| 1 | Taking down cement plaster any description from roof slab, stone wall, brick wall parapets including raking out joints hacking for key and scrubbing down with water etc (for roof treatment) Complete all as specified and as directed by Engr-in-charge. |
| 2 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finish the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-In-Charge. |
| 3 | Preparing new plastered surfaces and applying Two coats of cement base paint on surfaces of walls over one coat of alkali resistant primer Complete all as specified and as directed by Engr-in-charge. |
| 4 | Dismantling of wall andceiling boards(fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets, any thickness including cover filletsComplete all as specified and as directed by Engr-in-charge. |
| 5 | S&F anodised aluminium snap grid frame work for suspended false ceiling with hangers 6mm dia G.I. (upto 1200mm length) adjusting level, size of grid 605mm X605mm, fixed to steel purlins or rafter Complete all as specified and as directed by Engr-in-charge. |
| 6 | S&F Non asbestos fiber cement building board 6mm thick ,fixed to aluminium or MS galvanised snap grid frame work with screw in ceiling Complete all as specified and as directed by Engr-in-charge. |
| 7 | Demolition ofcement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) complete all as specified and directed by engr in charge. |
| 8 | M&L for 50mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair all as specified. |
| 9 | M & L for machine cut Kota stone slab flooring of size 550mmx550mm and20 to 25 mm thick over and inclScreed bed or bedding layer of cement mortar 1:6, 20 mm thick base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-charge. |
| 10 | Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over Screed bed or bedding layer of cement mortar 1:4, 15 mm thick and jointed withgrey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed |
| 11 | M&L 75 mm thick cement concrete type C1, 1:3:6 (using 20 mm gradedstone aggregate) in plinth protections, finished even and smooth w/o using extra cementincluding necessary joints and filling the joints with bitumastic filling complete all as specified and directed |
| 12 | Dismantling wrought iron or mild steel work of any description not otherwise provided for Complete all as specified and as directed by Engr-in-charge. |
| 13 | S & F Steel work in tubular trusses/purlin including special shapewasher etc. complete using ERW or induction butt weldedtubes conforming to I. S.1161-1979 grade St.-240 Complete all as specified and as directed by Engr-in-charge. |
| 14 | Preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 15 | All as per item 14 above but one coat of synthetic enamel paint on old steel surfaces of any descriptioncomplete all as specified and directed |
| 16 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings Complete all as specified and as directed by Engr-in-charge. |
| 17 | M & L for Prepainted galvanume aluminium zine coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws Complete all as specified and as directed by Engr-in-charge. |
| 18 | M & L for Prepainted galvanume aluminium zine coating GI based plain steel sheeting 0.50 mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws Complete all as specified and as directed by Engr-in-charge. |
| 19 | S&F in repair20 mm dia curtain rods fancy type, mild steel chromium plated with fixing brackets, stops, rollers Complete all as specified and as directed by Engr-in-charge. |
| 20 | Taking down shutters of any descriptionexceeding 1 Sqm but n exc 2 sqmeach complete all as specified and as directed. |
| 21 | Supply and fix 35mm thick 2nd class hard wood factory made plain framed panelled door shutters, (two panel) with lock rail and panel of 12mm veneered particle board with commercial veneered on both faces and rail and stiles as per IS 1003(Pt-I), kilnseasoned and chemically pressure treated etc. complete all as specified and as directed. |
| 22 | Hacking out old broken glass (any thickness, size quality or description) from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads complete all as specified & directed. |
| 23 | S&F plain sheet glass of 3 mm thick in Squares not exceeding 0.50 Sqm in each pane with oil putty and clips complete all as directed by Engineer-in-Charge. |
| 24 | M&L for prepair old decorative surface and applying two coats of oil bound distemper on walls etc Complete all as specified and as directed by Engr-in-charge. |
| 25 | M & L forold decorative surfaces, preparation of wall and applying two coats of cement base paint Complete all as specified and as directed by Engr-in-charge. |
| 26 | Surface excavation n exc. 30 cm deep and averaging 15 cm deep andgetting out hard dense soil complete |
| 27 | M&L for Hard core of gauge n exc 63mm thick of broken boulder spread leveling watering ramming to true surface complete all as specified and directed by Engr-in-Charge.. |
| 28 | M&L for 100mm thick PCC 1:4:8 type D 2 using 40mm graded stone aggregate as in sub base of floor Complete all as specified and directed by Engr in charge. |
| 29 | Sand filling under floors/paver blockincluding watering and consolidation complete all as specified and directed |
| 30 | M&L Colour Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade Complete all as specified and directed by Engr in charge. |
| 31 | S & F Mild steel butt hinges medium weight, cold rolled, 100mm, ISI marked, complete all as specified and as directed by Engr-in-charge. |
| 32 | M&LAluminium anodised, barrel tower bolts of extruded section and fixed of size 200 mm complete all as specified and as directed by Engr-in-charge. |
| 33 | S&F 150 mm long aluminium anodised handles or extruded section complete all as specified and directed. |
| 34 | S&F 300mm long Aluninium alloy, anodised , sliding door bolt with hasp , staple,(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 35 | M & L for Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and directed |
| 36 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point Complete all as specified and directed by Engr in charge. |
| 37 | Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges Complete all as specified and directed by Engr in charge. |
| 38 | Taking down carefully copper/aluminium point wiring from existing points (light, fan, socket or power) alongwith compete fittings such as switches, ceiling rose, pendent holder, sketch fitting & regulator etc. includingmaking good to the disturbed surfaces of wall, roofand floor etc. to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge. |
| 39 | Taking down unserviceable submain wiring and service cablealongwith batten /PVC conduits etc. and making good disturbed surfaces of walls/floors and match the existing surface all as directed at site. |
| 40 | Taking down unserviceable main switches, DBs with MCB SP/Isolators by unscrewing form board complete all as specified and directed by Engineer-in-Charge |
| 41 | M&L for point wiring using approved colour coding as per IS with using approved colour coding as per IS 1.5 Sqmm multistranded,1100 volt grade copper conductor cable of PVC insulated and unsheathed type alongwith 1.5 Sqmm PVC insulatedstranded copper conductor cable for continuous earthing in & incl PVC Casing capeing & condut as per site reqdwith accessories having ISI mark fixed on wall surfaces / ceilingincluding provision PCV Box on top for fixing switches sockets etc. all as specified for one light point/ fan /Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 42 | All as per Srl item No 41 here-in-before but controlled with one 5 pin socket outlet 5 Amp on same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 43 | All as per Srl item No 41 here-in-before but controlled with one 3 pin socket outlet 15 Amp, independent board withcable 2.5 sqmm including provision of 2.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 44 | Supply and fixing ofswitch piano type 15 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge. |
| 45 | Supply and fixing of socket outlet 5 pin 15 Amp 2-in-one230 Volt flush typecomplete all as specified and directed by Engineer -in-Charge. |
| 46 | Supply and fixing of socket outlet 3 pin 5 Amp 2-in-one230 Volt flush typecomplete all as specified and directed by Engineer -in-Charge. |
| 47 | Supply and fixing ofswitch piano type 5 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 48 | M&L Ceiling rose, 3 terminal with ISI markall as specified and directed by Engr-In-Charge. |
| 49 | Supply andfixing surface & wall mounted LED 20W tube light fitting 4 feet with high quality material and design, extruded aluminium housing enhances safety. High quality PC diffuser, reliable and robust housing structure, maximize the endurance over the life time slim integrated design, easy to install efficacy 125 limen/ watt all accessories as specified and directed by Engr-in-Charge. |
| 50 | Material and labour forlamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings. |
| 51 | Supply andfixingLED lamp 12 W energy saving upto 80%, BEE ratedwith all accessories all as specified and directed by Engr-in-Charge. |
| 52 | S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc.all as specified and directed by Engr-in-Charge. |
| 53 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-charge. |
| 54 | Supply & Fixing bulk head light with 10 W LED Lamp complete all as specified and directed by Engr-in-charge |
| 55 | S&F for Steel body exhaust AC, Single Phase 380 mm sweep 1400 RPM,with louvre complete all as per specified and directed by Engineer-in-Charge. |
| 56 | Supply and fixing ofsheet metal enclosure double door for DBs single pole and neutral for 8 way 240 volt complete all as specified and directed by Engineer-in-Charge. |
| 57 | S&F MCBSPN 40 Amp,10 KA all as specified and directed by Engineer-in-Charge |
| 58 | S&F MCB SP 16 Amp, 10 KA. all as specified and directed by Engineer-in-Charge. |
| 59 | Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel wire mesh and medium grade GI earth strip protection pipe 40mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completioncomplete all as specified and directed by Engr-in-charge. Note : The units rate includes the cost of excavation & earth work in any type of soil charcoal & salt in altemate layers, 20mm GI Pipe (light grade) for watering 40mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made. |
| 60 | Supply and laying or fixing or passing through pipe, 1100voltsgrade heavy dutycablewith PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tapeandoverall PVC sheathed 10sq.mm nominal cross section in service connections , complete all as per specified and directed by Engineer-in-Charge. |
| 61 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil for laying/jointing kit/repair of cable and erection of poles complete all as specified and directed |
| 62 | Returning filling in including spreading, leveling watering and well ramming in layers n.exc 25 cm in hard/dense soil all as specified and directed |
| 63 | M&L for taking out old unserviceable and supply, laying, fixing Double walled corrugated HDPE duct pipe of 25 mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as directed. |
| 64 | Schedule of Credit |