| 1 | Supply Installation testing and commissioning of retrofit emission control device for 12.5 kVA desiel generator of any make/vintage CategoryApplication :- Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel EngineTechnology/Type :- ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides CatalystGuaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min)Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) 70% for all DG sets |
| 2 | TEST REPORTSCertification :- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as given below:(a)Automotive Research Association of India (ARAI, Pune)(b)International Centre for Automotive Testing (ICAT, Manesar)(c)Indian Institute of Petroleum (IIP, Dehradun)(d) Vehicle Research Development Establishment (VRDE, Ahmednagar)Back Pressure due to the Emission Control retrofit device :- Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM(as per the capacity of the DG set) Note: The Contractor will submit Design, drawing and Make of RECD for approval of Accepting officer for his approval before executing the work at site. |
| 3 | Supply Installation testing and commissioning of retrofit emission control device for 30 kVA desiel generator of any make/vintage.CategoryApplication :- Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel EngineTechnology/Type :- ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides CatalystGuaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency(Min)Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency(Min) 70% for all DG sets |
| 4 | TEST REPORTSCertification :- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as given below: (a)Automotive Research Association of India (ARAI, Pune)(b)International Centre for Automotive Testing (ICAT, Manesar)(c)Indian Institute of Petroleum (IIP, Dehradun)(d) Vehicle Research Development Establishment (VRDE, Ahmednagar)Back Pressure due to the Emission Control retrofitdevice :- Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM(as per the capacity of the DG set).Note: The Contractor will submit Design, drawing and Make of RECD for approval of Accepting officer for his approval before executing the work at site. |
| 5 | Supply Installation testing and commissioning Of retrofit emission control device for 35 kVA desiel generator of any make/vintageCategoryApplication :- Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel EngineTechnology/Type :- ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides CatalystGuaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency(Min)Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency(Min) 70% for all DG sets |
| 6 | TEST REPORTSCertification :- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as given below: (a)Automotive Research Association of India (ARAI, Pune)(b)International Centre for Automotive Testing (ICAT, Manesar)(c)Indian Institute of Petroleum (IIP, Dehradun)(d) Vehicle Research Development Establishment (VRDE, Ahmednagar):Back Pressure due to the Emission Control retrofitdevice :- Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM(as per the capacity of the DG set)Note: The Contractor will submit Design, drawing and Make of RECD for approval of Accepting officer for his approval before executing the work at site. |
| 7 | S&F in repair of sign Board of size 5100mmx 1200mm made out of 2 mm thick Stainless Steel sheet and including marking of outer border in numerical and figure height 100 mm upto 20 Nos as per approved pattern including 02 nos of 50 mm SS pipe stand complete all as specified and as directed. |
| 8 | S&F in repair of Sign Board of size 1200mmx900 mm made out of 2 mm thick Stainless Steel sheet and including marking of outer border in numerical and figure height 100 mm upto 20 Nos as per approved pattern including 02 nos of 50mm SS pipe stand complete all as specified and as directed. |
| 9 | M&L for spreading pea gravel of size 40 mm graded up 300mm height at substation areacomplete all as specified & as direted. |
| 10 | M& L for fabrication ofMS sheet cover of 18 gauge of suitable size for covering of duct for electric cables at substations including taking down old sheet cover complete all as specified & as directed. |
| 11 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing/connecting as required 25x4 mm galvanised iron strip including taking down old conductor complete all as specified and as directed. |
| 12 | Surface dressing of uneven surfaces of natural ground, rough excavated surfaces not exceeding 15 cm deep and filled area where ordered shall be trimmed to an even surface horizontal or slopping, by removing vegetation and by scrapping high patches and filling low patches with the scrapping soil to given an even and neat look to the site. complete all as specified and as directed. |
| 13 | S&F of MS posts and struts as in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.;flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 as indicated or directed and inclusive of one primer coat, and 2 coat of sythentic enamel paint complete all as specified and as directed. |
| 14 | Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified & as directed. |
| 15 | S&F 4 mm thick mild steel wire 150×100 mm mesh up into mattresses or cages, lapped wired and fixed in position including welded for fencing to grid including one coat of primer and two coat ot synthetic enamel paint complete all as specified and as directed. |
| 16 | Excavation, in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth for laying cable in any type ofsoil and getting out complete all as specified & as directed. |
| 17 | M & L for Sand cushioning to under ground cable with dry sand locally available 8cm thick before laying the cable and 15 cm above the cable, stretching and testing of cable complete all as specified & as directed. |
| 18 | S&F reinforced precast concrete cable cover classLV, Type 1, flat, size 300mmx 180mm x 40mmfor mechanical protection of cable with width equal to lenght of brick including taking down old cover complete all as specified & as directed. |
| 19 | Excavating in trenches, n exc 1.5 m deep and getting out in Soft/loose soil complete all as specified and directed. |
| 20 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm Soft soil/loose soil complete all as specified and directed. |
| 21 | Removing excavated material upto a distance of 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 22 | M&L for Plain cement concrete as in foundations, filling and mass concrete Type D2 1:4:8 (40 mm graded crushed stone aggregates) complete all as specified and as directed. |
| 23 | M&L for approved earth filling under floor, spreading in layers not exceeding 30 cm thick, watering, ramming/ rolling and finishing to required size, shape, etc., not exceeding 1.5m high from base complete all as specified and as directed. |
| 24 | M&L for brick work with sub-class \"B\" bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 complete all as specified and as directed |
| 25 | M&L for Rendering 15mm thick cement mortar (1:4) on fair faces of brickwork or concrete surfaces as inexternal plaster complete all as specified and as directed. |
| 26 | M&L for 2 coats of white washing including preparation of surfaces of walls complete all as specified and as directed. |
| 27 | M&L for plain cement concrete 100 mm thick type C-2, 1:3:6 (40mm graded crushed stone aggregate) as in sub-base of floor complete all as specified and as directed. |
| 28 | M&L for plain cement concrete 100 mm thick type B-2, 1:2:4 (40mm graded crushed stone aggregate) as in sub-base of floor complete all as specified and directed. |
| 29 | Demolition of brickwork or stone/ boulder masonry, built in cement or cement lime mortar includingall quoins, arches, pillars, etc, but excluding ashlarfacings, dressed stonework and precast concrete articlescomplete all specified and as directed. |
| 30 | Demolition of cement concrete (unreinforced) in any description and in any position not otherwise specially provided for complete all as specified and as directed. |
| 31 | Dismantling of wrought iron or mild steel work of any description complete all as specified & as directed. |
| 32 | Notes :- (i)The contract sum shall be after deducting the amount of Credit shown in Sch of Credit of this Tender.(ii) If anyitemofsame descriptionin nature is found to be entered as \"double in BOQ\"and the bidder quotes different rates against same item, then the rate quotedon lower sideshall be applicable and higher rate will not be allowed to be paid in any circumstances.No claims on this account shall beentertained on a later date. |