|
| 1 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings |
| 2 | S&F Plain, galvanised, mild steel sheeting of 1 mm thickness, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 |
| 3 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) |
| 4 | Cutting cast iron or AC pipes (any section) from 75mm to 150mm dia |
| 5 | Refixing Cast iron rainwater socketed pipes with cement joints, without ears into position at any height and of any dia |
| 6 | Dismanting of wrought iron or mild steel work af any description not otherwise provided for complete all as specified and as directed. |
| 7 | S&F Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe 410-W (Gde E-250 Quality A) |
| 8 | M&L preparation of new steel surfaces over 10cm width / girth and applying two coat of synthetic enamel paint in camouflage pattern (Three colour as approve by GE) over and including a coat of red oxide or zinc chrome primer on old steel sufaces over 10cm width or girth including preparation of surface of any height including all necessary scaffolding complete all as specified and as directed. |
| 9 | M&L preparation of new steel surfaces of any description exceeding 10 cmwidth / girth and applying two coats of black japan over a coat of red oxide primer complete all as specified and as directed. |
| 10 | Taking down chowkat or frames exc 1.5 sqm but n.exc 4.0 sqm each with shutter (without taking off shutters from the frame) |
| 11 | S&F Providing and fixing factory made UPVC white colour casement (Openable) Door made of extruded profile with wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild steel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing with selected quality glass. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) |
| 12 | S&F factory made UPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wallthickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of UPVC multichamberedframe, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), appropriate dimension of UPVC extruded glazing beads and UPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steels crews etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of wateretc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For UPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 13 | S&F factory made UPVC white colour fixed glazed window/ventilator made of (small series)frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of UPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately). Note: For UPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 14 | S&F Sheet glass 4.8 mm thick, tinted type, ordinary quality & glazing with oil putty in squareexc 0.5 sq.m in each pane |
| 15 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 16 | Demolition of Brickworkmasonry, built in cement mortar at ordered portions including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete. |
| 17 | M&LBrickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and as directed. |
| 18 | Taking down cement plaster on brick or stone wall etc including racking out joints hacking for key scrubbing downwith water etc |
| 19 | M&LRendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6, finished even and smooth without using extra cement |
| 20 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 21 | M&L Rendering 10mm thick in cement mortar 1:3 finished even and fair on vertical surfaces on walls for fixing of dado / skirting tiles |
| 22 | M&L screed or bedding layer 20mm thick in cement mortar 1:4 laying floor finishes complete all as specified and as directed. |
| 23 | M&L Light Shade Virified Ceramic tiles 10 (+/-1) mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match |
| 24 | M&L Light Shade Virified Ceramic tiles 10 (+/-1) mm thick (square/ rectangular) polished, area of each not exceeding 0.36 sqm, in skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match |
| 25 | M&Lpreparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkaline resistant primer and 1.5mm thick wall care putty complete all as specified and as directed |
| 26 | M&Lcomplete removal of existing treatment on surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkaline resistant primer and 1.5mm thick wall care putty complete all as specified and as directed |
| 27 | Supply, installation, testing and commissioning of openwall submersible pump set of capacity 3.73 KW/ 05 HP, 3 Phase, 380 Volts, Suction size65 x 50mm diacomplete all as specified and directed. |
| 28 | S&F submersible pump motor DOL starter 5 HP, three phase, 415 volt all as specified and as directed.. |
| 29 | S&F only PVC insulated & sheathed Submersible flate cable 4 Sqmm x 3 core copper conductor 1100 volt grade, ISI Marked, confirming to IS:694/2010 complete all as specified and as directed. |
| 30 | S&F Non Return Valve/ Check valve of size dia 50 mm all as specified and as directed. |
| 31 | Supply and lay pipe galvanized, “Medium grade”, including fittings of 50 mm (2”) dia all as specified and directed by Engr-in-Charge. Note - Rate include cost of laying, excavation, jointing etc. |
| 32 | M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-s ectional area 16 sq. mm x 4 core all as specified and as directed by Engr-in-Charge. Note - Rate of under ground cable includes earth Work, sand cushioning, brick or PCC covering, light Grade GI tubing where necessary,testing etc. |
| 33 | Exacavation in trenches in soft/loose soil n.exc 1.5 metre wide and n.exc 1.5 metre in depth and getting out for taking up/ laying under ground electric cable completed all as specified and directed. |
| 34 | Returning, filling in , including spreading levelling watering and well ramming in layers n,exc 25 cms in depth completed all as specified and directed. |
| 35 | Removing surplus soil to a distance n.exc 50 metre and deposting where directed at a level n.exc 1.5 mtr above the starting point completed all as specified and directed. |
| 36 | Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying completed all as specified and directed. |
| 37 | Supply and laying sub class B bricks of size 25cmx12.5cmx7.5cm (+/-10% tolerance) for protection of UG cable with width equal to length of brick as mechanical protection laid dry and flat completed all as specified and directed. |
| 38 | M&L horizontal boring across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and directed.Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch \"A\". |
| 39 | M&L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 40 | M&L providing cement concrete of ratio 1:3:6 of stone aggregate 40mm grade for UG Sump/covered chambers/valve pit chamber/ Pump House Installations by filling of 50mm thick including demolation of concrete of any description complete all as specified and as directed. |
| 41 | M&L brick work with sub class ‘B’ bricks, straight or curved on plan to exceeding 6m mean radius, built in 1:4 cement mortar including demolation of brick work of any description complete all as specified and directed. |
| 42 | M&L rendering cement plaster (1:4) 10mm thick on brick work or concrete surface including taking down down plaster on brick or stone wall etc. complete all as specified and as directed. |
| 43 | M&L Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including welding , cutting ,hinges , locking arrangments , painting with two coats of synthetic enamel paint after one coat of aluminium red oxide primer including dismantling wrought iron or mild steel work of any description provided complete all as specified and as directed. |
| 44 | Supply, fabrication, installation, testing and commisioning of LT 3 Phase 4 wire 450 Volts system, factory madewater and vermin proof protection floor mounted cubical type LT Panel fabricated from 3.15mm thick CRCA sheet for outer shell & 2.0 mm thick for inner shell with angle iron 50x50x6 mm double door front and back openable type, double door system, hinged opening, rubber lining locking arrangement with anticorrosive paint and epoxy powder coated with pure polyster siemens grey structure, protection class IP-54 fully compartment design with 4 nos of busbar made of copper of ETP grade suitable for 200 Amp (size of copper strip should not be less than 25x6mm for each phase and neutral) pre wired with suitable size of copper strip /copper wire with colour code for connecting outgoing MCCB/MCB including suitable Al earth strip confirming to IS with danger notice plate, cable gland, cable connection with proper lugs, PCC foundation for fixing LT panel with PCC 1:3:6 type C1 using 20mm grade stone aggregate as in padding on top and grouting bolts etc for panel. Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic diag of LT pannels shall be approved by GE before procurement. INCOMING : (a) MCCB 4 pole, 415 volts, 16 KA breaking capacity adjustable thermal magnetic release with lcs=100%, neutral adjustment 100% of rating 63 amps including all fixing accessories with both ends spreaders links -01 No. (Make- LEGRAND /L&T/C&S).OUTGOING :(a) MCB TPN 415V, 10KA, 4 Pole, 40A - 02 Nos.(b) MCB SPN 415 V, 10KA, 2 Pole, 40A - 02 Nos(c) Digital ammeter with selector switch 3 1/2 digit with CTs of Ratio as per rating of MCCB\"s(d) Digital voltmeter with selector switch 3/2 digit -01 No. |
| 45 | Demolition of cement concrete of any description and in any position not otherwise specially privided for (unreinforced) complete all as specified and as directed. |
| 46 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil |
| 47 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point (soil) |
| 48 | M&L PCC 1:4:8 Type D2 using 40mm graded stone aggregates as in Cement concrete in foundations, filling and mass concrete |
| 49 | M&L Glazed ceramic coloured tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match all as directed. |
| 50 | M&L 100 mm thick Cement concrete type B-2, 1:2:4 (40mm graded aggregate) as in sub-floors, sub-bases, floors, pavings etc |
| 51 | S&F Glass dividing strips, 3 mm thick and ditto width of strip 38mm |
| 52 | S&F and testing electric water heater,storage type steel body with copper inner tank and heating element upto 2.0 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV etc. |
| 53 | M&L power point wiring with 2.5 Sqmm multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, includingall accessories casing caping as approved by EIC, with PVCinsulated FRLHS 2.5 sqmm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, for independent socket power point. |
| 54 | S&F Switch of Socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal all as specified and directed. |
| 55 | S&F to floor, walls and ceiling 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011complete all as specified and as directed. |
| 56 | S&F in repairs 15 mm nominal size, nonrising spindle type fancy bib taps as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. |
| 57 | S&F in repairs 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. |
| 58 | S&FPVC Connection with steel reinforced pipe for hot water connectionof suitable Size as per site requirement including rubber washerscomplete all as specified and directed |
| 59 | M&L in replacement of Sub main wiring with two single core PVC-FRLSH insulated unsheathed stranded copper conductor cable of size 2 x 1.5 sqmm for phase & neutral and 1 x 1.5 sqmm as continous earth wire drawn in and including rigid stove enamelled steel conduit ISI markedof size not less than 25 mm dia inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddles, pipe hooks etc fixed properly complete all as specified and directed.Note : Two single core cable + one run of earth copper conductor and steel conduit will be measured and paid as one unit length |
| 60 | All as per item No 59.00 here-in-above but cable of size 2 x 6.0 sqmm for phase & neutral and 1 x 6.0 sqmm for earth wire.Note : Two single core cable + one run of earth copper conductor and steel conduit will be measured and paid as one unit length |
| 61 | S&F of Industrial type Heavy Duty AC Wall Fan, 750mm sweep, air delivery 400 cmm, single phase 230 volts, 50 Hz having aluminium blades complete all as specified and directed |
| 62 | S&F ofsheet metal enclosure double door distribution board single pole and neutral, 4 way 240 volt with 200 amps rated bus bar complete with bus and neutral linkcomplete all as specified and directed. |
| 63 | S&F MCB 6 to 32 amp rating 240V, 10KA \"C\" curve, Single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 64 | All as per item No 63.00 here in before but of SPN and capacity 40 Amps |
| 65 | All as per item No 63.00 here in before but of SPN and capacity 10 Amps |
| 66 | S&F ofsheet metal enclosure double door distribution board single pole and neutral, 2 way 240 volt with 200 amps rated bus bar complete with bus and neutral linkcomplete all as specified and directed. |
| 67 | M&L fixing of Openwell Submersible Pumping set of capacity 10 HP delivery and suction and deliver size 100 x 100 mm, 3 Phase, 380 Volts, 7.5-22.7 LPS discharge, 24-44 Mtr Head,electric driven inclusive of PCC foundation all as specified and directed.Make : Kirloskar, Model Code - KOS-1030+ or equivalent to Crompton/KSB. |
| 68 | S&F submersible pump motor DOL starter 10 HP, three phase, 415 volt, contractor rating 16 Amps, Current rating 13.2 - 20 A complete all as specified and as directed by Engr-in-Charge. Make : BCH , Model : CPEYNBLN or equivalent to C&S/Legrand. |
| 69 | S&F only PVC insulated & sheathed Submersible flate cable 6 Sqmm x 3 core copper conductor 1100 volt grade, ISI Marked, confirming to IS:694/2010 complete all as specified and as directed. |
| 70 | Supply and laying of new GI tube Heavy grade 100 mm bore with all fittings as required at site and laid in trenches incl connecting with existing lines complete all as specified and as directed. |
| 71 | Supply, laying ,jointing andtestingLT underground electric power cable crossed linked XLPE insulated, two or more core galavanised steel strip or wire armoured / PVC insulated armoured cableheavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 25 sqmm 4 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts or passing through pipesetc fixing and connecting accessories such as Aluminium cable lugs, cable glands , nut , bolts , washwers etccomplete all as specified Note:(Excavation, earth work, sand cushioning, protection brick and pipe shall be measured and paid separately under appropriate items) |
| 72 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations of poles etc. and getting outincluding trimming the sides and forming bottom surfaces to required levels in soft/loose soilcomplete all as specified and directed. |
| 73 | Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed. |
| 74 | Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 75 | M&L river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . |
| 76 | M&L laying well burnt old sizebricks, fly ash bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |
| 77 | S&F Galvanised mild steel pipe /tubing, light grade complete with all fittings of 50 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed. |
| 78 | S&F Non Return Valve/ Check valve of size dia 100 mm all as specified and as directed. |
| 79 | M&L PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in motor foundation, filling and massconcrete including demolation of concrete of any descriptioncomplete all as specified and directed. |
| 80 | Supply, fabrication, installation, testing and commisioning of LT 3 Phase 4 wire 450 Volts system, factory madewater and vermin proof protection floor mounted cubical type LT Panel fabricated from 3.15mm thick CRCA sheet for outer shell & 2.0 mm thick for inner shell with angle iron 50x50x6 mm double door front and back openable type, double door system, hinged opening, rubber lining locking arrangement with anti corrosive paint and epoxy powder coated with pure polyster siemens grey structure, protection class IP-54 fully compartment design with 4 nos of busbar made of copper of ETP grade suitable for 200 Amp (size of copper strip should not be less than 25x6mm for each phase and neutral) pre wired with suitable size of copper strip /copper wire with colour code for connecting outgoing MCCB/MCB including suitable Al earth strip confirming to IS with danger notice plate, cable gland, cable connection with proper lugs, PCC foundation for fixing LT panel with PCC 1:3:6 type C1 using 20mm grade stone aggregate as in padding on top and grouting bolts etc for panel. Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic diag of LT pannels shall be approved by GE before procurement. |
| 81 | INCOMING:- (a)MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 100 amps including all fixing accessories with both ends spreader links - 01 No. (Make :- LEGRAND/L&T/ C&S).(b) Digital Voltmeter of range (0-500) volt flush mounting type with selector switch = 01 No (Make :- LEGRAND/L&T/ C&S).(c) Digital Ammeter of range (0-100) Amp flush mounting type with selector switch = 01 No (Make :- LEGRAND/L&T/ C&S).(d)Neon indicator lamp with holder (RYB) = 03 Nos (L&T/Legrand/ C&S).(e)CT 100/5 Amps - 3 NosOUTGOING :-(a) MCCB 3 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 63 amps including all fixing accessories with both ends spreader links - 01 No. (Make :- LEGRAND/L&T/ C&S).(b)MCB TP 40 Amps, 10 KA- 02 Nos |
| 82 | M&L Earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or of steel all as shown in electrical plate No 3 of SSR part-I2009 connected to pole/LT Panel all as specified and testing on completion including. Necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade,for protection of earth stripcomplete all as specified and directed. Note: Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate. |
| 83 | M&L providing RCC column piller 1:2:4 using 10mm TMT bars having dimension 450mm x 450mm x 4 mtr incl Excavation, removing, pcc and plastering on surface also applying liquid compound on surface complete all as specified. |
| 84 | S&F point wiring for one Fan point with 1.5 Sqmm FRLSH multi stranded copper conductor 1100 V grade,as per IS 694: 2010 , ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, includingall accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable duly painted with aluminium paint inside and anticorrosive paint out side with 2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets for the following:-Note :- (i) Contractor has to make the surface good after flushing the sunken box as per existingspecificationwithout any extra cost |
| 85 | S&F of switch piano flush type 5/6 amps single pole one way complete all as specified and directed. |
| 86 | S&F ceiling rose, 3 terminal, polycarbonate /PVC, insulated body, complete all as specified and as directed. |
| 87 | S&F heavy duty exhaust fan 300 mm sweep MS body with antidust painting, 4 blade with heavy duty motor and double ball bearing, 1320 RPM, single phase 230/240 volts copper wounds, Air delivery -1600 CMH complete with all accessories as bird guard/ louvers shutters etc incl making connections with 3 core flexible multistranded copper conductor of size 0.75 Sqmm run through flexible pipe all as specified and as directed including cutting holes and making good the disturbed surfaces of walls in CM(1:4) and finishing the surface as per existing color scheme complete all as specified and as drected. |
| 88 | S&F BLDC ceiling fans, completed with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and directed. |
| 89 | S&F exhaust fan, steel body AC single Phase, 230V of size 300m sweep with blades and frame and louvers complete all as specified and directed. |
| 90 | S&F exhaust fan, steel body AC single Phase, 230V of size 450m sweep with blades and frame and louvers complete all as specified and directed. |
| 91 | S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50Hz, RPM 1200, Copper winding of sweep 250mm completed all as specified and directed. |
| 92 | S&F wall mounted fan 400 mm sweep, AC 230V, 50Hz with all accessories completed all as specified and directed.Make - Havells /Crompton/Usha |
| 93 | Cutting channel, groves or rebates exc 15cm but nexc 30 cm girth and trimming surface completed all as specified and directed. |