| 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared. |
| 2 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 3 | 300x16 mm |
| 4 | 250x16 mm |
| 5 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 6 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 7 | a) 200x10 mm |
| 8 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 9 | a)100 mm |
| 10 | b) 75 mm |
| 11 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 12 | a) Twin rubber stopper |
| 13 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 14 | 80x1.25 mm M.S. laths with 1.25 mm thick top cover. |
| 15 | Providing and fixing ball bearing for rolling shutters. |
| 16 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 17 | a)Hot finished welded type tubes. |
| 18 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, |
| 19 | shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 20 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) |
| 21 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 22 | a) Upto 60 degree pitch |
| 23 | 12 mm cement plaster of mix : |
| 24 | 1:6 (1 cement: 6 coarse sand) |
| 25 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. |
| 26 | Two or more coats on old work. |
| 27 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 28 | a)New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 30 | Two or more coats on new work. |
| 31 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 32 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge. |
| 33 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 34 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 35 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 36 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge |
| 37 | Dismantling of existing aluminium partitions, doors and other frames including proper numbering, stacking and placing all the materials at the required place in the building as directed by the Engineer-in-charge. (Area of partition being dismantled shall be measured for payment) |
| 38 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the servicablematerial in 50 m lead and disposal of unservcieable material away from the compound into dump yard as directed by Engineer incharge. |
| 39 | Asbestos cement sheet |
| 40 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 41 | 20 mm nominal outer dia. Pipes. |
| 42 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work |
| 43 | 40 mm nominal outer dia. Pipes. |
| 44 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 45 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 46 | 15mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 47 | Providing and fixing PTMT stop cock of approved quality and colour. |
| 48 | 15 mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 49 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 50 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 51 | Fixing of asbestos cement 6mm thick corrugated sheets upto 60 degree pitch roofing and fixing with G.I J or L hooks, bolts and nuts 8mm dia G.I plain and bitumen washers complete excluding the cost of purlins, rafters and trusses corrugated sheet.(AC Sheets supplied by department at no cost) |
| 52 | Credit /Rebate fortaking away thedamaged/unserviceablesteel rolling shutter material as per direction of Engineer-in-charge |
| 53 | Making and fixing of aluminum partitions and doorsin position after sorting required sections as per the drawingwith available material of aluminum sections, particle board, glass panels and snap on beading including fixed with new rawl plugs and screws, neoprene gasket or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions at top, bottom and sides with required PVC/Neoprene felt etc, aluminum sections shall be cleaned properly, and shall be mitered and jointed mechanically wherever required all complete as per the architectural drawings and the directions of the Engineer-in-charge. (The available aluminium materia, glass, board etc., excluding screws as is where is basis in stacked condition wiil be supplied by the department at no cost.Cost includes shifting of materials from the building store to the workplace. Finished area of partition with board/glass panels/grill shall be measured for payment) |
| 54 | Transportation of aluminium partitionmaterial of area approx. 80 sqm from any BSNL compoundwithin a distance of approx. 20.00 KM to Cantonment Bollaram stores including loading, unloading and stacking at designatedplace of site of work all completeas directed by the Engineer-in-charge |