| 1 | S&F CRCA sheet metal enclosure with metal clad plug and socket single phase with five pin and earth plugh & socket suitable for surface / flush mounting 240 V, 20 Amps capacity controlled by and including one 20 Amps MCB SP, 10 KA capacity, completed all as specified and directed. |
| 2 | M&L Sub main wiring with 4 sqmm (Nominal area) with two runs of single core, PVC insulated, multistranded, unsheathed, copper conductor cables 1100 V grade drawn through PVC conduit in concealed wiring including 4.0 Sqmm (nominal area) single core PVC insulated, multistranded, unsheathed, copper cnductor as earth wire and duly connected to earth point completed all as specified and directed.Note : Cutting chases, making good disturded surface shall be included in the same item. |
| 3 | Supply, install, test and commissioning split type air conditioning unit (inverter type) complete with driver motor air cooled condenser with all assessories varied speed and dual rotary compressor including fixing the out door units as per manufacture recomendation and fixing of room (high wall) unit on wall provoding and making interconnection including refregrat piping with nitryle rubber insulation and control cable from indoor to outdoorup to a distance of 3 meter power cabling (max 3 meter from isolator / encloser) to unit, first recharging of refrigrant gas incluiding cordless remote, drain pipe of 25mm dia for connecting drain line from indoor unit maximum of 3.0 meter to neareast drain point complete as required capacity of 1.5 TR 5 Star all as specified and directed. Make Carrier / Blue Star / LG / Voltas |
| 4 | Supply, install, test and commissioning split type air conditioning unit (inverter type) complete with driver motor air cooled condenser with all assessories varied speed and dual rotary compressor including fixing the out door units as per manufacture recomendation and fixing of room (high wall) unit on wall provoding and making interconnection including refregrat piping with nitryle rubber insulation and control cable from indoor to outdoorup to a distance of 3 meter power cabling (max 3 meter from isolator / encloser) to unit, first recharging of refrigrant gas incluiding cordless remote, drain pipe of 25mm dia for connecting drain line from indoor unit maximum of 3.0 meter to neareast drain point complete as required capacity of 2 TR 5 Star, complete all as specified and directed. Make Carrier / Blue Star / LG / Voltas |
| 5 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, as in hard dense soil , complete all as specified and directed. |
| 6 | M&L Cement concrete in foundations, filling and mass concrete type B-2 1:2:4 , 40mm graded aggrigate, complete all as specified and directed. |
| 7 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed. |
| 8 | M&L preparation of new steel surfaces andapplyingtwo coats of synthetic enamel paint of any description not other wise described over 10 cm width or grith etc, complete all as specified and directed. |
| 9 | M&L Pre- painted galvalume aluminum zinc coating GI based Corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified,including necessary scaffolding and safety measures at any floor complete all as specified and as directed.(Make: Tata bluescope/Sexena Marine Tech/JSW or equivalent) |
| 10 | All as per item No 09.00 above but inPlain steel sheet for Ridges complete all as specified and as directed. |
| 11 | M&L Brick work with fly ash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 Complete all as specified and as directed. |
| 12 | M&L Half Brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick built in CM 1:4 completeall as specified and as directed |
| 13 | M&L rendering 15 mm thick in cement mortar (1:4) on brick or concrete surfaces , finished even & smooth without using extra cement all as specified and directed. |
| 14 | M&L preparation of new plastered or unplasteredsurfaces of wall and applying two coats of cement base paint complete all as specified and directed. |
| 15 | M&L 100 mm thick PCC Cement concrete type B- 2, 1:2:4 (40mm graded aggregate)as infloor etc, complete all as specified and directed. |
| 16 | M&L 25 mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as infloor, finiushed the surface even and smooth without using extra cemend , complete all as specified and directed. |
| 17 | M&L RCC nominal mix(20mm graded aggregate)for slab supported on walls, beams and columns in floors, roofs, landings balconies canopies, deck slab and in shelves and the like etc etc, complete all as specified and directed. |
| 18 | M&F form work to rough finished surfaces of concrete ofslab supported in wall, chajjas, troughs and similar items including edges, complete all as specified and directed. |
| 19 | M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for colomns hocking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips quality conforming to, complete all as specified and directed. |
| 20 | M&L machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, including15mm thick screed bed or bedding layer for laying floor finishes in CM 1:6, complete all as specified and directed. |
| 21 | M&L advanceencapsulated Maintenance free low carbon high tensile with pure electrolytic copper molecularly bonded Chemical Earthing Rod, dia 17.2mm * 3000mm solid MS Copper bonded rodwhich should be having tensile strength 650 - 700 (N/mm2) & as per UL. The material must be tested from CPRI & as well as from ISO certified LAB as per IEC/EN 62561-2 & Normative reference: (IEC 6957, 60068-2-52). The material must be tested Salt mist test conducted in accordance with IEC 60068-2-52:1996. CB Terminal must be with the Rod for the connection. The annular space between the pipe and strip to be filled up with Compactfill (CF) (Crystalline Conductive) mixture. The job includesexcavation of pit in any type of hard dense soil/ disinterigated rocky strataof size 1000 mm x 1000 mm x 3050 mm depth and taking out all excavated soil, lowering and placing copper electrode in centre of pit andfilling ofback fill compoundhaving excellent moisture retaining capacity in sourrounding of electrode in400 mm dia all around the electrode( Min 5 bags of 25 Kg each ofback fill compound graphite baseper pit per unit to be fill or more quantity of BFC if required to achive less than one ohms). The remaining portion of earth pit to be filled with agriculture soil / black cotton soil free from stones etcto be bring from out side defence land . The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:2:4) typeB1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. NOTE: 1) The quantity of BFC indicated above is generally for normal/good soils.In case the soil resistivity is high , the quantity of BFC should be increased & cost of the same is deemed to be inclusive in the quoted rates. 2). If the desired earth resistance not obtained the earthing shall be re-done by contractor without any extra cost to Govt . 3). Removal of excavated soil and filling of agriculture soil brought from out side defence land shall be included in the overall rate quoted. |
| 22 | S&F ESE LA (Early streamer emission lightning arrester) with 79 meter radius at 5 meter height with level 1 protection level as per NFC 17 192 : 2011through OEM service including antenna base for fixing the mat and 03 no guy wire for supporting of LA complete all as specified and as directed. |
| 23 | S&F electromechanical 6 digit with IP65 protection strike counter for counting the no of strikes arrested by the Lightning Arrester, complete all as specified and directed. |
| 24 | S&F copper strip 20 x 3.15mm with Percelin saddles at a span of 0.5 m and fixing screws etc. for roof conductors and down conductors above ground with connection arrangement to earth termination rod etc, complete all as specified and directed. |
| 25 | S&F test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw fixed in the cover box made up of 3.15 mm Gi sheet with hinged door and locking arrangement duly painted with one coat of silver synthetic enamel paint over two coats of red oxide primer. |
| 26 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed(unit rate shall be inclusive of demolition of cement concrete blocks for embedding hold fasts complete.) |
| 27 | S&F Powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. (minimum thicknessof powder coating 50 micron), complete all as specified and directed. |
| 28 | S&F Powder coated anodised aluminium window shutters, Sliding type with all fittings like lock strike plate rollers, locking devise, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each shutter, anodised aluminum snap beading screws etc. (Thickness of powder coating not less than 50 micrones) Aluminium frame and Channels shall be mesured and paid separatly, complete all as specified and directed. |
| 29 | S&F 5.50mm thick Sheet glass, selected quality plain/coloured and glazing with alum beads in square/ Rectangle for doors windows etc exc 0.5 Sqm each pane complete all as specified and directed. |
| 30 | Taking down cement or cement lime plaster any description, on brick or stone walls including chhajja of any floor and roof projection etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 31 | M&L preparation of new plastered or unplasteredsurfaces of wall and applying two coats of weather coat paint complete all as specified and directed. |
| 32 | M&L preparation of newlyplastered or unplastered surface of walls and applyingtwo coats of oil emulsion distemperany tint complete all as specifed and as directed. |
| 33 | M&L preparation of old decoratedplastered or unplastered surface of walls and applyingtwo coats of oil emulsion distemperany tint complete all as specifed and as directed. |
| 34 | M&L 20mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |