| 1 | Running Maintenanc & Operation of fire fighting system,fire alarm system & PA system and CCTV System, EPABX System & IEI at community hall in different pockets i.e A,B-1,B-2,C & D &DDA Project office (Loknayakpuram ) Bakkarwala as per inventory attached. a. Wiremen -1 no. for 52 days (Once in week or whenever is required)b. Khallasi - 1 no. for 52 days (Once in week or whenever is required) |
| 2 | Running Maintenance & Operation of sewage pump sets and cctv at Sewage Pump House as per inventory,terms and conditions attached.a. Wiremen -1 no. for 52 days (Once in week or whenever is required)b. Khallasi - 1 no. for 52 days (Once in week or whenever is required)c. Operator -2 no. for 368 days (1 no. in morning shift and 1no. in evening shift) |
| 3 | Running,operation & Maintenance ofexisting street lights on upto 12 mtr height poles completewith feeder pillers,switchgears,pole boxes, copper wires & distribution cables etc in various locations as per inventory with tower and wagon whenever required .a. Wiremen -1 no. for 104 days (Twice in week or whenever is required)b. Khallasi - 1 no. for 104 days (Twice in week or whenever is required) |
| 4 | Repairing of 40 HP Sewage Pump Set i/c Supply & Replacement of following worn out part i/cdismantling & reerrection cartagage etc as required. S/R of of shaft Sleeve-1No. |
| 5 | S/R of of Ball Bearing -2 Nos. |
| 6 | S/R of of S.S Shaft -1 No. |
| 7 | S/R of of Impleller Nut -1 No. |
| 8 | Providing and fixing following ratng and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel ,making connections etc.as required .a) 400 A, 50 KA, FP MCCB |
| 9 | Supply and replacementthe 18 watt LEDbatten (4 feet) suitable for 200-240 volts ,50Hz ACcomplete in all respect ,numbering ,connection,testingetc. as required i/c rebate on existing LED fitting. |
| 10 | Supply,replacement , Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85,Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 11 | Supplyand drawingof following sizes FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class steel conduit as reqd.3X 1.5 sq.mm |
| 12 | 3 X4 sq.mm |
| 13 | Supply & replacement of following piano type switch / socket on the existing switch box/ cover i/c connection etc. as reqd.(a) 5/6 Amps switch |
| 14 | (b) 15/16 Amp. Switch |
| 15 | (c) 3 pin 5/6 Amp. socket outlet |
| 16 | (d) 6 pin 15/16 Amp socket outlet |
| 17 | Providing, laying and replacement ofM25 reinforced cement concrete foundation of size 750 mm (L) x 1000 mm (D) and 750 mm (W) after removing the 12 m polei/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia. 1200 mm long (approx.) – atleast 10 Nos. and reinforcement ring of cold twisted bar of 10 mm dia. 3000 mm long (approx.)- atleast 8 Nos. (with 150 mm spacing) i/c supplying of 4 Nos. M-24 x 750 mm long (150 mm top threaded & 650 mm top galvanized portion) M.S foundation bolt (EN 8-grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with 2 Nos. templates/Anchor plate of size 320 mm x 320 mm x 4 mm thick having 4 Nos. 24 mm dia. holes to match with PCD of poles base plate with positioning of foundation bolts and providing 65 mm (OD) 2 Nos. DWC pipe for cable entry and exit and reinstall the pole with the help of hydra/crane. |
| 18 | Fabricating ,Providing and fixing of M.S connector cover on existing 12m high M.S swagged pole with suitable size made out of 1 mm thick M.S sheet with kabja from one side and another side by tight by 2 no.M.S flat clamo(1.6 mm thick) nut boltsi/c painting with approved shade i/c dismantling the existingdamaged/rust connecter cover etc.complete as required. |
| 19 | Supplying and laying of following size of XLPE insulated / PVC sheathed al. Conductor armourd power cable of 1.1 KV grade i/c making, connection testing etc. as reqd. i/c rebate on Existing cable.a).2C x 25sq.mm |
| 20 | Supplying and laying of following size DWC HDPE pipe ISI marked alongwith all accessories like socket,bend,couplers etc conforming to IS 14930 Part II complete with fitting and cutting,jointing etc.direct in ground/RCC (75 cm below ground level in kaccha portion/350 mm below in pucca portionas per site requirement including excavation and refilling the trench but excluding sand cushioning and protective covering etc ,complete as required I/c rebate on existing Pipe. a) 90mm dia(OD-90mm & ID-76mm nominal) |
| 21 | Fabricating , supplying and fixing wire mesh frame work made out of 40*40*6 mm thick angle iron having 40*6 mm flat strip and wire mesh 6 SWG dia M.S wire with 25mm*75mm space in between mesh and top covered for rain protection by 16 SWG MS sheet and making main door gate having suitable locking arrangement with godown lock i/c grouting with cement concrete & primer and spray painting with super synthetic enamel paint of approved color quality with heavy duty godown lock etc.complete as required. |
| 22 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as reuired . a) 2 x 25 s.mm |
| 23 | Supplying and laying 6 SWGG.I wire at 0.5m below the ground level for conductor earth electrode i/c connection ,termination with G.I thimble etc as reqd. |
| 24 | Supplying, installation, testing and commissioning of following accessories inside the in built control box on existing street light pole (a). 6mm thick phenolic laminated/Bakelite sheet inside the window mounted on the existing mounting strips inside the flush door.(b). 1 no. 63 Amp terminal block suitable forfollowing conductor / cable, fixedonDIN channels i/c providing and fixing DIN channel of suitable length – on the existing phenolic laminated / Bakelite sheet.(i) 25 sq mm conductor – 2 nos. (incoming and outgoing looping) (ii) Terminal suitable for 6 SWG GI wire / 2.5 sq mm wire.(c).6 Amp,SP MCB,10 KA, ‘C’ Series – 1 no. including mountings on DIN channel, Earth stud 2 Nos. welded at suitable height i/c washers, springs washers & nuts etc.(d) Suitable arrangement for saddling of incoming / outgoing cables. |