| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitablebox and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit/Cassingas required.2 X 2.5 sq. mm + 1 X2.5 sq. mm earth wire |
| 3 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 5 | 4 X4 sq. mm + 2 X 4 sq. mm earth wire |
| 6 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 7 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 8 | 15/16 A switch |
| 9 | 3 pin 5/6 A socket outlet |
| 10 | 6 pin 15/16 A socket outlet |
| 11 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator)6 way , Double door |
| 12 | 8 way , Double door |
| 13 | 12 way , Double door |
| 14 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 15 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 16 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipeof 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 17 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 18 | Supplying with fitting of 400 mm High speedWall fan |
| 19 | Supplying with fitting of 22 Watt LED batten light(commercial) |
| 20 | Supplying and fixing following size/ modules, PVC box alongwith modular base & cover plate for modular switches in recess etc. as required a)3 Module |
| 21 | b)9 module |
| 22 | Supplying and fixing following rating,Four pole, 440 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 Amps |
| 23 | Supplying and fixing following rating,SPN , 240 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. A)63 Amps |
| 24 | B)40 Amps |
| 25 | Removal of Exisiting wiring system and depositing the same complete to thelocation as specified by the department |