| 1 | Electrification of partly constructed Administrative Building of Rangit IV HEP, at Sikkip. |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B |
| 4 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 5 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required.5/6 A switch |
| 6 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required. 3 pin 5/6 A socket outlet |
| 7 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required.LAN Socket Outlet, TV,Telephone socket outlet |
| 8 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 9 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mm x75mm) |
| 10 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) |
| 11 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125 mmX125mm) |
| 12 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mmX150mm) |
| 13 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 20 mm |
| 14 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 32 mm |
| 15 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 40 mm |
| 16 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 17 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 18 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 19 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 20 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 21 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 22 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required TV antenna socket outlet |
| 23 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required |
| 24 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 25 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required 1 Pair |
| 26 | Supply an fixing call bell/buzzer suitable for single phase 230 V Complete as required |
| 27 | Installation, testing and commissioning of celling fan, including wiring the down roads statdard length (upto 30cm) with 1.5 sq mm FRLS PVC insulated, copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on thefan box etx as required. |
| 28 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing commissioning etc. as required upto 450 mm sweep |
| 29 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 Way, Double door |
| 30 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 Way, Double door |
| 31 | Supplying and fixing following way, horizontal type threepole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way ( 4 +12), Double Door |
| 32 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 A |
| 33 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 63A |
| 34 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single 10A |
| 35 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single 20A |
| 36 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole20A |
| 37 | Supplying and fixing 20A, 240V, SPN Industrial Type socket Outlet, with 2 pole and earth metal enclosed plug top aling with 20A C Curve SP MCB in sheet Steel enclosure on surface or in recess with chained metal cover for socket outlet and complete with connections testing and commissioning etc as required |
| 38 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A, 35 KA,TPMCCB |
| 39 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DBcomplete with connections, testing and commissioning etc as required Isolater 63 amp 4P |
| 40 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required RCCB Double pole, 40 A |
| 41 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as requiredRCCB Double pole, 63 A |
| 42 | Supplying and fixing two module 05 stepped type electronic fan regulator on the existing modular plate switch box including connections but xcluding modular plate etc. as required. |
| 43 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 44 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq. mm and upto 95 sq. mm |
| 45 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required (3½ X 120 sq. mm (45mm)) 3½ X 50 sq. mm (45mm) |
| 46 | Supplying and Installing following size of perforated painted with power coating M.S Cable trays with perforatiing not more than 17.5% in Convenient sections joined with connectors suspended from ceiling with M.S suspenders including bolt & nut painting suspenders etc as required 150mm widthX50mm depthX1.6mmt thickness |
| 47 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 48 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required |
| 49 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 50 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ teMetreinating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 51 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 52 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 53 | L.T. Distribution Board With cupper bus bar, out door type kiosk having electrolytic annealed copper bus abr 50x12 for pahse & 50x6 for neutral circuit mounted on glazed porcelain or Bakelite base fittedwith voltmeter, Ammeter, Selectro Switchfor ammeter & Voltmete, Elctronic KWH meter Indicating Lamps cabin light, & two coat epoxy paint of shade 631 as per IS 8623-1 front opening door with gasket & locking arrangement complete with following incomming & Outgoing controls Supply & Fixing: LTDB 100A, Incomming 100A, 4 P, 50KA, MCCB, Outgoing 3 Nos 63TP MCCB, 35 KA, & 1 No. 32A MCCB, 35 KA, with Inbuilt in Thermo Magnetic Release |
| 54 | Changeover Switchs Conforming to IS /IEC: 609473-3 On Load Changeover switchs (side handle) in sheet enclosure double pole 032 amps/240 V |
| 55 | Decorative wall lamp and Mirror Light, LED mirror light Curve& Fixing |
| 56 | Decorative wall lamp & mirror light, muziris laminar wall light & Fixing |
| 57 | (LED Tube lights T5 Batten Confirming to IS 16102: LED Tube light Neptune silver 20W & Fixing |
| 58 | BritoRecessed mounted LED Down Light Round Brito 12W Panel Confirming to IS:16102& Fixing |
| 59 | LED Bulkhead confirming to IS:16102, Vistaglow LED Bulkhead WTI40W LED 7S CW PSU S1 PC ( 20 Watt) (Philips or equivalent & Fixing) |
| 60 | Celling Fan 1200mm 48\"( Havells/Usha) conformig to IS: 374 |
| 61 | Ventilation fans 250mm 10\" (Havells) |
| 62 | Wall Mount Fan 18 inchconformiming to IS :2997& Fixing |
| 63 | 1.1 KV PVC/XLPE Insulated Heavy Duty Power Cable for Working 3.5 core confirming to IS :7098 Part-I, 3.5x 50 Sq.mm. |
| 64 | Inverter Conforming to IEC 62040-1-1, IEC 60950, 5.5KVA & Installation |
| 65 | Battery conformig to IS:1652 & IEC 60950-1 12Volt, 150AH & Installation |
| 66 | Surge Protection Device With Inbuilt MCB Conforming to IEC 61643-11 1 Phase + Neutral |