| 1 | CIVIL WORKS |
| 2 | Reinforcedcementconcrete workinbeams,suspended floors,roofshavingslopeupto15°landings,balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excludingthecostofcentering,shuttering,finishingand reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand (zone- III)derived from natural sources: 3 gradedstone aggregate 20 mmnominal size derived fromnatural sources). |
| 3 | SteelreinforcementforR.C.C.workincludingstraightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 4 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 5 | Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. Raj nagar plain white marble/ Udaipur green marble/ Zebra black marble 8mm thick |
| 6 | Providingandfixinginwallliningflatpressedthreelayer (medium density) particle board or graded wood Pre-laminated onesidedecorativelaminationandothersidebalancing lamination Grade I, Type II, IS : 12823 marked, including priming coat on unexposed arrangement and screws etc. complete :-12 mm thick |
| 7 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately):- Second class teak wood |
| 8 | ProvidingandfixingIstqualityceramicglazedwalltiles conformingtoIS:15622(thicknesstobespecifiedbythe manufacturer), of approved make, in all colours, shades except burgundy,bottlegreen,blackofanysizeasapprovedby Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, includingpointinginwhitecementmixedwithpigmentof matching shade complete. |
| 9 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of : (Note:- Butt hingesand necessary screws shall be paid separately)12 mm thick pre-laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT- I or graded wood particle board FPT- I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and pre-laminated conforming to IS : 12823, Grade 1, Type - II marked : |
| 10 | Providing and fixing 25 mm thick shutters for cup board etc. :-Panelled or panelled & glazed shutters Second class teak wood including iSi marked nickel plated bright finished M.S. piano hinges with necessary screws |
| 11 | Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked,withonesidedecorativeandothersidebalancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately):- 25 mm thick |
| 12 | Providingandfixingspecialqualitybrightfinishedbrass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete:- 75 mm |
| 13 | Providing and fixing 50 mm bright finished brass cup board or wardrobe knob of approved quality with necessary screws. |
| 14 | Providing and fixing bright finished brass handles with screwsetc. complete:- 125 mm |
| 15 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 16 | Providingandfixingaluminiumdiecastbodytubulartype universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screwsetc. complete. |
| 17 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handlesof approved qualitywith necessaryscrews etc. complete. |
| 18 | Providingand fixingmagnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessaryscrews etc. complete:- Triple strip vertical type |
| 19 | Providing and fixing powder coated telescopic drawer channels300mmlongwithnecessaryscrewsetc.completeasper directions of Engineer- in-charge. |
| 20 | Providingandfixingslidingarrangementinracks/ cupboards/cabinets shutter by with stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately) |
| 21 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm),with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’sspecificationanddirectionofEngineer-in- chargeExtruded section profile size 42x50 mm |
| 22 | Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforcedwith1.60±0.2mmthickgalvanizedmildsteel sectionmadefromrollformingprocessofrequiredlength (shape&sizeaccordingtouPVCprofile),,uPVCextruded glazingbeadsofappropriatedimension,EPDMgasket,G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plasticpackers,plasticcapsandnecessarystainlesssteel screwsetc.Profileofframeshallbemitredcutandfusion welded at all corners, mullion (if required) shall be also fusion weldedincludingdrillingofholesforfixinghardware\"sand drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.(Single/ double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Using R3 series with frame (55mm & above) x (40mm & above) & sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system (Height upto 1.8m). |
| 23 | Providingand fixingfactory madeuPVC whitecolour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extrudedprofilesdulyreinforcedwith1.60±0.2mmthick galvanized mild steel section made from roll forming process of requiredlength(shape&sizeaccordingtouPVCprofile), appropriatedimensionofuPVCextrudedglazingbeadsand uPVCextrudedinterlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.(Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (70mm & above) x (40mm & above) & both glazed and fly screen sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre). |
| 24 | Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/top hung uPVC windows, of approved quality, with necessarystainlesssteelscrewsetc.asperdirectionof Engineer-in-charge. 400 x 19 x 1.9 mm |
| 25 | Providingandfixingcasementhandlemadeofzincalloyed (whitepowdercoated)foruPVCcasementwindowwithnecessary screws etc. complete. |
| 26 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 27 | Chequerredprecastcementconcretetiles22mmthickin footpath & courtyard, jointed with neat cement slurry mixed with pigmenttomatchtheshadeoftiles,includingrubbingand cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) . Light shade pigment using white cement |
| 28 | 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. White sand stone |
| 29 | 38 mm thick wood block flooring of first class teak wood laid over 25 mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen penetration 80/25 (blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blowntype)uptohalf depth,planed, levelledsmooth and finished complete. |
| 30 | Providingandlayingvitrifiedfloortilesindifferentsizes (thicknesstobespecifiedbythemanufacturer)withwater absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm |
| 31 | ProvidingandlayingVitrifiedtilesinfloorindifferentsizes (thickness tobe specifiedby themanufacturer)with water absorptionless than 0.08% andconforming to IS:15622,of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of Size of Tile 600 x 600 mm |
| 32 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed withcementslurryandpointingwithwhitecementslurry admixed with pigment of matching shade including rubbing , curingandpolishingetc.allcompleteasspecifiedandas directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown,Cat Eye or equivalent. |
| 33 | Providing and fixing false ceiling at all height including providing andfixingofframeworkmadeofspecialsections,power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flangeof cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts ofrequiredsizeandotherendofanglehangerfixedwith intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for 12.5 mm thick tapered edge gypsum moisture resistant board |
| 34 | Polishing on wood work with ready mixed wax polish of approvedbrand and manufacture :New work |
| 35 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 36 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than50grams/litreofapprovedbrandandmanufacture, including applying additional coats wherever required to achieveeven shade and colour. Two coats |
| 37 | Removing white or colour wash by scrapping and sand paperingand preparing the surface smooth including necessary repairs to scratches etc. complete |
| 38 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 39 | Re-letteringwithblackJapanpaintofapprovedbrandand manufacture. |
| 40 | Finishing walls with Premium Acrylic Smooth exterior paint withSilicone additives of required shade Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) overexisting cement paint surface |
| 41 | Demolishing cement concrete manually/ by mechanical means includingdisposalofmaterialwithin 50metres leadasper direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 42 | DemolishingR.C.C.workmanually/bymechanicalmeans including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 43 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres |
| 44 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 45 | For thickness of tiles above 25 mm and up to 40 mm |
| 46 | Demolishing brick tile covering in terracing including stacking of serviceablematerialanddisposalofunserviceablematerialwithin 50 metres lead. |
| 47 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50metres lead : Thickness above 25 mm up to 40 mm |
| 48 | Dismantlingof flushingcisternof all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 49 | Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain withrubber plug,40 mmC.P. brasswastecomplete, including painting the fittings and brackets, cutting and makinggood the walls wherever required:-White glazed fire clay kitchen sink of size 600x450x 250 mm |
| 50 | Providing and fixing CP Brass Single lever telephonic wall mixerof quality & makeas approved by Engineer in charge. (a) 15 mm nominal dia |
| 51 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : Flat back wash basin of size 630x450 mm |
| 52 | Providing and fixing toilet paper holder : C.P. brass |
| 53 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic watercloset of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection withtheexistingP/Strap,completeinallrespectasper directions of Engineer-in-Charge. |
| 54 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable lockingarrangementandmakingnecessaryholesforinlet, outletandoverflowpipesbutwithoutfittingsandthebasesupport for tank. |
| 55 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore |
| 56 | Providing and fixing 12 mm thick frameless toughened glass doorshutterofapprovedbrandandmanufacture,including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 57 | Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand)20mmthickwithneatcementpunningmixedwithwater proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough Kota stone |
| 58 | BLINDS WORKVertical blinds :Providing and fixing vertical blinds Vista Leveller Make with 100/89 wide imported superior polyester base fabric vanes with scotch guard application as per approved sample, make of Vista leveller or equalent and the ranges of louver shall be in select and classic. The vertical blinds shall have a head rail of extruded anodized high strength aluminium alloy or equalent. End control unit consists of reduction gearbox for a very smooth operation of the blind. This unit consists of planetary gear in the outer housing, four small transmission gears fitted in the middle assembly and a end receiving gear attached to central sprocket unit. Tilter chain is made of plastic beads moulded on thick polyester card. The pitch of the beads is ±6mm. The end control unit havethefacility torotatethelouverby 180degrees.( Location:FORALLWINDOWS)andasperspecifiedby Engineer-In-Charge |
| 59 | Providingandfixingstainlesssteeltowelrailcompletewith bracketsfixedwithCPbrassscrews withconcealed fittings arrangement of approved quality and colour. Towel Ring Inner Diameter 150 mmNominal Diameter of Rod 23 mm Length of Towel Rail(mm) 600 TotalLengthofTowel Ring(mm)1100millimeter &as perspecified by Engineer-In_charge |
| 60 | Providing & fixing of Jet Spray in the existing WC Sheet including connection,testing,CmmisioningEtc.asrequired.15mmnominal dia |
| 61 | Providing & fixing of Steam Bath & Showers with glass frame of size (1.75 Mtr x 1.50 mtr) Material: Wood & glass, Sliding door with a secure locking mechanism, Slip-resistant floor1. *Power*: Typically 3-12 kW (10,000-40,000 BTU)2. *Steam output*: 3-12 kg/h (6.6-26.4 lb/h)3. *Temperature*: 100°C - 115°C (212°F - 239°F)4. *Humidity*: 100% relative humidity5. *Control*: Thermostat, timer, and/or remote control*Interior Features*1. *Seating*: stool for comfortable seating2. *Lighting*: LED lighting for ambiance3. *Ventilation*: Proper ventilation system to remove excess moisture4. *Shelves*: Aromatic oil or accessory shelves*Safety Features*1. *Automatic shut-otf*: In case of malfunction or overheating2. *Temperature limit*: Prevents excessive temperature3. *Pressure relief valve*: Releases excess pressure4.*GFCIprotection*:Groundfaultcircuitinterrupterfor electrical safety5. *Emergency stop*: Easily accessible button or lever to stop the steam generatoras per specifications Engineer-In-Charge. |
| 62 | Providing & fixing of Steam Bath & Showers with glass frame of size (2.36 Mtr x1.5mtr) Material: Wood & glass, Sliding door with a secure locking mechanism, Slip-resistant floor1. *Power*: Typically 3-12 kW (10,000-40,000 BTU)2. *Steam output*: 3-12 kg/h (6.6-26.4 lb/h)3. *Temperature*: 100°C - 115°C (212°F - 239°F)4. *Humidity*: 100% relative humidity5. *Control*: Thermostat, timer, and/or remote control*Interior Features*1. *Seating*: stool for comfortable seating2. *Lighting*: LED lighting for ambiance3. *Ventilation*: Proper ventilation system to remove excess moisture4. *Shelves*: Aromatic oil or accessory shelves*Safety Features*1. *Automatic shut-otf*: In case of malfunction or overheating2. *Temperature limit*: Prevents excessive temperature3. *Pressure relief valve*: Releases excess pressure4.*GFCIprotection*:Groundfaultcircuitinterrupterfor electrical safety5. *Emergency stop*: Easily accessible button or lever to stop the steam generatoras per specifications Engineer-In-Charge. |
| 63 | Providing & fixing SSname boardWith Polished stainless steel/ SS Golden letter, Size (200 mm x 50mm)-INDO TIBETAN BORDER POLICE NIWAS with ITBP Logo)as perapproved drawing & designby Engineer -In-Charge |
| 64 | ELECTRICAL WORKS |
| 65 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit as required:- 2 x 1.5 sq. mm |
| 66 | 4 x 1.5 sq. mm |
| 67 | Supplying and fixing of following sizes of steelconduitalongwithaccessoriesin surface/recess including painting in case of surfaceconduit,orcuttingthewalland making good the same in case of recessed conduit as required:- 25 MM |
| 68 | Supplying and fixing of following sizes of medium class PVC conduitalongwith accessories in surface/recess including cuttingthewallandmakinggoodthesame in case of recessed conduit as required:- 25 MM |
| 69 | Supplying and fixing following modular switch/socketontheexistingmodularplate &switchboxincludingconnectionsbut excluding modular plate etc. as required:- 2 way 5/6 A switch |
| 70 | 15/16 A switch |
| 71 | Supplying and fixingtwo module stepped type electronic fan regulator on the existing modularplateswitchboxincluding connectionsbutexcludingmodularplate etc. as required. |
| 72 | Supplyingandfixing3pin,5Aceiling roseontheexistingjunctionbox/ wooden block including connections etc. as required. |
| 73 | Installation of exhaust fan in the existing opening,includingmakinggoodthe damage,connection,testing,commissioning etc. as required. Upto 450 mm sweep |
| 74 | Extra for fixing the louvers/ shutters completewithframeforaexhaustfanofall sizes. |
| 75 | Supply,installation,t estingand commissioningoffollowingminimum capacity4-wayflowVRV/VRFCassette Type Indoor ceiling mounted unit equipped withsyntheticwashablemediapre-filter, fan section with low noise fan/dynamically balancedblower,multispeedmotor, coilsectionwithDXCoppercoil,electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordlessremotecontroletc.,suitablefor operation on single phase230V±10%, 50HzACsupply,complete,asrequired. The unit shall have automatic force shutdownprovisionincaseoffireon receivingsignalfromBMSSystem.The coolingcapacityofindoorunitwillbeatair inlet conditions of 27 Degree CDB and 19 Degree CWB temperature. 2 TR |
| 76 | Supply,Installation,Testingand Commissioning of 1200 mm sweep, BEE 5 starrated,ceilingfanwithBrushLess DirectCurrent(BLDC)Motor,classof insulation:B,3 nos.blades,30 cmlong downrod,2 nos.canopies,shacklekit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM,350 RPM(toleranceasperIS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degreeC(max.),insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 77 | Supply ,Installation of followings sizes exhaust fan of mate body complete with louvers/shutters in the exiting opening 1.c. makinging the hole to suit the size of the above tan, making good the damage and connectionwith1.5sqmmFRusPVC insulated copper conductor singlecore cable and testing, commissioning etc.a sr e q u i r e d3 0 0 m ms w e e p 900rpm, heavy duty |
| 78 | Supplying,installation,testing& comissioning of Mirror light1Ow LED including fixing arrangement, connection with 1.5sqmm FRLS PVC insulated copper conductor single corecable complete as required. (MakeBajaj/Philips/Surya/Havells/Wipro) |
| 79 | Providing & Fixing LED Motion detector ceiling light (30 Cm x30 cm ) including wiring,bracketswalkinareaandbatharea make the wall good and as specified by Engineer-In-Charge. |