| 1 | Construction of Shed for Cleaning and Grading & Shorting Unit – 106.993 Sq. Mt |
| 2 | CIVIL WORK FOR FACTORY SHEDExcavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingtheexcavatedmaterialuptoa distanceof50m.beyondthebuildingareaand stackingand spreadingasdirected,dewatering,preparingthebedforthe foundationand necessary back filling, ramming, watering includingshoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.)(Lift from 1.5m to 3.0m) By Manual Means. |
| 3 | Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineerincharge inlayersof15cm to 20cmincludingwateringandcompactionetc. complete. |
| 4 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fineaggregate (Crushed sand VSI Grade) |
| 5 | ProvidingpreconstructionalantitermitetreatmentasperI.S.6313 (Part-II)bytreatingthe bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percentofchlorophyrifos persquaremeterofsurfaceareacovering10yearsguaranteeon bond paper. |
| 6 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite /quartzite/gneissmetalforR.C.C.workin foundationslike raft,strip foundations,grillage and footings ofR.C.C. columns and steel stanchions etc. including bailing out water, Steel centering,formwork,coverblocks,laying/pumping, compaction andcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. |
| 7 | ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-20oftrap/granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcementand structural steel).withfullyautomaticmicroprocessorbasedPLC with SCADA enabledreversibleDrumTypemixer/concreteBatch mixplant(Panmixer)etc. complete. With fine aggregate (Crushed sand VSI |
| 8 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting androughening the surface ifspecial finish is to be provided and curing complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbased PLCwithSCADA enabledreversibleDrum Typemixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate |
| 9 | Providing and fixing in position TMT - FE - 500 bar Reinforcement of various diameters for R.C.C.pilecaps,footings,foundations, slabs,beamscolumns,canopies,staircase,newels, chajjas,lintels pardis,copings,fins,archesetc.asperdetaileddesigns,drawings and schedules. including cutting, bending, hooking the bars, bindingwith wires or tack welding and supporting as required complete. |
| 10 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6insuperstructureincluding strikingjoints,rakingoutjoints,wateringand scaffolding etc. |
| 11 | Providinginternalcementplaster12mm thickinsinglecoatin cementmortar1:4without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. |
| 12 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positionsincludingbasecoatof15 mmthickincementmortar1:4usingwaterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping thesurfaceofthebasecoatroughtoreceivethesand facedtreatment6to8mm thickin cementmortar1:4finishing thesurfacebytakingoutgrainsandcuringforfourteendays |
| 13 | Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffoldingand preparing the surface by brushing and brooming down etc. complete. |
| 14 | Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. |
| 15 | Providing and laying in situ cement concrete M20 with tremix treatment for 100mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. |
| 16 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing,gussetplatesetc.asper detaileddesignsanddrawingsorasdirectedincluding cutting, fabricating,hoisting,erectingfixinginposition,Makingriveted/ bolted/welded connectionandone coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. |
| 17 | Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers andstepsof18mmdia.mildsteelbarfor watertankincludingfixingitin(1:2:4)M-15 cementconcrete block60cmx30cmx30cmandpaintingtheladdercomplete. |
| 18 | Providing and fixing corrugated galvanised iron sheets of 0.63 mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete. (Weight of 5.5 kg / sqm.) |
| 19 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of |
| 20 | Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain/ obscuredglass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm |
| 21 | ELECTRIFICATION Supplying and erecting mains with 3 x 2.5 sq.mm FRLSH copper PVCinsulated wire laid in provided conduit / trunking / inside pole / Bus bars or any other places as per specification No: WG-MA/BW |
| 22 | Supplying and erecting LED Panel Light (600mm X 600mm) Max. 30 having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 23 | Point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthingand required accessories as per specification No: WG-PW/SW |
| 24 | Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75 m) length respectively and total 8.0 m long with pole cap, base plate in providedfoundation. (weight 101 kg) as per specification no. OH- PL/STP |
| 25 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 26 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia.G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 27 | Supplying, erecting & marking DP-MCB 6A to 32A, C-series withrated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 28 | Supplying, erecting & marking DP-MCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provideddistribution board as per specification no. SW-SWR / MCB |
| 29 | Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinccoating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 30 | Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete withcompliance to IS 720:2010 |
| 31 | Wiring for plug on board with Switch socket surface/concealed type, copperwiring and earthing and with modular accessories as perspecification No: WG PW/CW |
| 32 | Supplying and erecting regular/ standard model ceiling fan of 900/1050 mm. sweep complete erected in position as per specification no. |
| 33 | Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiringconnections and lugs etc. in provided distribution board. |
| 34 | LAB TESTING Comp. Strength- Cube |
| 35 | Crush Metal- Basic Test |
| 36 | Gradation |
| 37 | Comboned Flakiness and Elongation of single metal |
| 38 | Cement- Fineness, Consistency, setting time, Compressive strength, Specific gravity |
| 39 | Sand Fineness Modulus, Silt Content |
| 40 | Water absorption ( Set of 5 Bricks),Compreesive strength ( Set of 5 Bricks), Efflorescence ( Set of 5 Bricks) |
| 41 | Concrete Mix Design (With all Tests on basic materials) |
| 42 | C.B.R. Test ( Lab ) With compaction |
| 43 | Royalty ChargesSAND |
| 44 | METAL Hand broken |