| 1 | SCHEDULE OF WORKS AND BoQ |
| 2 | Civil and allied works |
| 3 | Scrapping the existing painted surface with wire brush/putty blades/sand paper etc and removing the old paint neatly as per the directions of the Engineer-in-charge. |
| 4 | Painting with wood primer/metal primer/cement primer/oil based primer of approved quality one coat in all floorsand levels after preparing the surface for painting including scrapping, cleaning etc. complete.Asian/ Berger/Nerolac. |
| 5 | Finishing the wall surfaces with acrylic putty to get a required finish as per the directions of the Engineer-in-charge.Brand: Asian/Berger/Nerolac. |
| 6 | Painting with acrylic emulsion paint(interior quality)of approved brand(Roller finish) on old/new surface of walls,shades,ceiling etc after scrapping and cleaning the surface. Brand:Asian/Berger/Dulux/ Nerolac.2 or more coat |
| 7 | Labour Charges for Dismantling of Aluminium partitions,doors etc with laminated board/glass in all floors without damage and stacking as per directions of the Engineer-in-charge. |
| 8 | Labour charges for fabrication and fixing of aluminium partition,door,windows with Department supplied materials like Aluminium frames,laminated board,glass etc with necessary modification and alteration as per drawing and directions of the Engineer-in-charge including the cost of screws,cleat rubber,beadingetccomplete. |
| 9 | Providing and fixing frameless Patch fitted glass door with 12mm thick clear float toughened glass of size (2.4 x 0.9/1.0/1.2) m with double acting floor springs and related patch fittings of Dorma/Geze or approved equivalent make including all necessary hardware and accessories such as 450 mm SS H-handles, Mortise lock with one side knob and other side key, pivot etc. Make: Geze or equivalent. |
| 10 | Providing and fixing suspended Seamless Gypboard false ceiling in all shapes and design, which includes providing and fixing GI perimeter channels of size 0.55 mm thk having one flange of 20 mm and another flange of 30 mm and a web of 27 mm along with a perimeter of ceiling, screw fixed to brick/partition with the help of nylon sleeves and screws, at 610 mm centers. Then suspending GI intermediate channels of size 45 mm, 0.9 mm thk with two flanges of 15 mm each from the soffit at 1220 with ceiling angle of width 25 mm x 10 mm x 0.55 mm thk fixed to soffit with GI cleat and steel expansion fasteners. Ceiling section of 0.55 mm thickness having knurled web of 501.5 mm and 2 flanges of 26 mm each with lips of 10.5 mm are then fixed to the intermediate channels with the help of connecting clips and in direction perpendicular to the intermediate channel at 457 mm centres 12.5 mm tapered edge gypboard (conforming to IS: 20951982) is then screw fixed to ceiling section with 25 mm dry wall screws at 230 mm centers. Rate to be inclusive of cutting and making good the ceiling for AC ducts, grills, diffusers, lights, trapdoors etc; fixing of any additional ply or padding as support for light fixtures, AC fixturees etc complete the work with any stepping if required as per design. Make: USG Boaral or equivalent. |
| 11 | Providing and fixing clear toughened float glass of 12mm thick, which will be held within the embedded Slim anodised aluminium channels at top and bottom fixed to the floor and ceiling with appropriate type Hilti/Fischer make ss fastener.The glass to glass joints will be sealed with approved transparent weather sealant. All glass edges shall be of polished finish.The work includes necessary M.Steel P.U painted sub-structure above false ceiling which is anchored to roof slab to support the glazing system. Make: Geze & Saint Gobain. |
| 12 | Supplying and fixing Sun control film 25 Micron thick(Garware) of approved colourfor glazing panels of windows,ventilators, partitions and doors etc in all floors. |
| 13 | Supplyand fixing Etch film(Garware or equivalent)of approved strip Patternfor glazing panels ofAluminium partitions,doors,windowsetc. |
| 14 | Dismantling existing brick/mortar base and making good the floor surface to receive new floor finish, disposing of unserviceable materials from the campus as directed by the engineer-in-charge.(Chipping 2 window sill mortar to a maximum of 6cm dpth for 2m length each). |
| 15 | Providing and fixing 18 mm thick gang saw cut granite slab, mirror polishedof required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4, joints treated with white cement, mixed with matching pigment, epoxy touch-ups, including rubbing, curing, moulding and polishing edges to high gloss finish etc; at all heights. Basic rate of granite is Rs.220/Sqft. |
| 16 | Supply and fixing 12mm thick charcoal panels for wall and columns using 9mm thick marine ply framing with necessary fittings etc complete the work as per the approved design and direction of the Engineer-in-charge. Make: Charcoal - TREND, Delica or approved equivalent ;Marineply - Century, Greenply, Kitply. |
| 17 | Under-counter sliding storage using 19mm marineply laminated with 1mm laminate on both sides to be provided below table top made with 25mm laminated marineply including providing and fixing 5mm toughened clear glass for sliding door panels inclusive of fixing 6mm multiwood boards on bottom,2 sides and back wall areas before panelling the storage boards.The rate to be quoted for 25mm table top,vertical/sides,bottom with 2 side lamiantes and inclusive of necessary SS locking system with keys,hinges,handles etc complete as per the approved design and instructions of the Engineer-in-charge. Marineply-Century,Greenply,Kitply Laminate: Century, Greenlam,Kitply.(Table top/storage size 2.45x0.50 m). |
| 18 | Overhead storage using 19mm marineply on top/sides/door shutters and bottom laminated with 1mm laminate on both sides including9mm multiwood extra board on back wall with necessary steel fittings like autocloser,lock,key,handles,hinges etc complete as per the approved design and instructions of the Engineer-in-charge.(Storage size 2.25x0.50 m). |
| 19 | Custom-built table of various size and shapes made of 25mm thick marine ply laminated with 1.1mm thick laminate of approved design and shade with matching 2mm thick PVC edge banding on the exposed sides and other sides with 0.8mm thick PVC edging and shall be supported by modesty panels with 19mm laminated marine ply using metallic brackets, provided with GI cable managers and cable trays to pass wires, etc. as per drawings/instructions of the Engineer-in-charge. Make: Marineply-Century,Greenply,Kitply Laminate: Century, Greenlam,Kitply |
| 20 | Supply and installation of custom-built storage as per the approved design/drawings and instructions following the technical specifications.Metal Pedestal trolley storage on castor wheels with 2 equal size drawers and 1file drawer with an overall dimension of 400x680x520mm (W,H,D) matching with the existing table size, made of 0.8mm thick MS CRCA sheet in powder coated finish. Top and front panels are to be provided with pre laminated particle board/MDF in approved design & shade with matching edge banding of 1.6mm thick including lock & key,telescopic slides,brush finish SS recessed handles etc. complete. |
| 21 | BILL OF QUANTITIES FOR ELECTRICAL WORKS |
| 22 | Supplying and fixing modular blanking plate (1M) on the existing modular plate & switch box excluding modular plate as required. Make: Crabtree/Schneider/ Havells. |
| 23 | Supply andlaying of 20mm Electrical flexible PVC conduits for light/fan wiring.MAKE: Balco/Toms/Precision. |
| 24 | Supply andlaying of Electrical rigid PVC conduits and Suitable type accessaries like bend,coupling, \"T\" joints etc. of ISI grade, Medium duty for laying through roof/surface/Floor/brick wall or hollow block wall,including concealed work. MAKE: Balco/Toms/Precision. |
| 25 | 20 mm |
| 26 | 25 mm |
| 27 | Supply and fixing of following modular switch/socketon plateconnectionsrequired.Make: Crabtree/Schneider/Havells. |
| 28 | 10AModular One Way switch |
| 29 | 10AModular Two way switch |
| 30 | 16A Modular One way switch |
| 31 | 25A Modular DP switch |
| 32 | 6/16A Plug socket outlet - 2 Module |
| 33 | 2 module fan regulator |
| 34 | Supply and fixing of following modular metal boxes on brick wall/on table including concealed work.Make: Crabtree/Schneider/Havells |
| 35 | 12M metal box |
| 36 | 8M metal box |
| 37 | 6M metal box |
| 38 | 2M metal box |
| 39 | Supply and fixing of following modular plates on metal boxes.Make: Crabtree/Schneider/Havells |
| 40 | 12 M plate |
| 41 | 8 M plate |
| 42 | 6M Plate |
| 43 | 2M plate |
| 44 | Supply & laying of following Wiring for power circuit, UPS circuits/sub main circuits etc using copper wire along with earth copper wire in the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/concealed through PVC conduit and all accessories as required.Make: V-Guard/RR/Finolex. |
| 45 | 2 x 1.5 sq. mm +1.5 sq. mm earth wire |
| 46 | 2 x2.5 sq. mm +2.5 sq. mm earth wire |
| 47 | 2 x 4 sqmm +4 sqmm earth wire |
| 48 | Supply,installation,Testing and Commissioning of recessed ceiling mount 18/20 W LED Ultra Slimmest Panel Light with integral driver for office purpose withcool dayColour Temperature(6000-6500 K).Make: Philips/Havells/Crompton.(Shape of the light should be as the decision of Engineer in charge) |
| 49 | Supply,installation,Testing and Commissioning of recessed ceiling mount 5 W (warm white) LED Ultra Slimest Panel Light.Make:Philips/Havells/Crompton. (Shape of the light should be as the decision of Engineer in charge) |
| 50 | Supply,installation,testing and commissioning of 1200 mm BLDC ceiling fan with remote controller.Make: Atomberg/Crompton/Orient |
| 51 | Networking related works |
| 52 | Supply of DATA & VOICE accessories |
| 53 | Dual Face Plate (3x3) |
| 54 | 3x3 metal box |
| 55 | Cat6 Keystone |
| 56 | 25 mm PVC conduit with all accessories including coupler, bend, flexible pipes, etc. - ISI Marked |
| 57 | CAT 6 UTP cable |
| 58 | Installation & Documentation Charges for Data & Voice |
| 59 | Laying CAT 6 able along with required PVCPipe under floor trenches and wallonexistingfloor.Conduits and HDPE pipe shallbelaidbelowthe flooringfinished levels as per the site conditions or throughpartitionswithallaccessories.Therateshall includecutting/chippingfloortotherequiredsizes on existing floor for laying conduits for data, telephonecablesetc.Therateshallincludethecostof conduitsandaccessories.Therateshallalsoincludethe activity of clearing the debris generated from the preparation of trenches. |
| 60 | Rerouting and fixing exiting voice connection. |
| 61 | Dual/single faceplate fixing along with Key stone voice and Data Termination & labeling with laser print Label (on Patch Panel). |
| 62 | Fixing 3x3 metal box withaccessories. |