| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required GROUP-B |
| 2 | Supplying and drawing following sizes of FRLS PVC insulated copper condutor, single core cable in the existing surface/ recessed steel/ PVC Conduit as required. I0 3 x 1.5 sqmm |
| 3 | Supplying and drawing following sizes of FRLS PVC insulated copper condutor, single core cable in the existing surface/ recessed steel/ PVC Conduit as required. ii) 3 x 2.5 sqmm |
| 4 | Supplying and drawing following sizes of FRLS PVC insulated copper condutor, single core cable in the existing surface/ recessed steel/ PVC Conduit as required. iii) 3 x 4.0 sqmm |
| 5 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i) 20 mm |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required |
| 7 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) i) 4 way (4 + 12), Double door |
| 8 | Supplying and fixing 5 A to 32 A rating 240/415 volts,\"C\" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. i) Single pole |
| 9 | Supplying and fixing 63 A rating 240/415 volts,\"C\" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. i) Four Pole |
| 10 | Providing and fixing of maintenance free, dust and moisture free,Engineering plastic injection moding Cooler Body, Cooling pad- 4D honey combo cellulose wet pad with anti bacterial resins fibre body ducting air cooler of following specification : Air flow 18000 CMH, Cooling area 2500 sqft (without ducting), Motor-Inverter high torque motor 380 to 415 volt/50 Hz, 1.1 Kw ( Single phase turbo axial fan) with 1400 RPM, , Air pressure - 180 P.A., Water tank capacity - 35 Ltr, Air outlet size - 670 mm x 670 mm,etc as per direction of engineer in charge. Make - Sky air cooler model URANUS or equivalent make and model in Symphony, Maharaja, Cool wind complete as per requirement or as decided by Engg-In-Charge. |
| 11 | Providing and fixing of angle iron frame of suitable size for placing of duct cooler made out of 50 mm x 50 mm x 5 mm thick angle iron including making of stand as per site requirement and installation of duct cooler, as per direction of Engg- in -Charge, |
| 12 | Suppling , Installationand making of duct made of 24 Gauge GSS sheet of suitable size as per site requirement andducting will be insulated with high quality insulating material etc as required as per direction of Engineer- in- Charge at site. |
| 13 | Supplying and fixing of the heavy duty air controlling louvers/ shutters with manually operated adjustable blades complete with matelic frame as per site requirement. |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 15 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(i) 20 mm nominal dia Pipes |
| 16 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per direction of Engineer in Charge. |
| 17 | Supplying,Installation, testing and commissioning of heavy duty exhaust fan, metalic body 230V, 300 mmsweep,single phase including making the hole to suit the size of the above fan, making good the damage i/c P/F louver and shutter complete with frame for exhaust fan of size connections,testing and commissioning etc as required. |
| 18 | Supplying and fixing of 250 mm sweep, 1250-1300 RPM non metallic exhaust fan suitable for single phase, 50 Hz, 230 volt AC supply in existing opening including connection etc as required. |
| 19 | Supply, installation, testing and commissioning of 10 watt LED tube fittings comprises of extruded channel in thermally conductive material ,high translucent serrated milky white diffusers used to get glare free and smooth light distribution, efficiency :100lm/w and LED tube directly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. |
| 20 | Supply, installation, testing and commissioning of 70 watt LED flood light fittings made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. System efficacy >110/120 LPW directly on existing pole/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. |