Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation in foundation trenches ordrainsincludingdressing ofsidesand ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refillingofjhiriwithwatering&rammingand disposalofsurplusexcavatedsoilasdirected withina leadof50 meter. All kindsofsoil.(B-1/1.8) |
| 2 | Filling available excavated earth (excluding rock) intrenches, plinthsideof foundationetc.in layersnotexceeding20cm.indepth, consolidatingeachdepositedlayerbyramming andwatering includingleadupto 50meter andwith all lift. (B/1.25) |
| 3 | Anti termite treatment of floor using Imidacloprid30.5%ECnonrepellent,odorless, lowdose,environmentallysafeterniticidewith rapidactionnoncorrosive stainfree,by drilling 12mm diameter holes 300mm apart injecting the emulsion as per specification andplugging with cement mortar 1:2 ( 1 cement : 2 coarse sand) in thewholefloorareaDPE12mmdiatermitube systemwithrequirednumberofjunctionboxes aretobeinstalled.Thetermitubewillrunall along the perimeter wall both inside and outside. In the middle area the termitube to be installed at anintervalof1.00Mtr.orlessbothwaysas required with sufficient number of junction boxestopumptheemulsion.Aftersuccessful testing oftermitube,pesticide emulsion of imidacloprid 30.5% EC mixed with water in the rationof1:474willbepumpedbyamotorized spraypumpfromthejunctionboxinspecified manner.Theplinthareaofthe areatreatedwillbe measured for payment. (B-1.39) |
| 4 | Providingandlayinginpositioncementconcrete includingcuringcompactionetc.ofspecifiedgrade excluding the cost of centering and shuttering ;All up to plinth level; 1:4:8 (1-Cement:4-coarse sand:8- graded stone aggregate 40 mm nominal size).(B - 74/3.1.6) |
| 5 | RandomRubblestonemasonryforfoundationand plinthinCementSandMortarabove30Cm.thick wallin:CementMortar1:6(1-Cement:6-Sand)for above30 cm. Thick walls.(B-95/6.1.6) |
| 6 | AddextraforRandomRubblestonemasonry withhardstoneinWallupto30cm.andless thickness. B-6(6.3/6.3.4) |
| 7 | BrickworkwithF.P.S.bricksofclass designation 75 in superstructureaboveplinth level upto floor V level in all shapes and sizes in: Cement mortar 1 : 6 (1 cement : 6 coarse sand)(B/5.2.2) |
| 8 | AddextraforSquareorRectangularPillarsin Superstructre brick work up to five storey.Upto 90 cm length and all sides are free B-5(5.3/5.3.3) |
| 9 | HalfbrickmasonryinSuperstructure,above plinthleveluptofloorV level usingbricksof designation 75 Cement mortar 1 : 6 (1 cement : 6 coarse sand) Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry . (B/5.8.3+5.9) |
| 10 | CenteringandShutteringwithplywoodorsteel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc.(B/4.9) |
| 11 | Centering&shutteringwithplywoodorsteel sheets including strutting, propping bracing both ways with steel propsand removal of formwork foruptofloorfivelevelfor:Suspendedfloors, roofs, landings, staircases, balconies, girders, cantilevers,bands, copingbedplates,anchor blocks,sills,chhajjas,lintel,beam, plinthbeam etc.(B/4.10.2) |
| 12 | Providing and laying inpositionspecifiedgrade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction,finishingwithrenderingincement sandmortar1:3(1cement:3coarsesand)and making good the joints and cost ofplastizers( if required)excludingthecostofcentering, shuttering and reinforcement.M20 grade Nominal Mix / Design Mix (B/4.1) |
| 13 | Providing and laying inpositionspecifiedgrade of cement concrete for RCC structural elements upto floor five level including curing, compaction,finishingwithrenderingincement sandmortar1:3(1cement:3coarsesand)and making good the joints and cost ofplastizers( if required)excludingthecostofcentering, shutteringand reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix (B/4.3) |
| 14 | Providing and fabricating reinforcement forR.C.C. work including straightening, cutting, bending,placinginpositionandbinding (including cost ofbinding wire) all complete up to floor five level.(\"Original producers\" who manufacture billet directlyfromironoresandrollthebiletsto produce steel conforming to IS:1786) Hot rolleddeformed bars (IS : 1139). (b/4.13.2) |
| 15 | Plasteronnewsurface onwalls incement sand mortar 1:6 including racking ofjoint etc. complete fine finish : 20mm thick. (B/12.3.2) |
| 16 | Making grooves as per design in plaster 10mm to 20mm wide.(B-12.19) |
| 17 | Plasteronnewsurfaceonwallsincement sand mortar 1:4 including raking of joints etc. complete fine finish: 12 mm thick (B/12.2.3) |
| 18 | Providing and applying white cement based puttyover plastered surface to prepare the surfaceevenandsmoothcomplete New Plastered Surface (three or more coats) (B-12.22.1) |
| 19 | Distempering with oil bound washable distemper ofapprovedbrandandmanufacturetogivean evenshadeincludingallscaffolding:New work (twoormorecoats)overandincluding scrappingandprimingcoatwithcement primer. (B/12.37.1) |
| 20 | Paintingexteriorsurfaceof Wall with100% acrylic exterior paint of approved brand and manufacturetogiveanevenshadewithtwoor morecoatsincludingprepartionofbasewith sand papering, primer, putty,etc complete in all respect including scaffolding and safetyprovision New Work (B/12.43.1) |
| 21 | Applying priming coat : With ready mix pink or gray primer of approved brand and manufactureon wood work hard and soft wood.(B/12.45.1) |
| 22 | Painting with synthetic enamel paint of approved brandandmanufacture to give anevenshade : Two or more coats on new work (B/12.46.1) |
| 23 | Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) SIZE2001 TO 5000 SQ CM B-11 (11.18.2) |
| 24 | Supplyingandfixinginwallsmachinecutand polishedstoneshelves,tandsand inCM1:3 withmachinecutedges:Kotastoneminimum 30mm thick. (B/6.17.3) |
| 25 | Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average)thickcementmortar1:3(1cement3 coarse sand) and jointed with grey cement slurry mixedwithpigmenttomatchtheshadeofthe slabs,includingrubbingandpolishing completeForareaofeachslabfrom2001 to 5000 Sqcm (B-11.19.2) |
| 26 | Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge.Granite/Kota Stone Work B-7 (7.6.2) |
| 27 | Rough Chisel dressed Kota stone 35 mm thick flooring of approved shade set in pattern over 20mm thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and pointingwith cement sand mortar 1:3 with pigment to match theshade ofstone withjoint thicknessupto15mmcompleteinallrespects:(B/11.20) |
| 28 | Providingandfixing1stqualityMATfinished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid onabedofneatcementslurryfinishedwith flushpointinginthewhitecementmixedwith pigment to matchthe shade ofthe tile complete (including the costofcement mortar bed1:4).(B/7.13) |
| 29 | Providingandfixing1st quality standard white, grey,ivory,fumeredbrown,lightgreen,light blueandotherlightshadesglazedtiles confirmingtoIS:13753&IS:15622ofsize 200mmx300mminwalls,floors,steps,pillars etc. laid on a bed of neat cement slurry finished withflushpointinginthewhitecementmixed withpigmenttomatchtheshadeof thetile complete(excludingthecostofcementplaster on walls and pillar). Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mmx 300mm size. (B/7.12+7.15) |
| 30 | Providing and fixing stone slabs table rubbed, 18- 20 mm thick in Walls, Steps, Pillars, Counters, Jambs, Shelves, Sills etc. laid on 12mm (Av.) thick base of CM 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Keseriaji/ Abu Ambaji (Green Marble) SIZEABOVE 3601CM SQUARE B-7(7.3.3) |
| 31 | Providing&fixingsteel glazeddoors,windows andventilatorsshuttersofstandredrolledsteel section joint mitred and welded with steel 13x3mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:3:6 (1- Cement:3-coarsesand:6-gradedstoneaggregate 20 mm nominal size) or with wooden plugs and screwsorrawlplugsandscrewsorwithfixing clips or with bolts and nuts as required, including providingandfixingofplainglasspanes4mm thick with copper glazing clips and special metal sashputtyofapprovedmake,ormetalbeading withscrewscomplete including primingcoat of approved steel primer, excluding the cost of metal beading and other fittings except necessary hinges of pivots steel handles and peg stay etc. as required.(9.28.3) windows side hug B-9.19.3 |
| 32 | Supplyingandfixingfixedwiregaugeof14 meshx24gaugetothemetalframeofrolled section by metal beading 20x3mmwithsuitable screwatnotexceeding150mmdistance.(B/9.26) |
| 33 | ProvidingandfixingSquarebarsorotherflat welded to window, ventilatiors etc. (B/9.27) |
| 34 | Providing and fixing ofdouble leafsteel shutter for cupboard, the frame is made of pressed steel ISIsection105x60mmx 1.25mmthick with 1.00mmMSsheettospotweldedincluding holdfasts of 15x3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twin peg etc completeincluding applyingprimingcoatofapprovedsteelprimer of red oxide zinc chromate andspray painting in approvedshadewithdeco paintofapproved quality complete as per direction ofEngineer In Charge B-9 (9.39) |
| 35 | Providingandfixingexternalgradeboardsolid coresingleleafflushdoorshuttersISI2202-67 marked using Phenol formal dehyderesinin glue bothsideswithapprovedsteelfittingscomplete as per annexure \"A\": 30 mm thick . Commercial Veneer both side (B-8.13.2.1) |
| 36 | Extraforprovidingexternallippingwith2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. (B/8.14) |
| 37 | Providing and fixing Nigeria / Ghana/Ivory Coast Teakwood grade-I mouldings and beadings in doors and windows size :-25x12 mm (B-8.23.3) |
| 38 | Providing and fixing fully paneled double leaf shutter for doors as per approved design and drawing with approved ordinary C.P./oxidized steel fittings as per Annexure – A’ and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete : Wire gauge 24 gauge 14 mesh of IS designation 85 gauge wires of dia 0.56 mm panels 30 mm thick B/8.6.2 Double leaf shutter, sheesham wood gr.-I ( 24 gauge x 14 mesh ) for single leaf shutter B-8 (8.4.2.3+8.6.8) |
| 39 | Providingandfixingsteelgate,grating,and grillsmadeofangles,tees,squarebars,flats,or black pipe with holdfast and fittings complete as perdesignanddrawingincludingcutting welding and fabrication with priming coat of redoxide (B-9.8) |
| 40 | ProvidingandfixingT-ironframesfordoors, windows and ventilators of mild steel Tee- sections, joints mitred and welded with 15x3 mm lugs10cmlongembeddedincementconcrete blocks15x10x10cmof1:3:6(1cement:3 coarsesand:6gradedstoneaggregate20mm nominal size) or withwoodenplugsandscrews or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying apriming coat of approved steel primer.(B-9.5) |
| 41 | Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabillydiagonallybraced with 25x3mmflatironaboveandbelowlockrailof size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding costofchowkhats:includingtwocoatsofanit-corrosive red oxide primer paint (B-9.17) |
| 42 | Providing & fixing precast cement concrete coping1:2:4mix50mmthickcomplete as per specification : (B/3.8) |
| 43 | Providingandfixingcurtainrodsof1.25mm thick chromium plated brass plate, with two chromiumplatedbrassbracketsfixedwithC.P. brassscrewsandwoodenplugs,etc.,wherever necessary complete: 20 mm (B/8.25.2) |
| 44 | Gradingroofforwaterproofingtreatmentwith water proffing compound Cement concrete 1:2:4 (1cement:2 coarsesand :4 gradedstone aggregate 20 mm nominal size) (B/10.17.1) |
| 45 | Providinggola75x75mmincementconcrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) including finishingwithcementmortar1:3(1cement:3 fine sand) as per standard design : (B/10.22) |
| 46 | Cementconcreteflooring1:2:4(1cement:2 coarse sand : 4 graded stone aggregate) finished withafloatingcoatofneatcementincluding cementslurry,makingoflinesorgrooveetc completebutexcludingthecostofnosingof stepsetc.complete. 40mm thick with 20mm thicknominalsizeaggregate. (B/11.3.1) |
| 47 | Providing & laying broken glazed titles on roof ( brokenglazedtiles not lessthan9Kg/Sqm) on topofhot bitumen@ 1.7Kg/Sqm.(1.40Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG- 10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all completeasper direction of Engineer-in-charge. (B/10.24) |
| 48 | Supplying and Filling in plinth with blown sand underfloorsincludingwateringramming consolidatinganddressingcompleteincludingcost of sand.(B/1.27b) |
| 49 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg./Cm2.)approvedquality/make including joining the pipe with solvent cement rubber ring and lubricant. 110 mmdia(S.W. PIPE) (S-3.44.2) |
| 50 | P&F rigid PVC pipe fittings(IS: 4985mark) of approved quality/makeincluding joining the pipe with solvent cement rubber ring and lubricant:S-3(3.20)(A)Bend87.5(3.45.4) |
| 51 | (B) Bend 45 (3.45.5) |
| 52 | Providing&LayingC.C.1:5:10(Stone aggregate40mmnominalsize)allaroundS.W. pipe including 15 Cm. thick bed concrete (Width W=DiameterofpipeinCm+30Cm.)( Excludingcostofpipe)100mmdiaS.W.pipe(S/3.2.1) |
| 53 | ProvidingandFixingUnplasticizedPolyVinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked)of approvedquality/make110mm Bend 87.5 Dg. (S/3.45) |
| 54 | Door Bend 87.5* |
| 55 | Single Tee with Door |
| 56 | Vent Cowel 110mm |
| 57 | Offset (110mm dia) |
| 58 | Gully Trap |
| 59 | Nahni Trap without Jali 4\" |
| 60 | ConstructionofsepticTankinalltypesofsoil with40Cm.thickmasonry inCM1:6,15Cm thickC.Cbedof1:5:10,M-15 gradeC.C floor &RCC slab covering with M15 grade c.c. floor, 50mmthickstoneslabpartitionwalls,20mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approveddesign,twoNo.450mmdiaeach Ferro cement cover withframe, earthwork etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size200x100x130cm.(for10users)with115 mm thick RCC (M-20) slab with Tor steel reinforcement8mmϕ@15cmc/cbothways including shuttering complete in all respect.(S/3.27.1) |
| 61 | Constructionofsoakagewellinalltypeofsoil with 300 mm thick dry masonry, top and bottom 300mmcourseinCM1:6,80mmthickstone slab,jointingof slab inCM 1:3,Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring ,earthworkcompleteasperapproveddrawing includingdisposalofearthwithinaleadof50 mtr.: Size 240 Cm. dia outside & 240 Cm. depth. (S/3.22.3) |
| 62 | Construction of manholein all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6,10Cm.thickcementconcrete1:5:10in foundation,20mmthickinsideplasterinCM 1:6,finishedwithfloatingneatcement,50mm thickM-15gradeC.C.flooring,making channels,80mmthickstoneslabcoveringwith 40mmthickM-15gradeC.C.flooring,Cement coverwithframe of450mmdia,earthworketc. completeasper designincludingdisposalof surplusearthwithin50mtr.lead.Depthupto0.5 M (S/3.19.1) |
| 63 | Construction of chamberin all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C.1:5:10infoundation,20mmthickinsider plasterinCm1:6,finishedwithfloatingneat cement, 50mm thick M-15 grade C.C. flooring , earthworketc.completeasperdesignincluding disposal of surplus earth within a lead of 50 mtr. Insidesize300X300mmdepthupto0.5MCement cover with frame. (S/3.21.1) |
| 64 | P&FIndiantypewhiteglazedvitreouschina 1st quality W.C. orissa pan (IS :2556 Mark) with 100mmvitreouschinaPorStrapincluding cutting and making good the wall and floor: Size 580x440mm. (S/1.2.2) |
| 65 | P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor (S/1.3) |
| 66 | P&FwaterclosetSeatCoverswithbrass hingescomplete:SolidPVC(ISImarked) grade-I White for EWC.(S/1.7.2) |
| 67 | P&FJetspray forwaterclosetwithC.P. Copper Tube flange of approved make. (S/1.59) |
| 68 | P & F Low level FlushingCistern of 10 litres capacity(IS:2556mark)ofapprovedmake with complete fittings C.I. brackets duly painted,brassballcockwithball,(IS:1703 mark) complete including cutting and making goodthewall:PVCwithPVCbendasper IS:7231.(S-5/1.20.2) |
| 69 | P&FWVCWashbasin(IstqualityIS:2556 Mark) of approved make with C.I. brackets duly painted1No.15mmC.P.Pillarcock(IS:8934 Mark)&32mmC.P.brasswastecouplingof approvedmake,P.V.CWastepipewithPVC nut 32 mm complete including cutting & making good the wall : Size 550 mm x 400 mm(S/1.36.3) |
| 70 | P & F 15 mm. Dia Connection pipe of approved quality/make: PVC pipe with C.P. Brass nuts up to length 450 mm. (S-21/2.13.3) |
| 71 | P&FLookingMirrors withP.V.C.frameof approvedmakeasperdirectionofEngineer-in- charge Size 500x400mm (S/1.45.1) |
| 72 | P&Ftowelrailorringofapprovedquality/make:C.P.brasstowelrailelbowtypewith concealedscrewssize600 mm (heavy duty) S/1.47.2 |
| 73 | P & F Towel Rail or Ring of approved quality/make:C.P. Brass Towel Ring revolving type S-1(1.47.8) |
| 74 | Construction ofCement concretechamber 125mm dia on depressedfloor upto 45cm height fromfloorwith:C.P.Brassdoomgrating.(S/ 3.39.2 ) |
| 75 | P&F Bath Shower of approved quality/make: C.P. brass of Heavy & superior quality, revolving with adjustable key150mm. S / 1.55.3 ) |
| 76 | P&F Shower arm 15mm dia of approved quality/make.C.P.brassheavy&superiorquality 150mm projection.(S/1.54.1) |
| 77 | P & F Bib Cock (IS:8931 Mark) Superior quality of approved make : (S- 19/,2.7.3,2.7.4,2.32.5) C.P. Brass Long body,15mm nominal bore weight not less than 690 gm |
| 78 | P & F Stop cock (IS:8931 Mark) superior quality & of approved make : ( S/ 2.8.5) C.PBrass Concealed Stop Cock 15mm |
| 79 | 1.0mmthickstainlesssteelAISI-304&IS 13983-1994 kitchensinkofapprovedmakeas per Engineer-in-chargewith large waste coupling. 37 x 18 x 717x15x7 (with drainboard) (S/1.38.9.4) |
| 80 | P&FPVCStorageTank ISIMarked(IS: 12701) indicating theBIS license No),of approvedmakewithcover,25mmdia1Mlong G.I.over-flowpipe&25Cm.longwashout pipe with plug & socket, including making connectionetc.,completeofapproveddesign:500 liters capacity (S/2.26.3) |
| 81 | P & F Ball Cock (IS:1703 Mark) with Rod &P.V.C. Ball complete : Brass wt. Not less than 300 gm,15mm. (S/2.11.1) |
| 82 | P & F Full-way Valve(IS:778 Mark) or wheel valve of approved make : Gun-metal 15mmnominal bore.(S/2.15.1) |
| 83 | Gun-metal 25mm nominal bore (S/2.15.3) |
| 84 | ProvidingandfixingChlorinatedPolyvinyl Chloride (CPVC)pipes(IS15778:2007code) havingthermalstabilityforhot&coldwater supply including all CPVC plain & brass threadedfittingsi/cfixingthe pipe withclamps at1.00mspacing. Thisincludes jointingof pipes&fittingswithonestepCPVCsolvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealedworkincludingcuttingchasesand making good the walls etc.,) 15 mm nominal size(S/2.38.1) |
| 85 | ProvidingandfixingChlorinatedPolyvinyl Chloride (CPVC)pipes(IS15778:2007code) havingthermalstabilityforhot&coldwater supply including all CPVC plain & brass threadedfittings,thisincludedjointingofpipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work). 25 mm nominal size (S/2.39.3) |
| 86 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.brass (IS 8931 marked)(S-21/2.12.1) |
| 87 | P&FBibCock(IS:8931Mark),Superior quality of approved make: C.P. Brass bibcock,15mm nominal bore. (S/2.7.3) |
| 88 | Providing and fiixng C.P. flange for 15mm dia tap.s (S/1.60) |
| 89 | Wiringoflightpoint/fanpoint/exhaustfan point/ call bell point with 1.5 sq. mmnominalsizeFR PVCinsulated unsheathed flexible copperconductor1.1kV grade and1.5sq.mmnominalsizeFRPVC insulated unsheathedflexiblecopperearth conductor 1.1 kV grade(IS:694)in recessed ISImarkedMMS(IS:9537P-III)virgin material PVCconduit&it\"s ISImarked (IS:3419-1988) accessories,roundtiles,1.2 mm thick HotDipped Galvanized Modular Box withearthterminal,10AModular switch,Modular face plate withgrid plate,3pin ceilingrose/Holder/3way connector, screws, making connections, testing etc. as required. For specification of copperConductor, Phenolic Laminated sheet\"s &Electrical/ Wiring accessoriesrefer Chapter E-04,E- 05 & E - 07 For additionaltechnicalparametersof product / work refer Annexure \"A\"attached with this BSR A. Short Point E1.1.1 |
| 90 | B. Medium Point E1.1.2 |
| 91 | C. Long point E1.1.3 |
| 92 | Wiring of 3/5 pin 6 amp. Light plug point with1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSROn board E1.3.1 |
| 93 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copper Conductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSRLong point (up to 10 mtr.) E1.2.3 |
| 94 | Supplyingandfixingofpowerplugpointwith ModularaccessoriesasperPWDspecification forelectricalWorks,onhotdippedgalvanized modular box of 1.2 mmthick with earthing terminal/connector on surface or in recessed with suitablesizeofmodularfaceplacewithgrid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16amp.socketoutlet(IS:1293)making connection , testing , etc. as required. For specification ofWiring accessories refer Chapter E-07 relateditem&Foradditional technicalparameters of product / work refer Annexure \"A\" attached with this BSR E7.37 |
| 95 | SupplyinganddrawingFRPVCinsulated& unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen freeforlesschancesofoxidization,insulation PVCtypeA/C/D,flameretardantasperIS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. asrequired.OEMMusthaveitsowninhouse NABL lab setup for all testing facilities for wires.Foradditionaltechnicalparametersof product / work refer Annexure \"A\" attached with this BSR A. 1 x 1.5 Sq mm E4.1.1 |
| 96 | B. 2 x 2.5 Sq mm E4.1.6 |
| 97 | C. 2 x 4.0 Sqmm E4.1.11 |
| 98 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/Dtrippingcharacteristicaspertypeofload and siterequirement)4KVimpulsewithstand voltage, ISI marked IS 8828(1996) / conforming toIEC60898-12002,IEC60947-2,lowwatt losses, trip free mechanisum , energy limiting of class 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existingdistributionboard/sheets,minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All asperpreapprovedbyEngineerincharge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Single pole MCB6A TO 32A Rating E6.1.1.2 |
| 99 | Providing & Fixing of ISI marked surface type buzzer (IS:2268-1994) with CM/L no. printed including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . (E/7.24) |
| 100 | P&F1.2mmthick M.S.Recessedfanbox, hexagonal/roundofsize130mmdia,depth 75mm, 12mmdiarodfanhookwith100mm lengthextendedoneachside.Allasperpre approvedby Engineerincharge. For additional technicalparameters of product / work refer Annexure \"A\" attached with this BSR E15.10 |
| 101 | Providing&Fixingof BEE Starratedcopper wounded double ball bearing capacitor start, aluminiumbody&Metallic bladeceiling fan Conforming to all the performance requirements laiddowninIS374:2019includingall amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulatedflexiblecopperconductormaking connection testing etc. as required. All as per pre approvedby Engineerincharge. For additional technicalparametersofproducts/work ,refer Annexure \"A\" attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) E15.7.3 |
| 102 | Providing&Fixingof240/415Visolator ISI markedIS:13947-III/conformingtoIEC60947- 3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication, Redcolourdolly/levershall have singlemouldcoveringoverallpolesfor operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediatedlabtypetestreports &Allasper preapprovedbyEngineerincharge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR(A) 63 A rating Double pole Isolator G -2 E6.2.1.2 |
| 103 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door(Metal/Glazed)Distributionboardwith Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 /IEC 61439- 1 & 3, powder painted complete with reversible door (fordoubledoorDBonly)100amp. insulated copper busbar/shortinglink, copperneutral link, copper earth link , color coded interconnectingwireset ofsuitableratingand din bar,masking sheet,making internal DB terminations with copper lugs, Ferrules, detachablegland plate, includingmaking connections,testing etc.as required.OEM shall have submitNABL / CPRI / ERDA accrediated labtypetestreports &All asperpre approved byEngineerincharge.Foradditionaltechnical parameters of product / work refer Annexure \"A\" attachedwiththisBSR(A)GlazeddoorSingle phase 12 way E6.10.2.4 |
| 104 | Providing & Fixing of IS 11037:1984marked non modular socket size flush type 120 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . E7.20 |
| 105 | Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . 300 mm sweep E15.11.2 |
| 106 | Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .E7.13 |
| 107 | Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulbin existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70,minimum life time of minimum25000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard andtrade mark certificate ( T.C.)Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures.LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure \"A\" attacheded with this BSR. 9 watt E17.9.3 |
| 108 | Providing & Fixing of IP-20 LED Recessed / Surface Mounted,Round/SqaureSMDMidPowerLED Downlight with power coated die-cast aluminum housingwithUVStabilizednonyellowishDiffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuitprotection, having efficiency > 85% . System Lumenefficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time ofminimum50000BurningHourswith,70%of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standardandtrademarkcertificate(T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screenprintingonhousing.OEMmust have its own in house NABL lab setup for all testing facilitiesforLEDfixtures.(LM79&LM80) certificate / Report from OEM shall be submitted. All as per pre approvedby Engineer in charge. For additionaltechnicalparametersofproducts/work, referAnnexure \"A\" attached with this BSR .Minimum lumen output 1950 lm. Code-17.3.1.5 |
| 109 | Providing & Laying P.V.C. / XLPE insulated &P.V.C.sheathedUn-Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P- I of1.1KVwith H4-Gradeelectrolytic aluminiumconductorconfirmingtoIS8130of purity >99.6 %,Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware/ PVCpipe/ openduct/cable trench/Cable tray (with cable tie) includingtesting etc. as required offollowingsize.OEMmusthaveit\"sownin houseNABLaccrediatedLaboratoryfortesting procedureasperIS:10810.Foradditional technicalparameters of product / work refer Annexure \"A\"attachedwiththis BSR10sq.mm4.0 Core E11.1.3.3 |
| 110 | PlateEarthing asperIS:3043withHotdipped G.I.Earthplateofsize600mmx600mmx 6.0mmbyembodying 3to4mtr.belowthe groundlevelwith20 mmdia.G.I.\"B\"class watering Pipe ,including all accessories like nut, bolts,reducer,nipple,wiremeshedfunnel,and Heavydutyweatherproofpoly-propyleneearth pitchamberwithlockableJamfreelidsuitable forsafeworkingload5000Kgormoreofsize Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm.andHeight 250to300mm.and embodying the pipecomplete with alternate layerssaltandcoke/charcoal,testingofearth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer incharge. For additional technical parameters of products/ work ,referAnnexure\"A\"attachedwiththis BSR .E14.2 |
| 111 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . 10 SWG G.I. ( Hot Dipped) WireE14.6.9 |
| 112 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincluding cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 25 mm E1.4.2 |
| 113 | Providing & Fixing of IP65 IK08 rated Integrated SMD Mid power LED bulk head type light fixture made from Pressure Die Cast AL housing suitable with integral driver, system lumen efficacy ≥100 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As perANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shallbe ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. surge protection 4 KV. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .Minimum lumen output 1000 lm E17.6.1 |
| 114 | Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .15 Ltr.E16.1.3 |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail