energy having metering accuracy +/-1%, one hour battery backup for communication, emergency push stop button and having short circuit, over & under voltage, overload, over temperature, earth leakage protection and enclosure made of minimum 1.5mm duly RAL7035 Coated M.S, Erected on iron/GI frameon provided cement concrete foundation complete with one year on site warranty, confirming toIS 17017 Series as per specification. |
| 439 | Fire Alaram System, PA System, CCTV, Rodent Repellent,etc. |
| 440 | SITC of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with XX Loops, expandable upto 4 loops even with 4 network port / card, and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.6 km, 8\" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking,200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . Also should be compitable with OPC/BacNet/Modbus protocol for BMS.Panel shall support hot swappable loop card.Panel should have option to connect with remote cloud services to have consolidated data dashboard for all networked connected panel along with mobile services. Cloud service Should be available by same panel OEM. have Vds/UL & FM Certification.Should have Vds/UL & FM Certification. |
| 441 | Supply, Installation, Testing and Commissioningof Active Repeater panel to be connected peer to peer with Main Fire Alarm panel. Accept, Reset functions shall be possible from the repeater panel. The HMI of the Main panel and the Repeater panel shall be similar including keypad.All other specification shall remain unchanged like FACP.Shallbe VdS certiifed. |
| 442 | Supply, Installation, Testing and Commissioning of intelligent addressable photoelectric smoke detector with two integrated light-scattering smoke sensors using 2 LEDs - blue & infrared. (Detector should comply to Test Fire 1). Detetctor should have 2 inbuilt isolators as per NFPA 72 style 7 wiring requirements and have an option of both soft & hard addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/ certification.(Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) |
| 443 | Supply, Installation, Testing and Commissioning of intelligent addressable Multisensor detector with two integrated light-scattering smoke sensors using 2 LEDs - blue & infrared. (Detector should comply to Test Fire 1). Detetctor should have 2 inbuilt isolators as per NFPA 72 style 7 wiring requirements and have an option of both soft & hard addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/ certification.(Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) |
| 444 | Supply, installation, testing and commissioning of Microprocessor Based Addressable Invisible detector for smoke, optical component, for flush fitting in steel-reinforced concrete ceiling or suspended ceilings. having a detection principle oftwo independent scatteirng light sensors with sensing volumes directly beneath the detectorwith features of drift compensation , contamination detection by means of a third optical system, protection aganist insects by means of a dual eveluation system , protection aganist external light in accordance with EN54-7 , chamber integrity monitoring, optical fault display , self monitoring of sensors, programmable for timed automatic sensitivity selections with Junction Box and other accessories as required. The detector shall be EN-54 Approved |
| 445 | Supply, Installation, Testing and Commissioning of addressable Heat detector with fixed andrate of raise feature including mounting base with LED… etc. complete as required.Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m.Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) |
| 446 | Supplying, installing, testing and commissioning of addressable firecontrol/relay module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs etc., Addressable Control Relay Module with inbuilt isolators as per NFPA 72 style 7 wiring requirements & with flexible network structures with a maximun switching current of 1A @ 30V DC. Shall beEN54/ Vds Certification/UL |
| 447 | Supply, Installation, Testing and Commissioning of Addressable Module with one input & one output contacts, with inbuilt isolators & with 2 monitoring features,monitoring of a line with EOL resistor ,Potential free contact monitoring.Shall be EN54 / Vds/UL Certification. Module for flow switches, Panic Bars & other Third Party Inputs |
| 448 | Supply, Installation, Testing and Commissioning of addessable manual break glass unit ( Double action) with inbuilt isolators as per NFPA 72 style 7 wiring requirements, with flexible network structures & necessary fixing arrangements with key complete as required. Shall be EN 54 / Vds/UL Certification. |
| 449 | Supply, Installation, Testing and Commissioning of Stand alone Loop Powered detector base sounder with inbuilt isolators as per NFPA 72 style 7 wiring requirements & with 32 different tone variants selection options & adjustable sound pressure by 5 levels, the sound pressure 92.1 dB(A), with flasher having Synchronized flash rate of 1 Hz and Light intensity > 2 cd, should be programmed from the panel. Shall be EN54 / Vds/UL Certification. |
| 450 | Supplying, installing, testing and commissioning of 2 X 1.5 Sq. MM FRLS Armored cable (Red Colour) |
| 451 | SITC of IP based Digital Public Address and Emergency Sound System Controller certified to International standards of Emergency Sound System EN 54and ISO 7240‑16, marked for CE and compliant with the RoHS directive. The system shall be fully IP-network based and all system devices shall communicate via IP, using an Audio over IP (AoIP) protocol that supports standards AES67 for audio and using AES128 for control with optional encryption and authentication to prevent unauthorized access, misuse and modification of data.It shall be capable of receiving Dante and AES67 audio streams. The audio part shall support Layer 3 connections via routers between subnets with latency of less than 10ms and synchronized outputs.The control data part shall be guaranteed by Transmission Control Protocol (TCP) Layer 4. The system shall support >100 simultaneous channels for music routing and making calls. A system based on a single system controller shall support at least 120 system devices and 500 zones.The system controller shall dynamically assign network audio channels for audio routing between system devices across multiple subnets. The system controller shall have dual power supply inputs and power supplies. It shall keep an internal log of fault events and call events.The system controller shall provide a secure TCP/IP open interface for remote control and diagnostics.The system controller shall provide front-panel LED indications for the status of power supplies and the presence of faults in the system upto 2000 faults and provide additional software monitoring and fault reporting features. The Controller should have provision of \"Hot redundancy\" i.e. in case of failure of working controller the standby controller should automatically take over the faulty duty controller. |
| 452 | SITC of IP based Digital Class-D multi channel Amplifier 600W each with 4 channels,The amplifier shall adapt the maximum output power of each amplifier channel to its connected loudspeaker load, with free assignable output power per channe.EN 54 certified and ISO 7240‑16, marked for CE and compliant with the RoHS directive.The amplifier shall have a built-in independent spare amplifier channel for automatic failover.The amplifier shall provide an interface for control data and multi-channel digital audio over IP using dual Ethernet ports for redundant network connection, supporting RSTP and loop-through cabling, with automatic failover to an analog lifeline input. The amplifier shall have dual power supply inputs and power supplies.All amplifier channels shall have independent A/B zone outputs with support for class-A loudspeaker loops.All amplifier channels shall supervise the integrity of connected loudspeaker lines without interruption of audio distribution.The amplifier shall provide front-panel LED status indications for the network link, ground fault, power supplies and audio channels, and provide additional software monitoring and fault reporting features. Audio‑over‑IP, using the high‑quality digital audio interface, compatible withAES67 and AES 70 standards with optional encryption and authentication to prevent unauthorized access, misuse and modification of data using an uncompressed, high-definition digital audio format with 24-bit sample size and 48 kHz sample rate.Digital signal processing on all amplifier channels, including equalization, limiting and delay, to optimize and tailor the sound in each loudspeaker zone |
| 453 | SITC of the IP based desktop call station for PA system operation. The call station shall be certified for EN 54‑16 and ISO 7240‑16, marked for CE and be compliant with the RoHS directive.Desktop housing with gooseneck microphone. 4.3\" full‑color capacitive touch display .It shall provide control and routing of live speech calls, stored messages and music with volume control per zone.. Graphical user interface for optimum user guidance and feedback.Status and fault indicators for voice alarm purposes.Dual Audio over IP‑network ports for redundant network. The audio over IP should comply AES 67 standard for audio and AES 70 for control with optional encryption and authentication to prevent unauthorized access, misuse and modification of data.It shall receive Power over Ethernet (PoE) via either one or both network connections. |
| 454 | 6W ceiling mount speaker with excellent speech & music reproduction- Max Power: 9W,Rated Power: 6Watts, Power Tapping: 6/3/1.5/0.75W- Effective frequency range(-10 dB) :90 Hz to 20KHz- SPL at rated power (1Khz at 1 m) 98 dBBS 5839‑8 /* EN 54‑24 / EN 60849 |
| 455 | - 6W Cabinet mount speaker with excellent speech & music reproduction- Max Power: 9W,Rated Power: 6Watts, Power Tapping: 6/3/1.5W- Effective frequency range(-10 dB) : 180 Hz to 20KHz- SPL at rated power (1Khz at 1 m) 89 dB- EmergencyAccording to EN 54-24, Self-extinguishingAccording to UL 94 V 0 |
| 456 | Seamless Integration with FA System |
| 457 | Supplying, installing, testing and commissioning of 2 X 1.5 Sq. MM FRLS Armored cable |
| 458 | 2MP IP Varifocal Dome Camera: Supply of1080p Indoor Dome camera with 1/2.8‑inch CMOS, Effective pixels 1920 x 1080 (2MP), 60 frames per second Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE) Color 0.0225 lx Mono 0.0051 lx With IR 0.0 lx, 146dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens,MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 45 mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G &T, PoE, CE, FCC , UL certified. SD card support up to 2TB. All camera should be able to generate trigger for atleast 8 to 10 analytics simultaneously from above mentioned analytic rules etc complete as per direction of EIC / PMC. |
| 459 | 2MP IP Varifocal Bullet Camera: Supply of 1080p IR Bullet camera with 1/2.8‑inch CMOS, Total sensor pixels 1920 (H) x 1080 (V); 30fps Sensitivity – Measured according to IEC 62676 Part 5 (1/30, F1.6), Color 0.06 lx, Mono 0.016 lx, With IR 0.0 lx, 120dB WDR, H.265; H.264; M- JPEG, Automatic Electronic Shutter (AES); Intelligent Dynamic Noise Reduction, Intelligent Defog, Rule based alarms and tracking, Line crossing, Enter / leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Speed, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks) Privacy Masking, Pixel counter, Memory card slot, IR Range 30mtr, Automatic Varifocal 3.3 mm – 10.2 mm, Alarm Input 1/1, Audio Input/output, RJ45, G.711, Audio Streaming Full-duplex / half duplex, ONVIF Profile S, G & T, IP66, IK10, PoE, CE, FCC, UL certified. SD card support up to 2TB.FTP, Dropbox and e-mail applications. All camera should be able to generate trigger for atleast 8 to 10 analytics simultaneously from above mentioned analytic rules etc complete as per direction of EIC / PMC. |
| 460 | Supply of all-in-one recording, viewing and management solution for network surveillance systems for up to 256 channels, Pre-installed, pre-configured IP storage solution, with RAID-5/RAID-6 protected, Dedicated storage operating system delivers robust , secure operation, Hot-swappable hard drives, Advanced user and alarm management,Intel® Core™ i7-12700E (25 MB Intel® Smart Cache 2.10 GHz)Processor,16 GB DDR5,ECC UDIMM memory installed, 3U rack mount, 16 Trays: 3.5-inch SATA 3; max 18TB per HDD slot maximum supported, 12Gb/s SAS RAID Card, 4 USB ports; Intel onboard graphics (Intel® UHD Graphics 770),Microsoft Windows Server IoT 2022 for storage standard,UL, CE Certified. 2 x RJ45 Gigabit Ethernet LAN ports (teamed); 1 IPMI BMC port.Operating temperature (°C) 0°-40°C; Operating relative humidity, noncondensing (%) 8 - 90%. |
| 461 | 12TB Surveillance Hard Disk |
| 462 | 55\" LED Monitor for 24x7 Operation |
| 463 | 16 Port PoE Switch with SFP modules. 16 Port PoE Switch with 2 Fibe Module. 16 10/100/1000 Mbps ethernet Ports. IEEE 802.3af/at compliant. 150W Total power budget. Up to 30W Power output per PoE Port. |
| 464 | PC workstation for CCTV (as per OEM) |
| 465 | 6U Network Rack |
| 466 | 12U Network Rack |
| 467 | Supplying, installing, testing and commissioning of Cat 6 Cable with conduit including accessories |
| 468 | Note - As a part of Testing & Commissioning process the vendor is required to demonstrate the following:a. Capture,Record and Report (in pdf format) One Third Octave Ultrasound Band Frequencies emitted from the transducers thereby ensuring HUMAN SAFETY as per IRPA (International Radiation Protection Association, Geneva) Guidelines. b. Capture,Record and Report (in pdf format) ultrasound output from each transducer depicting individual frequency peaks along with corresponding sound pressure levels, current operating band and the Controller Name for verifying the product. |
| 469 | SITC of Microprocessor based Master Controller with 128X64 Graphic LCD DISPLAY capable of operating in5 ultrasonic frequency band spectrums. The LCD should display oscillation between these freqency bands in a graphical format. The controller should also support upto 20 transducers @ minimum 400 sq.ft each and networkable on RS 485 having facility to support Hardwired Third Party BMS integration via Modbus & potential free NO-NC contacts. The system shall use UL and CE approved transformers for power supply. |
| 470 | SITC of transducer should cover a minimum of 400 sq.ft in all voids and to have dedicated connection with the controller. No Looping permitted. |
| 471 | Testing, Commissioning & Verification Kit comprisingof Ultrasound Wave Analyzer (Software and Hardware) that can do the following:a. Capture,Record and Report (in pdf format) One Third Octave Ultrasound Band Frequencies emitted from the transducers thereby ensuring HUMAN SAFETY as per IRPA (International Radiation Protection Association, Geneva) Guidelines. b. Capture,Record and Report (in pdf format) ultrasound output from each transducer depicting individual frequency peaks along with corresponding sound pressure levels, current operating band and the Controller Name for verifying the product. |
| 472 | GUI Software capable of supporting:• Real Time Graphical Representation of the ultrasonic frequency band spectrum depicting the frequency oscillations within the current band.• Facility to generate a consolidated pdf summary report of all controllers or detailed pdf report ofindividual controller in real time or in a pre defined schedule.• Parameter Configuration of the controller.• PCB view of each controller. |
| 473 | Supply and laying 2C x 14/40 SWG Copper Cable of 0.5 sq.mm in thesurface/ recessed medium class PVC conduitISI marked along with PVC saddles and required accessories as required. Rate to include cost of conduit |
| 474 | Bracket ( MS Powder Coated ) |
| 475 | Supply and laying 3C x 1.0 Sq.mm Copper screened flexible Cable in thesurface/ recessed medium class PVC conduitISI marked along with PVC saddles and required accessories as required. Rate to include cost of conduit. |
| 476 | Fire Fighting System Works |
| 477 | Supplying, installation, testing and commissioning of main fire pump (MFP /EP) suitable for water discharge of 2280 to 2850LPM at 80 to 60 m headdriven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 45kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation boltsetc. as required. (d) Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire redcolour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP. |
| 478 | Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP. |
| 479 | Supplying, installation, testing and commissioning of booster fire pump [BP]suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP |
| 480 | Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.b(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP |
| 481 | Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP |
| 482 | Supplying and erecting ISI mark GI pipe 32 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP. |
| 483 | Supplying and erecting ISI mark GI pipe 40 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP. |
| 484 | Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP |
| 485 | Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP |
| 486 | Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP |
| 487 | Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP |
| 488 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP |
| 489 | Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP |
| 490 | Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system. |
| 491 | Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system. |
| 492 | Providing coating of bitumen paint & 4mm thick wrapping for underground 200 mm ring main of fire fighting system. |
| 493 | Supplying and erecting 75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 494 | Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 495 | Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 496 | Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, screen of SS end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 497 | Supplying & erecting cast iron double flange butterfly valve of size 50 mm dia. complete as per specification no. FF-VL/BFV |
| 498 | Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 499 | Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 500 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 501 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 502 | Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 503 | Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 504 | Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 505 | Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 506 | Supplying and erecting 200 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 507 | Supplying and erecting 20 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 508 | Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 509 | Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 510 | Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 511 | Supplying gun metal double outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 512 | Supplying and erecting 63mm dia, controlled percolation (C.P.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/CPH |
| 513 | Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specificationno. FF-FFA/RRL |
| 514 | Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV |
| 515 | Supplying and erecting gun metal branch pipe of 63 mm dia fitted with 20mm dia detachable hexagonal nozzle complete as per specification no. FFFFA/NZ. |
| 516 | Supplying and erecting 19 mm dia gun metal chrome plated nozzle complete as per specification no. FF-FFA/NZ |
| 517 | Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC |
| 518 | Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FMC |
| 519 | Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT |
| 520 | Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser completeas per specification no. FF-FFA/ARV |
| 521 | Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG |
| 522 | Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 523 | Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP |
| 524 | Supplying and erecting brass orifice plate having 6 mm. thickness, 160 mm outer dia with required diameter of inner hole at every double outlet hydrant valve as per specification no. FF-FFA/OP |
| 525 | Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve of size ( 400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200)mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 526 | Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8\" x 6\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 527 | Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8\"x6\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 528 | Providing & Fixing testing & Commissioning of two-piece adjustable type concealed pendent Sprinkler with qartzoid bulb operating temperature 68/79 degree centrigrade of 15mm dia Orfice and K factor 80(5.6), along with accessories as reqd. all complete as per the engineer incharge. |
| 529 | Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FFSPR. |
| 530 | Supplying, erecting, testing and commissioning vane type water flow detector 75/80 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. |
| 531 | Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. |
| 532 | Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM. |
| 533 | Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. |
| 534 | Supplying and erecting D.C.P. type fire extinguisher 9 kg capacity cartridge type with Gun Metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985 and complete erected with necessary clamps made from 50x6 mm M.S.flat with nuts & bolts grouted in wall complete. |
| 535 | S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected withnecessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 536 | Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete. |
| 537 | Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete. |
| 538 | Providing & Fixing of ABC modulartype FireExtinguisher,ceiling mounted 10 KG. Capacity, complete in all respect.(automatic) At 68 DegC. |
| 539 | Supplying and erecting wall hook 225mm projection for keeping fire buckets made out of 15 mm dia. M.S. Rod grouted in wall to a depth of minimum 15cms complete. |
| 540 | Supply & Fixing ofrossette plate for pendant type Sprinkler with all the required accessories & fittings. |
| 541 | Providing, fixing, testing and commissioning ofInstallation Control Valve with turbine type automatic Alarm Gong to be connected with control valve, drain & test valve and all other necessary components as per manufacturer\"s specifications complete as required. |
| 542 | Supply & Instalation of Self Glowing nonreflective Type Sinages, made of 1.2 mm thick Rigid Plastic for Indoor / Outdoor Aplication with Green Background & white Text in satin finish. Text should be in portrait oreintation & Fixing of Sinages should be Permanent self adhesive type manifesting following Text as given below. |
| 543 | Manual Call Point (MCP)- 9\" x 9\" |
| 544 | Fire Exit -12\"x 6\" |
| 545 | Assembly point -38\"x38\" |
| 546 | Fire Extinguisher-9\" x 9\" |
| 547 | Fire Pump Room-38\"x38\" |
| 548 | Directional Arrow-12\"x 6\" |
| 549 | Supplying and erecting GI strip of required size used for earthing onwall and/or any other purpose with necessary GI clamps fixed onwall painted with bituminous paint in an approved manner with jointsrequired. As per specification no EA-EP. |
| 550 | Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CBLT/CU |
| 551 | Providing and laying Self contained compressed air breathing apparatus sets of 45 minutes duration each shall be kept in the fire control room/refuge area |
| 552 | Supply and installation of two way switches at 2 position for the main all the fire pumpsas requested in the Fire NOC with all the required wiring,conduits,box & accessories etc. Emergency Start / Stop Push Button station, weather proof type for Fire pumps at Ground Floor level..with all the reuired accessories & fittings arrangements etc. |
| 553 | Supply and installation of two way switches at 4 position for the booster pumps as requested in the Fire NOC with all the required wiring, conduits, box & accessories etc. Emergency Start / Stop Push Button for Fire pumps.weather proof type for Fire pumps at Refuge floor and Terrace level. with all the reuired accessories & fittings arrangements etc |
| 554 | HVAC Works |
| 555 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC |
| 556 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete |
| 557 | Supplying, erecting, testing and commissioning of 16HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 35° C, non stop cooling even at 52° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, its also include the lifting and shifting of ODU to terrace etc. all housed in powder coated weather proof cabinet complete. |
| 558 | Supplying, erecting, testing and commissioning of 18HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 35° C, non stop cooling even at 52° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, its also include the lifting and shifting of ODU to terrace etc. all housed in powder coated weather proof cabinet complete. |
| 559 | Supplying, erecting, testing and commissioning of 20HP, VRF/VRV air conditioning system out door unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 35° C, non stop cooling even at 52° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, its also include the lifting and shifting of ODU to terrace etc. all housed in powder coated weather proof cabinet complete. |
| 560 | Supplying, erecting, testing and commissioning of 22HP, VRF/VRV air conditioning system out door unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 35° C, non stop cooling even at 52° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, its also include the lifting and shifting of ODU to terrace etc. all housed in powder coated weather proof cabinet complete. |
| 561 | Supplying, erecting, testing and commissioning of 24HP, VRF/VRV air conditioning system out door unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 35° C, non stop cooling even at 52° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, its also include the lifting and shifting of ODU to terrace etc. all housed in powder coated weather proof cabinet complete. |
| 562 | Supplying, erecting, testing and commissioning of 26HP, VRF/VRV air conditioning system out door unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 35° C, non stop cooling even at 52° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, its also include the lifting and shifting of ODU to terrace etc. all housed in powder coated weather proof cabinet complete. |
| 563 | Supplying, erecting, testing and commissioning of 28HP, VRF/VRV air conditioning system out door unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 35° C, non stop cooling even at 52° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, its also include the lifting and shifting of ODU to terrace etc. all housed in powder coated weather proof cabinet complete. |
| 564 | Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.8TR (594 cfm) to 2.2TR (655 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. |
| 565 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indoor unit (IDU) compact/standard size of nominal cooling capacity 0.6TR ( 420 cfm )/0.8TR ( 441 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 566 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 1.0TR ( 441 cfm ) to 1.3TR (512 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 567 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 1.5TR (512 cfm) to 1.8TR (618 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 568 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 2.0TR (618 cfm) to 2.3TR (671 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 569 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oilcharge as per requirement during installation. |
| 570 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 571 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.3TR (1165 cfm) to 4.0TR (1218 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 572 | Supply, installation, testing and commissioning wireless remote control having colour LCD panel, real time clock, temperature limitation (16 to 30° C, functions like filter clean reminder timer suitable to communicate with wired controller complete. |
| 573 | Supplying, erecting, testing and commissioning centralised programmable remote control panel (HMI) touch manager controls minimum 16 system of 64 ODU\"s can be controlled and up to 992 IDU\"s can be individually mounted and controlled indoor units having colour min 200mm size LCD touch panel, yearly schedule, power proportional distribution function, temperature limitation, history function complete erected on wall integrated with provided fire alarm system. |
| 574 | Supply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete. |
| 575 | Supply, fabrication, installation an testing of flexible canvass connections constructed between ductable unit/dampers/ducting of suitable size with fire resist flexible double canvas sleeve complete. |
| 576 | Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-2017. |
| 577 | Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnut complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system. |
| 578 | Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 41.3mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 579 | Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 580 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 581 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete. |
| 582 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 583 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 584 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 585 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 586 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 587 | Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF |
| 588 | 2C X 1 sqmm Communication shielded Cable |
| 589 | GSS Ducting:- Supplying fabrication installation testing and commissioning of GI. Sheet metal ducting. Zinc coated. Complete with all Standard Accessories, G.I.. Hardware, Self Adhesive elastomeric foam gasket, Support etc as per SMACNA specification. |
| 590 | GSS Ducting:- 20 SWG |
| 591 | GSS Ducting:- 22 SWG |
| 592 | GSS Ducting:- 24 SWG |
| 593 | Supply & Installation of MS stands for VRF / ductable / package AC outdoor units. |
| 594 | Providing, fixing & erecting MS structure for AC outdoor & Indoor works etc complete as per direction of EIC / PMC |
| 595 | Providing and fixing 6.4mm dia(OD) (Softdrawn) with tube thickness 1.2m with 19mm thick insulation etc complete as per direction of EIC / PMC |
| 596 | Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. |
| 597 | Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. |
| 598 | Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. |
| 599 | Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. |
| 600 | Fire damper |
| 601 | Actuators |
| 602 | Refrigerant : Supply and additional refrigerant charge of refrigerant R32/ R410A to compensate the additional piping done at site for all systems including testing commissioning as required. |
| 603 | Power cables : Supply, installation, testing and commissioning of Power Cables for VRV/ VRF Units. |
| 604 | MCCB to Outdoor Unit Termination |
| 605 | 3 pin plug to Indoor Unit Termination |
| 606 | Drain piping: Providing and fixing of Hard PVC drain water piping with fittings, support and insulated with 6mm thick closed cell elastomeric nitrile rubber insulation complete as per specifications |
| 607 | 25mm dia ID |
| 608 | 32mm dia ID |
| 609 | 40mm dia ID |
| 610 | 50mm dia ID |
| 611 | Round GSS Ducting:-Supplying fabrication installation testing and commissioning of 24 SWG GI. Sheet metal ducting .Zinc coated. Complete with all Standard Accessories, G.I. .Hardware, Self Adhesive elastomeric foam gasket, support etc as per SMACNA specification. |
| 612 | FLEXIBLE PRE INSULATED DUCT :- Supply and fixing of aluminum foil flexible pre insulated duct. |
| 613 | 100 mm |
| 614 | 150 mm |
| 615 | Acoustic Insulation: Supply & Installation of Inner Lining of supply air duct with 10 mm thick class \"O\" open cell nitrile rubber,density 140 kg/cum. |
| 616 | EXTERNAL DUCT INSULATION :- Supplying & fixing of following 25mm thickness of mat finish closed cell nitrile rubber (Class \"O\") insulation along with company fitted weather proof UV protected glass wool cloth for protection of weather conditions and mechanical damages to insulation on existing duct after applying two coats of cold setting adhesive complete as per the specifications as required. |
| 617 | Underdeck Insulation: Supply & Installation of Underdeck Insulation of roof / ceiling with min. 25mm thick nitrile rubber closed cellinsulation / 40 kg/m3 density & fire rating class Ol duly fixed with GI washers. |
| 618 | Supply, Installation, Testing and Air Balancing of Extruded Aluminium Powder Coated Disc Valve complete in all respects as per specifications |
| 619 | Dia. 100 mm Disc valves for Toilet exhaust |
| 620 | Dia. 150 mm Disc valves for Toilet exhaust |
| 621 | Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°. |
| 622 | Supply and erecting aluminium powder coated linear grill of following sizes with collar dampers having mathcing colour with the existing false ceiling. |
| 623 | 150mm x 150 mm |
| 624 | 200mm x 200 mm |
| 625 | 300mm x 300 mm |
| 626 | 600mm x 600 mm |
| 627 | Supply, installation, testing and commissioning of low noise Cabinet Type inline fans with motor duly installed in single skin box with fire retardant flexible connection both side, vibration isolator and inspection windows etc. as per specifications and schedule of equipment suitable to install in duct work. |
| 628 | 800 CFM@ 30 mm st. pr. for Grd. Flr. Preparation area |
| 629 | 850 CFM@ 30 mm st. pr. for Grd. Flr. Store Room |
| 630 | 1100 CFM@ 35 mm st. pr. for Grd. Flr. Hazardous Lab Room & 1st Flr. Incubation Room. |
| 631 | 1200 CFM@ 30 mm st. pr. for 1st. Flr. Preparation area |
| 632 | 1900 CFM@ 30 mm st. pr. for Electrical Room |
| 633 | 2500 CFM@ 30 mm st. pr. for General Waste Water Lab & House Keeping |
| 634 | 3050 CFM@ 30 mm st. pr. for River Waste Water Lab & Record Room |
| 635 | Supply & fixing of Extruded Aluminium powder coated Non Vision Transfer air Grilles in Doors with telescopic frames and V Shaped blades. Frame with flat frontal face of 30 mm and V type sight proof fixed louvers. Single Frame type. |
| 636 | Supply, Installing, testing and commissioning ofPowder coated extruded aluminium construction fresh air/ Exhaust air louvers with min. 60 % free area, bird screen and volume damper as per specifications. Louvers need to be suitable in order to avoid rain water entry @ 45 degree deflection. As per technical specifications with all the necessary mounting accessories as required for complete installation. |
| 637 | Supply, installation, testing and commissioning of low noise Cabinet Type inline fans with motor duly installed in single skin box with fire retardant flexible connection both side, vibration isolator and inspection windows etc. as per specifications and schedule of equipment suitable to install in duct work. |
| 638 | 600 CFM@ 35 mm st. pr. for Grd. Flr. Preparation area & Kitchen |
| 639 | 700 CFM@ 35 mm st. pr. for Grd. Flr. Store Room |
| 640 | 850 CFM@ 35 mm st. pr. for 1st. Flr. Preparation area |
| 641 | 1520 CFM@ 35 mm st. pr. for Electrical Room |
| 642 | 2650 CFM@ 35 mm st. pr. for River Waste Water Lab & Record Room |
| 643 | 3900 CFM@ 35 mm st. pr. for Hot Rooms with VFD |
| 644 | Supply, installing, testing and commissioning of following capacities of ducted inline centrifugal fan as per specification and complete withsuitable 1 phase Motor with 3 speed control,bird screen, with fire retardant flexible connection both side etc. and complete as per technical specifications with all the necessary mounting accessories as required for wall or ceiling mounting for complete installation. |
| 645 | 500 cfm/ 20 mm st. pr Exhaust air fan for Gas Cylinder Storage |
| 646 | 700 cfm/ 20 mm st. pr Exhaust air fan for Toilet Block |
| 647 | 700 cfm/ 40 mm st. pr Exhaust air fan for 5th Flr. Kitchen & Pantry |
| 648 | 750 cfm/ 20 mm st. pr Exhaust air fan for Toilet Block |
| 649 | Supply, installation, testing and Commissioning of Smoke spill Tube Axial flow extract air fans rated for 250 Deg. C @ 2 hrs, along with silencers on inlet and outlet of below mentioned capacities, pressure casted Aluminium impeller blades, GSS Tube Casing, fixed speed Motor mounted onspring mounted vibration isolator, with supporting arrangement. The motor shall be TEFC type with H Class insulation & IP 55 protection, suitable for 415 V/3 ph/ 50 Hz, MS channel base, housing, fire retardant flexible connection with nut bolts at outlet, mounting, vibration isolators,& bird screen, etc.as per the specification given in the tender. All electrical panels shall be BMS Compatible.The fans shall be tested in accordance with BS 7346 Part 2 : 1990 & shall meet the performance criteria for class B, C and D as defined in BS Standard. |
| 650 | 4500 cfm, 35 mmwg external static pressure, fan speed 1450 rpm to exhuast air to ambient through shafts. Necessary transition piece and canvas connection for proper installation to be included in the scope. |
| 651 | Supply, installing, testing and commissioning of 150 cfm capacities of Ceiling Mount Exhaust Air Fan |
| 652 | Supply and Installation of GI Cowl Piece for Fresh / Exhaust air fans with MS Bird Screen. |
| 653 | Cold Storage Unit |
| 654 | MODULAR WALK IN COLD COLD ROOM - SIZE - as detailed below: The cold storage facility shall have a walk-in storage room and to be cooled with single cooling unit. The facility shall have microprocessor based control system located at one place. The cold storage should be of robust design, easy in operation and trouble free service. The cold storage facility should be able to work continuously at the ambient temperature and humidity at preset temperature. The cold storage should be fitted with suitable door for easy entry/exit of store personnel. The door should be provided with lock. Entire cold room facility shall be as per specification.Room Size ( Internal ) - 3.2(D) x 3.2 (W) x 3.6 (H) m.PRE-FABRICATED MODULAR COLD ROOM PANELS : Pre-fabricated panels with 0.6 MM interior and exterior 0.5 MM thick pre-painted GI sheets precisely formed with steel dies and rollform equipment, confirming to I.S.12346. The panels “foamed-in-place” with CFC free RPUF with a 97% closed cell structure should not have internal wood, metal or high-density urethane structural members. All joints should be airtight and vapor proof, with all panel edges having a tongue and groove edge of the same density as the rest of the panels.Panels to lock together with cam lock mechanism and joints finished using good quality silicon sealant . No timber should be incorporated with the construction. |
| 655 | Flexible vinyl gasket,resistant to damage from oil, grease, water, detergents and sunlight which is also “foamed-in-place”, should be provided around the interior and exterior perimeter of each male edge complete as per specificationWall Panel- Cold room, Ceiling Panel (Self Suppoting) for cold room, Floor insulation for cold room, Cold room door complete as per specification.LIGHTING : Internal sealed fluorescent lighting mounted flush with ceiling, programmable through the control Panel.AIR COOLED CONDENSING UNITS :Supply of suitable capacitycondensing unit. The unit shall compriseofsemihermeticScrollorreciplCompressor,Aircooledcondenser&Condenserfan. Compressors shall be cut-off automatically under part load conditions. The units shall have microprocessor controls. The units shall be factory assembled and only the Refrigerant piping carried out at site. The operating refrigerant should be R-404A and complete as per specification.EVAPORATORINDOORUNIT:SupplyofsuitablecapacityWallmountedIndoor Evaporator Unit . The indoor units shall be ceiling suspended type. The Indoor unit shall comprise of Fan, Cooling coil, Filter and Expansion device.A Ceiling mounted forced air- cooling unit constructed with SS sheet panels and should be assembled to form a rigid structure. Cooler surface should be assembled to form copper tubes and Aluminum fins mechanically bound in place; complete with condensate drip tray at the base with drain line connection complete as per specification. |
| 656 | REFRIGERANT PIPING FOR DUCTABLE SPLIT UNITS : Supply, Installation and Testing of soft drawn Copper Refrigerant piping and fitting using brazed joints,complete with 19 mm thick tubular elastomeric nitrile rubber EPDM insulation and finished with glass cloth (microban) . The refrigerant piping shall be adequately sized to take care of the length of piping.Complete piping workmanship to be carried out as per recommended practice. The piping to be vacuum tested and leak tested. Scope includes all refrigerant pipes shall be properly supported and anchored to the building structure using steel hangers, anchors, brackets and supports etc which shall be fixed to the building structure by means of inserts or expansion shields of adequate size and number. Quantity indicates per running meter of both suction and liquid line.REFRIGERANT GAS :Supply and Charging ofR-404A refrigerant gasDRAIN PIPING : Supply, Installation and Testing of Hard PVC drain piping insulated out of nitrilerubber material of approved make as per specification complete with supports, consumables, fittings, pipe sleeves, U trap, leak arresting of following sizes. |
| 657 | CONTROLLER AND DISPLAY SYSTEM : The unit is fitted with a micro-processor based digital electronic temperature controller cum indicator for easy readability along with audio-visual alarm system. The controller should have the facility to set temperature and humidity value and also the safety limits for temperature and humidity. The temperature control to be within +/- 10C at the sensing point. An audible alarm should be provided in the event of actual values exceeding the set limits, connected to the main building and security guard room. In the event of failure of the main mechanical refrigeration system or dehumidification device, the switch over to standby system should be automatic with indication of failure of main system.In the event of power failure,module should have delayed start in a sequesnce so that power lines are not loaded.FABRICATED STEEL WORK :Supply, Fabrication , Cutting, Welding , Erection at site and cold compound zinc coating of M. S. Angle supportwork for outdoor unit location.Electrical work comprising of necessary SFU/ starter for the indoor and outdoor units along with suitably sized cable and earthing from SFU to starter and up to motor. (Note: Only incomig cable along with earthing will be provided by electrical contractor at the SFU wherever you require at one place) |
| 658 | ETP & UV Water Filters |
| 659 | SITC of 15 KLD ETP Physico - Chemical Treatmentcomprising of Coarse Screen, Oil & Grease Traps, Sand Filter & Carbon Filter System with pumps. Waste Watre recycle pumps, Poly Dosing & Poly dosing Pumps With Tank. Alum Dosing & Alum dosing Pumps With Tank, with Tertiary Treatment & Electrical Control Panel, with all the required pre-fabricated tanks, pumps, piping, control valves, gauges, flow meters, differential pressure switches, pressure switches, Hi-Low sensors, solenoid valve, cables, termination, breakers, all the fixing arrangement & accessories etc.Design flows and Characteristics of Sewage Before Treatment :Flow - 15 KL/DayPh - 6.5-7.5BOD - 50 mg/lCOD - 300 mg/lTSS - 50 mg/lOil & Greese - 10 mg/l Expected Treated Sewage Quality :Typicaltreated sewage qualities from unit are as follow (Maximum Values):Flow - 15 KL/DayPh - 6.5-7.5BOD - 10 mg/lCOD - 50 mg/l |
| 660 | SITC ofSS 316Automatic Centralized Ultra Voilate Water Filter cf5 m3/hr Capacity suitable for maximum pressure of 20 bar,240 Grit (0.42 Ra Micron (µm)) Internal Surface Finish with low pressure amalgam (LPAM) lamp technology for maximum power density & efficiency, with all neceaasry control indication and Alarm. |
| 661 | SITC ofSS 316Automatic Centralized Ultra Voilate Water Filter cf10 m3/hr Capacity suitable for maximum pressure of 20 bar,240 Grit (0.42 Ra Micron (µm)) Internal Surface Finish with low pressure amalgam (LPAM) lamp technology for maximum power density & efficiency, with all neceaasry control indication and Alarm. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail