| 1 | SCHEDULE A PART I (BUILDING WORKS) |
| 2 | Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartI . |
| 3 | SCHEDULE A PART II (INTERNAL WATER SUPPLY) |
| 4 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Sch ‘A’ PartII. |
| 5 | SCHEDULE A PART III (INTERNAL ELECTRIFICATIONS) |
| 6 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONS as listed in Sch ‘A’ PartIII. |
| 7 | SCHEDULE A PART IV (EXTERNAL WATER SUPPLY) |
| 8 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Sch ‘A’ PartIV . |
| 9 | SCHEDULE A PART V (EXTERNAL ELECTRIFICATION) |
| 10 | Lump sum price worked out by the contractor forEXTERNAL ELECTRIFICATION as listed in Sch ‘A’ PartV |
| 11 | SCHEDULE A PART VI (SEWAGE DISPOSAL) |
| 12 | Lump sum price worked out by the contractor for BSEWAGE DISPOSAL as listed in Sch ‘A’ PartVI |
| 13 | SCHEDULE A PART VII (AREA DRAINAGE) |
| 14 | Lump sum price worked out by the contractor for BAREA DRAINAGE as listed in Sch ‘A’ PartVII |
| 15 | SCHEDULE A PART- VIII (ROAD/PATH AND CULVERT) |
| 16 | Lump sum price worked out by the contractor for ROAD/PATH AND CULVERT as listed in Sch ‘A’ PartVIII |
| 17 | SCHEDULE A PART- IX (FENCING AND GATE) |
| 18 | Lump sum price worked out by the contractor forCOMPOUND WALL, FENCING AND GATEas listed in Sch ‘A’ Part IX |
| 19 | SCHEDULE A PART- X (EARTHWORK AND SITE CLEARANCE) |
| 20 | Lump sum price worked out by the contractor forEARTHWORK AND SITE CLEARANCE as listed in Sch ‘A’ Part X |
| 21 | SCHEDULE A PART- XI (DEMOILTION AND DISMANTLING) |
| 22 | Lump sum price worked out by the contractor for Demoilition and Dismanting as listed in Sch ‘A’ Part XI |
| 23 | SCHEDULE A PART- XII (INTERNAL E/M SERVICES HOT WATER SUPPLY) |
| 24 | Lump sum price worked out by the contractor for Internal E/M Servicews (Hot water Supply) as listed in Sch ‘A’ Part XII |
| 25 | Supply and fixing brass Y straner with SS 304 filter 20mm bore ISI marked complete all as specified and directed. |
| 26 | S & F Heating element 3 KW Suitable for Solar Hot Water systemof capacity 300 LPD. |
| 27 | Supply and fixing LED street light 35/36 watts made up of pressure die cast housing with toughened glass/ PC cover and individual high power LEDs with secondary optics, min IP-65 protection with all accessories internally pre-wired and including connecting up with 3 core 1.5 sqmm twisted flexible copper conductor cable complete all as specified and directed by Engr-in-Charge. |
| 28 | M & L for brick masonry valve pit of size 900x900x900 mm (Internal) depth of chamber to be reckoned from the top of PCC in foundation to top the MS cover 60 cm and including MS sheet cover fabricated friom 3.15 mm thick MS sheet and frame of angle iron 50x50x5 mmwith fixing arrangement, hinges and locking arrangement and paiting with two coat of synthetic paint over a coat of red oxide primerincluding necessary excavationand earthg work in any type of soil, returing filling and removal up to 50 mtr distance, 150 mm thick PCC 1:4:8 type D2 in fdn, brick work in CM 1:4, 15 mm thick plastering in CM 1:4 (both internally and externally), 100 mm thick PCC 1:2:4 type B1 as in flooring, complete all as specified and directed. |
| 29 | M & L for cutting and taking out branch connectionby inserting TEE 150x150x150 mm for new connection, complete all as specified and directed.NOTE : Cost of TEE will deemed to be included in the rate quoted. |
| 30 | Supply, laying and testing 150 mm dia cast iron pipe both ends flanged and drilled including special class \"B\" specials / fittings, complete all as specified and directed. |
| 31 | Supply, laying and testing 150 mm dia ductile iron pipe K-9, single socketed including specialspecials / fittings, complete all as specified and directed. |
| 32 | Supply and fixing wall mounted LEDlight fitting batten type1x10 Watt (02 feet long) extruded aluminium body with heat sink provided for efficiient heat dissipitation and electronic drive completewith all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable, complete all as specified and directed. |
| 33 | S & F factory made epoxy powder coated distribution board VTPN 4 ways conforming to IS 8623-1, IEC-61439-1&3, double door with acrylic top cover (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, stranded DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed. |
| 34 | Taking down old unserviceableflushing cistern with all fittings |
| 35 | Taking down old unserviceable wash hand basin with all fittings |
| 36 | Taking down old unserviceablestainless sink with all fittings |
| 37 | S & F 150 mm dia cast iron non return valve 150 mm dia with all fittings and fixtures,complete all as specified and directed. |
| 38 | Material and Labour for cutting existing road PCC of size 45cm x 60cm for taking out/laying of underground cable and including necessary earth work and making good to match with the existing surface with PPC 1:3;6 typpe CI using 20mm graded agregates complete all as specified and directed. |