| 1 | Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified. |
| 2 | Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) un-reinforced, complete all as specified. |
| 3 | Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 4 | Taking down cement plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified. |
| 5 | Material and Labour for Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified. |
| 6 | Supply and fixing in repair 20mm outer dia stainless steel decorative curtain rod of thickness 20 guage with stainless steel brackets near to ends with stainless steel finials with adopter for 20mm dia curtain rod at both ends, complete all as specified. |
| 7 | Material and Labour for Vitrified light shade Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6) jointed in neat cement slurry and pointed in coloured cement,complete all as specified and directed. |
| 8 | Material and Labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement, complete allas specified and directed. |
| 9 | Material and labour for Rendering 10mm thick cement plaster on other than fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and as directed. |
| 10 | Material and Labour for preparing new surfaces (plastered or unplastered) of walls and applying two coats of cement base paint over a coat of primer on surfaces of walls, complete all as specified and as directed. |
| 11 | Material and labour for preparing new surfaces (plastered or unplastered) of walls and applying two coat of oil bound distemper white or tinted over a coat of chalk whitening, complete all as specified and directed. |
| 12 | Material and labour for 75 mm thick plain cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate as in plinth protection and laid in panels complete and finished the even & fair and providings joints through out the thickness of plinth protection filed with mastic filling comprising one part of 01 bitumen 85/25 grade and three part of sand by weight all as specified and directed. |
| 13 | Material and labour for preparation of old painted surface ofsteeland iron surfacesof any description, over 10cm width or girth and applying one coats of synthetic enamel paint, complete all as specified. |
| 14 | Material and labour for preparation of old painted surface ofsteeland iron surfacesof any description, over 10cm width or girth and applying one coats of synthetic enamel paint, complete all as specified. |
| 15 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering or in ridges, hips, valley gutter and similar work, complete all as specified. |
| 16 | Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified. |
| 17 | Material and labour for rolled mild steel work in roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-290(Gde E-165), complete all as specified & directed. |
| 18 | Supply and fixing of Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of ancolour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified. |
| 19 | Supply and fixing of Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified. |
| 20 | Dismantling of wall and ceiling boards (fibre, pulb, insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets, complete all as specified and directed. |
| 21 | Supply and fixing of 4 mm thick non asbestos fiber cement plain building boards in false ceiling on and incl aluminium snap grid work 605 x 605 mm withusing 36.5mm x 23.5 mm x 1.5 mm thick main tee, 23.5 x 23.5mm x 1.28 mm cross tee and 25x25x1.5mm angles fixed to perimeter of wall including necessary supporting hanger with 4 mm dia GI wire and J bolts washer nuts for securing frame work to ceiling suspended @ 120 cm c/c both ways, complete all as specified and directed. |
| 22 | Supply and fixing of PVC wall panelling made up of PVC hollow panels 25/30cm in width and 10mm thickness interlocking pattern of approved shade and design fixed to wall or ceiling all as specified and directed. |
| 23 | Supply and fixing of 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and as directed. |
| 24 | Taking down shutters of any description exc. 1 sqm and not exc. 2 Sqm each, complete all as specified. |
| 25 | Taking down shutters of any description exc. 1 sqm and not exc. 2 Sqm each and refixing in same or other opening after easing and adjusting shutters, complete all as specified. |
| 26 | Supply and fixing of powder coating of any colour (thickness or powder coating not less than 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified complete all as specified and directed. |
| 27 | Supply and fixing of powder coating of any colour (thickness or powder coating not less than 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. |
| 28 | Supply and fixing of powder coating of any colour (thickness or powder coating not less than 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified, complete all as specified. |
| 29 | Supply and fixing of 4.8mm thick sheet glass, ordinary quality & glazing with oil putty around the glass in square n exc 0.5 sq.m in each pane, complete all as specified and as directed. |
| 30 | Supply and fixing of 6mm thick toughhned glass, glazing with oil putty around the glass in square exc 0.5 sq.m in each pane, complete all as specified and as directed. |
| 31 | Supply only Door closure hydraulically regulated designation No. 1 universal type of aluminium (die cast) body, suitable for door shutters of 750mm in width and of weight between 35 Kilogam, complete all as specified and as directed. |
| 32 | Supply only Aluminium mortice lock, 4 lever, vertical type, size 100 mm, complete in all respect as specified. |
| 33 | Supply and fixing of Plain framed factorymade 35mm thick shutter of 2nd class hard wood rail & style (two panel) with lock rail and panel of 9mmBWP commercial plywood or 12 mm veneered particle board with commercial veneering on both faces , the size of rail and style as per IS 1003 (Part-1) kiln seasoned and pressure treated, fitted to chowkats, complete all as specified. |
| 34 | Material and labour for Precast interlocking paver blocks factory made confirming to IS-15658-2006 of60mm thick grade of concrete M-35 with cement and coloured pigment (topping thickness not less than 5mm thick with white cement and colour pigment non fadable with epoxy coating) including 50mm thick sand cushioning under floors or in foundations including watering and consolidation, complete all as specified & directed. |
| 35 | Material and labour for PCC 1:3:6 (nominal mix), type C-2 using 40mm graded stone aggregate as in foundations, filling, mass concrete and sub base of floor, complete all as specified & directed. |
| 36 | Material and labour for PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified. |
| 37 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etcomplete all as specified and directed. |
| 38 | Material and labour for Point wiring using FRLSH PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through and including 20/30mm size PVC casing and caping of appropriate size not less than 20 mm dia and 1.5 mm thick including all fittings viz tees, bend, junction box and modular metal flush sunken box 1.2 mm thick with suitable support frame and cover plate (inner/outer) of required modules for mounting switches, sockets, fan regulators, connecting earth for light/fan/bell point including cutting chases in walls and making good to disturbed surface complete all as specified and directed .(Note : Switch/bell push/fan regulatorshall be measured and paid separately) |
| 39 | All as per the description of Serial Item No 38 here-in-before but for one 3 pin socket outlet 5 Amp on same board, complete all as specified and as directed. |
| 40 | All as per the description of Serial Item No 38 here-in-before but for one 3 pin socket outlet 5 Amp on independent board, complete all as specified and as directed. |
| 41 | All as per the description of Serial Item No 38 here-in-before but for one 3 pin socket outlet 15 Amp independent board using cable of size 4.00 Sqm with 2.5 Sqmm copper conductor in green colour for as earth continuity conductor all as specified and directed. |
| 42 | Supply and fixing of modular switch one way 10 Amp, 1 module, complete all as specified and directed. |
| 43 | Supply and fixing of modular socket 10 Amp, 2/3 pin mutipurpose, 2 module,complete all as specified and directed. |
| 44 | Supply and fixing of modular switch piano one way, 16 Amp, 1 module,complete all as specified and directed. |
| 45 | Supply and fixing of modular socket 6/16 Amp, 2/3 Pin multipurpose, 2 module, complete all as specified and directed. |
| 46 | Supply and fixing of 20W surface/wall mounted box type batten LED luminaire, extruded polycarbonate housing with PC diffuser and integrated electronic driver with high efficiency long life, CRI=80(Minimum), PF>0.90, luminous efficacy > 120 lumens/Watt operating voltage 140V-240V, colour temperature (CCT) > 5700 + 300K, THD < 10% complete with all accessories internally prewired and including connection up with flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and as directed. |
| 47 | Supply and fixing of slim LED Panel light round, compact, aluminium die cast edge lit panel, Recess mounted round fixture with opal diffuser and separate electronic driver round shape 15 watt, 3000K, in warm white colour and all as specified and directed. |
| 48 | Supply and fixing Ceiling rose, 3 phase/PVC/Polycarbonate, isolated body and all as specified and directed by Engr-in-Charge. |
| 49 | Supply and fixing in replacement SPN MCB DB 8 - way, doubledoor, 240 volts for Sheet Steel, Phosphatised, Powder Painted MCB DBs with Bus Bar,Neutral Link, Earth Bar and Din Rail (In accordance with IS 13032, IS 8623, IEC/BSEN 60439-3), complete all specified and directed by Engr-in-Charge. |
| 50 | Supply and fixing in replacement MCB SP 6-32 Amps \"C\" series 240V 50Hz 10 KA suitable for lighting and other domestic loads complete all as specified and directed by Engr-in-Charge. |
| 51 | Supply and fixing in replacement MCB SPN 40 to 63 Amps \"C\" series 240V 50Hz 10 KA suitable for lighting and other domestic loads complete all as specified and directed by Engr-in-Charge. |
| 52 | Supply and fixing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminiuum stranded conductor served with an inner sheating of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm suspention wire one twin core 16 sqmm solid conductor all as specified and directed. |